• Title/Summary/Keyword: ultrasound radiation

Search Result 144, Processing Time 0.028 seconds

Brachytherapy of Uveal Melanomas with Ruthenium-106 Plaques

  • Belaid, Asma;Nasr, Chiraz;Jmour, Omar;Cherif, Aziz;Kochbati, Lotfi;Bouguila, Hedi;Besbes, Mounir;Benna, Farouk
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.12
    • /
    • pp.5281-5285
    • /
    • 2016
  • Background: Brachytherapy is the most commonly used conservative treatment for the uveal melanoma. The aim of this study was to evaluate therapeutic results of Ruthenium-106 plaque brachytherapy in the management of localized uveal melanoma cases. Methods: We reviewed retrospectively the clinical records of all patients treated in our department for an uveal melanoma, undergoing Ruthenium-106 plaque brachytherapy, from January 1996 to December 2015. We focused on clinical features, therapeutic characteristics, local and distant tumor control and side effects. Results: Nineteen patients were enrolled in our study. Mean age was 56.2 years (28-79) and the sex ratio was 1.37:1 males to females. Diagnosis was made on the basis of ophthalmological clinical examination, angiography, ultrasound and/or magnetic resonance. Median tumor diameter was 9.7 mm (6-13) and median thickness 4.4 mm (2.5-8). The dose of Ruthenium-106 plaque brachytherapy prescribed to the apex of each tumor was 70 Gy in all cases. The median radiation dose to the sclera surface was 226.4 Gy (range: 179.6-342.3) and the median total application time 115.2 hours (range: 27 to 237). After a median follow-up of 61.5 months, local control was achieved in 17 patients (89%): 16 demonstrated a partial tumor response and 1 tumor stabilization. Two patients suffered local progression leading to enucleation, one dying of hepatic metastasis. Radiation-induced complications were cataracts in 3 cases and vitreal hemorrhage in 2. Conclusion: Ruthenium-106 plaque brachytherapy is an efficient treatment for localized uveal melanoma, offering good local control with low toxicity.

Effects of a Carbohydrase Mixture, Ultrasound, and Irradiation Treatments on the Physical Properties of Defatted Mustard Meal-based Edible Films (탈지 겨자씨로 제조한 가식성 생고분자 필름의 물리적 특성에 대한 탄수화물 가수분해 효소 혼합체, 초음파, 그리고 방사선 처리의 효과)

  • Yang, Hee-Jae;Noh, Bong-Soo;Kim, Jae-Hun;Min, Sea-C.
    • Korean Journal of Food Science and Technology
    • /
    • v.43 no.1
    • /
    • pp.30-38
    • /
    • 2011
  • Effects of depolymerization treatments of a carbohydrase mixture (CM), ultrasound, and irradiation on the physical properties of defatted mustard meal-based edible films (DMM films) were investigated. DMM hydrocolloids were added to CM (0.42% (w/w solution)), treated by ultrasound (500-700 W, 10-30 min) or ${\gamma}$-ray (40-100 kGy) to prepare film-forming solutions. Films were formed by drying. The CM treatment at 0.42% (w/w), pH 5.5, and 40-$50^{\circ}C$ with a 0.5 hr incubation time resulted in the highest colloidal stability in the film-forming solution. The depolymerization treatments did not dramatically change the water vapor permeability of the films. The solubility of the film decreased up to 53.1% by the CM treatment. The ultrasound treatment (700 W-30 min) decreased tensile strength and elongation. The ultrasound treatment (600 W-20 min) resulted in more compact and uniform structures of the films. Flavor profiles were differentiated by the power level and the time of the ultrasound treatment.

Assessment of Degradation by Corrosion Fatigue of TMCP Steel using a Backward Radiated Ultrasound (후방복사 초음파를 이용한 TMCP강의 부식피로 손상평가)

  • Kim, Y.H.;Bae, D.H.;Park, J.H.;Yu, H.J.;Kwon, S.D.;Song, S.J.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.23 no.4
    • /
    • pp.349-355
    • /
    • 2003
  • Material degradation due to corrosion fatigue was evaluated nondestructively using backward radiated Rayleigh surface wave. h corrosion fatigue test was carried out for the specimens made of thermo-mechanically controlled process steel in 3.5wt.% NaCl solution at $25^{\circ}C$. The backward radiation profile, which is the amplitude variation of backward radiated ultrasound according to the incident angle, of the specimens were measured in water at room temperature after the corrosion fatigue test. The velocity of Rayleigh surface wave, determined from the incident angle at which the profile of the backward radiated ultrasound became maximum, decreased for the specimen that had the large number of cycles to failure in the corrosion fatigue test. This fact implies that the corrosion degradation occurred at specimen surface in this specific test is dominantly dependant on the me exposed to corrosion environment. The result observed in the present work demonstrates the high potential of backward radiated Rayleigh surface wave as a tool for nondestructive evaluation of corrosion degradation of aged materials.

The Potential Usefulness of Magnetic Resonance Guided Focused Ultrasound for Obsessive Compulsive Disorders

  • Jung, Hyun Ho;Chang, Won Seok;Kim, Se Joo;Kim, Chan-Hyung;Chang, Jin Woo
    • Journal of Korean Neurosurgical Society
    • /
    • v.61 no.4
    • /
    • pp.427-433
    • /
    • 2018
  • Obsessive compulsive disorder is a debilitating condition characterized by recurrent obsessive thoughts and compulsive reactions. A great portion of the obsessive compulsive disorder (OCD) patients are managed successfully with psychiatric treatment such as selective serotonin-reuptake inhibitor and cognitive behavioral psychotherapy, but more than 10% of patients are remained as non-responder who needs neurosurgical treatments. These patients are potential candidates for the neurosurgical management. There had been various kind of operation, lesioning such as leucotomy or cingulotomy or capsulotomy or limbic leucotomy, and with advent of stereotaxic approach and technical advances, deep brain stimulation was more chosen by neurosurgeon due to its characteristic of reversibility and adjustability. Gamma knife radiosurgery are also applied to make lesion targeting based on magnetic resonance (MR) imaging, but the complication of adverse radiation effect is not predictable. In the neurosurgical field, MR guided focused ultrasound has advantage of less invasiveness, real-time monitored procedure which is now growing to attempt to apply for various brain disorder. In this review, the neurosurgical treatment modalities for the treatment of OCD will be briefly reviewed and the current state of MR guided focused ultrasound for OCD will be suggested.

DEFECT DETECTION WITHIN A PIPE USING ULTRASOUND EXCITED THERMOGRAPHY

  • Cho, Jai-Wan;Seo, Yong-Chil;Jung, Seung-Ho;Kim, Seung-Ho;Jung, Hyun-Kyu
    • Nuclear Engineering and Technology
    • /
    • v.39 no.5
    • /
    • pp.637-646
    • /
    • 2007
  • An UET (ultrasound excited thermography) has been used for several years for a remote non-destructive testing in the automotive and aircraft industry. It provides a thermo sonic image for a defect detection. A thermograhy is based On a propagation and a reflection of a thermal wave, which is launched from the surface into the inspected sample by an absorption of a modulated radiation. For an energy deposition to a sample, the UET uses an ultrasound excited vibration energy as an internal heat source. In this paper the applicability of the UET for a realtime defect detection is described. Measurements were performed on two kinds of pipes made from a copper and a CFRP material. In the interior of the CFRP pipe (70mm diameter), a groove (width - 6mm, depth - 2.7mm, and length - 70mm) was engraved by a milling. In the case of the copper pipe, a defect was made with a groove (width - 2mm, depth - 1mm, and length - 110 mm) by the same method. An ultrasonic vibration energy of a pulsed type is injected into the exterior side of the pipe. A hot spot, which is a small area around the defect was considerably heated up when compared to the other intact areas, was observed. A test On a damaged copper pipe produced a thermo sonic image, which was an excellent image contrast when compared to a CFRP pipe. Test on a CFRP pipe with a subsurface defect revealed a thermo sonic image at the groove position which was a relatively weak contrast.

Evaluation of U-Net Based Learning Models according to Equalization Algorithm in Thyroid Ultrasound Imaging (갑상선 초음파 영상의 평활화 알고리즘에 따른 U-Net 기반 학습 모델 평가)

  • Moo-Jin Jeong;Joo-Young Oh;Hoon-Hee Park;Joo-Young Lee
    • Journal of radiological science and technology
    • /
    • v.47 no.1
    • /
    • pp.29-37
    • /
    • 2024
  • This study aims to evaluate the performance of the U-Net based learning model that may vary depending on the histogram equalization algorithm. The subject of the experiment were 17 radiology students of this college, and 1,727 data sets in which the region of interest was set in the thyroid after acquiring ultrasound image data were used. The training set consisted of 1,383 images, the validation set consisted of 172 and the test data set consisted of 172. The equalization algorithm was divided into Histogram Equalization(HE) and Contrast Limited Adaptive Histogram Equalization(CLAHE), and according to the clip limit, it was divided into CLAHE8-1, CLAHE8-2. CLAHE8-3. Deep Learning was learned through size control, histogram equalization, Z-score normalization, and data augmentation. As a result of the experiment, the Attention U-Net showed the highest performance from CLAHE8-2 to 0.8355, and the U-Net and BSU-Net showed the highest performance from CLAHE8-3 to 0.8303 and 0.8277. In the case of mIoU, the Attention U-Net was 0.7175 in CLAHE8-2, the U-Net was 0.7098 and the BSU-Net was 0.7060 in CLAHE8-3. This study attempted to confirm the effects of U-Net, Attention U-Net, and BSU-Net models when histogram equalization is performed on ultrasound images. The increase in Clip Limit can be expected to increase the ROI match with the prediction mask by clarifying the boundaries, which affects the improvement of the contrast of the thyroid area in deep learning model learning, and consequently affects the performance improvement.

Research and Development for Decontamination System of Spent Resin in Hanbit Nuclear Power Plant (한빛원전 폐수지 제염공정 개발연구)

  • Sung, Gi Hong
    • Journal of Radiation Industry
    • /
    • v.9 no.4
    • /
    • pp.217-221
    • /
    • 2015
  • When reactor coolant leaks occur due to cracks of a steam generator's tube, radioactive materials contained in the primary cooling water in nuclear power plant are forced out toward the secondary systems. At this time the secondary water purification resin in the ion exchange resin tower of the steam generator blowdown system is contaminated by the radioactivity of the leaked radioactive materials, so we pack this in special containers and store temporarily because we could not dispose it by ourselves. If steam generator tube leakage occurs, it produces contaminated spent resins annually about 5,000~7,000 liters. This may increase the amount of nuclear waste productions, a disposal working cost and a unit price of generating electricity in the plant. For this reasons, it is required to develop a decontamination process technique for reducing the radioactive level of these resins enough to handle by the self-disposal method. In this research, First, Investigated the structure and properties of the ion exchange resin used in a steam generator blowdown system. Second, Checked for a occurrence status of contaminated spent resin and a disposal technology. Third, identified the chemical characteristics of the waste radionuclides of the spent resin, and examined ionic bonding and separation mechanism of radioactive nuclear species and a spent resin. Finally, we carried out the decontamination experiment using chemicals, ultrasound, microbubbles, supercritical carbon dioxide to process these spent resin. In the case of the spent resin decontamination method using chemicals, the higher the concentration of the drug decontamination efficiency was higher. In the ultrasound method, foreign matter of the spent resin was removed and was found that the level of radioactivity is below of the MDA. In the microbubbles method, we found that the concentration of the radioactivity decreased after the experiment, so it can be used to the decontamination process of the spent resin. In supercritical carbon dioxide method, we found that it also had a high decontamination efficiency. According to the results of these experiments, almost all decontamination method had a high efficiency, but considering the amounts of the secondary waste productions and work environment of the nuclear power plant, we judged the ultrasound and supercritical carbon dioxide method are suitable for application to the plant and we established the plant applicable decontamination process system on the basis of these two methods.

The Change of Blood Flow Velocity of Radial Artery after Linear Polarized Infrared Light Radiation near the Stellate Ganglion: Comparing with the Stellate Ganglion Block (성상신경절 부위의 직선편광 근적외선 조사 후 요골동맥에서의 혈류속도의 변화: 성상신경절 차단술과의 비교)

  • Han, Soung-Moon;Lee, Sang-Chul
    • The Korean Journal of Pain
    • /
    • v.14 no.1
    • /
    • pp.37-40
    • /
    • 2001
  • Background: It had been reported by authors that linear polarized infrared light radiation (Superizer: SL) near the stellate ganglion had a similar effect on the change of skin temperature of hand compared with the stellate ganglion block (SGB). We hypothesized that this was due to dilatation of vessels and an increased blood flow. The aim of this study was to measure the velocity of blood flow in peripheral vessels after linear polarized infrared light radiation near the stellate ganglion and to compare the effect of SL with that of SGB using local anesthetics. Methods: Forty patients whose clinical criteria were matched for the symptoms of SGB were selected for study. We radiated the stellate ganglion by linear polarized infrared light radiation and measured the blood flow of radial artery using Ultrasound Doppler blood flow meter before and after 10, 20 and 30 minutes post-radiation. After 3 days, SGB was performed using 8 ml of 1% mepivacaine to the same patient, and the radial artery blood flow was measured in the same manner. Results: The blood flow velocity was increased by 40% and 27% at 10 min and 20 min after SL and by 42% and 41% at 10 min and 20 min after SGB. However, there was no statistically significant difference in blood flow velocity between SGL and SGB. Conclusions: We could conclude that linear polarized radiation is a clinically simple and useful noninvasive therapeutic tool in clinical area.

  • PDF

Spectral Backward Radiation Profile (주파수 대역별 후방복사 프로파일)

  • Kim, Hak-Joon;Kwon, Sung-Duk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.25 no.5
    • /
    • pp.362-367
    • /
    • 2005
  • Ultrasonic backward radiation profile is frequency-dependent when the incident region has deptional gradient of acoustical properties or multi-layers. Until now, we have measured the profiles of principal frequencies of an used transducers so that it was not easy to characterize the frequency dependence of the SAW(surface acoustic wave) from the backward radiation profile. We tried to measure the spectral backward radiation profiles using DFP(digital filer package) in a Lecroy DSO(digital storage oscilloscope). The measured spectral profiles showed that the steel specimen of #1200 surface treatment have 2% SAW velocity dispersion of the loaded case and the severly rusty steel specimen have the very big changes in the shape and pattern of the spectral profile. It is concluded that the spectral backward radiation profiles could be very effective tool to evaluate the frequency dependence of surface area.

Actual Use of Internet in Curriculum Study of Students in Radiology (방사선 재학생 전공교과목 학습에서 인터넷 활용 실태)

  • Kim, Min-Cheol;Huang, Yuxin;Choi, Ji Hoon;Jung, Hong Ryang;Park, Hae-Ri;Yang, Oh-Nam
    • Journal of radiological science and technology
    • /
    • v.41 no.5
    • /
    • pp.487-491
    • /
    • 2018
  • The purpose of this study was to analyze questionnaires of 161 college students attending radiology departments in order to investigate the actual condition of internet use of radiology students. As a result, 95% of college students using the Internet showed 5.8% of general knowledge, 56.9% of radiation major, and 45.8% of general education. In the field of Internet use, basic medicine was 71.2%, anatomy 59.5% and physiology 51.6%. Radiation theory was 39.9% in radiation physics, 31.4% in radiation biology, and 18.3% in radiation management. The radiological applications were followed by radiography and radiography in order of 31.4% and 20.3%, respectively. The radiological imaging was 45.8%, MRI was 37.9%, CT was 37.3%, ultrasound was 24.2%, And radiation nuclear medicine 25.5%. The results of the descriptive statistics of the satisfaction of the contents using the Internet media showed that the overall satisfaction was below 2.5 Based on the results of this study, it is necessary to develop a program with high accessibility to provide various opportunities for internet-based opportunities to increase the academic achievement value of major subjects through the internet and to solve the difficulties in the major subject.