• Title/Summary/Keyword: under-determined system

Search Result 1,132, Processing Time 0.027 seconds

DIAGNOSTICS OF PLASMA INDUCED IN Nd:YAG LASER WELDING OF ALUMINUM ALLOY

  • Kim, Jong-Do;Lee, Myeong-Hoon;Kim, Young-Sik;Seiji Katayama;Akira Matsunawa
    • Proceedings of the KWS Conference
    • /
    • 2002.10a
    • /
    • pp.612-619
    • /
    • 2002
  • The dynamic behavior of Al-Mg alloys plasma was very unstable and this instability was closely related to the unstable motion of keyhole during laser irradiation. The keyhole fluctuated both in size and shape and its fluctuation period was about 440 ${\mu}{\textrm}{m}$. This instability has been estimated to be caused by the evaporation phenomena of metals with different boiling point and latent heats of vaporization. Therefore, the authors have conducted the spectroscopic diagnostics of plasma induced in the pulsed YAG laser welding of Al-Mg alloys in air and argon atmospheres. In the air environment, the identified spectra were atomic lines of Al, Mg, Cr, Mn, Cu, Fe and Zn, and singly ionized Mg line, as well as strong molecular spectrum of AlO, MgO and AIH. It was confirmed that the resonant lines of Al and Mg were strongly self-absorbed, in particular in the vicinity of pool surface. The self-absorption of atomic Mg line was more eminent in alloys containing higher Mg. These facts showed that the laser-induced plasma was relatively a low temperature and high density metallic vapor. The intensities of molecular spectra of AlO and MgO were different each other depending on the power density of laser beam. Under the low power density irradiation condition, the MgO band spectra were predominant in intensity, while the AlO spectra became much stronger in higher power density. In argon atmosphere the band spectra of MgO and AlO completely vanished, but AlH molecular spectra was detected clearly. The hydrogen source was presumably the hydrogen solved in the base Metal, absorbed water on the surface oxide layer or H$_2$ and $H_2O$ in the shielding gas. The temporal change in spectral line intensities was quite similar to the fluctuation of keyhole. The time average plasma temperature at 1 mm high above the surface of A5083 alloy was determined by the Boltzmann plot method of atomic Cr lines of different excitation energy. The obtained electron temperature was 3, 280$\pm$150 K which was about 500 K higher than the boiling point of pure aluminum. The electron number density was determined by measuring the relative intensities of the spectra1lines of atomic and singly ionized Magnesium, and the obtained value was 1.85 x 1019 1/㎥.

  • PDF

TLS (Total Least-Squares) within Gauss-Helmert Model: 3D Planar Fitting and Helmert Transformation of Geodetic Reference Frames (가우스-헬머트 모델 전최소제곱: 평면방정식과 측지좌표계 변환)

  • Bae, Tae-Suk;Hong, Chang-Ki;Lim, Soo-Hyeon
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.40 no.4
    • /
    • pp.315-324
    • /
    • 2022
  • The conventional LESS (LEast-Squares Solution) is calculated under the assumption that there is no errors in independent variables. However, the coordinates of a point, either from traditional ground surveying such as slant distances, horizontal and/or vertical angles, or GNSS (Global Navigation Satellite System) positioning, cannot be determined independently (and the components are correlated each other). Therefore, the TLS (Total Least Squares) adjustment should be applied for all applications related to the coordinates. Many approaches were suggested in order to solve this problem, resulting in equivalent solutions except some restrictions. In this study, we calculated the normal vector of the 3D plane determined by the trace of the VLBI targets based on TLS within GHM (Gauss-Helmert Model). Another numerical test was conducted for the estimation of the Helmert transformation parameters. Since the errors in the horizontal components are very small compared to the radius of the circle, the final estimates are almost identical. However, the estimated variance components are significantly reduced as well as show a different characteristic depending on the target location. The Helmert transformation parameters are estimated more precisely compared to the conventional LESS case. Furthermore, the residuals can be predicted on both reference frames with much smaller magnitude (in absolute sense).

Optimization of Multi-reservoir Operation considering Water Demand Uncertainty in the Han River Basin (수요의 불확실성을 고려한 한강수계 댐 연계 운영 최적화)

  • Chung, Gun-Hui;Ryu, Gwan-Hyeong;Kim, Joong-Hoon
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.1
    • /
    • pp.89-102
    • /
    • 2010
  • Future uncertainty on water demand caused by future climate condition and water consumption leads a difficulty to determine the reservoir operation rule for supplying sufficient water to users. It is, thus, important to operate reservoirs not only for distributing enough water to users using the limited water resources but also for preventing floods and drought under the unknown future condition. In this study, the reservoir storage is determined in the first stage when future condition is unknown, and then, water distribution to users and river stream is optimized using the available water resources from the first stage decision using 2-stage stochastic linear programming (2-SLP). The objective function is to minimize the difference between target and actual water storage in reservoirs and the water shortage in users and river stream. Hedging rule defined by a precaution against severe drought by restricting outflow when reservoir storage decreases below a target, is also applied in the reservoir operation rule for improving the model applicability to the real system. The developed model is applied in a system with five reservoirs in the Han River basin, Korea to optimize the multi-reservoir system under various future water demand scenarios. Three multi-purposed dams - Chungju, Hoengseong, and Soyanggang - are considered in the model. Gwangdong and Hwacheon dams are also considered in the system due to the large capacity of the reservoirs, but they are primarily for water supply and power generation, respectively. As a result, the water demand of users and river stream are satisfied in most cases. The reservoirs are operated successfully to store enough water during the wet season for preparing the coming drought and also for reducing downstream flood risk. The developed model can provide an effective guideline of multi-reservoir operation rules in the basin.

Estimation of Nursing costs for Hospitalized Patients Based on the KDRG Classification (5개 KDRG(한국형진단명기준환자군)에 대한 간호원가 산정)

  • Park, Jung-Ho;Song, Mi-Sook;Sung, Young-Hee;Ham, Myoung-Lim;Yun, Seon-Ok
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.3 no.2
    • /
    • pp.151-165
    • /
    • 1997
  • A cost analysis for hospitalized patients was performed based on the KDRG classification in order to determine an appropriate nursing fee under the PPS(Prospective Payment System). The data was collected from 20 nursing units of three tertiary hospitals and two secondary hospitals from August 26 to September 15, 1996. The study consisted of 148 inpatients diagnosed for lens procedures(KDRG 03900), tonsillectomy &/or adenoidectomy(KDRG 16100), Cesarean section(KDRG 37000), or vaginal delivery(KDRG 37300) without any complications. The direct or indirect nursing hours of each patients were measured. Then, direct or indirect nursing expenditures of four nursing units, operating room and delivery room were computed. Finally, the resources used including average total nursing hours, average length of stay and average nursing cost of each KDRG were estimated as follows; 1) The average total nursing hours were 640 minutes for lens procedures, 403 minutes for tonsillectomy &/or adenoidectomy, 934 minutes for appendectomy with complicated principal diagnosis, 1,094 minutes for Cesarean section and 631 minutes for vaginal delivery. Significant differences were found in average total nursing hours among hospitals. 2) The average length of stay in lens procedures were 5 days, 4 days for tonsillectomy &/or adenoidectomy, 6 days for appendectomy with complicated principal diagnosis, 8 days for Cesarean section and 3 days for vaginal delivery. All results were within normal determined by the Ministry of Health and Welfare although significant differences existed among hospitals, especially with average length of stay for leng procedures between tertiary hospitals and secondary hospitals which was greater than for those of others. 3) The average nursing cost were 87,146 Won for lens procedures, 69,600 Won for tonsillectomy &/or adenoidectomy, 128,337 Won for appendectomy with complicated principal diagnosis, 151,769 Won for Cesarean section and 85,403 Won for vaginal delivery. These costs were 7.6%, 13.0%, 13.0%, 16.0% and 22.0%, respectively, of the official price fixed by the Ministry of Health and Welfare under the prospective payment system. Research for the analysis of nursing costs according to the severity of illness for those KDRGs shoud be carried out within the period of the PPS pilot project. In addition, a proper nursing fee schedule for a new reimbursement system based upon the result of the above research should be prepared in the near future.

  • PDF

Proposal for Evacuee Guidance of Cloud-based Elevator System in Emergency Situation (클라우드 기반 비상탈출 시 피난유도 승강기시스템 제안)

  • Choi, Jun-Ho;Shin, Seung-Jung
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.1
    • /
    • pp.25-28
    • /
    • 2015
  • Lifts are used as an essential means of transportation within the building in an emergency situation, when used as a means of escape, so expect a lot of research has been conducted high effect. Number of stories in the Seoul-rise building guidelines underground 7th floor, 53 ground floor, floor area $6,800m^2$, floor area $127,050m^2$, use is cultural and convention facilities and sales facilities, business facilities and accommodation (hotel), the construction of public housing (apartments) hagieneun not efficient to install elevators for evacuation mothada was determined separately in designing the lift is designed according to the standards of passenger lifts installed under a judgment as to use for evacuation. However, this does not include detailed design guidelines so far.[1] We propose the Evacuee Guidance of Elevator System that can be used as entering air equipment, sprinkler and smart phone evacuation system.

The delay effect on reality in visual and haptic presentation (시-촉각 지연이 실감도에 미치는 영향)

  • Kim, Jong-Hwa;Whang, Min-Cheol;Kim, Young-Joo
    • Science of Emotion and Sensibility
    • /
    • v.11 no.2
    • /
    • pp.227-234
    • /
    • 2008
  • Graphic and sounds are mainly used for presenting digital content as general. It has been reported that the reality of digital contents was improved by adding haptic factor to the contents of graphic and sounds. Therefore, various haptic system have recently been developed for implementing haptic sensation into digital contents. However, the delay of haptic display sometimes happens due to low hardware performance and causes to deteriorate reality of digital contents. The delay effect on reality has been important to be determined for presenting digital contents with haptic system. Therefore, this study is to find the effect on user's cognition of digital contents evoking both visual and haptic sensation. Eight university students performed 4 repetitive tasks of pushing cube under the two conditions of visual and haptic delay. The delay time of each condition were set 0.5, 1.0, 2.0 and 4.0 second. As the result, both haptic and visual delay were negatively influenced user's recognition while visual delay showed more dominant effect on user's recognition than haptic delay.

  • PDF

Optimization of Diesel Engine Performance with Dual Loop EGR considering Boost Pressure, Back Pressure, Start of Injection and Injection Mass (과급압력, 배압, 분사 시기 및 분사량에 따른 복합 방식 배기 재순환 시스템 적용 디젤 엔진의 최적화에 대한 연구)

  • Park, Jung-Soo;Lee, Kyo-Seung;Song, Soon-Ho;Chun, Kwang-Min
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.18 no.5
    • /
    • pp.136-144
    • /
    • 2010
  • Exhaust gas recirculation (EGR) is an emission control technology allowing significant NOx emission reduction from light-and heavy duty diesel engines. The future EGR type, dual loop EGR, combining features of high pressure loop EGR and low pressure loop EGR, was developed and optimized by using a commercial engine simulation program, GT-POWER. Some variables were selected to control dual loop EGR system such as VGT (Variable Geometry Turbocharger)performance, especially turbo speed, flap valve opening diameter at the exhaust tail pipe, and EGR valve opening diameter. Applying the dual loop EGR system in the light-duty diesel engine might cause some problems, such as decrease of engine performance and increase of brake specific fuel consumption (BSFC). So proper EGR rate (or mass flow) control would be needed because there are trade-offs of two types of the EGR (HPL and LPL) features. In this study, a diesel engine under dual loop EGR system was optimized by using design of experiment (DoE). Some dominant variables were determined which had effects on torque, BSFC, NOx, and EGR rate. As a result, optimization was performed to compensate the torque and BSFC by controlling start of injection (SOI), injection mass and EGR valves, etc.

Optimal Inspection Periods of Safety System of Wolsung Nuclear Power Plant Unit 1 with Human Error Consideration (인간실수를 고려한 월성 원자력발전소 안전계통의 최적점검주기에 관한 연구)

  • Mok, Jin-Il;Seong, Poong-Hyun
    • Nuclear Engineering and Technology
    • /
    • v.26 no.1
    • /
    • pp.9-18
    • /
    • 1994
  • The engineered safeguards of Wolsung nuclear power plant unit 1 contain redundant systems of 2-out-of-3 logic which are not operating under normal conditions but are called upon to act when emergency conditions develop. To ensure their operability, the systems are periodically tested. In this work, we develop the unavailability formulae for 2-out-of-3 logic configurations which take into account the failure probability of the channels tested due to human error in the simultaneous testing scheme. We also develop the model for the probability that the reactor is tripped during the surveillance test due to either system failure or human error. We determined the optimal inspection periods of safety systems, taking into account both the unavailability of the safety system and the probability that the reactor is tripped during the surveillance test. We compared the results with the inspection periods currently used at Wolsung NPP Unit 1. As a result, the inspection periods obtained using a minimum human error (8.24 $\times$ 1$^{-6}$ ) are shorter than those currently used in Wolsung NPP unit 1 whereas the inspection periods obtained using a maximum human error are (4.44 $\times$ 10$^{-4}$ ) longer than those used in Wolsung NPP unit 1.

  • PDF

Prediction and Verification of Hover Performance through Multi-Copter Propulsion System Test Results (멀티콥터의 추진 시스템 실험 결과를 통한 제자리 비행 성능 예측 및 검증)

  • Park, Seungho;Go, Yeong-Ju;Ryi, Jaeha;Choi, Jong-Soo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.46 no.7
    • /
    • pp.527-534
    • /
    • 2018
  • The endurance of the multi-copter is one of the important variables that determine the mission performance. Therefore, accurate endurance should be defined as essential for performing effective missions. In this paper, we present the results of the study on the flight performance of the aircraft, especially the hovering of the drone(multi-copter). Unlike conventional aircraft, which consider aerodynamic performance by the fuselage, the multi-copter is mostly determined by the propulsion system. Therefore, the research method classifies the various parts constituting the drone system into functions, analyzes the performance of the unit parts and obtains the experimental data by sorting out the specifications and functions at the component level and mathematical formulation, The results of this study are as follows. In addition, the 5kg class quad copter was used to predict and verify the voltage change with endurance through analysis of in situ flight. By predicting endurance under various conditions, it can help design/build the right Multi-copter for mission.

Saccharification of lignocellulosics by Supercritical Water (초임계수를 이용한 목질바이오매스의 당화 특성)

  • Choi, Joon-Weon;Lim, Hyun-Jin;Jo, Tae-Su;Han, Gyu-Sung;Choi, Don-Ha
    • New & Renewable Energy
    • /
    • v.3 no.1 s.9
    • /
    • pp.38-45
    • /
    • 2007
  • To characterize thermo-chemical feature of sugar conversion of woody biomass, poplar wood ($Populus\;alba{\times}glandulosa$) powder was treated with supercritical water system. Supercritical water treatment (SCWT) was performed for 60 seconds at different temperatures (subcritical zone 350; supercritical zone $300,\;400,\;425^{\circ}C$) under two pressures $230{\pm}10atm$ as well as $330{\pm}10atm$, respectively, using flow type system. After separation of solid residues from SCWT products, the monomeric sugars in aqueous part converted from poplar wood powder were quantitatively determined by high performance anionic exchange chromatography [HPAEC] equipped with PAD detector and Carbo Pac PA10 column. As the temperature treated increased, the degradation of poplar wood powder was enhanced and ca 83% of woody biomass was dissolved into the water at $425^{\circ}C$. However, the pressure didn't help the degradation of biomass components. At subcritical temperature range, xylose was first formed by degradation of xylan, which is main hemicellulose component in hardwood species, while cellulose degradation started at the transition zone between sub and supercritical conditions and was remarkably accelerated at the supercritical temperature. In the supercritical water system the maximum yield of monomeric sugars amounts to ca. 7.3% based on oven dried wood weight at $425^{\circ}C$.

  • PDF