• Title/Summary/Keyword: ultrasound radiation

Search Result 145, Processing Time 0.026 seconds

An Optimization Method of Measuring Heart Position in Dynamic Myocardial Perfusion SPECT with a CZT-based camera (동적 심근관류 SPECT에서 심장의 위치 측정방법에 대한 고찰)

  • Seong, Ji Hye;Lee, Dong Hun;Kim, Eun Hye;Jung, Woo Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.1
    • /
    • pp.75-79
    • /
    • 2019
  • Purpose Cadmium-zinc-telluride (CZT) camera with semiconductor detector is capable of dynamic myocardial perfusion SPECT for coronary flow reserve (CFR). Image acquisition with the heart positioned within 2 cm in the center of the quality field of view (QFOV) is recommended because the CZT detector based on focused multi-pinhole collimators and is stationary gantry without rotation. The aim of this study was to investigate the optimal method for measuring position of the heart within the center of the QFOV when performing dynamic myocardial perfusion SPECT with the Discovery NM 530c camera. Materials and Methods From June to September 2018, 45 patients were subject to dynamic myocardial perfusion SPECT with D530c. For accurate heart positioning, the patient's heart was scanned with a mobile ultrasound and marked at the top of the probe where the mitral valve (MV) was visible in the parasternal long-axis view (PLAX). And, the marked point on the patient's body matched with the reference point indicated CZT detector in dynamic stress. The heart was positioned to be in the center of the QFOV in rest. The coordinates of dynamic stress and rest were compared statistically. Results The coordinates of the dynamic stress using mobile ultrasound and those taken of the rest were recorded for comparative analysis with regard to the position of the couch and analyzed. There were no statistically significant differences in the coordinates of Table in & out, Table up & down, and Detector in & out (P > 0.05). The difference in distance between the 2 groups was measured at $0.25{\pm}1.00$, $0.24{\pm}0.96$ and $0.25{\pm}0.82cm$ respectively, with no difference greater than 2 cm in all categories. Conclusion The position of the heart taken using mobile ultrasound did not differ significantly from that of the center of the QFOV. Therefore, The use of mobile ultrasound in dynamic stress will help to select the correct position of the heart, which will be effective in clinical diagnosis by minimizing the image quality improvement and the patient's exposure to radiation.

Position Control of Micro Particles in a Fluid Flow Using Ultrasonic Standing Wave (정재초음파를 이용한 유동중 미세 입자 위치 제어)

  • Cho, Seung-Hyun;Seo, Dae-Cheol;Ahn, Bong-Young;Kim, Ki-Bok;Kim, Yong-Il
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.2
    • /
    • pp.131-136
    • /
    • 2008
  • Using ultrasonic standing waves, micro particles submerged or flowing in fluid can be manipulated. Due to acoustic radiation force of ultrasound, particles are forced to move to pressure nodal or antinodal lines. In this work, we propose a method to control the position of micro particle in a flow by adjusting the frequency of the standing wave. To this end, standing wave field generation system including a few millimeter thick micro channel was established using an immersible ultrasonic transducer. The present generation system works valid in a frequency range between 2.0 MHz and 2.5 MHz. We observed the SiC particles in water moved to pressure nodal lines by the standing wave. The effect of the channel thickness and operating frequency was also investigated. Interestingly, it was shown that the operating frequency have a close relation with the location of the pressure nodal line. Consequently, it fan be said that the position of particle movement rail be controlled by adjusting the ultrasound frequency. The maximum range of the controllable position was about 261 micrometers under the given condition. The resulted observations reveal the possibility of various applications of the ultrasonic standing wave to the manipulation of particles submerged in a fluid.

Analysis of Hematological Factor to Predict of the Gallbladder Stone in Abdominal Ultrasound Images (복부초음파 영상에서 담낭담석을 예측하는 혈액학적 수치의 분석)

  • An, Hyun;Hwang, Chul-Hwan;Im, In-chul
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.3
    • /
    • pp.131-137
    • /
    • 2017
  • This study investigated the risk factor of Gallbladder stone in Busan and Kyungnam area. The subjects of the experiment was performed with patients by abdominal ultrasonography among the patients who came to the P hospital from June 2016 to December 2016. Among them, risk factors were analyzed on 353 people at the same time when abdominal ultrasonography and hematological test. The statistical analysis of risk factors related to the Gallbladder stone was performed by independent t-test and chi-square test. In consider of difference verification result for calculations odds ratio about independent variables, multiple logistic regression analysis to conduct verify adequacy by calculating forecasting model from variable. As a result, Gallbladder stone risk factors have relevance to age ${\gamma}GTP$ with probability model and values to calculated. Age was showed sensitivity 49.7%, specificity 82.2%, receiver operating characteristic area under curve 0.724. Forecasting probability sensitivity 69.3%, specificity 62.4%, receiver operating characteristic area under curve 0.699 showed, ${\gamma}GTP$ confirmed validity of forecasting model.

Analysis of Risk factors & Morphological Ultrasound Image for Gallbladder Polyp in Adults Living in Busan and Gyeongnam Provinces (부산·경남 지역 성인의 담낭용종 위험인자 및 초음파 영상의 형태학적 분석)

  • An, Hyeon;Hwang, Chul-Hwan;Ko, Sung-Jin;Kim, Chang-Soo
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.353-359
    • /
    • 2016
  • This study were to evaluate risk factors of GB polpy in Busan and Gyeongnam area. This study was performed with patients by abdominal ultrasonography among the patients who came to the P hospital from January to May 2016. Among them, risk factors were analyzed on 399 people at the same time when abdominal ultrasonography and hematological test. The statistical analysis of risk factors related to the GB ployp was performed by independent t-test and chi-square test. In consider of difference verification result for calculations odds ratio about independent variables, multiple logistic regression analysis to conduct verify adequacy by calculating forecasting model from variable. As a result, GB polyp risk factors have relevance to male, HBsAg positive, triglyceride. GB polyp risk factors confirmed to male, HBsAg positive, triglyceride were calculated forecasting model and forecasting probability value. Forecasting probability sensitivity 61.0%, specificity 76.8%, ROC area under curve 0.735 showed, it confirmed validity of forecasting model. When analyzing the GB polyps morphologically, among the GB polyp types observed from abdominal ultrasonography, the hyperechoic and homogeneous pattern with neck was the largest as shown from 27.5% and two GB polyps were shown most from 38%, sizes were shown most by maximum diameter, 5 to 10mm from 53%. As a disease accompany with GB polyp showed mild fatty liver(23%), diffuse hepatopathy(21%).

Radial Probe Endobronchial Ultrasound Using Guide Sheath-Guided Transbronchial Lung Biopsy in Peripheral Pulmonary Lesions without Fluoroscopy

  • Hong, Kyung Soo;Ahn, Heeyun;Lee, Kwan Ho;Chung, Jin Hong;Shin, Kyeong-Cheol;Jin, Hyun Jung;Jang, Jong Geol;Lee, Seok Soo;Jang, Min Hye;Ahn, June Hong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.84 no.4
    • /
    • pp.282-290
    • /
    • 2021
  • Background: Radial probe endobronchial ultrasound-guided transbronchial lung biopsy (RP-EBUS-TBLB) has improved the diagnostic yield of bronchoscopic biopsy of peripheral pulmonary lesions (PPLs). The diagnostic yield and complications of RP-EBUS-TBLB for PPLs vary depending on the technique, such as using a guide sheath (GS) or fluoroscopy. In this study, we investigated the utility of RP-EBUS-TBLB using a GS without fluoroscopy for diagnosing PPLs. Methods: We retrospectively reviewed data from 607 patients who underwent RP-EBUS of PPLs from January 2019 to July 2020. TBLB was performed using RP-EBUS with a GS without fluoroscopy. The diagnostic yield and complications were assessed. Multivariable logistic regression analyses were used to identify factors affecting the diagnostic yields. Results: The overall diagnostic accuracy was 76.1% (462/607). In multivariable analyses, the size of the lesion (≥20 mm; odds ratio [OR], 2.06; 95% confidence interval [CI], 1.27-3.33; p=0.003), positive bronchus sign in chest computed tomography (OR, 2.30; 95% CI, 1.40-3.78; p=0.001), a solid lesion (OR, 2.40; 95% CI, 1.31-4.41; p=0.005), and an EBUS image with the probe within the lesion (OR, 6.98; 95% CI, 4.38-11.12; p<0.001) were associated with diagnostic success. Pneumothorax occurred in 2.0% (12/607) of cases and chest tube insertion was required in 0.5% (3/607) of patients. Conclusion: RP-EBUS-TBLB using a GS without fluoroscopy is a highly accurate diagnostic method in diagnosing PPLs that does not involve radiation exposure and has acceptable complication rates.

Development of Respiration Gating RT Technique using Moving Phantom and Ultrasound Sensor: a feasibility study (동 팬텀과 초음파 센서를 이용한 호흡운동 조절 방사선치료 기술 개발)

  • Lee, Suk;Lee, Sang-Hoon;Shin, Dong-Ho;Yang, Dae-Sik;Choi, Myung-Sun;Kim, Chul-Yong
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2004.11a
    • /
    • pp.122-125
    • /
    • 2004
  • In radiotherapy of tumors in liver, enough planning target volume (PTV) margins are necessary to compensate breathing-related movement of tumor volumes. To overcome the problems, this study aims to obtain patients' body movements by using a moving phantom and an ultrasonic sensor, and to develop respiration gating techniques that can adjust patients' beds by using reversed values of the data obtained. The phantom made to measure patients' body movements is composed of a microprocessor (BS II, 20 MHz, 8K Byte), a sensor (Ultra-Sonic, range 3 cm ${\sim}$3 m), host computer (RS232C) and stepping motor (torque 2.3Kg) etc., and the program to control and operate it was developed. The program allows the phantom to move within the maximum range of 2 cm, its movements and corrections to take place in order, and x, y and z to move successively. After the moving phantom was adjusted by entering random movement data(three dimensional data form with distance of 2cm), and the phantom movements were acquired using the ultra sonic sensor, the two data were compared and analyzed. And then, after the movements by respiration were acquired by using guinea pigs, the real-time respiration gating techniques were drawn by operating the phantom with the reversed values of the data. The result of analyzing the acquisition-correction delay time for the three types of data values and about each value separately shows that the data values coincided with one another within 1% and that the acquisition-correction delay time was obtained real-time (2.34 ${\times}$ 10$^{-4}$sec). This study successfully confirms the clinic application possibility of respiration gating techniques by using a moving phantom and an ultra sonic sensor. With ongoing development of additional analysis system, which can be used in real-time set-up reproducibility analysis, it may be beneficially used in radiotherapy of moving tumors.

  • PDF

Reproducibiity of setup error for prostate cancer by ultrasound image-guided radiation therapy (전립선암에 대한 초음파 영상유도 방사선치료의 Setup 오차 분석을 통한 재현성 평가)

  • Park, Sung Yong;Lim, Seung Kyu;Si, Myoung Geun;Lee, Ji Hae;Kim, Jong Yeol;Cho, Eun Joo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.2
    • /
    • pp.75-81
    • /
    • 2017
  • Purpose: To evaluate the reproducibility of image-guided radiotherapy using ultrasonography which is non-invasive, without radiation exposure for prostate cancer patients. Materials and Methods: We analyzed the setup variation of 1,105 images for 26 prostate cancer patients and the mean, standard deviation and 3D-error in AP, RL and SI directions. Setup variations were classified 0-1 mm, 1-3 mm, 3-5 mm, 5 mm and more. Results: The mean and standard deviation of setup variation in AP, RL and SI directions was $1.87{\pm}1.36mm$, $1.73{\pm}1.22mm$ and $2.01{\pm}1.40mm$. The 3D-error in AP, RL and SI directions was $3.63{\pm}1.63mm$. The frequency of setup variation in AP direction was 29 % in the range from 0 mm to 1 mm, 50.2 % in the range from 1 mm to 3 mm, 19.6 % in the range from 3 mm to 5 mm and 1.3 % in the range of 5 mm or more. In RL direction, the frequency was 31.3 % in the range from 0 mm to 1 mm, 52.5 % in the range from 1 mm to 3 mm, 15.8 % in the range from 3 mm to 5 mm and 0.5 % in the range of 5 mm or more. SI direction, the frequency of errors in the range from 0 mm to 1 mm was 26.3 %, 50.2 % in the range from 1 mm to 3 mm, 22.4 % in the range from 3 mm to 5 mm, and 1.1 % in the range of 5 mm or more. Conclusion: The setup error was highest in the SI direction of $2.01{\pm}1.40mm$. The frequency in each direction was the highest in more than 50 % in the range from 1 mm to 3 mm. $Clarity^{TM}$ Auto scan is possible to monitoring the motion of the prostate during the treatment and to repositioning the patient. In conclusion real-time image-guided radiotherapy using ultrasonography will be increase the reproducibility of radiation therapy.

  • PDF

Quantitative Analysis of Enlarged Cervical Lymph Nodes with Ultrasound Elastography

  • Zhang, Jun-Peng;Liu, Hua-Yan;Ning, Chun-Ping;Chong, Jing;Sun, Yong-Mei
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.16
    • /
    • pp.7291-7294
    • /
    • 2015
  • Purpsoe: To investigate the diagnostic value of quantitative analysis of a tissue diffusion and virtual touch tissue imaging quantification (VTIQ) technique with acoustic radiation force impulse (ARFI) elastography for assessing enlarged cervical lymph nodes. Materials and Methods: Fifty-six enlarged cervical lymph nodes confirmed by pathologic diagnoses were covered in the study. According to the results of pathologic diagnosis, patients were classified into benign and malignant groups. All the patients were examined by both conventional ultrasonography and elastography. AREA% and shear wave velocity (SWV) in ROI of different groups were calculated and compared using ROC curves. Cut-off points of AREA% and SWV were determined with receiver operating characteristic curves. Results: Final histopathological results revealed 21 cases of benign and 35 cases of malignant lymph nodes. The mean values of AREA% and SWV in benign and malignant groups were $45.0{\pm}17.9%$ and $2.32{\pm}0.57m/s$, and $61.3{\pm}21.29%$ and $4.36{\pm}1.25$)m/s, respectively. For the parameters of elastography, "AREA%" and SWV demonstrated significant differences between groups (p=0.002). AREA% was positively correlated with SWV with a correlation coefficient of 0.809 (P<0.001). Conclusions: Stiffness of different lymph node diseases in patients may differ. Elastography can evaluate changes sensitively and provide valuable information to doctors. The study proved that the VTIQ elastography technique can play an important role in differential diagnosis of lymph nodes.

Assessing the Potential of Thermal Imaging in Recognition of Breast Cancer

  • Zadeh, Hossein Ghayoumi;Haddadnia, Javad;Ahmadinejad, Nasrin;Baghdadi, Mohammad Reza
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.18
    • /
    • pp.8619-8623
    • /
    • 2016
  • Background: Breast cancer is a common disorder in women, constituting one of the main causes of death all over the world. The purpose of this study was to determine the diagnostic value of the breast tissue diseases by the help of thermography. Materials and Methods: In this paper, we applied non-contact infrared camera, INFREC R500 for evaluating the capabilities of thermography. The study was conducted on 60 patients suspected of breast disease, who were referred to Imam Khomeini Imaging Center. Information obtained from the questionnaires and clinical examinations along with the obtained diagnostic results from ultrasound images, biopsies and thermography, were analyzed. The results indicated that the use of thermography as well as the asymmetry technique is useful in identifying hypoechoic as well as cystic masses. It should be noted that the patient should not suffer from breast discharge. Results: The accuracy of asymmetry technique identification is respectively 91/89% and 92/30%. Also the accuracy of the exact location of identification is on the 61/53% and 75%. The approach also proved effective in identifying heterogeneous lesions, fibroadenomas, and intraductal masses, but not ISO-echoes and calcified masses. Conclusions: According to the results of the investigation, thermography may be useful in the initial screening and supplementation of diagnostic procedures due to its safety (its non-radiation properties), low cost and the good recognition of breast tissue disease.

Reduction of Zygomatic Arch Isolated Fracture Using Ultra Sound and Needle Marking

  • Kim, Jun Sik;Park, Young Ji;Lee, Yoon Jung;Kim, Nam Gyun;Lee, Kyung Suk
    • Archives of Craniofacial Surgery
    • /
    • v.17 no.4
    • /
    • pp.198-201
    • /
    • 2016
  • Background: Zygomatic arch is a bony arch constituting the lateral midface, which consists of 25% of all midface fractures. There are a number of ways to evaluate the extent of zygomatic arch fracture. Some authors have reported successful treatment outcomes using ultrasound (U/S). To add to the previous methods, we have considered ways to accurately display the location of the fracture line while using U/S with 23 gauge needle marking. We introduce our method, which provided satisfactory results for reduction using a portable U/S, and it can evaluate the fracture line simultaneously when reduction of an isolated zygomatic arch fracture is necessary, and needle marking, which can easily point out the fracture line on U/S. Methods: We studied 21 patients with an isolated zygomatic arch fracture who underwent closed reduction using U/S and needle marking between 2013 and 2015. Results: We achieved satisfactory results in all our cases with respect to reduction by using the Dingman elevator after performing a temporal approach incision, while confirming relative positioning between needle marking and zygomatic fracture at the same time, after insertion of a 23 gauge needle in the skin above the zygomatic arch fracture line parallel to it. Conclusion: We treated 21 patients with an isolated zygomatic arch fracture using U/S and the needle marking method, which provided satisfactory results because the extent of reduction of the fracture could be evaluated in real-time during the operation and exposure to radiation was reduced.