• Title/Summary/Keyword: uniform column

Search Result 104, Processing Time 0.027 seconds

Wind-induced vibration of a cantilever arch rib supported by a flexible cable system

  • Hang Zhang;Zilong Gao;Haojun, Tang;Yongle Li
    • Wind and Structures
    • /
    • v.39 no.1
    • /
    • pp.71-84
    • /
    • 2024
  • The wind-resistant performance of bridges is generally evaluated based on the strip assumption. For the arch rib of arch bridges, the situation is different due to the curve axis and the variable cross-sectional size. In the construction stage, the arch rib supported by a cable system exhibits flexible dynamic characteristics, and the wind-resistant performance attracts specially attention. To evaluate the wind-induced vibration of an arch rib with the maximum cantilever state, the finite element model was established to compute the structural dynamic characteristics. Then, a three-dimensional (3D) fluid-solid coupling analysis method was realized. After verifying the reliability of the method based on a square column, the wind-induced vibration of the arch rib was computed. The vortex-induced vibration (VIV) performance of the arch rib was focused and the flow field characteristics were discussed to explain the VIV phenomenon. The results show that the arch rib with the maximum cantilever state had the possibility of VIV at high wind speeds but the galloping was not observed. The lock-in wind speeds were larger than the results based on the strip assumption. Due to the vibration of arch rib, the frequency of shedding vortices along the arch axis trended to be uniform.

Feasibility Evaluation for Remediation of Groundwater Contaminated with Heavy Metal using Calcium Polysulfide in Homogeneous media (균질한 매질 내 Calcium polysulfide 주입에 따른 고농도 중금속 오염 지하수 정화 타당성 검토)

  • Hyeon Woo Go;Jin Chul Joo;Kyoungphile Nam;Hee Sun Moon;Sung Hee Yoon;Dong Hwi Lee;So Ye Jang
    • Journal of Soil and Groundwater Environment
    • /
    • v.28 no.1
    • /
    • pp.1-14
    • /
    • 2023
  • In this study, column tests using relatively uniform Jumunjin sand media were conducted to evaluate the feasibility of calcium polysulfide (CaSx, CPS) in removing high concentration of Zn2+ in groundwater. The injected CPS solution reacted rapidly with Zn2+ in artificial groundwater and effectively reduced Zn2+ by more than 99% through metal sulfide precipitation. Since the density (d = 1.27 g/cm3 ) of CPS solution was greater than that of water, CPS solution settled down rapidly while capturing Zn2+ and formed stable CPS layer similar to dense nonaqueous phase liquid. Mass balance analysis on Zn2+ in CPS solution suggested that CPS solution effectively reacted with Zn2+ to form metal sulfide precipitates except for high groundwater seepage velocity of 400 cm/d. With greater groundwater seepage velocity, injected CPS did not completely dissolve at the CPS-water interface, but a partially-misible CPS layer continuously moved and reacted with Zn2++ in the direction of groundwater flow. Since hydraulic conductivity (Kh) decreased slightly due to the generated metal precipitates in the inter-pores of media, injection of CPS solution should be optimized to prevent clogging. As evidenced by both XRF and SEM/EDS results, ZnS precipitates were clearly observed through the reaction between the CPS solution and Zn2+. Further study is warranted to evaluate the feasibility of CPS to remove high-concentration heavy metalcontaminated groundwater in complex and heterogeneous media.

On Vortex Reduction Characteristics of Pump Sump Circulating Water Intake Basin of Power Plant Using Hydraulic Experiment (수리실험을 이용한 발전소의 순환수 취수부 흡입수조의 와류저감에 관한 연구)

  • Eom, Junghyun;Lee, Du Han;Kim, Hung Soo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.42 no.6
    • /
    • pp.815-824
    • /
    • 2022
  • Among the main facilities of the power plant, the circulating water used for cooling the power generation system is supplied through the Circulation Water Intake Basin (CWIB). The vortexes of various types generated in the Pump Sump (PS) of CWIB adversely affect the Circulation Water Pump (CWP) and pipelines. In particular, the free surface vortex accompanied by air intake brings about vibration, noise, cavitation etc. and these are the causes of degradation of CWP performance, damage to pipelines. Then power generation is interrupted by the causes. Therefore, it is necessary to investigate the hydraulic characteristics of CWIB through the hydraulic model experiment and apply an appropriate Anti Vortex Device (AVD) that can control the vortex to enable smooth operation of the power plant. In general, free surface vortex is controlled by Curtain Wall (CW) and the submerged vortex is by the anti vortex device of the curtain wall. The detailed specifications are described in the American National Standard for Pump Intake Design. In this study, the circulating water intake part of the Tripoli West 4×350 MW power plant in Libya was targeted, the actual operating conditions were applied, and the vortex reduction effect of the anti vortex device generated in the suction tank among the circulating water intake part was analyzed through a hydraulic model experiment. In addition, a floor splitter was basically applied to control the submerged vortex, and a new type of column curtain wall was additionally applied to control the vortex generated on the free surface to confirm the effect. As a result of analyzing the hydraulic characteristics by additionally applying the newly developed Column Curtain Wall (CCW) to the existing curtain wall, we have found that the vortex was controlled by forming a uniform flow. In addition, the vortex angle generated in the circulating water pump pipeline was 5° or less, which is the design standard of ANSI/HI 9.8, confirming the stability of the flow.

Structural Performance of 800 MPa High-Strength Steel Members and Application to Highrise and Mega Building Structures

  • Lee, Cheol-Ho
    • International Journal of High-Rise Buildings
    • /
    • v.6 no.3
    • /
    • pp.249-259
    • /
    • 2017
  • The use of high-strength steels in construction of highrise and mega building structures can bring about many technological advantages from fabrication to erection. However, key design criteria such as local and lateral stability in current steel design specifications were developed based on tests of ordinary steels which have stress-strain characteristics very different from that of high strength steels. A series of tests on 800 MPa tensile strength steel (HSA800) members are summarized in this paper which were conducted to investigate the appropriateness of extrapolating current ordinary-steel based design criteria to high strength steels. 800 MPa I-shape beam specimens designed according to flange local buckling (FLB) criteria of the AISC Specification developed a sufficient strength for elastic design and a marginal rotation capacity for plastic design. It is shown that, without introducing distinct and significant yield plateau to the stress-strain property of high-strength steel, it is inherently difficult to achieve a high rotation capacity even if all the current stability limits are met. 800 MPa I-shape beam specimens with both low and high warping rigidity exhibited sufficient lateral torsional buckling (LTB) strength. HSA800 short-column specimens with various edge restraint exhibited sufficient local buckling strength under uniform compression and generally outperformed ordinary steel specimens. The experimental P-M strength was much higher than the AISC nominal P-M strength. The measured residual stresses indicated that the impact of residual stress on inelastic buckling of high-strength steel is less. Cyclic seismic test results showed that HSA800 members have the potential to be used as non-ductile members or members with limited ductility demand in seismic load resisting systems. Finally, recent applications of 800 MPa high strength steel to highrise and mega building structures in Korea are briefly presented.

Hydrolysis of Sucrose by Invertase Entrapped in Calcium Alginate Gel (칼슘 알지네이트 젤에 고정화시킨 Invertase에 의한 설탕의 가수분해)

  • Uhm, Tai-Boong;Hong, Jai-Sik;Byun, Si-Myung
    • Applied Biological Chemistry
    • /
    • v.27 no.2
    • /
    • pp.112-118
    • /
    • 1984
  • Inverase was entrapped in calcium alginate gel. The immobilized beads had excellent uniform size and configuration. To screen the optimal conditions possessing high enzyme activity, effects of sodium alginate concentration, $CaCl_2$ concentration, and the incubation time of beads in $CaCl_2$ solution during the immobilization procedure were investigated. Immobilized beads prepared from the optimal conditions had 18.8 units per ml of gel, which is equivalent to 68% of the activity of soluble enzyme. Several kinetic parameters were determined: Km value. 143 mM; optimum pH, 4.5; optimum temperature, $50^{\circ}C$. Enzyme loading capacity was 150 mg per 20 ml gel. No significant decrease in sugar conversion was observed during the column operation for 6 days.

  • PDF

Computation of Meteorologically-Induced Circulation on the East China Sea using a Fine Grid Three-dimensional Numerical Model (세격자삼차원 수치 모형에 의한 동중국해의 기상학적으로 유발된 해류순환의 산정)

  • Park, Byung-Ho;Suh, Kyung-Suk
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.4 no.1
    • /
    • pp.45-58
    • /
    • 1992
  • A three-dimensional hydrodynamic numerical model is used to compute the annual and seasonal meteorologically-induced residual circulation on the Yellow Sea and the East China Sea continental shelf. The model is formulated having irregular coastal boundaires and non-uniform depth distribution representative of nature. The previous three-dimensional model of the East China Sea (Choi. 19U) has been further refined to resolve the flow over the continental shelf in more detail. The mesh resolution of the present finite difference grid system used is 4 minutes latitude by 5 minutes longitude over the entire shelf. The circulation pattern showing depth and spatial distribution of currents over the Yellow Sea and the East China Sea is presented. Meteorologically-induced currents are subsequently used to compute turn-over times for the three depths (surface. mid-depth. bottom) and the total water column of various regions of the Yellow Sea and the East China Sea.

  • PDF

Study on Optimum Installation of Fan in Standard Hanwoo Loose Barn (한우사 내 송풍팬의 최적 설치에 관한 연구)

  • Lee, Seung-Joo;Chang, Dong-Il;Choi, Yoon-Hyuck;Yang, Jae-Woong;Min, Byeong-Joo;Gutierrez, Winson M.;Chang, Hong-Hee
    • Journal of Biosystems Engineering
    • /
    • v.35 no.5
    • /
    • pp.350-356
    • /
    • 2010
  • The fans installed in standard Hanwoo loose barns (room size : 10 m (width) $\times$ 5 m (length)) are frequently used to reduce Hanwoo's heat stress during hot weather and to dry the wet floor. However, the most effective method of installing fans has not been suggested yet. Therefore, this study was carried out to evaluate two methods of installing fans under the ceiling of Hanwoo loose barn by using CFD (Computational Fluid Dynamics) code, FLUENT and to recommend the optimum fan installing method. The fan installation options were fan tilting angles of $45^{\circ}$ and $0^{\circ}$ (horizontal). The fans of 1 m diameter were installed at 3 m above floor. A velocity scale on 10 cm and 110 cm above floor and air flow pattern were used as the parameters to evaluate the fan installing methods. The fans tilted at $45^{\circ}$ angle produced higher wind at 10 cm and 110 cm above floor and more uniform air flow pattern, compared with the fans installed horizontally. Based on these results, fans tilted at $45^{\circ}$ angle may help to reduce Hanwoo's heat stress and will dry the floor better than fans installed horizontally. Therefore, it is suggested that the fans of 1 m diameter in a standard Hanwoo loose barn should be installed at a $45^{\circ}$ tilt angle and 3 m above floor with spacing of 5 m at the center of a room column.

An effective load increment method for multi modal adaptive pushover analysis of buildings

  • Turker, K.;Irtem, E.
    • Structural Engineering and Mechanics
    • /
    • v.25 no.1
    • /
    • pp.53-73
    • /
    • 2007
  • In this study, an effective load increment method for multi modal adaptive non-linear static (pushover) analysis (NSA) for building type structures is presented. In the method, lumped plastisicity approach is adopted and geometrical non-linearties (second-order effects) are included. Non-linear yield conditions of column elements and geometrical non-linearity effects between successive plastic sections are linearized. Thus, load increment needed for formation of plastic sections can be determined directly (without applying iteration or step-by-step techniques) by using linearized yield conditions. After formation of each plastic section, the higher mode effects are considered by utilizing the essentials of traditional response spectrum analysis at linearized regions between plastic sections. Changing dynamic properties due to plastification in the system are used on the calculation of modal lateral loads. Thus, the effects of stiffness changes and local mechanism at the system on lateral load distribution are included. By using the proposed method, solution can be obtained effectively for multi-mode whereby the properties change due to plastifications in the system. In the study, a new procedure for determination of modal lateral loads is also proposed. In order to evaluate the proposed method, a 20 story RC frame building is analyzed and compared with Non-linear Dynamic Analysis (NDA) results and FEMA 356 Non-linear Static Analysis (NSA) procedures using fixed loads distributions (first mode, SRSS and uniform distribution) in terms of different parameters. Second-order effects on response quantities and periods are also investigated. When the NDA results are taken as reference, it is seen that proposed method yield generally better results than all FEMA 356 procedures for all investigated response quantities.

Behavioral characteristics of a chondrostean sturgeon species Acipenser baerii prelarvae in response to different environmental light intensities in a diel photoperiodic cycle

  • Kim, Eun Jeong;Park, Chulhong;Nam, Yoon Kwon
    • Journal of Animal Reproduction and Biotechnology
    • /
    • v.35 no.3
    • /
    • pp.245-257
    • /
    • 2020
  • Behavioral response to a diel photoperiodicity (500 lx for 16 h, 5 lx for 4 h and < 0.5 lx for 4 h) and phototactic characteristics in dark conditions were examined with Siberian sturgeon Acipenser baerii (Chondrostei, Actinopterygii) prelarvae. Siberian sturgeon prelarvae represented both qualitative and quantitative changes in their behavioral patterns according to different light intensities in a diel photoperiodicity. Under daylight conditions (500 lx), prelarvae displayed saltatory changes of behavioral features with ages (Day 0-Day 9) in a general order of swimming-up/drifting, swimming in the upper water column, benthic swimming with rheotaxis, schooling and post-schooling behavior. Compared to daylight conditions, prelarvae tended to show more benthic performances and quantitative reductions of schooling and post-schooling behaviors under dimlight conditions (5 lx). Under dark conditions (< 0.5 lx), prelarvae exhibited a fairly uniform behavioral pattern characterized by the benthic swimming across the bottom of the tank. From phototaxis tests under dark conditions, navigational responses of prelarvae to a spotlight illumination were quantitatively changed as their ages increased. The phototactic responses reached the peak on Day 2, continued until Day 4, and then gradually decreased until Day 8. A partial recovery of positive phototaxis was observed on Day 9. Data from this study suggest that the diel light cycle as well as the light intensity of each interval in the cycle should be considered as important components of a practical guide for evaluating fitness and developmental states of artificially propagated Siberian sturgeon prelarvae.

Separation of Functionalized Heterocyclic Compounds by High Performance Liquid Chromatography(I) (고성능 액체 크로마토그래피에 의한 기능성 헤테로고리화합물의 분리(I))

  • Lee, Kwang-PilI;Cho, Yun Jin;Lee, Young Cheol
    • Analytical Science and Technology
    • /
    • v.10 no.6
    • /
    • pp.408-417
    • /
    • 1997
  • Normal phase or reversed phase liquid chromatographic separation of some structural isomers of functionalized heterocyclic compounds has been carried out by using several different columns and various mobile phases. The optimal experimental conditions for separation of structural isomers were found on a ternary solvent system including alcohol as a modifier. This polar modifier is preferentially adsorbed onto strong adsorption site, leaving a more uniform population of weaker site that then serve to retain the sample. This 'deactivation' of the adsorbent leads to a number of improvements in subsequent separations. The optimal mobile phase system of separation were found on normal phase on structural isomers. Retention mechanism of normal phase system was also studied depending on adsorption strength between solute and stationary phase of column. However, retention factors of reversed phase system were found on hydrophobic interaction with solvophobic effect.

  • PDF