• 제목/요약/키워드: underground gas pipelines

검색결과 71건 처리시간 0.038초

국가 기간 시설물의 전식 대책(안) (A Mitigation Methode of DC Stray Current for Underground Metallic Structures in KOREA)

  • 배정효;하윤철;하태현;이현구;김대경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1609-1611
    • /
    • 2007
  • The owner of underground metallic structures (gas pipeline, oil pipeline, water pipeline, etc) has a burden of responsibility for the corrosion protection in order to prevent big accidents like gas explosion, soil pollution, leakage and so on. So far, Cathodic Protection(CP) technology have been implemented for protection of underground systems. The stray current from DC subway system in Korea has affected the cathodic protection (CP) system of the buried pipelines adjacent to the railroads. In this aspect, KERI has developed a various mitigation method, drainage system through steel bar under the rail, a stray current gathering mesh system, insulation method between yard and main line, distributed ICCP(Impressed Current Cathodic System), High speed response rectifier, restrictive drainage system, Boding ICCP system. In this paper, the mechanism of mitigation method of DC stray current for underground metallic structures is described.

  • PDF

전력케이블과 가스배관의 병행구간에 대한 교류부식 영향 검토 연구 (The Study on the AC Interference of High Power Cable on Underground Gas Pipeline)

  • 배정효;김대경;하태현;이현구;곽방명;임채중
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.470-473
    • /
    • 2000
  • Because of the continuous growth of energy consumption, and also the tendency to site power lines and pipelines along the same routes, the close proximity of high voltage structures and metallic pipelines has become more and more frequent. Moreover, normal steady state and fault currents become higher as electric networks increase in size and power. Therefore, there has been and still is a growing concern (safety of people marking contact with pipeline, risk of damage to the pipeline coating, the metal and equipment connected to pipeline. especially cathodic protection system) about possible hazards resulting from the influence of high voltage power system on metallic structures(gas pipeline, oil pipeline and water pipeline etc.). Therefore, we analyze the interference problems when the gas pipeline is buried with power cable in the same submarine tunnel. This paper present the results of the study about interference mechanism, AC corrosion, limitation of safety voltage and analysis of indiction voltage.

  • PDF

도시가스 배관용 되메움재 기준 개선에 관한 연구 (A Study on the Improvement of the Standards of Backfill Materials for Underground Pipelines Carrying Natural Gas)

  • 류영돈;곽채식;유영조;이수경
    • 한국가스학회지
    • /
    • 제12권3호
    • /
    • pp.75-80
    • /
    • 2008
  • 도시가스안전관리기준 통합고시에서는 도시가스배관 매설시 되메움 기초재료 및 침상재료로 모래 또는 19mm 이상의 큰 입자가 포함되지 않은 양질의 흙을 사용하도록 규정하고 있으나, 현장에서는 대부분 모래만을 사용하고 있는 실정이며, 이로 인해 육상모래 고갈 및 수급곤란 현상이 발생하고, 건설공사 비가 증가하고 있다. 본 논문에서는 되메움재가 배관에 미치는 영향을 연구하고 국내 외의 되메움재 사용실태를 조사한 후 "모래이외의 되메움 재료"에 대한 세부기준을 제시하였다. 본 조사 연구 자료는 정부에서 가스배관의 되메움재료에 관한 도시가스안전관리기준 통합고시 기준을 개정하는 데 일조 할 수 있을 것으로 본다.

  • PDF

방식전용 다기능 전위측정기 개발 연구 (A study on Development of Multiple function meters for anticorrosion at underground gas pipelines)

  • 박규태;유근준;권정락;이국진;윤명섭;송보현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.298-299
    • /
    • 2007
  • 매설배관은 관련법규에 따라 방식(anticorrosion)상태나 배관의 효율적인 유지관리를 위하여 배관의 방식전위를 관로를 따라 주기적으로 측정하여 전철의 영향이나 타 배설배관 및 방식시스템의 상황이 파악되어야 한다. 일반적인 방식전위측정기는 토양비저항이 30 내지 40 $M{\Omega}$ 이상의 높은 지역에서의 방식전위측정 시 전위왜곡이 발생하여 정확한 방식상태를 판단하기 곤란한 경우가 있다. 이러한 장애를 극복하고자 입력임피던스를 100$M{\Omega}$으로 설계하여 방식전위 측정시의 왜곡을 개선 및 정확도를 높이고 방식유지관리에 반드시 필요한 직류 및 교류 전압, 전류, 접지저항, 주파수 등을 측정할 수 있는 방식전용 다기능 계측기를 개발하였으며, 이는 측정 및 휴대가 용이하여 현장에 도움을 주고 있다.

  • PDF

도시가스 매설배관 보수기준 개발에 관한 연구 (A Study on the Development of the Repair Standards for Underground Pipelines Carrying Natural Gas)

  • 류영돈;이진한;조영도
    • 한국가스학회지
    • /
    • 제20권4호
    • /
    • pp.33-43
    • /
    • 2016
  • 미국과 유럽의 가스회사에서는 배관의 보수방법으로 그라인딩, 육성용접, 슬리브덮개용접, 복합재료보수, 핫태핑, 클램프 등 다양한 방법을 사용하고 있으며, 배관에 손상이 발생한 경우 사용적합성 평가를 거쳐 배관보수를 실시하고 있다. 또한, 미국과 영국 등에서는 매설된 도시가스배관이 타공사 또는 부식으로 인해 손상을 입은 경우 손상형태별로 적용 가능한 배관보수방법을 규정하고 있다. 국내의 경우에는 노후된 중압배관에 대하여 정밀안전진단을 하도록 하고 있으며, 정밀안전진단결과 발생된 결함의 종류 및 정도에 따라 배관을 보수, 교체 또는 신설하도록 규정하고 있다. 그러나 보수 및 보강 방법에 대하여는 기준이 마련되어 있지 않아 배관에 손상이 발생한 경우 주로 손상된 배관을 절단한 후 단관(短管)으로 교체하는 방법만을 사용하고 있다. 본 논문에서는 미국, 영국 등 국외의 보수방법 및 기준을 조사하고, 국내의 매설배관 검사 방법 등에 대해 조사하고, 보수방법 시험 결과를 분석한 후 국내 실정에 맞는 배관보수기준(안)을 제시하였다. 개발되는 기준에 따라 도시가스사업자가 정밀안전진단 결과의 후속조치로 배관보수를 하는 경우 가스공급을 중단하지 않아도 되므로 가스의 안정적 공급에 기여할 수 있을 것으로 판단된다.

Ground strain estimation for lifeline earthquake engineering

  • Koike, Takeshi;Maruyama, Osamu;Garciano, Lessandro Estelito
    • Structural Engineering and Mechanics
    • /
    • 제25권3호
    • /
    • pp.291-310
    • /
    • 2007
  • Current seismic design guidelines in Japan are diverse in the seismic ground strain estimates, because the concepts on a horizontally propagating wave model are not consistent in various seismic design guidelines including gas, water and other underground structures. The purpose of this study is (a) to derive the analytical methods to estimate the ground strains for incident seismic waves, (b) to develop a statistical estimation technique of the ground strains, and finally (c) to compare the theoretical estimation with the observed data which was measured at 441 sites in the 1999 Chi-Chi Earthquake in Taiwan.

SUSTAINABILITY SOLUTIONS USING TRENCHLESS TECHNOLOGIES IN URBAN UNDERGROUND INFRASTRUCTURE DEVELOPMENT

  • Dae-Hyun (Dan) Koo;Samuel Ariaratnam
    • 국제학술발표논문집
    • /
    • The 5th International Conference on Construction Engineering and Project Management
    • /
    • pp.367-374
    • /
    • 2013
  • Underground infrastructure systems provide essential public services and goods through buried structures including water and sewer, gas and petroleum, power and communication pipelines. The majority of existing underground infrastructure systems was installed in green field areas prior to development of complex urban built environments. Currently, there is a global trend to escalate major demand for underground infrastructure system renewal and new installation while minimizing disruption and maintaining functions of existing superstructures. Therefore, Engineers and utility owners are rigorously seeking technologies that minimize environmental, social, and economic impact during the renewal and installation process. Trenchless technologies have proven to be socially less disruptive, more environmentally friendly, energy conservative and economically viable alternative methods. All of those benefits are adequate to enhance overall sustainability. This paper describes effective sustainable solutions using trenchless technologies. Sustainability is assessed by a comparison between conventional open cut and trenchless technology methods. Sustainability analysis is based on a broad perspective combining the three main aspects of sustainability: economic; environmental; and social. Economic includes construction cost, benefit, and social cost analysis. Environmental includes emission estimation and environmental quality impact study. Social includes various social impacts on an urban area. This paper summarizes sustainable trenchless technology solutions and presents a sustainable construction method selection process in a proposed framework to be used in urban underground infrastructure capital improvement projects.

  • PDF

국가기간시설물의 전식대책(안) 및 그 적용 사례(1) (A Case Study(1) of Mitigation Methode of DC Stray Current for Underground Metallic Structures in KOREA)

  • 배정효;하윤철;하태현;이현구;김대경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1612-1614
    • /
    • 2007
  • The owner of underground metallic structures (gas pipeline, oil pipeline, water pipeline, etc) has a burden of responsibility for the corrosion protection in order to prevent big accidents like gas explosion, soil pollution, leakage and so on. So far, Cathodic Protection(CP) technology have been implemented for protection of underground systems. The stray current from DC subway system in Korea has affected the cathodic protection (CP) design of the buried pipelines adjacent to the railroads. In this aspect, KERI has developed a various mitigation method, drainage system through steel bar under the rail, a stray current gathering mesh system, insulation method between yard and main line, distributed ICCP(Impressed Current Cathodic System), High speed response rectifier, restrictive drainage system. We installed the mitigation system at the real field and test of its efficiency in Busan and Seoul, Korea. In this paper, the results of field test, especially, distributed ICCP system is described.

  • PDF

도심지 노면하부 지반함몰 및 공동탐사 사례 연구 (Study on Subsurface Collapse of Road Surface and Cavity Search in Urban Area)

  • 채휘영
    • 터널과지하공간
    • /
    • 제27권6호
    • /
    • pp.387-392
    • /
    • 2017
  • 최근 도심지 도로 하부 지반함몰 사고는 상수관로, 하수관거, 통신관로, 가스관로, 배전지중관로, 지하철 등의 다양한 공익시설 및 지하구조물이 시공되고 있으며 이러한 시설물의 부적절한 시공, 노후로 인한 시설물 손상, 유지관리 소홀이 그 원인으로 추정되고 있다. 도로함몰은 도로하부에서 매설관 파손 등의 원인으로 공동이 발생한 후 공동이 성장 확대되어 포장면 하부까지 도달하고 도로를 통행하는 차량의 하중을 도로포장 부분이 지탱할 수 없을 정도의 소성변형이 발생하여 갑자기 함몰이 발생할 경우 인명피해 및 교통장애를 초래하는 등 사회전반적인 안전과 경제 발전에 위협이 될 수 있다. 서울시에서는 도로 하부의 공동이 함몰되기 이전 단계에서 3D GPR 탐사를 통해 발견하여 복구함으로써 지반함몰에 따른 피해를 사전에 차단하는 노력이 우선적으로 진행되고 있으며 그 사례를 소개하였다.

지중 금속구조물 부식감시를 위한 영구매설용 기준전극 개발 (Development of Permanent Reference Electrode for Corrosion Monitoring of Underground Metallic Structures)

  • 하윤철;배정효;하태현;이현구;이재덕;김대경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.532-534
    • /
    • 2004
  • The advancement of electronics and telecommunication technologies has forced the risk management system for underground metallic structures to evolve into the remote monitoring and control system. Especially, facilities such as gas pipelines, oil pipelines and water distribution lines might make hazardous effect on human safety without continuous monitoring and control. As a result, pipeline engineers have applied cathodic protection system to prevent the degradation of their facilities by corrosion and carried out a periodic monitoring of the pipe-to-soil (P/S) potentials at numberous test boxes along their pipelines. The latter action on a road in downtowns, however, is so much dangerous that the inspectors should be ready to suffer the threatening of their lives and maintenance. In order to minimize these social costs and hazards, a stand-alone type corrosion monitoring equipment which can be installed in test box, store the P/S data for given Belied and send the data by wired/wireless telecommunications is under development. In order to obtain the exact P/S data, however, a reference electrode should be located as close to the pipeline as possible. Actually, the measured potential by a conventional portable reference electrode contain inevitably an IR drop portion caused by the current flow from the cathodic protection rectifier or the subway railroad. To minimize this error, it is recommended that the reference electrode should be buried within 10 cm from the pipeline. In this paper, we describe the design parameters for fabricating the permanent type reference electrode and the characteristics of the developed reference electrode.

  • PDF