• Title/Summary/Keyword: under flow water

Search Result 1,376, Processing Time 0.029 seconds

The Effect of Flow Patterns with Polymer Additivies From Two Phase Flow at Vertical up Ward in Circular Tube (원관내 수직상향 2상유동에서 고분자물질이 유동양식에 미치는 영향)

  • 김재근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.22 no.4
    • /
    • pp.505-514
    • /
    • 1998
  • Flow pattern of air-water two phase flow depends on the conditions of pressure void fraction and channel geometry. We classify the flow pattern by measuring the output signal of the conductivity probe. under the classified flow pattern we mount a visualization equipment on the test section and take pictures. We vary the concentration of pure solvent and polymer to measure local void fraction. We know that the maximum point position of local void fraction distribution move from the center of the pipe to the wall of the pipe as JSL increase when JSA is constant in two phase flow. But we find that the maximum point position of local void friction move from the wal of the pipe to the center of the pipe when polymer concentration increase.

  • PDF

Sanitary Control of Aquarium Tank Water with U.V. Light (자외선을 이용한 활어용 수조수의 위생 대책 수립)

  • CHOI Seung-Tae;PARK Mi-Yeon;CHANG Dong-Suck
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.28 no.4
    • /
    • pp.428-434
    • /
    • 1995
  • The purpose of this study is to develop a sanitary aquarium for the safety slices of raw fish by using U.V. light. Water re-circulating system was composed of two tanks. One of the tanks $(90\times45\times45cm\;in\;size),$ was used for rearing fish and the other $(90\times45\times45cm\;in\;size),$ with 37 pieces of corrugated plastic plates was used for the growth of Nitrosomonas and Nitrobacter to remove ammonia from the water. Consequently, bactericidal effects of U.V. light were examined under the controlled condition of water with flow rate 730m1/sec (water flow thickness: 10mm), the width 41cm of water flow route, and the distance 4.75cm from the lamp to its water bottom, and U.V. light 75W (5 lamps). The water of the aquarium tank will be theroetically circulated 1 cycle per 18 min. In these conditions the bactericidal effect was $85\%$ just after passing through U,V. light and 3 log cycle in aquarium tank water. The count of Vibrio parahaemolyticus just after irradiation was decreased by about over than 3 log cycle. Under the irradiation for 72 hours, viable cell counts in both skin and gill of fish reared were decreased into about 2 log cycle, but there was no significant decrease in viscera. When the temperature of the tank was controlled at about $20-23^{\circ}C$ under the same condition, viable cell counts were reduced about 2 log cycle, and fecal coliforms were reduced about 1 log rycle and 3 log cycle in Crassostrea gigas and Mytilus edulis, respectively.

  • PDF

Development and Operation of 5kW-Class Polymer Electrolyte Membrane Fuel Cell System (5kW급 고분자 연료전지 시스템의 개발과 운전)

  • Chun, Y.G.;Peck, D.H.;Jeon, K.S.;Kim, C.S.;Shin, D.R.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1876-1878
    • /
    • 1999
  • Developed was a 5kW-class polymer electrolyte membrane fuel cell(PEMFC) system comprised of fuel cell stack, fuel processing, thermal and water management subsystems and ancillary equipments. Several large single cells have been fabricated with different gas flow field patterns and paths, and the gas flow field pattern for the stack has been determined based on the single cell performance of thin film membrane electrode assembly (MEA). The PEMFC stack was consisted of 100 cells with an electrode area of $300cm^2$, having serpentine flow pattern. Fuel processing was developed including an autothermal methanol reformer and two preferential CO oxidation reactors. The fuel processing was combined to PEMFC operation system consisted of air compressor and thermal and water management subsystems. The PEMFC stack showed performance of 5kW under the supply of $H_2$ and air, but its performance was lowered to 3.5kW under the supply of reformed gas.

  • PDF

The Application of Geosynthetic Reinforced Soil Method in the Failed Slopes (붕괴사면 복구를 위한 보강토 공법의 적용)

  • Cho, Yong-Seong;Kim, You-Seong;Park, Inn-Joon
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.171-178
    • /
    • 2005
  • It is unavoidable to be formed slopes under special circumstance of Korea where 70% of the whole area are composed of mountains when civil engineering projects such as roads, site developments are increased with industrial development and horizontal expansions of urban area. Moreover, stability of the slopes become one of quite important issues under special meteorological characteristics that over two-thirds of annual average rainfall are concentrated in summer season and the localized torrential downpour are getting more frequent recently. Resulting in these circumstances, partial slope failures by debris flow of the high water content soils are occurred frequently in cutting soil slopes. In this case of debris flow slope failure, slope declination method are selected for their stable recovery because it is impossible to recover entirely by existing recovery methods. Seeding or special grass planting methods are followed separately without exception. The method by which entire recover with bigger stability ratio would be possible and grass planting work would be done simultaneously is developed. In this study, the results of the tests including a real construction history in a failed slope using developed method are described

  • PDF

Boundary Layer Flow Under a Sluice Gate (수직수문하의 경계층흐름)

  • 이정열
    • Water for future
    • /
    • v.27 no.3
    • /
    • pp.95-105
    • /
    • 1994
  • The boundary layer flow under a sluice gate is numerically solved by the random vortex sheet method combined with the vortex-in-cell method in a boundary-fitted coordinate system. The numerical solution shows that the boundary layer developed along the vertical sluice gate wall is the primary cause for the discrepancy in the contraction ratio between the laboratory experiments and inviscid theory; the bottom boundary layer plays much a smaller role in the discrepancy. By dimensional analysis it is concluded that the discrepancy is inversely proportional to the 3/4th power of the gate opening, as analyzed by Benjamin(1956). The results of the numerical simulation and dimensional analysis show a good agreement with experimental results obtained by Benjamin(1956).

  • PDF

Release Pattern of Urea from Metal-urea-clay Hybrid with Montmorillonite and Its Impact on Soil Property

  • Kim, Kwang-Seop;Choi, Choong-Lyeal;Lee, Dong-Hoon;Seo, Young-Jin;Park, Man
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.44 no.4
    • /
    • pp.545-550
    • /
    • 2011
  • Urea intercalated into montmorillonite (MT) exhibits remarkably enhanced N use efficiency, maintaining its fast effectiveness. This study dealt with the release property of urea from metal-urea-clay hybrid with MT (MUCH) under continuous-flow conditions and the cumulative impacts of its successive application on physicochemical properties of soils. Releases of urea were completed within 4 hrs under continuous-flow condition regardless of the types and the leaching solutions. However, urea release property was significantly affected by both the form of fertilizer and the presence of electrolytes in solution. The fast release property of urea from MUCH in continuous-flow condition was not significantly affected by soil properties such as soil pH and soil texture. In addition, its successive application did not lead to any noticeable change in soil physicochemical properties, water stable aggregate rate, water holding capacity and cation exchange capacity in both sandy loam and clay loam soils. Therefore, this study strongly supported that urea intercalated into MT could be applied as fast-effective N fertilizer, in particular for additional N supply.

Experimental Study on the Performance of a CO2 Heat Pump Water Heater under Various Operating Conditions (이산화탄소 급탕 열펌프의 운전조건에 따른 성능 특성에 관한 실험적 연구)

  • Sohn, Dong-Jin;Baek, Chang-Hyun;Heo, Jae-Hyeok;Kang, Hoon;Kim, Yong-Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.4
    • /
    • pp.273-280
    • /
    • 2011
  • In this study, the steady state performance of a $CO_2$ heat pump water heater was measured with a variation of operating conditions such as refrigerant charge amount, compressor frequency, EEV opening, and water mass flow rate. Transient state performance tests were also conducted to investigate major system effects associated with the interaction between the $CO_2$ heat pump water heater and the water tank. Optimum refrigerant charge amount for the system was 1600 g. At compressor frequencies of 50 Hz and 60 Hz, water mass flow rates of 95 kg/h and 105 kg/h, and EEV opening of 8% and 16%, the water heating temperatures were $65^{\circ}C$ and $68^{\circ}C$ and COPs were 3.0 and 2.8, respectively. In the transient condition, the instantaneous COP decreased with an increase in the inlet water temperature.

Diffusion Analysis of the High Temperature and Salinity Water by the 3-D Baroclinic Flow Model (3-D 밀도류모델을 이용한 고온${\cdot}$고염수의 확산해석)

  • Kim, Jong-In;Kim, Hyeon-Ju
    • Journal of Ocean Engineering and Technology
    • /
    • v.13 no.3B
    • /
    • pp.3-13
    • /
    • 1999
  • The diffusion characteristics of the high temperature and salinity water discharged in Chinhae Bay under BMP(Barge-Mounted Plants) desalination processes were simulated to access environmental impact. The 3-D baroclinic flow model is formulated by integrating the basic equations with respect to each control volume and by transforming them into a finite difference form using the space-staggered grid system. With a 3-D baroclinic flow model, the tide-induced and density-induced current was computed and confirmed by comparing with observed data. From the results of numerical experiment, it is expected that the maximum diffusion lengths of the high temperature and salinity which increase $0.6^{circ}C$ and 0.2 after discharging are 1 km and 3.5km, respectively. It may be expected that the discharge has an effect on surrounding area of discharge, but not an effect on whole area of Chinhae Bay.

  • PDF

A Study on Seepage Characteristics in Case of Seaward Seepage Through Sea-dike (역경사 현태를 가진 방조제 성토층 단명에서의 침출현상 연구)

  • Hong, Byung-Man
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.40 no.5
    • /
    • pp.43-51
    • /
    • 1998
  • In design and management of sea0dikes, engineers need to study various transient seepage conditions through dikes not only for the sea water infiltration into dikes due to cyclic rises of sea water level also for the seepage flow out from dikes toward the sea due to cyclic drawdown of sea water level. Characteristics of seepage flow toward the sea from dikes are more complicated than as known and remained unclearly. The case of such seepage flow may be explained by figuring out seepage characteristics in filter as a part of sea-dikes. Filters in most sea-dikes in Korea are inevitably placed with reversely inclined shape due to field construction conditions. Most computer programs for seepage analysis based on the various numerical methods give practically acceptable results, but for the case of reversely inclined section of filters any verification to apply them might be needed. In this study, large scaled model tests were executed to verify and understand seepage flow through earth-filled sea-dikes. The results from numerical analysis and model tests show some remarkable differences in pore pressure distribution under cyclic changes of see level, and some of the results need to be considered in design and construction practices with further study.

  • PDF

A Study on the System Performance Prediction Method of Natural Circulation Solar Hot Water System (자연순환식 태양열 급탕 시스템의 성능 추정 방법에 관한 연구)

  • Youn, Suck-Berm;Chun, Moon-Hyun
    • Solar Energy
    • /
    • v.7 no.2
    • /
    • pp.37-53
    • /
    • 1987
  • This study has been prepared for the purpose of developing the system performance prediction method of natural circulation solar hot water system. The storage tank of the natural circulation solar hot water system equipped with flat-plate solar collector is located at higher elevation than the solar collectors. Therefor, the storage tank temperature distribution formed accordance with configuration of storage tank by flow rate of circulating fluid affect system collection efficiency. In this study measure the storage tank temperature distribution with various experimental system under real sun condition and present the theoretical prediction method of the storage tank temperature. Moreover measure the flow rate not only day-time but also night-time reverse flow rate with die injection visual flow meter. Main conclusion obtain from the present study is as follows; 1) The storage tank temperature distribution above the connecting pipe connection position is the same as that of the fully mixed tank and below the connection position is the same as that of stratified tank. 2) The system performance sensitive to the storage tank temperature distribution. Therefore detailed tank model is necessary. Average storage tank temperature can be calculate 3% and storage tank temperature profile can get less than 10% difference with this model system.

  • PDF