• 제목/요약/키워드: uniform performance

검색결과 1,538건 처리시간 0.03초

평면식 태양열집열기를 이용한 곡물 건조개선에 관한 연구 (A Study on the Performance of Flat-plate Solar Air Collector and its Application to Grain Drying)

  • 민영봉;최규홍
    • Journal of Biosystems Engineering
    • /
    • 제3권2호
    • /
    • pp.114-125
    • /
    • 1978
  • The use of petroleum fuels in grain drying causes problems of high cost and management. To solve these problems, it is required to study on soLar energy as an alternative to petroleum fuels for grain drying. The purposes of this study were to find out the optimum received area and air flow rate of a flat-plate solar air collector for grain drying and to assess its effects on grain drying with a small grain bin. The results of this study are summarized as follows ; 1. The calculated optimum tilt angles of the collector in the summer and autumn drying seasons were 20 and 50 degress, respectively, in suwon area. 2. The outlet temperature of the collector was $36^\circ C$ on the daily average with the maximum of $36^\circ C$ at 12:00 o clock. Solar radiation on the collector surface was 1.04 ly( 1 langley = 1 cal/$cm^2$) per minute on the daily average and 1.30 ly per minute on the maximum at 11:00am. The thermal efficiency of the collector was 62.4 percent on the daily average, and the air flow-rate per unit receiving are was 1.03 $m^3$/min/$m^2$.4. The calculated optimum receiving area and the air flow-rate per unit cubic volume for paddy in autumn drying season was 2 $m^2$ and 2$m^3$/min , respectively. 5. not significantly difference in the collector efficiency was appeared between the rotating and fixed type of solar collector. 6. For drying of wheat with 0.6 meter of the depth in the bin, approximately 9 hours were required to reduce the moisture content from 21.6% to 13% with air follow rate of 5 $m^3$/min an initial moisture per cubic meter of wheat and with air temperature of $52^\circ C$. 7. In the drying test of rough rice with a turning operation in a grain bin approximately 21 hours were required to reduced the moisture from 21% to 14.5% with airflow rate of 2 $m^3$/min per cubic meter of rice and the air temperature of $43.5^\circ C$. 8. Over-drying at the bottom and less -drying at the top of the grain mass was resulted from the high -temperature of drying air which was obtained from the flat-plate solar collector in this test. An appropriate operation should be prepared for the uniform moisture of the grain in the bin.

  • PDF

터진고리 형태의 암석시편에 대한 인장강도 시험의 이론과 실제 (Theory and Practice in the Tensile Strength Test for Split Ring Shaped Rock Specimen)

  • 최병희;이연규;박찬;박철환
    • 화약ㆍ발파
    • /
    • 제38권1호
    • /
    • pp.30-37
    • /
    • 2020
  • 본 연구에서는 암석의 인장강도를 측정하는 데 터진고리(split ring; SR) 형태의 시편(NX 코어)을 이용하는 굽힘시험법의 적용성을 검토하였다. SR 시험법은 반고리(half ring; HR) 형태의 시편을 이용하는 HR 시험법(Choi et al., 2019)과 개념적으로는 동일하지만 파괴면이 하중방향과 직교하는 특징이 있다. 이 직교성 때문에 SR 시험법은 HR 시험법보다 더 높은 정확성을 발휘할 수 있을 것으로 예상되었다. HR 시편과 마찬가지로 SR 시편은 균일단면을 가진 굽은 각봉이다. 이 특수한 각봉의 이론적 인장강도는 재료강도학의 굽힘이론으로부터 계산할 수 있다. 일련의 LS-DYNA 수치해석을 수행한 결과, 예상대로 인장형 및 압축형 SR 시험법의 강도오차는 1% 및 5%로서 HR 시험법의 오차(12%)에 비해 매우 낮게 나타났다. 두 SR 시험법의 성능을 확인하기 위하여 실내실험을 실시하였다. 비교를 위하여 HR 시험과 Brazilian 시험도 함께 수행하였다. 실험 결과, Brazilian 강도에 대한 인장형 및 압축형 SR 시험의 강도비는 각각 1.2~1.4 및 1.1~1.2로 나타났는데, 이는 통상적인 굽힘시험의 경험치에 비해 너무 작은 수치였다. 결과적으로 SR 시험은 NX 코어로 성형한 암석시편에 대해서는 실용성이 없는 것으로 판단하였다. 반면, HR 시험의 강도비는 선행연구와 본 연구를 통해 1.7~2.0의 범위에 속하여 높은 일관성을 보였다.

국부적 불연속을 갖는 도파관을 따라 전파되는 파동에 대한 파수 영역 유한 요소 해석 (Propagation of Structural Waves along Waveguides with Non-Uniformities Using Wavenumber Domain Finite Elements)

  • 유정수
    • 한국음향학회지
    • /
    • 제33권3호
    • /
    • pp.191-199
    • /
    • 2014
  • 파이프, 평판과 같이 단면의 형상이 길이 방향으로 일정한 도파관 구조물을 따라 전파되는 진동의 반사 및 투과 특성은 여러 공학 분야에서 응용되는 중요한 주제이다. 도파관에 조인트 또는 균열 등의 국부적 불연속이 있는 경우, 스펙트럴 요소(spectral element)와 유한 요소(finite elment)를 결합한 SE/FE 방법이 주로 사용되고 있다. 그러나 이 방법은 보 이론에 기반한 스펙트럴 요소가 사용되므로 저주파수 대역 해석에 국한되는 단점이 있다. 고주파수 대역 해석에는 스펙트럴 수퍼 요소(spectral super element)와 유한 요소를 결합한 SSE/FE 방법이 제안되었으나 유한요소와 스펙트럼 요소의 연성으로 인해 많은 연산 시간이 요구된다. 이러한 문제점을 개선하고자, 본 연구에서는 국부적 불연속 구간의 단면이 일정한 경우에 대해 국부적 불연속 구간을 스펙트럴 수퍼 요소로 대체한 SSE/SSE 연성 해석을 시도하였다. 적용 모델로는 국부적 결함을 가진 레일의 파동 반사 및 투과, 그리고 주기적 보강재를 가진 평판의 진동전파에 대해 적용하였다. 결함을 가진 레일의 해석 예를 통해, 본 논문에서 사용한 SSE/SSE 방법과 기존의 SSE/FE 방법의 성능을 비교하였다. 보강재를 가진 평판의 예를 통해서는 반복 구조를 가진 도파관의 파동 전파 특성 해석에 SSE/SSE 방법이 유용함을 확인하였다.

소방배관 형상에 따른 배관 내진해석 (Seismic Analysis of Firefighting Pipe Networks)

  • 최호성;이재오
    • 한국화재소방학회논문지
    • /
    • 제33권5호
    • /
    • pp.149-154
    • /
    • 2019
  • 지진 발생 시 소방배관의 안전성은 무엇보다 중요하다. 국내의 경우 국가화재안전기준(NFSC)에 따라 사양위주의 설계를 하고 있지만 특별한 성능이 요구되는 건물에는 공학적인 성능위주 설계를 적용하고 있다. 소방배관의 경우 트리방식을 적용하여 왔다. 하지만 여러 단점으로 인해 최근에는 그리드방식, 루프방식을 적용하고 있다. 국내 소방 배관 내진설계는 NFPA 13 의 cook book 방식을 적용하고 있지만, 신뢰성을 확보하기 위해서는 공학적인 해석이 필요하다. 국내에서 적용 중인 NFPA 13 기준은 ASCE 와 ASME 의 지침을 준용한 것으로 지진이나 배관의 공학적 해석이 부족한 기술자들이 사용하도록 만들어 놓은 설계방식이다. 국내 내진설계는 버팀대에 대한 검토만 진행되고 있다. 하지만 신뢰성 있는 해석을 위해서는 배관의 내압, 지속 하중에 의한 힘, 지진과 같은 하중 조건에서의 다양한 해석이 요구된다. 공학적 내진해석을 통해 트리방식 배관은 그리드나 루프 방식의 배관에 비해 안전성이 떨어지는 것을 알 수 있었으며, 응력 기반의 내진해석 방식과 변형률 기반의 해석방식을 비교한 결과 변형률 해석이 Over Stress 범위에서는 보수적인 결과 값을 보였다. 배관의 내진해석은 일률적인 계산을 통한 해석보다 공학적 해석을 통해 엔지니어가 본인의 의도에 맞게 해석을 하는 것이 좀 더 합리적이며, 여러 가지 해석조건을 고려하여 분석되어야 한다.

WRF 기상자료의 토양수분 모형 적용을 통한 밭 토양수분 및 필요수량 산정 (Estimation of Soil Moisture and Irrigation Requirement of Upland using Soil Moisture Model applied WRF Meteorological Data)

  • 홍민기;이상현;최진용;이성학;이승재
    • 한국농공학회논문집
    • /
    • 제57권6호
    • /
    • pp.173-183
    • /
    • 2015
  • The aim of this study was to develop a soil moisture simulation model equipped with meteorological data enhanced by WRF (Weather Research and Forecast) model, and this soil moisture model was applied for quantifying soil moisture content and irrigation requirement. The WRF model can provide grid based meteorological data at various resolutions. For applicability assessment, comparative analyses were conducted using WRF data and weather data obtained from weather station located close to test bed. Water balance of each upland grid was assessed for soils represented with four layers. The soil moisture contents simulated using the soil moisture model were compared with observed data to evaluate the capacity of the model qualitatively and quantitatively with performance statistics such as correlation coefficient (R), coefficient of determination (R2) and root mean squared error (RMSE). As a result, R is 0.76, $R^2$ is 0.58 and RMSE 5.45 mm in soil layer 1 and R 0.61, $R^2$ 0.37 and RMSE 6.73 mm in soil layer 2 and R 0.52, $R^2$ 0.27 and RMSE 8.64 mm in soil layer 3 and R 0.68, $R^2$ 0.45 and RMSE 5.29 mm in soil layer 4. The estimated soil moisture contents and irrigation requirements of each soil layer showed spatiotemporally varied distributions depending on weather and soil texture data incorporated. The estimated soil moisture contents using weather station data showed uniform distribution about all grids. However the estimated soil moisture contents from WRF data showed spatially varied distribution. Also, the estimated irrigation requirements applied WRF data showed spatial variabilities reflecting regional differences of weather conditions.

지진하중을 받는 주철근 겹침이음된 철근콘크리트 교각의 곡률분석 (Experimental Curvature Analysis of Reinforced Concrete Piers with Lap-Spliced Longitudinal Steels subjected to Seismic Loading)

  • 정영수;박창규;송희원
    • 한국지진공학회논문집
    • /
    • 제10권1호
    • /
    • pp.41-49
    • /
    • 2006
  • 지난 1982년 우라카와 근해지진 및 1995년 효고현 남부 지진 등에 의하여 주철근이 겹침이음된 많은 교각들이 주철근 겹침이음부의 활동에 의한 휨-전단파괴를 발생하였음을 경험하였다. 철근콘크리트 교각의 내진성능은 소성힌지구간의 변형능력에 좌우되고 있으며, 이는 곡률연성도로서 평가된다. 우리나라에서는 1992년 내진 설계가 도입된 이후 철근콘크리트 교각의 주철근겹침이음에 대한 규정이 없었으나, 2005년 도로교 설계기준에서 주철근겹침음을 50% 이내에서 허용하고 있다. 본 연구는 단면 직경이 600 mm이고 형상비가 2.5 및 3.5인 주철근 겹침이음이 있는 철근콘크리트 교각에 대하여 지진시 소성힌지부의 곡률분포 및 곡률연성도에 대하여 조사하였다. 실험은 일정한 축력 $P=0.1f{ck}A_g$가 재하된 상태에서 변위제어 방식으로 준정적실험을 실시하였다. 실험결과 반복하중에 의한 주철근 겹침이음부에 활동이 발생하면, 주철근 겹침이음 구간 내의 곡률이 주철근 겹침이음이 없는 경우와 다르게 나타났다. 다시 말하면 주철근 겹침이음 실험체의 겹침이음 구간 중의 하부 곡률은 주철근 겹침이음이 없는 실험체의 경우보다 큰 값을 보이고 있으며, 상부는 작은 값을 보였다. 이로 인하여 교각실험체의 손상은 겹침이음 구간의 하부에 집중되어 휨파괴되는 모습으로 보이는 양상을 보였다.

적외선 비디오에서 Gain과 Offset 결합 보정을 통한 고정패턴잡음 제거기법 (Fixed Pattern Noise Reduction in Infrared Videos Based on Joint Correction of Gain and Offset)

  • 김성민;배윤성;장재호;나종범
    • 대한전자공학회논문지SP
    • /
    • 제49권2호
    • /
    • pp.35-44
    • /
    • 2012
  • 대부분의 최근 적외선 센서는 focal-plane array (FPA) 구조로 되어있다. 이러한 구조의 센서는 공간적 불균일 응답성을 갖는 것으로 알려져 있고, 이로 인해 고정패턴잡음을 발생시킴으로써 영상열화를 가져온다. 따라서 적외선 영상의 고정패턴잡음을 제거하기 위해서는 픽셀 불균일 보정을 해야 한다. 픽셀 불균일 보정기법은 참조물체기반 접근법과 영상기반 접근법으로 나눌 수 있다. 참조물체기반 접근법에서는 흑체와 같은 균일한 온도를 갖는 물체를 이용해서 고정패턴잡음을 분리시킬 수 있는 방법이다. 하지만 센서의 응답성은 시간이 지나면서 변할 수 있기 때문에, 최근에는 비디오 영상을 이용하는 영상기반 접근법이 많이 연구되고 있다. 영상기반 접근법들 중에서 칼만 필터를 기반으로 하는 최신 알고리듬은 영상 간에 움직임 보상 시에 한 방향 워핑을 이용하고 센서의 offset 불균일성만을 보상해준다. 하지만 한 방향 워핑을 이용한 시스템 모델은 영상의 경계 부근에서 고정패턴잡음을 효과적으로 제거하지 못한다. 게다가, offset만 보정하는 접근법은 gain의 불균일성의 영향을 많이 받는 영상에서는 성능이 악화될 수 있다. 그러므로 본 논문에서는 양방향 워핑을 이용하여 시스템 모델링을 하고, gain과 offset의 결합 보정을 수행하는 알고리듬을 제안한다. 모사 영상과 실제 영상에 대한 실험 결과들은 제안하는 알고리듬이 기존 알고리듬들보다 더 효과적으로 고정패턴잡음을 제거하는 것을 확인할 수 있다.

Progress Report on NISS onboard NEXTSat-1

  • Jeong, Woong-Seob;Park, Sung-Joon;Park, Kwijong;Moon, Bongkon;Lee, Dae-Hee;Pyo, Jeonghyun;Park, Youngsik;Kim, Il-Joong;Park, Won-Kee;Lee, Duk-Hang;Park, Chan;Ko, Kyeongyeon;Nam, Ukwon;Han, Wonyong;Im, Myungshin;Lee, Hyung Mok;Lee, Jeong-Eun;Shin, Goo-Hwan;Chae, Jangsoo;Matsumoto, Toshio
    • 천문학회보
    • /
    • 제39권1호
    • /
    • pp.49.1-49.1
    • /
    • 2014
  • The NISS (Near-infrared Imaging Spectrometer for Star formation history) onboard NEXTSat-1 is the near-infrared instrument onboard NEXTSat-1 which is being developed by KASI. The imaging low-resolution spectroscopic observation in the near-infrared range for nearby galaxies, low background regions, star-forming regions and so on will be performed on orbit. After the System Requirement Review, the optical design is changed from on-axis to the off-axis telescope which has a wide field of view (2 deg. ${\times}$ 2 deg.) as well as the wide wavelength range from 0.95 to $3.8{\mu}m$. The mechanical structure is considered to endure the launching condition as well as the space environment. The design of relay optics is optimized to maintain the uniform optical performance in the required wavelength range. The stray light analysis is being made to evade a light outside a field of view. The dewar is designed to operate the infrared detector at 80K stage. From the thermal analysis, we confirmed that the telescope can be cooled down to around 200K in order to reduce the large amount of thermal noise. Here, we report the current status of the NISS development.

  • PDF

$CoCr_{16.2}Pt_{10.8}Ta_4$ 합금박막의 Ti 우선증착에 따른 자기적 특성과 자구형상변화 (Magnetic properties and the shapes of magnetic domain for $CoCr_{16.2}Pt_{10.8}Ta_4$ alloy films with the prior deposition of Ti layer)

  • 이인선;김동원
    • 한국결정성장학회지
    • /
    • 제10권1호
    • /
    • pp.17-22
    • /
    • 2000
  • 수직보자력이 크고 CoCrPt에 비하여 noise 저감 효과가 큰 것으로 알려진 CoCrPtTa계 합금박막의 수직이방성을 더욱 개선하기 위해 Ti를 우선 증착하였다. 본 연구에서는 Ti 두께 변화에 따른 비교적 높은 수직보자력치를 보였던 $CoCr_{16.2}Pt_{10.8}Ta_4$Ti/glass 시편에서 자기적 특성과 자구형상의 변화를 살펴보았다. 또한 VSM(Vibrating Sample Magnetometer)을 이용하여 M-H loop를 측정하였으며 자구형상은 MFM(Magnetic Force Microscopy)로 관찰하였다. 육방정 Ti가 하지층으로서 우선증착되면 bare glass 직접 증착되는 경우보다 CoCrPtTa 자성층의 수직이방성에 현저한 향상을 가져왔으며 Ti의 두께가 두꺼울수록 c-축 배향성도 개선되었다. MFM 결과에 의하면 Ti두레가 20 nm에서 90 nm로 증가함에 따라 자구형상이 연속적인 stripe type에서 mass type으로 분절된 형태로 변하였다. 이는 Ti의 증착이 비자성 Cr 편석 거동에 영향을 미쳐 자화반전시 인접 columnar grain의 자화벡터들간의 상호교환작용을 억제하는 자기적 분리 효과에 기여했음을 의미한다. 아울러 이와 같은 거동은 Ti가 CoCr계 자성층의 수직이방성을 개선하는데 있어서 형상자기이방성적인 측면에서의 기여가 현저함을 의미하기도 한다.

  • PDF

헤테로폴리산을 포함한 직접 메탄올 연료전지용 나피온/폴리페닐렌옥사이드 복합막의 제조 (Preparation of Composite Nafion/polyphenylene Oxide(PPO) with Hetropoly Acid(HPA) Membranes for Direct Methanol Fuel Cells)

  • 김동현;석준호;김화용;이갑수;성준용
    • Korean Chemical Engineering Research
    • /
    • 제44권2호
    • /
    • pp.187-192
    • /
    • 2006
  • 폴리페닐렌 옥사이드(PPO)를 이용하여 헤테로폴리산(HPA)을 고정시킨 박막 제조를 통해 새로운 고분자 복합막을 제조하고 특성을 분석하였다. 헤테로폴리산인 텅스토인산(PWA)이나 몰리브도인산(PMA)을 혼합한 PPO 박막은 서로 같은 용매에 녹지 않으므로 혼합용매를 사용하여 제조하였다. 본 연구에서는 PWA를 녹이기 위한 용매로 메탄올을 PPO를 녹이기 위한 용매로 클로로포름을 사용하였으며, 혼합된 PPO-PWA 용액을 유리판 위에서 제막하였다. 다공성의 PPO-PWA 박막에 나피온 혼합물을 사용하여 복합막을 제조하였고, 제조된 복합막은 이온 전도도와 메탄올 투과도를 측정하여 특성화하였다. PPO-PWA 복합막의 형태와 구조는 SEM(scanning electron microscopy)과 EDS(energy dispersive spectrometer)로 관찰하였고, 복합막은 직접 메탄올 연료전지(DMFC)용 전해질로서의 성능을 시험하였다. PPO-PWA 구조를 가지고 있는 복합막을 이용함으로써 DMFC 내에서의 메탄올 투과 현상을 66% 줄일 수 있었다.