• Title/Summary/Keyword: underground depth

Search Result 657, Processing Time 0.026 seconds

Comparison and Analysis of Field Hydraulic Tests to Evaluate Hydraulic Characteristics in Deep Granite Rockmass (심부 화강암반의 수리특성 평가를 위한 현장수리시험 비교 및 해석 연구)

  • Dae-Sung Cheon;Heejun Suk;Seong Kon Lee;Tae-Hee Kim;Ki Seog Kim;Seong-Chun Jun;SeongHo Bae
    • Tunnel and Underground Space
    • /
    • v.34 no.4
    • /
    • pp.393-412
    • /
    • 2024
  • In selecting a disposal site for high-level radioactive waste, the hydrogeological research of the site is very important, and the hydraulic conductivity and the storage coefficient are key parameters. In this study, the hydraulic conductivity obtained by two different types of field hydraulic test equipment and methods was compared and analyzed for the deep granite rockmass in the Wonju area to understand the hydraulic characteristics of the deep granite rockmass. One was to perform the lugeon test, constant pressure injection test, and slug test at a maximum depth of 602.0 m by using the auto pressure/flow injection system, and the calculated hydraulic conductivity ranged from 1.26E-9 to 4.16E-8 m/s. In the overall depth, the maximum and minimum differences of the hydraulic conductivity were found to be about 33 times, and in the same test section, the difference by test method or analysis method was 1.13 to 8.25 times. In the other, the hydraulic conductivity calculated by performing a constant pressure injection test and a pulse test at a maximum depth of 705.1 m using the deep borehole hydraulic testing system was found to be 1.60E-10 to 2.05E-8 m/s, and the maximum and minimum differences were found to be about 130 times. In the constant pressure injection test, the difference depending on the analysis method was found to be 1.02 to 2.8 times. The hydraulic conductivity calculated by the two test equipment and methods generally showed similar ranges as E-9 and E-8 m/s, and no clear trend was observed according to depth. It was found that the granite rockmass in the Wonju area where the field hydraulic test was conducted showed low or very low rockmass permeability, and although there are differences in the range of hydraulic conductivity and the depth of application that can be measured depending on the applied test equipment and test method, it is generally believed that reliable results were presented.

Sewer overflow simulation evaluation of urban runoff model according to detailed terrain scale (상세지형스케일에 따른 도시유출모형의 관거월류 모의성능평가)

  • Tak, Yong Hun;Kim, Young Do;Kang, Boosik;Park, Mun Hyun
    • Journal of Korea Water Resources Association
    • /
    • v.49 no.6
    • /
    • pp.519-528
    • /
    • 2016
  • Frequently torrential rain is occurred by climate change and urbanization. Urban is formed with road, residential and underground area. Without detailed topographic flooded analysis consideration can take a result which are wrong flooded depth and flooded area. Especially, flood analysis error of population and assets in dense downtown is causing a big problem for establishments and disaster response of flood measures. It can lead to casualties and property damage. Urban flood analysis is divided into sewer flow analysis and surface inundation analysis. Accuracy is very important point of these analysis. In this study, to confirm the effects of the elevation data precision in the process of flooded analysis were studied using 10m DEM, LiDAR data and 1:1,000 digital map. Study area is Dorim-stream basin in the Darim drainage basin, Sinrim 3 drainage basin, Sinrim 4 drainage basin. Flooding simulation through 2010's heavy rain by using XP-SWMM. Result, from 10m DEM, shows wrong flood depth which is more than 1m. In particular, some of the overflow manhole is not seen occurrence. Accordingly, detailed surface data is very important factor and it should be very careful when using the 10m DEM.

An Experimental Study on Pullout Behavior of Shallow Bearing Plate Anchor (얕은 지압형 앵커의 인발거동특성에 관한 실험적 연구)

  • Hong, Seok-Woo;Kim, Hyung-Kong
    • Journal of the Korean Geotechnical Society
    • /
    • v.30 no.2
    • /
    • pp.5-18
    • /
    • 2014
  • Depending on the underground load support mechanism, anchors are classified as friction anchors, bearing plate anchors and the recently developed combined friction-bearing plate anchors which combine the characteristics of both the friction and bearing plate type anchors. Even though numerous studies have been performed on bearing plate anchors, there were only few studies performed to observe the failure surface of bearing plate anchors. Furthermore most of the soil materials used on these tests were not real sand but carbon rods. In this study, sand was placed in the soil tank and laboratory tests were performed with bearing plate anchors installed with an embedment depth (H/h) ranging from 1~6. The variation in the pullout capacity and the behaviour of soil with the embedment depth (H/h) were observed. Ground deformation analysis program was also used to analyze soil displacement, zero extension direction, maximum shear strain contours. It was determined from the analysis of the results that at ultimate pullout resistance the deformation was 5 mm and the failure surface occurred in a narrower area when compared with results of the previous researches. It was also observed that the width of the fracture surface gradually becomes wider and expands up to the surface as the deformation increases from 10 mm to 15 mm.

Site Characteristics Around the Gongsansung Circular Pond in Gongju Based on the Seismic Methods (탄성파탐사를 이용한 공주 공산성 원형연못의 지반조사)

  • Oh, Jin-Yong;Suh, Man-Cheol
    • Economic and Environmental Geology
    • /
    • v.38 no.6 s.175
    • /
    • pp.623-631
    • /
    • 2005
  • We applied the seismic method to investigate the site characteristics around the Circular Pond (top diameter 7.3 m, bottom diameter 3 m, and depth 4.78 m) at the Ssangsujung Park within the Gongsansung in Gongju. Previous excavations for the cultural assets beneath the Ssangsujung Park disclosed the assumed site of the Palace of the Beakje Dynasty and the Circular Pond containing the Bakje relics. We demonstrated that the seismic prospecting can be applicable to delineate the underground structure around the cultural properties by the three kinds of seismic approaches: walk-away test, conventional refraction method, and equal-distance refraction survey. The last method which is designed by this work ran detect the I-W variations of seismic velocity in the subsurface medium across the Circular Pond on the basis of the difference of the P-wave arrival times between the 1-m-spacing 24 geophones and the corresponding 24 shots parallel with the geophone profile. From the combined results, prominent three-layer velocity structure is observed around the Circular Pond. The bottom layer is interpreted as the basement rock which is exposed near the Ssangsujung whereas the upper layer with relatively lower velocities is interpreted to be the artificial covering. The basement depth beneath the Circular Pond is deeper than the norhern area. The western basement of Circular Pond has the thicker weaker layer compared with the eastern part. Thus, the middle layer could be constructed as the artificial foundation during the Beakje Dynasty. Consequently, the Kong-sansung Circular Pond is possibly built upwardly rather than digging.

Development of an Artificial Neural Expert System for Rational Determination of Lateral Earth Pressure Coefficient (합리적인 측압계수 결정을 위한 인공신경 전문가 시스템의 개발)

  • 문상호;문현구
    • Journal of the Korean Geotechnical Society
    • /
    • v.15 no.1
    • /
    • pp.99-112
    • /
    • 1999
  • By using 92 values of lateral earth pressure coefficient(K) measured in Korea, the tendency of K with varying depth is analyzed and compared with the range of K defined by Hoek and Brown. The horizontal stress is generally larger than the vertical stress in Korea : About 84 % of K values are above 1. In this study, the theory of elasto-plasticity is applied to analyze the variation of K values, and the results are compared with those of numerical analysis. This reveals that the erosion, sedimentation and weathering of earth crust are important factors in the determination of K values. Surface erosion, large lateral pressure and good rock mass increase the K values, but sedimentation decreases the K values. This study enable us to analyze the effects of geological processes on the K values, especially at shallow depth where underground excavation takes place. A neural network expert system using multi-layer back-propagation algorithm is developed to predict the K values. The neural network model has a correlation coefficient above 0.996 when it is compared with measured data. The comparison with 9 measured data which are not included in the back-propagation learning has shown an average inference error of 20% and the correlation coefficient above 0.95. The expert system developed in this study can be used for reliable determination of K values.

  • PDF

Mapping of Underground Geological Boundaries overlain by Conductive Overburden: Application of TEM Soundings (TEM 탐사에 의한 간척지내 전도성 표층 하부 지질 구성 파악)

  • Hwang, Hak-Soo;Moon, Sang-Ho
    • The Journal of Engineering Geology
    • /
    • v.21 no.3
    • /
    • pp.213-219
    • /
    • 2011
  • Transient/time-domain electromagnetic (TEM) soundings were carried out on reclaimed land, since the TEM sounding has good resolution of a conductive and thin overburden. The reclamation material is marine clay dredged from the seafloor, which is currently undergoing consolidation in the upper part of the dredged layer. The conductivity of the marine-origin clay is generally more than 0.3 S/m. The aim of the TEM sounding was to determine the depths of weathered and soft rocks overlain by thick and conductive overburden. The TEM responses were measured at delay times of 0.050-20.575 ms with a $30{\times}30$ m coincident loop array. Data from the TEM inversion and core logging indicate that the resistivities of the conductive overburden are less than 2 ${\Omega}$-m, while those of the weathered and soft rocks are 10-20 and 70 ${\Omega}$-m, respectively. The depth to weathered rock is 26-58 m and the depth to soft rock is 46-75 m.

Optimum Mix Proportion and Characteristics of the Combined Self Compacting Concrete according to Cement Types (시멘트 종류에 따른 병용계 자기충전 콘크리트의 최적배합비와 특성)

  • Kwon, Yeong-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.1
    • /
    • pp.55-64
    • /
    • 2009
  • This study is aimed to derive the optimum mix proportion of the combined self compacting concrete according to cement types (blast-furnace slag cement and belite cement) and to propose the basic data to field construction work after evaluating the quality properties. Specially, lime stone powder (LSP) as binder and viscosity agent are used in the combined self compacting concrete because slurry wall of an underground LNG storage tank should be kept stability of quality during concrete working. Replacement ratio of LSP is determined by confined water ratio test and main design factors including fine aggregate ratio ($S_r$), coarse aggregate ratio ($G_v$) and water-cement ratio (W/C) are selected. Also, quality properties including setting time, bleeding content, shortening depth and hydration heat on the optimum mix proportion of the combined self compacting concrete according to cement type are compared and analyzed. As test results, the optimum mix proportion of the combined self compacting concrete according to cement type is as followings. 1) Slag cement type-replacement ratio of LSP 13.5%, $S_r$ 47% and W/C 41%. 2) Belite cement type-replacement ratio of LSP 42.7%, Sr 43% and W/C 51%. But optimum coarse aggregate ratio is 53% regardless of cement types. Also, as test results regarding setting time, bleeding content, shortening depth and hydration heat of the combined self compacting concrete by cement type, belite cement type is most stable in the quality properties and is to apply the actual construction work.

불국사 석탑의 지반 특성에 대한 지구물리탐사

  • Seo, Man-Cheol;O, Jin-Yong;Choe, Hui-Su
    • Journal of the Korean Geophysical Society
    • /
    • v.5 no.2
    • /
    • pp.143-151
    • /
    • 2002
  • Bulku temple in the city of Kyungju, Korea, built in 791 and reconstructed in the 20th century, is the home of seven national treasures including two three-story stone pagodas, Dabotap (height 10.4m, width 7.4m, weight 123.2ton) and Seokgatap (height 10.8m, width 4.4m, weight 82.3 ton). An earlier archaeological investigation shows that stone pagodas have experienced severe weathering process which will threaten their stability. At the base part of Dabotap, an offset of the stone alignment is also observed. For the purpose of the structural safety diagnosis of two pagodas, we introduce the nondestructive geophysical methods. Site characteristics around the pagodas are determined by the measurement of multiple properties such as seismic velocity, resistivity, image of GPR(ground-penetrating radar). Near the pagodas, the occurrence of high resistivity (up to 2200 Ωm) is obvious whereas their outskirts have as low as 200 Ωm. For the velocity of the P wave, the site of Dabotap has the range of 500~800 m/s which is higher than counterpart of Seokgatap with the velocity of 300~500m/s, indicating the solider stability of Dabotap site. Consequently, in addition to GPR images, the foundation boundaries beneath each stone pagodas are revealed. The Dabotap site is in the form of an octagon having 6-m-long side with the depth of ~4m, whereas the Seokgatap site the 9m × 10m rectangle with the depth of 3m. These subsurface structures appear to reflect the original foundations constructed against the stone load of ~8 ton/㎡. At the subsurface beneath the northeast of each pagoda, low seismic velocity as well as low resistivity is prominent. It is interpreted to represent the weak underground condition.

  • PDF

Analysis of Penetration Phenomenon of High Altitude Electromagnetic Pulse into Buried Facilities with Various Moisture Content and Depth (수분 함유량 및 지하 구조물 깊이에 따른 고고도 전자기파(HEMP) 투과 현상 분석)

  • Kang, Hee-Do;Oh, Il-Young;Yook, Jong-Gwan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.6
    • /
    • pp.644-653
    • /
    • 2013
  • In this paper, a formulation for obliquely incident electromagnetic wave has been presented for an analysis of highpower electromagnetic pulse penetration into multilayered dispersive media. Based on generalized models of measured dielectric constants and propagation channels reflecting the Earth's general features, the propagation phenomenon of the obliquely incident early-time(E1) high altitude electromagnetic pulse(HEMP) is analyzed. In addition, the polarization and critical angle are also considered. It is found that the total reflection occurs at an incident angle of about 38 degrees at the soil-rock interface, and that the parallel-polarized E1 HEMP penetrates better than the perpendicular-polarized one. The peak level of the penetrating electric field is found to be 5.6 kV/m at normal incidence, regardless of the type of polarization, and E1 HEMP is greatly reduced near the critical angle. Moreover, the penetrating E1 HEMP is analyzed as a variation of moisture content and depth of materials, resulting E1 HEMP could be useful in determining the levels of shielding required for buried facilities.

A Development of Automation system and a way to use Solar Energy System Efficiently in Greenhouse(2) - Study on improvement of growth and yield of a cucumber in soil heating - (시설원예 태양열 시스템의 효율적 이용과 자동화 장치개발(2) -지중가온에 의한 오이 생육 및 수량성 향상에 관한 연구-)

  • 김진현;오중열;구건효;김태욱
    • Journal of Bio-Environment Control
    • /
    • v.7 no.1
    • /
    • pp.25-33
    • /
    • 1998
  • Root zone temperature have influenced on protected cultivation in winter season. Especially root zone temperature is acted on limiting factor in crop cultivation. This study was conducted to obtain optimum temperature of root zone in Protected cultivation Root zone was warmed by heated water($28^{\circ}C$) flowing through the PPC pipe(${\phi}15$) buried depth 40 cm. And the flowing water was heated by solar system. Minimum air temperature during night time was set at $14^{\circ}C$ and maximum air temperature during day time was set at $28~30^{\circ}C$ the growing period of cucumber was from Nov. 6, 1996 to Jan. 30, 1997. The results are summarized as follows. 1. Average soil temperature at 15~20 cm depth was $22^{\circ}C$ at warming plots, $17~18^{\circ}C$ at non-warming plots 2. Early growth in leaf length, stem diameter, number of leaves and leaf area for 30 days after planting were accelerated by root zone warming. Especially, the grawing rate of soil warming plots was higher 27% in leaf length, 51% in leaf number, 150% in leaf area than non-warming Plots. Above-ground and underground part of warming plots was higher 117%, 56% than non-warming plots. 3. In total yield analysis, number of fruits were 614 in soil warming and 313 in non-warming plots. In the result, total yield of soil warming plots was increased with 196% than non-warming plots. 3. In total yield analysis. number of fruits were 614 in soil warming and 313 in non-warming plots. In the result. total yield of soil warming plots was increased with 196% than non-warming plots.

  • PDF