• Title/Summary/Keyword: unconfined compression

Search Result 281, Processing Time 0.025 seconds

Performance of fly ash stabilized clay reinforced with human hair fiber

  • Rekha, L. Abi;Keerthana, B.;Ameerlal, H.
    • Geomechanics and Engineering
    • /
    • v.10 no.5
    • /
    • pp.677-687
    • /
    • 2016
  • Industrialization and urbanization are the two phenomena that are going relentless all over the world. The consequence of this economic success has been a massive increase in waste on one hand and increasing demand for suitable sites for construction on the other. Owing to the surplus raw materials and energy requirement needed for manufacturing synthetic fibers, applications of waste fibers for reinforcing soils evidenced to offer economic and environmental benefits. The main objective of the proposed work is to explore the possibilities of improving the strength of soil using fly ash waste as an admixture and Human Hair Fiber (HHF) as reinforcement such that they can be used for construction of embankments and land reclamation projects. The effect of fiber content on soil - fly ash mixture was observed through a series of laboratory tests such as compaction tests, CBR and unconfined compression tests. From the stress - strain curves, it was observed that the UCC strength for the optimised soil - flyash mixture reinforced with 0.75% human hair fibers is nearly 2.85 times higher than that of the untreated soil. Further, it has been noticed that there is about 7.73 times increase in CBR for the reinforced soil compared to untreated soil. This drastic increase in strength may be due to the fact that HHF offer more pull-out resistance which makes the fibers act like a bridge to prevent further cracking and thereby it improves the toughness which in turn prevent the brittle failure of soil-flyash specimen. Hence, the test results reveal that the inclusion of randomly distributed HHF in soil significantly improves the engineering properties of soil and can be effectively utilized in pavements. SEM analysis explained the change of microstructures and the formation of hydration products that offered increase in strength and it was found to be in accordance with strength tests.

Application of the $\phi=0$ Analysis for Dredged and Reclaimed Ground (준설매립지반에 대한 $\phi=0$ 해석의 적용성)

  • Kim, Ju-Hyun;Jeong, Sang-Kug;Shim, Min-Bo;Lee, Song
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.1
    • /
    • pp.21-27
    • /
    • 2004
  • In this test, there was two-dimensional model loading test implemented for analysis with respect to the problem of evaluating bearing capacity and the application range on the dredged and reclaimed ground, so it was possible to get the following result by comparing a result of loading test and an equation proposed previously. When the difference between average undrained shea. strength by (equation omitted)B of loading board width and the strength under. (equation omitted)B is mere than $\pm50%$, the applicability of Nc(coefficient of bearing capacity where $\phi=0$ analysis is considered in the single layer) was declined. As well, using Nc=5.7, 5.14(coeffcient of bearing capacity where $\phi=0$ analysis is applicable to saturated clay without special limit) for evaluating bearing capacity on the dredged and reclaimed ground causes poor applicability, therefore that seem to be applicable when water content is less than about 75% which makes the unconfined compression test possible.

The Injection Characteristics and Environmental Effects for Grouting Materials Based on Cement (시멘트계 주입재 종류별 주입 특성 및 환경적 영향 연구)

  • 천병식;이재영;서덕동
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.2
    • /
    • pp.159-170
    • /
    • 2003
  • In this study, the mixed design of grout with hish strength.high permeation.high durability and environmental stability as the state of the art in material field was performed. Also, the subjects of grouting, grouting effects for ground conditions, and environmental effects were analyzed. According to these results, the fundamental data will be suggested as a design of grouting in the field application. The physical, mechanical and chemical characteristics with particle shape of the grouts were analyzed. Then, the gel-time of grouts, which is essential for workability and permeation range, were controlled. Also, the laboratory model grouting tests were performed to find the characteristics of solidification, permeation and durability with grouts. The ordinary portland, slag and microcement which have been used in the construction field were evaluated fur the environmental effects. To find the leaching of $Cr^{6+}$characteristics in cement grouts, $Cr^{6+}$ leaching tests were performed for the raw materials. Also, the results of leaching test were shorn by surrounding environment. Then, the unconfined compression strength tests were performed with the homo-gel samples, and the amount of changed $Cr^{6+}$ was measured by curing solution.

Soil Stabilization with time and Rice Husk Ash (Rice husk ash를 이용한 토질안정처리)

  • 민덕기;황광모;김현도;황택진
    • Journal of the Korean Geotechnical Society
    • /
    • v.18 no.5
    • /
    • pp.19-25
    • /
    • 2002
  • In this paper, a laboratory investigation was carried out to change the geotechnical properties of clayey soil with quicklime and rice husk ash for surplus soil strength improvement. The organic content of soils is 8.67%, 6.45% and 3.84% respectively. The geotechnical properties of treated soil were evaluated by a series of laboratory unconfined compression test, consolidation test and etc. The test results indicated that the presence of RHA enhanced the efficiency of lime stabilization. Especially, the increase in strength is very high at the first stage, while the significant improvement occurs in a sample C with organic content of 3.84%. These results can be identified by X-ray diffraction(XRD) and scanning electron microscope(SEM). The results of consolidation test indicate that the presence of RHA with lime reduces the properties of swelling of soil. Thus, it was verified that the addition of RHA is more effective than using only lime for soil stabilization.

Application of Particulate Grouts for Improving Strength Characteristics of Municipal Wastes (도시폐기물의 강도특성 향상을 위한 현탁액 주입의 응용)

  • Cheon, Byeong-Sik;Park, Hong-Gyu;Jang, Yeon-Su
    • Geotechnical Engineering
    • /
    • v.13 no.1
    • /
    • pp.59-74
    • /
    • 1997
  • This paper presents the results of the geotechnical investigation and settlement analysis of a finished waste landfill to find the possibility of the site as a construction area. Also, the variations of the strength of the municipal waste after mixing with the several types of the particulate grouts are investigated. The materials of the grouts used in the experiment are Quick Lime, Portland Cement, Slag Cement and Geocrete Cement. The results of the geotechnical investigation show that the maximum dry unit weight of the waste becomes lower and optimum moisture content higher as the age of the disposed waste is younger and the organic content is higher. The thickness of the predicted differential settlements of the waste fill has large difference from location to location and the unconfined compression strength of the grout mixed waste from the experiment was higher in the order of Geocrete Cement, Slag Cement, Portland Cement and Quick Lime.

  • PDF

A Study on the Application and Grouting Effects of Akali-Silicasol Grout Material from Field Test (현장시험을 통한 알칼리성 실리카졸 주입재의 적용성 및 주입효과에 대한 연구)

  • Kim, Younghun;Lee, Jinkyu;Yang, Hyungchil;Chun, Byungsik
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.8
    • /
    • pp.5-13
    • /
    • 2012
  • This research have investigated the application and the injection effect of the alkaline silicasol grouting materia (which is) recently developed. To compare the engineering characteristics of the alkaline silicasol which is formed with 3D-gel and the sodium silicate, it have studied the strength and environmental effects through the laboratory test, and field application was investigated with a review of the injection effect and waterproof through the field test. As a result of the laboratory test, unconfined compression strength of alkaline silicasol was 5 times more than sodium silicate. As a result of the leaching test, a total amount of the eluviated elements was very small, it considered the environment-friendly material. As a result of the field test, considerable reduction of the coefficient of permeability at the hydraulic layer was confirmed, and it could secure that the coefficient of permeability showed a lower than standard value of $10^{-5}cm/sec$.

Strength and Leaching Characteristics of Water Sludge-added Lightweight Soil Considering Reinforcing Material and Layer (정수슬러지를 혼합한 경량토의 보강에 따른 강도 및 용출 특성 분석)

  • Yun, Daeho;Lee, Byunghun;Kim, Yuntae
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.8
    • /
    • pp.75-84
    • /
    • 2012
  • In this paper, strength and leaching characteristics of water sludge-added lightweight soils(WALS) considering reinforcing materials(waste fishing net, glue treated waste fishing net and geogrid) and layer(1 or 2 layer) were investigated using unconfined compression test and leaching test. Several specimens of water sludge-added lightweight soil consisted of water sludge, cement, and bottom ash were prepared according to flowability. Reinforcing material added into these specimens were waste fishing net and geogrid. A glue treated waste fishing net was also added in order to increase interlocking between soil mixture and waste fishing net. Strength increased in the order of WALS reinforced by waste fishing net, glue treated waste fishing net, and geogrid. Strength of specimen with double layer-reinforcing material was greater than that of specimen with single layer reinforcing material. Leaching result of WALS was also satisfied with standard of ministry of environment.

Investigations of different steel layouts on the seismic behavior of transition steel-concrete composite connections

  • Qi, Liangjie;Xue, Jianyang;Zhai, Lei
    • Advances in concrete construction
    • /
    • v.8 no.3
    • /
    • pp.173-185
    • /
    • 2019
  • This article presents a comparative study of the effect of steel layouts on the seismic behavior of transition steel-concrete composite connections, both experimental and analytical investigations of concrete filled steel tube-reinforced concrete (CFST-RC) and steel reinforecd concrete-reinforced concrete (SRC-RC) structures were conducted. The steel-concrete composite connections were subjected to combined constant axial load and lateral cyclic displacements. Tests were carried out on four full-scale connections extracted from a real project engineering with different levels of axial force. The effect of steel layouts on the mechanical behavior of the transition connections was evaluated by failure modes, hysteretic behavior, backbone curves, displacement ductility, energy dissipation capacity and stiffness degradation. Test results showed that different steel layouts led to significantly different failure modes. For CFST-RC transition specimens, the circular cracks of the concrete at the RC column base was followed by steel yielding at the bottom of the CFST column. While uncoordinated deformation could be observed between SRC and RC columns in SRC-RC transition specimens, the crushing and peeling damage of unconfined concrete at the SRC column base was more serious. The existences of I-shape steel and steel tube avoided the pinching phenomenon on the hysteresis curve, which was different from the hysteresis curve of the general reinforced concrete column. The hysteresis loops were spindle-shaped, indicating excellent seismic performance for these transition composite connections. The average values of equivalent viscous damping coefficients of the four specimens are 0.123, 0.186 and 0.304 corresponding to the yielding point, peak point and ultimate point, respectively. Those values demonstrate that the transition steel-concrete composite connections have great energy dissipating capacity. Based on the experimental research, a high-fidelity ABAQUS model was established to further study the influence of concrete strength, steel grade and longitudinal reinforcement ratio on the mechanical behavior of transition composite connections.

Backfill Materials for Underground Facility with Recycling Materials - Quantification of Design Parameters (재활용재료를 이용한 지하매설물용 뒤채움재 - 설계입력변수 정량화)

  • Lee, Kwan-Ho;Kim, Seong-Kyum
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.11 no.3
    • /
    • pp.91-96
    • /
    • 2011
  • The design, construction and management of underground facilities as infrastructure of nation should be properly carried out. One of reasons for underground facilitie's failure is a non-proper construction of backfill materials. This is common for circular underground pipes. A non-proper compaction is the cause of settlement and decrease of performance of underground facilities. The use of controlled low strength materials is an alternative to reduce the couple of failure problems. The flowability, self-cementation, and non-compaction are the major advantages to use the controlled low strength materials. In this research, couple of recycled materials, such as in-situ soil, water-treatment sludge, and crumb rubbers, were adopted. The basic properties of each materials were determined according to KS or ASTM. Also, couple of laboratory tests were carried out to get the design parameters for geotechnical and roadway area.

A Study on the Strength Properties and Life Cycle Assessment of Recycled Fine Aggregate Concrete (순환잔골재 혼입 콘크리트의 강도 특성 및 전과정 환경영향 평가 연구)

  • Choi, Won-Young;Kim, Sang-Heon;Lee, Sea-Hyun;Jeon, Chan-Soo
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.7 no.2
    • /
    • pp.123-130
    • /
    • 2019
  • The purpose of this study is to confirm the strength characteristics of concrete according to the mixing ratio of recycled fine aggregates and to use it as basic data for the use of recycled fine aggregates in concrete. For this purpose, the target design compression strength was set at 27MPa. Considering practical use of recycled aggregate, the mixing ratio of recycled fine aggregate was set at 0, 30, 60, and 100%, and the unconfined concrete and hardened concrete were tested. The LCA method was used to evaluate the environmental impact of recycled fine aggregate concrete, and the effectiveness of recycled fine aggregate in the production of concrete was verified.