• Title/Summary/Keyword: under-layer

Search Result 4,063, Processing Time 0.028 seconds

Conformance Testing of Multi-protocol IUTs (다중계층 프로토콜의 적합성시험 방안)

  • Park, Yong-Beom;Kim, Myeong-Cheol;Kim, Jang-Gyeong
    • The Transactions of the Korea Information Processing Society
    • /
    • v.6 no.11
    • /
    • pp.3086-3096
    • /
    • 1999
  • To declare conformance of multi-protocol Implementation Under Test(IUT), every layer of the multi-protocol IUT should be tested. According to ISO9646, single-layer test method is applied to testing the highest layer of multi-protocol IUT and single-layer embedded test method is used for the layers by layer all the protocols in a multi-protocol IUT. This paper proposes a new method for testing a multi-protocol IUT. The proposed test method assumes that a multi-protocol IUT is under test and that the interfaces between the layers cannot be controlled or observed by the tester. We apply the proposed test method to TCP/IP and compare the application results with those of the existing test turns out that the proposed test method significantly reduces the number of test cases as well as the number of test events while providing the same test coverage. In addition, the proposed test method shows the capability to locate the layer that is source of failure in testing multi-protocol IUTs.

  • PDF

Application of Layered System to the Outdoor Clothing - Through Water Vapor Permeability - (Layered System의 아웃도어 의류에의 적용 - 수분전달 특성을 중심으로 -)

  • Oh, Ae-Gyeong
    • Fashion & Textile Research Journal
    • /
    • v.8 no.6
    • /
    • pp.709-712
    • /
    • 2006
  • The aim of this study is to find out comfortable combinations of layered system for outdoor activities through water vapor permeability. Layering fabrics is an effective way of controlling water transport properties in fabric systems for outdoor activities and analysis of these systems may be useful for designing comfortable clothing. Seven fabrics were chosen for the experiments: two fabrics for base layer, two for the middle layer and three for the shell layer. A total of 12 different layered systems, which are all possible combinations were established using selected fabrics. The water vapor permeability was measured using JIS L1099 under isothermal and non-isothermal conditions. It was found that layered system was working together as a whole having influence on each layer, though every layer offers varying degree of water vapor permeability. Furthermore, it was also found that an optimal combination of the three layered system does exist although the combination may differ according to the ways. The shell layer is the greatest effect of water vapor permeability under isothermal and non-isothermal conditions within layered system.

Effect of Double Layer Nonwoven Fabrics on the Growth, Quality and Yield of Oriental Melon(Cucumis melo L. var. makuwa Mak.) under Vinyl House (보온부직포 이중피복이 참외의 생육, 품질 및 수량에 미치는 영향)

  • Shin Yong Seub;Park So Deuk;Do Han Woo;Bae Su Gon;Kim Jwoo Hwan;Kim Byung Soo
    • Journal of Bio-Environment Control
    • /
    • v.14 no.1
    • /
    • pp.22-28
    • /
    • 2005
  • The use of blankets to preserve heat in oriental melon cultivation is a common practise without artificial heating and warming systems. Efficiency of blanket decreased with annually usage. This experiment was conducted to investigate the effect of double layer nonwoven fabrics on heat conservation, plant growth, fruit quality and yield of oriental melon in greenhouse. The results were compared among the non-woven fabrics of 9+3, 6+6, 6+3 and 12 ounce from transplanting to April 20, 2001, 2002. Night temperature within tunnel was high at 9+3, 6+6, 6+3 and 12 ounce in order. In plant growth, stem length, leaf numbers and exudate, under double layer nonwoven fabrics were better than single layer blanket of 12 ounce especially, 9+3 double layer blanket was the best. Fruit weight, flesh thickness, soluble solid and marketable yield rate remained same in all treatments. Fermented fruit rate was the highest in 12 ounce as $32.9\%,\;19.6\%\;under\;9+3,\;17.1\%\;under\;6+6,\;16.6\%$ under 6+3 double layer nonwoven fabric, respectively. Compared to 2,260kg yield per 10a of 12 ounce single layer nonwoven fabrics, $7\%$ was increased under 9+3 but $3\%\;and\;13\%$ were decreased under 6+6 and 6+3 double layer nonwoven fabrics, respectively. Compared to income, 4,499-thousand-won per 10a, of 12 ounce single layer blanket, $13\%\;and\;3$ were increased under 9+3 and 6+6 double layer nonwoven fabrics, respectively. Whereas, $10\%$ decreased under 6+3 double layer nonwoven fabrics. From this results it is evident that 9+3 double layer nonwoven fabrics was the best for thermokeeping, fruit quality, and was most economic under non heating system.

Seepage Characteristics of Embedded Rock Layer Under the Earth Fill (성토제 하부에 매설된 사석층의 침투특성)

  • Lee Haeng-Woo;Chang Pyoung-Wuck
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.8
    • /
    • pp.63-72
    • /
    • 2005
  • Rocks are dumped to soft marine ground in order to improve trafficability and construction conditions in the tideland reclamation construction sites. Though this rock layer under earth fill has caused in a serious seepage problems after construction, seepage behaviors of this embankment structure is not correctly investigated. Water flow through rock layers is, in general, known as Non-Darcy's flow. However, the embedded rock layer under earth fill is not known whether its flow is governed by Darcy's or Non-Darcy's law. Therefore, a numerical analysis, laboratory model test and filed investigations were performed for analyzing the those seepage characteristics in this research. Results show that there is significance of $95\%$ of confidence between observed heads and seepage rates, and the calculated ones by SAMTLE which is developed under the assumption that the water flows through the two-layer system obey the Darcy's flow. And after operating the hydraulic gradient(i) of $0.10\~0.55$ upon laboratory model, these seepage characteristics of the embedded rock layer show that Reynolds Numbers are less than 10 and the relationship between these velocities of rock layer(v) and hydraulic gradients(i) is linearly proportional with more than 0.79 of the coefficient of correlation $(R^2)$. And the Reynolds Number of the velocity calculated by the relation of v=ki in the embedded rock layer of OO sea dike is $1\~6$. It shows also laminar flow. Based on these results, it is concluded that the seepage characteristics of embedded rock layer under earth fill can be laminar and Darcy's flow.

Formation of Thicker Hard Alloy Layer on Surface of Aluminum Alloy by PTA Overlaying with Metal Powder (알루미늄 합금의 표면경화)

  • Lee, Young-Ho
    • Proceedings of the KWS Conference
    • /
    • 1996.10a
    • /
    • pp.3-15
    • /
    • 1996
  • The formation of a thicker hard alloyed layer have been investigated on the surface of aluminum cast alloy (AC2B) by PTA overlaying process with Cr, Cu and Ni motel powders under the condition of overlaying current 125-200A. overlaying speed 150 mm/min and different powder feeding rate 5-20 g/min. In addition the characteristics of hardening and wear resistance of alloyed layer here been examined in relation to the microstructure of alloyed layer. Main results obtained were summarized as follows: 1) There was an optimum overlaying condition to get a good alloyed layer with smooth surface. This good layer became easy to be formed as increasing overlaying current and decreasing powder feeding rate under a constant overlaying speed. 2) Cu powder was the most superior one in metal powders used due to a wide optimum overlaying condition range, uniform hardness distribution of Hv250-350, good oar resistance and freedom from cracking in alloyed layer with fine hyper-eutectic structure. 3) On the contrary, irregular hardness distribution was usually obtained in Cr ar Ni alloyed layers of which hardness was increased as Cr or Ni contents and reached to maximum hardness of about Hv400-850 at about 60wt%cr or 40wt%Ni in alloyed layer. 4) Cracking occurred in Cr or Ni alloyed layers with higher hardness than Hv250-300 at mere than 20-25wt% of Cr or Ni contents in alloyed layer. Porosity was observed in all alloyed layers but decreased by usage of spherical powder with smooth surface.

  • PDF

Damped Vibrations of Axially-Stressed Laminated Beams using Zig-Zag Finite Element (축방향 하중을 받는 점탄성물질이 심어진 적층보의 지그재그요소를 이용한 진동해석)

  • 이덕규
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2001.10a
    • /
    • pp.1-4
    • /
    • 2001
  • Dynamic analysis of laminated beams with a embedded damping layer under tension or compression axial load is investigated. Improved Layer-Wise Zig-Zag Beam Theory and Interdependent Kinematic Relation using the governing equations of motion are incorporated to model the laminated beams with a damping layer and a corresponding beam zig-zag finite element is developed. Flexural frequencies and modal loss actors under tension or compression axial load are calculated based on Complex Eigenvalue Method. The effect of the axial tension and compression load on the frequencies and loss factors is discussed.

  • PDF

Characteristics of Doped MgO Layer Deposited under Hydrogen Atmosphere

  • Park, Kyung-Hyun;Kim, Yong-Seog
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.375-378
    • /
    • 2006
  • Characteristics of doped MgO layer deposited under hydrogen atmosphere were investigated. Hydrogen gas was introduced during e-beam evaporation of doped MgO and its effects on microstructure, cathodoluminescence, discharge voltages and effective yield of secondary electron emission were examined. The results indicated that the hydrogen influences and doped impurities the concentration and energy levels of defects in MgO layer and that affects the luminance efficiency and discharge delays of the panels significantly.

  • PDF

Bearing capacity of shallow footing under combined loading

  • Kusakabe, Osamu;Takeyama, Tomohide
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.3-25
    • /
    • 2010
  • The paper deals with two bearing capacity problems of shallow footing under combined loading. The first is a FEM study of shallow strip footing on two-layer clay deposits subjected to a vertical, horizontal and moment combined loading, while the second is a centrifuge study of shallow rectangular footing on dry sand under double eccentricity. The FEM results revealed that the existence of top soft layer sensitively affects more on horizontal and moment capacity than vertical capacity for cases of footing on soft clay overlying stiff clay. Practical design charts are presented to evaluate bearing capacities of footing for various combinations of the ratio of the depth of the upper layer to the footing width and the ratio of undrained strength of the upper layer to that of the lower. The centrifuge tests indicated that current design practice of calculating failure load of rectangular surface footing under double eccentricity underestimates the centrifuge loading test data. This trend is more marked when the eccentricity becomes larger. The decreasing trend in failure load with an increase of double eccentricity is rather uniquely expressed by a single curve, using a newly defined resultant eccentricity and the diagonal length of the footing base.

  • PDF

Community Structure of Free-living Marine Nematodes in the Area of Agar-Producing Alga Ahnfeltia Tobuchiensis Field (Starka Strait, Peter the Great Bay, East Sea)

  • Pavlyuk, Olga;Trebukhova, Yulia
    • Ocean Science Journal
    • /
    • v.42 no.3
    • /
    • pp.165-170
    • /
    • 2007
  • The structure of the nematodes communities has been studied in the sediments on two sites located outside and under the layer of Ahnfeltia tobuchiensis (Kanno and Matsubara 1932; Makijenko 1970). Bottom sediments at the stations were represented by sands with a different degree of silting. Specific structure of nematodes at the stations was significantly different under the similar environmental conditions (water depth, dissolved oxygen saturation, salinity, temperature of the bottom layer and organic carbon content inside of the sediment). Nematodes dominated (75.7 %) in meiobenthos community under the layer of A. tobuchiensis where concentration of silt particles was 12 %. Representatives of the family Comesomatidae were dominant. Low index of species diversity and high Simpson domination index were detected in this community. Under a layer of A. tobuchiensis with the thickness of 30 cm concentration of the silt particles was 5.39 %; nematodes density was low and made 32.1 % of the general density of meiobenthos. Species of the families Xyalidae and Monoposthiidae were dominant. Outside of A. tobuchiensis, field percentage of silt particles was minimal (3.1 %) and representatives of families Cyatholaimidae and Axonolaimidae dominated. The specific structure of nematodes in this type of the ground is characterized by high index of species diversity and low level of domination.

Comparison of Sound Absorption Performance between Fresh and Air-dried Leaves by Leaf Composition in Quercus glauca

  • Su Young Jung;Hee-Seop Byeon;Kwang-Soo Lee;Hyun-Soo Kim
    • Journal of Environmental Science International
    • /
    • v.32 no.1
    • /
    • pp.25-35
    • /
    • 2023
  • The purpose of this study was to determine the optimal sound absorption conditions by comparing the sound absorption characteristics of fresh and air-dried leaves of Quercus glauca, the main species of evergreen broadleaf trees (EBLT) in southern Korea. The sound absorption coefficients (SACs) obtained under 18 conditions were comparatively analyzed. The SAC of air-dried leaves improved significantly with increasing leaf layer thickness. The highest average SAC in the fresh leaf group was 0.617, which was observed under the condition of a leaf specimen size of 0.5 × 0.5 cm2 and a leaf layer thickness of 1.75 cm. In a group of air-dried leaves, this was 0.615 under the condition of a leaf specimen size of 0.5 × 0.5 cm2 and a leaf layer thickness of 2.50 cm. The maximum value of SAC for each wavelength was observed under the condition of a leaf layer thickness of 2.50 cm consisting of 0.5 × 0.5 cm2 leaf specimens, ranging from 1,400 Hz to 1,500 Hz.