• Title/Summary/Keyword: ultrasound radiation

Search Result 145, Processing Time 0.033 seconds

Evaluation of ultrasonic reflection characteristics on an interface surface using Simulated Annealing (Simulated Annealing기법을 이용한 초음파의 계면 반사 특성평가)

  • 은길수;김노유;나환선
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2002.04a
    • /
    • pp.395-400
    • /
    • 2002
  • Epoxy coating and sealing used in nuclear plants for the protection of radiation degrades with aging and hazardous atmosphere. In order to evaluate the degradation of the epoxy, dependence of the acoustic impedance on the change of mechanical properties has been used. Unlike metals, the surface of the epoxy coating on a concrete liner is so wavy that the acoustic impedance is difficult to measure by using the reflectivity of the ultrasound on the interface surface because of the irregular reflection and propagation from the epoxy surface. SA(simulated annealing) algorithm is applied to calculate the acoustic impedance using a reflection wave from the rough epoxy surface. The surface waviness and acoustic impedance are taken into account and determined by SA method to evaluate the state of degradation quantitatively.

  • PDF

Frequency Domain Equivalent Circuit Identification of Ultrasound Transducer (주파수 영역 측정에 의한 초음파 변환기 등가회로 추정)

  • 전병두;임준석;송준일;성굉모
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • autumn
    • /
    • pp.325-328
    • /
    • 2000
  • 초음파 변환기의 정합을 위해서는 초음파 변환기의 등가회로 구성이 중요하다. 전통적인 등가회로의 경우 비교적 안정적인 등가회로를 예측하게 해 주지만 초음파변환기 구성에서 일어나는 초음파 변환기 외의 구성품 즉 Backing Material, Acoustic Window Material, Radiation Impedance 등에 의한 부가적인 효과를 모델링하는 데는 한계가 있다. 따라서 좀 더 일반적인 방법으로 초음파 변환기를 모델링하는 방법이 필요하다. 그런 방법의 하나로 주파수 영역 측정에 의한 초음파변환기 등가회로 추정법을 제안한다. 이 방법은 초음파 변환기 제작 시 많이 쓰는 임피던스 분석의 결과를 그대로 사용할 수 있고 또 그것이 없어도 일반 함수발생기와 오실로스코프만으로 측정할 수 있어서 랜덤함수를 발생시키고 이에 대한 출력을 저장해야 데이터를 얻을 수 있는 시간영역 추정법에 대해서 장점을 갖는다.

  • PDF

Case Analysis of Persistent Vasospasm after Cerebral Artery Aneurysm Rupture by Using Transcranial Color Coded Doppler Ultrasonography (경두개 색조 도플러 초음파검사를 이용한 대뇌동맥 파열 이후 지속적인 혈관 연축 증례 분석)

  • Ji, Myeong-Hoon;Seoung, Youl-Hun
    • Journal of radiological science and technology
    • /
    • v.44 no.1
    • /
    • pp.15-23
    • /
    • 2021
  • In this case analysis, a patient was diagnosed with subarachnoid hemorrhage (SAH) in a 49-year-old female and showed persistent vasospasm after coil emboilzation in an aneurysm. The patient suffered from persistent vasospasm and performed angioplasty a total of 6 times. Transcranial color coded doppler (TCCD) was performed 12 times to monitor vasospasm. As a result, repetitive cerebral blood flow tests were low cost and safely performed without exposure to invasive radiation through the TCCD, and the repeatability and reproducibility of the test were confirmed with the capabilities of a trained professional radiological technologist.

Image Evaluation and Association Analysis of the Cardiovascular Disease of the Degree of Pancreatic Steatosis in Ultrasonography

  • Cho, Jin-Young;Ye, Soo-Young;Ko, Seong-Jin
    • Transactions on Electrical and Electronic Materials
    • /
    • v.17 no.6
    • /
    • pp.375-379
    • /
    • 2016
  • Increasing fat tissue of obese people, increases the rate of cardiovascular disease, diabetes, metabolic syndromes and dyslipidemia. An increase in the focal tissue of pancreas is a known risk factor of these diseases. Although there exists sufficient research on the diagnosis and treatment of pancreatic cancer, studies have been done on fatty pancreas. In this study, based on ultrasound imaging and using a texture characteristic of GLCM, fatty pancreas was divided into three categories: mild, moderate and severe. We compared and analyzed the three groups was by Pancreatic ultrasonography and body characteristics, serological tests, pressure and the degree of arteriosclerosis, against normal control group. The following parameters of control and test groups were measured: WC (waist circumference),BMI (body mass index), TC (total cholesterol), TG (triglyceride), HDL-C (High-density lipoprotein cholesterol) and LDL-C (Low-density lipoprotein cholesterol), SBP (systolic blood pressure), BST (Blood Sugar Test) and aortic PWV (pulse wave velocity). We observed the values correspondingly increasing fat deposition. However, ABI (Ankle Brachial pressure index) stenosis and HDL-C levels decreased with increasing fat deposit (p <0.05); a drop in these parameters are known to be harmful to the human body. The difference in texture characteristics between normal control group and pancreatic fatty group (mild, moderate, and severe) was statistically confirmed. Ultrasound imaging of pancreatic steatosis categorized the disease as mild, moderate and severe based on the characteristic texture. In conclusion, we observed on increase in metabolic syndrome, dyslipidemia, and arteriosclerosis, proportional to the degree of pancreatic fat deposition. The escalation of these diseases was confirmed and was directly related with predictors of cardiovascular diseases.

A Study in the Crimes of the Medical Practice without License - Case of Oriental Medicine's use of Ultrasounds - (무면허의료행위에 대한 형사법적 쟁점 - 한의사의 초음파기기 사용을 중심으로 -)

  • Jang, Jun Hyuk
    • The Korean Society of Law and Medicine
    • /
    • v.15 no.1
    • /
    • pp.35-57
    • /
    • 2014
  • Recently, there has been fierce argument between oriental and western doctors in the medical field. The use of medical devices has particularly come to the fore lately. Appropriate medical devices are required to diagnose and treat patients' conditions or illnesses accurately. At issue recently in medical device sector are diagnostic instruments using radiation, magnetic resonance imaging, ultrasound, IPL(Intense Pulse Light), and instruments used for tonometry. Relating to this issue, Association of Korean Oriental Medicine and The Association of Korean Medicine are sharply opposed. It is predicted that more accusations of this kind will be seen in the future. As oriental medicine contends, ultrasonic imaging itself seems to cause no harm to humans and its use may have an advantage for national health. The use of western diagnostic equipment can expand the diagnostic range of oriental doctors. However, unless new legislation is made, it is against the law for oriental doctors to use this equipment. Both law and medical science require grounds and predictability on the correctness of a decision and all of its consequences. Additionally, oriental medicine's use of ultrasounds and other medical devices should be established by standards and grounds which make same the diagnosis with repetition. Therefore, the scope of oriental medicine can be expanded following a revision of the Oriental Medicine Promotion Act and it is estimated that the state of national health will be greatly improved by the mutual respect of both sides of the health profession.

  • PDF

Convergence Risk Factors for Thyroid Nodules Diagnosed Ultrasound (초음파검사로 진단된 갑상선결절의 융복합 위험요인)

  • Lee, Hye-Nam;Park, Yeon-Hwa
    • Journal of Digital Convergence
    • /
    • v.14 no.1
    • /
    • pp.305-310
    • /
    • 2016
  • Recently as the ultrasonography became generalized, the annual change rate of the incidence of thyroid cancer extraordinarily grew to 24.5% in Korea. Therefore, the aim of this study was performed to identify the risk factors of thyroid cancer apart from conventional risk factors of dietary iodine and ionizing radiation. In this retrospective study, 411 patients underwent fine-needle aspiration biopsy were examined from January 2011 to March 2013. The subjects are divided into two groups which are 260 patients with benign nodule and 151 patients with malignancy nodule. We compared age, hematologic values, body mass index, waist circumference, menopausal status, breast nodules status, uterine myoma status, fatty liver status of targeted group of patients. According to the result, in thyroid cancer group with obesity, the number of case of breast nodules and myoma was higher, and their thyroid stimulating hormone values was higher than the benign nodule group. In order to establish factors influencing thyroid and thyroid cancer, there is a definite need for continuous study.

Ultrasonic Backscattering on Painted Rough Surface at near Rayleigh Angle (레일리각 근처에서 도색된 거친 표면으로부터 후방 산란된 초음파)

  • Kwon, Sung-D.;Kwon, Yong-G.;Yoon, Seok-S.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.1
    • /
    • pp.1-7
    • /
    • 2004
  • The angular dependence (or profile) of backscattered ultrasound was measured for steel specimens with a range of surface roughness, $1{\sim}71{\mu}m$. Backscattering profiles at or near the Rayleigh angle still showed roughness dependence while the assessment of surface roughness via normal profile became impossible due to the paint layer masking the roughness. The peak amplitude directly radiated at the Rayleigh angle was proportional to the surface roughness, while the averaged peak amplitude radiated from the backward propagating Rayleigh wave, produced by reflection at a corner, was inversely proportional. In the painted specimens, the linearity of direct backward radiation with the roughness was observed even at the roughness of less than three hundredths of a wavelength, and the abnormal multiple bark reflection caused by periodic roughness disappeared.

Percutaneous Ultrasound-Guided Fine-Needle Aspiration Cytology and Core-Needle Biopsy for Laryngeal and Hypopharyngeal Masses

  • Dongbin Ahn;Gil Joon Lee;Jin Ho Sohn;Jeong Eun Lee
    • Korean Journal of Radiology
    • /
    • v.22 no.4
    • /
    • pp.596-603
    • /
    • 2021
  • Objective: To evaluate the feasibility and diagnostic performance of ultrasound (US)-guided fine-needle aspiration cytology and core-needle biopsy (US-FNAC/CNB) for the diagnosis of laryngo-hypopharyngeal masses. Materials and Methods: This was a single-center prospective case series. From January 2018 to June 2019, we initially enrolled 40 patients with highly suspicious laryngo-hypopharyngeal masses on laryngoscopic examinations. Of these, 28 patients with the mass involving or abutting the pre-epiglottic, paraglottic, pyriform sinus, and/or subglottic regions were finally included. These patients underwent US examinations with/without subsequent US-FNAC/CNB under local anesthesia for evaluation of the laryngo-hypopharyngeal mass. Results: Of the 28 patients who underwent US examinations, a laryngo-hypopharyngeal mass was identified in 26 patients (92.9%). US-FNAC/CNB was performed successfully in 25 of these patients (96.2%), while the procedure failed to target the mass in 1 patient (3.8%). The performance of US caused minor subclinical hematoma in 2 patients (7.7%), but no major complications occurred. US-FNAC/CNB yielded conclusive results in 24 (96.0%) out of the 25 patients with a successful procedure, including 23 patients with squamous cell carcinoma (SCC) and 1 patient with a benign mass. In one patient with atypical cells in US-FNAC, additional direct laryngoscopic biopsy (DLB) was required to confirm SCC. Among the 26 patients who received US-FNAC/CNB, the time from first visit to pathological diagnosis was 7.8 days. For 24 patients finally diagnosed with SCC, the time from first visit to the initiation of treatment was 25.2 days. The mean costs associated with US-FNAC/CNB was $272 under the Korean National Health Insurance Service System. Conclusion: US-FNAC/CNB for a laryngo-hypopharyngeal mass is technically feasible in selected patients, providing good diagnostic performance. This technique could be used as a first-line diagnostic modality by adopting appropriate indications to avoid general anesthesia and DLB-related complications.

Analysis of the Accuracy about Abdominal Ultrasonography and Clinical Chemical Test with Fatty Liver Patients on the Medical Examination (종합검진 후 지방간 환자의 복부 초음파 검사와 임상화학적 검사결과의 정확성 분석)

  • Kim, Young-Jae;Song, Jong-Nam;Kim, Min-Eui
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.3
    • /
    • pp.183-189
    • /
    • 2012
  • Ultrasonography is one of the fields on the imaging studies within intra-abdominal organs. A blood test is a typical method of clinical chemical examination on the in vivo test of clinical symptoms. Fatty liver is performed simultaneously two kinds of diagnostics methods, intra-abdominal ultrasound and blood tests. At an implementing this, the standard of blood tests value was the TBIL, TC, AST, ALT, ALP, GGT, TG, HDL-C, GLU. In this study analyzing the accuracy of the two kinds of test, ultrasonography and blood test, on patients with fatty liver. From January to March 2012, patients 459 determined fatty liver within 1350, who received health examination simultaneously on the intra-abdominal ultrasonography and blood tests. Same result of ultrasonography and blood test's patients were 459 ie, 60.8%. and different result of those examinations was 280 ie, 39.2%. Consequently diagnostic accuracy was 60.8%. It presumably caused by differences in the diagnostic performance of ultrasound professionals(Radiologist or Radiological Technologist). In order to overcome this, ongoing educational and study will be needed.

Clinical Characteristics of False-Positive Lymph Node on Chest CT or PET-CT Confirmed by Endobronchial Ultrasound-Guided Transbronchial Needle Aspiration in Lung Cancer

  • Lee, Jongmin;Kim, Young Kyoon;Seo, Ye Young;Choi, Eun Kyoung;Lee, Dong Soo;Kim, Yeon Sil;Hong, Sook Hee;Kang, Jin Hyoung;Lee, Kyo Young;Park, Jae Kil;Sung, Sook Whan;Kim, Hyun Bin;Park, Mi Sun;Yim, Hyeon Woo;Kim, Seung Joon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.81 no.4
    • /
    • pp.339-346
    • /
    • 2018
  • Background: Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a standard procedure to evaluate suspicious lymph node involvement of lung cancer because computed tomography (CT) and $^{18}F$-fluorodeoxyglucose positron emission tomography-CT (PET-CT) have limitations in their sensitivity and specificity. There are a number of benign causes of false positive lymph node such as anthracosis or anthracofibrosis, pneumoconiosis, old or active tuberculosis, interstitial lung disease, and other infectious conditions including pneumonia. The purpose of this study was to evaluate possible causes of false positive lymph node detected in chest CT or PET-CT. Methods: Two hundred forty-seven patients who were initially diagnosed with lung cancer between May 2009 and December 2012, and underwent EBUS-TBNA to confirm suspicious lymph node involvement by chest CT or PET-CT were analyzed for the study. Results: Of 247 cases, EBUS-TBNA confirmed malignancy in at least one lymph node in 189. The remaining 58 patients whose EBUS-TBNA results were negative were analyzed. Age ${\geq}65$, squamous cell carcinoma as the histologic type, and pneumoconiosis were related with false-positive lymph node involvement on imaging studies such as chest CT and PET-CT. Conclusion: These findings suggest that lung cancer staging should be done more carefully when a patient has clinically benign lymph node characteristics including older age, squamous cell carcinoma, and benign lung conditions.