• 제목/요약/키워드: ultrasound measurement

검색결과 328건 처리시간 0.031초

체지방량 추정을 위한 초음파피지후계와 Caliper의 비교 (Comparison of Caliper and Ultrasound Measurement for the Estimation of Body Fat)

  • 정진욱
    • Journal of Nutrition and Health
    • /
    • 제28권4호
    • /
    • pp.282-290
    • /
    • 1995
  • Subcutaneous fat thickness of 74 young male was measured at six sites(biceps, triceps, subscapula, suprailiac, abdomen, thigh). The present study compared caliper with ultrasound measurements for the estimation of body fat. Caliper measurements subcutaneous at six sites had higher coefficient variation than did the ultrasound measures. Caliper measurements subcutaneous at six sites had higher ratio (caliper/ultrasound) than did the ultrasound measures. Compared to other body sites, the correlations between caliper and ultrasound measurements were high for the subscapula(r=0.7327), abdomen(r=0.7355) and thigh (r=0.7207) sites. the correlations between caliper and ultrasound measurements were high for the suprailiac(r=0.6616) site by lean group. the correlations between caliper and ultrasound measurements were high for the abdomen(r=0.7636) site by normal group. The correlations between caliper and ultrasound measurements were high for the subscapula (r=0.8959) and abdomen(r=0.8237) sites by obese group. Ultrasound measurement of biceps(r=-0.4459), abdomen9r=-0.4469), thigh(r=-0.4348) had the highest correlation with body density. Caliper measurement of triceps(r=-0.4017), subscapula(r=-0.4454), abdomen(r=-0.4293) had the highest correlation with body density. Ultasound measurements subcutaneous fat at lean group, obese group had higher coefficients of correlation with body density than did the caliper measurement. Caliper measurements subcutaneous fat at normal group had higher coefficients of correlation with body density than did the ultrasound measures. Ultrasound showed to be superior to the caliper technique in measuring subcutaneous fat of obese persons.

  • PDF

Analysis of environment effects on the carcass traits Hanwoo cows using ultrasonic measurement

  • Choi, Tae-Jeong;Lee, Sang-Jae;Park, Jong-Eun;Lim, Dajeong;Cho, Yong-Min;Park, Byoungho
    • 농업과학연구
    • /
    • 제45권1호
    • /
    • pp.66-73
    • /
    • 2018
  • Hanwoo is an important livestock resource in Korea. Its genetic improvements of economic traits have mainly focused on the steers in the past. However, there is a great necessity to extend the breed improvement programs to the cows as well. Therefore, the objective of this study was to investigate the effects of various environmental factors (person taking the measurement, region, year of measurement, month of measurement, image interpreter, birth-year and birth-year) on ultrasound measured carcass traits. A total of 27,215 ultrasound measurements of carcass traits were recorded between 2004 and 2012 for 22,620 cows born from 1997 to 2011. The ultrasound measures included backfat thickness (BFT), eye muscle area (EMA), and marbling score (MAR). The mean values for the BFT, EMA and MAR were 4.46 mm, $56.24cm^2$, and 4.12 point, respectively. Seven environmental factors, person taking the measurement, region, year of measurement, month of measurement, image interpreter, birth-year and birth-month, were tested to determine if they had a significant effect on the studied traits using the GLM procedure in SAS. All factors were found to significantly affect all the ultrasound carcass traits in this study. Unlike in previous studies, among the environmental effects, the significant effect of the image interpreter on the ultrasound carcass traits was shown for the first time in this study. These results indicate that future genetic evaluations of ultrasound carcass traits of Hanwoo cows should include all of the above environmental factors as well as the effect from people taking the measurements.

인체 삽입형 인공 의료 기구물 기계적 결함 모니터링을 위한 초음파 시스템 및 계측 기술 연구 (Research on Ultrasound System and Measurement Technology for Mechanical Defect Monitoring of Human-inserted Artificial Medical Devices)

  • 윤상연;이문환;황재윤
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2021년도 춘계학술대회
    • /
    • pp.470-473
    • /
    • 2021
  • 본 연구에서는 인공 관절치환술 시 삽입되는 라이너의 잔존 두께 측정과 비구컵과의 결합 상태를 판별 할 수 있는 생체 삽입형 보철물 두께 측정 시스템 개발을 위한 생체 삽입형 초음파 변환자의 개발, 잔존 두께측정 알고리즘 및 최적화된 초음파 운용 방법에 대한 연구를 진행했다. 세부적으로, 비슷한 민감도와 대역폭을 갖는 8MHz 와 20MHz의 중심주파수를 갖는 초음파 변환자를 제작하여 상용 폴리에틸렌 재질의 인공 고관절 라이너의 다양한 두께를 측정함으로써 신호대잡음비와 축방향 해상도 비교 분석을 진행하여 체내 초음파 운용 방식 최적화 연구를 진행하였다.

  • PDF

초음파 센싱 방식의 spirometer에 대한 sensitivity 향상 (Sensitivity Elevation about Spirometer Using Ultrasound Sensing Method)

  • 한승헌;김영길
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2004년도 춘계종합학술대회
    • /
    • pp.269-272
    • /
    • 2004
  • 초음파 센서를 이용한 호흡측정방식은 관성 및 압력의 오차의 영향을 거의 받지 않고, 반영구적으로 사용이 가능한 호흡기기이다. 초음파의 특성을 이용한 것으로 송수신시 초음파의 매질인 공기의 흐름에 의한 반송형식인 초음파의 전달속도 차이를 이용하여 호흡량 및 흐름을 detecting하는 기술이다. 본 논문에서는 환자를 중심으로 측정이 이루어져야 하기 때문에 센서의 송수신시 일어나는 신호의 sensitivity를 향상시켜서 약한 호흡에도 dectection이 가능하도록 하였다.

  • PDF

집속초음파 자극기의 성능평가를 위한 팬텀 내부온도 측정 (Measurement of Internal Temperature Distribution for the Evaluation of Focused Ultrasound (FUS) Stimulation Devices)

  • 도일;조주형;김성목;백경민;김용태;박승민
    • 대한의용생체공학회:의공학회지
    • /
    • 제43권3호
    • /
    • pp.147-152
    • /
    • 2022
  • This research is to measure real-time temperature distribution inside a tissue-mimicking phantom for the safety and effectiveness evaluations of focused ultrasound (FUS) device capable of linear scanning stimulation. Since the focusing area of the FUS stimulation device is smaller than diameter of conventional thermal probe and keeps moving, it is impossible to monitor temperature distribution inside the phantom. By using the phantom with a thin film temperature sensor array inserted, real-time temperature change caused by the FUS device was measured. The translation of the measured temperature peak was also tracked successfully. The present phantom had been experimentally proven to be applicable to validate the performance and safety of the therapeutic ultrasound devices.

Infrared Thermography Characterization of Defects in Seamless Pipes Using an Infrared Reflector

  • Park, Hee-Sang;Choi, Man-Yong;Park, Jeong-Hak;Lee, Jea-Jung;Kim, Won-Tae;Lee, Bo-Young
    • 비파괴검사학회지
    • /
    • 제32권3호
    • /
    • pp.284-290
    • /
    • 2012
  • Infrared thermography uses infrared energy radiated from any objects above absolute zero temperature, and the range of its application has been constantly broadened. As one of the active test techniques detecting radiant energy generated when energy is applied to an object, ultrasound infrared thermography is a method of detecting defects through hot spots occurring at a defect area when 15~100 kHz of ultrasound is excited to an object. This technique is effective in detecting a wide range affected by ultrasound and vibration in real time. Especially, it is really effective when a defect area is minute. Therefore, this study conducted thermography through lock-in signal processing when an actual defect exists inside the austenite STS304 seamless pipe, which simulates thermal fatigue cracks in a nuclear power plant pipe. With ultrasound excited, this study could detect defects on the rear of a pipe by using an aluminium reflector. Besides, by regulating the angle of the aluminium reflector, this study could detect both front and rear defects as a single infrared thermography image.

Sensitivity Enhancement of Spirometer Employing Ultrasonic Method

  • Han, Seung-Heon;Kim, Young-Kil
    • 대한의용생체공학회:의공학회지
    • /
    • 제26권6호
    • /
    • pp.351-356
    • /
    • 2005
  • Respiration measurement method using an ultrasound sensor is influenced very little by an error of inertia and pressure. This device measures the amount and flow of respiration using a delivery speed difference of the ultrasound waves that are a return format by the pneumatic stream that is a flogging of ultrasound waves during transmission and receipt as having used a characteristic of ultrasound waves. This paper examines improving the sensor's sensitivity during transmission and receipt of the signal. Because the measurement must be performed on patients, clinicians need to be sure that it is accurately measuring even very weak breathing.

초음파와 카메라의 초점화를 이용한 거리계측 시스템 설계 (Design of Range Measurement Systems Using Ultrasound and Camera Focusing)

  • 문창수;도용태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.595-597
    • /
    • 2004
  • In this paper range measurement systems using ultrasonic and visual sensors are designed. By varying the focus of a camera, the range to a target pattern is computed. Pour different methods are tested for the focusing-based range measurement. The best result is obtained when counting edge pixels found by Laplacian operator. Higher accuracy can be obtained by fusing the measurement of camera focusing with that of ultrasonic sensor. The system designed is experimented within the range of 300-450mm.

  • PDF

초음파 센싱 방식의 spirometer에 대한 sensitivity 향상 연구 (A Study on the Sensitivity Elevation about Spirometer Using Ultrasound Sensing Method)

  • 한승헌;김영길
    • 한국정보통신학회논문지
    • /
    • 제9권1호
    • /
    • pp.204-209
    • /
    • 2005
  • 초음파 센서를 이용한 호흡측정방식은 관성 및 압력의 오차의 영향을 거의 받지 않고, 반영구적으로 사용이 가능한 호흡기기이다. 초음파의 특성을 이용한 것으로 송수신시 초음파의 매질인 공기의 흐름에 의한 반송형식인 초음파의 전달속도 차이를 이용하여 호흡량 및 흐름을 detecting하는 기술이다. 본 논문에서는 환자를 중심으로 측정이 이루어져야 하기 때문에 센서의 송수신시 일어나는 신호의 sensitivity를 향상시켜서 약한 호흡에도 dectection이 가능하도록 시스템의 성능을 향상시켰다.

Estimation of Genetic Correlations and Selection Responses for Carcass Traits between Ultrasound and Real Carcass Measurements in Hanwoo Cows

  • Son, Jihyun;Lee, Deukhwan
    • Journal of Animal Science and Technology
    • /
    • 제55권6호
    • /
    • pp.501-508
    • /
    • 2013
  • This study was conducted to determine genetic correlations among carcass traits measured by ultrasound and real carcass measurements and to estimate indirect selection responses for real carcass traits based on ultrasound measurements in Hanwoo cows. To accomplish this, 22,080 ultrasound measurement records from 17,926 cows collected from 2001 to 2012 and 11,907 carcass records obtained from fattened cattle from 2008 to 2012 were used. Genetic parameters were estimated based on eye muscle area (EMA), backfat thickness (BF) and marbling score (MS) measured by ultrasound-scanning of live cows and using the official technique on chilled bovine half-carcasses after slaughtering. Heritability and genetic correlation for carcass traits were estimated using a mixed model equation that consisted of environmental effects as fixed parameters and additive genetic effects and residual effects as random parameters, assuming that traits were different between ultrasound and carcass measurements. This statistical method was applied to the average information restricted maximum likelihood method. The heritability of EMA, BF and MS measured by ultrasound were 0.33, 0.61 and 0.46, respectively, while the heritability estimates of the corresponding traits based on carcass measurements were 0.29, 0.40 and 0.38, respectively and the genetic correlation between ultrasound and carcass traits for EMA, BF and MS were 0.41, 0.78 and 0.67, respectively. The genetic correlation between ultrasound and carcass traits was highly positive. Additionally, the selection response for marbling score was estimated to be 0.42 per generation if the cows were selected based on the ultrasound scan marbling score with an assumed selection intensity of 0.8. Overall, these results indicate that the ultrasound scan technique would be applicable to judging cow selection for genetically improved meat quality.