• Title/Summary/Keyword: ultrasound

Search Result 3,255, Processing Time 0.026 seconds

Correlation between Results of Preoperative Impingement Test and Clinical Outcomes after Arthroscopic Rotator Cuff Repair

  • Park, Sung Bae;Seo, Joong Bae;Ryu, Jee Won;Shin, Yong Eun
    • Clinics in Shoulder and Elbow
    • /
    • v.20 no.3
    • /
    • pp.126-132
    • /
    • 2017
  • Background: The aim of the present study was to determine the correlation between the amount of pain reduction after local anesthetic injection into the subacromial space preoperatively and clinical outcome after arthroscopic rotator cuff repair. Methods: A total of 127 patients who underwent arthroscopic rotator cuff repair and followed up at least 1 year were analyzed retrospectively. Preoperatively, a visual analogue scale (VAS) for pain was measured in all patients before and after the ultrasound guided impingement test. The participants were divied into four groups according to pain reduntion ater impingement test (Group A: >75%, Group B: 50%-75%, Group C: 25%-50%, Group D: <25%). VAS for pain, shoulder range of motion, shoulder isometric strength, ASES score were evaluated preoperatively and at 3, 6, 9, and 12 months postoperatively. Results: After surgery, the amount of pain reduction shows significantly at 3, 6 months in Groups A, B as compared to Groups C, D (p<0.05). Among the range of motion of shoulder joint, forward flexion was significantly improved in Group A at 3 months (p<0.05). The ASES score significantly improved at 3, 6 months in Groups A, B as compared to Group C, D (p<0.05). Conclusions: Preoperative degree of pain reduction after impingement test correlates with the improvement of pain after arthroscopic rotator cuff repair, especially in the early phase. Therefore, the impingement test could be effectively used.

Computer Simulation for X-ray Breast Elastography (X선 유방 탄성 영상을 위한 컴퓨터 모의 실험)

  • Kim, Hyo-Geun;Aowlad Hossain, A.B.M.;Lee, Soo-Yeol;Cho, Min-Hyoung
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.2
    • /
    • pp.158-164
    • /
    • 2011
  • Breast cancer is the most frequently appearing cancer in women, these days. To reduce mortality of breast cancer, periodic check-up is strongly recommended. X-ray mammography is one of powerful diagnostic imaging systems to detect 50~100 um micro-calcification which is the early sign of breast cancer. Although x-ray mammography has very high spatial resolution, it is not easy yet to distinguish cancerous tissue from normal tissues in mammograms and new tissue characterizing methods are required. Recently ultrasound elastography technique has been developed, which uses the phenomenon that cancerous tissue is harder than normal tissues. However its spatial resolution is not enough to detect breast cancer. In order to develop a new elastography system with high resolution we are developing x-ray elasticity imaging technique. It uses the small differences of tissue positions with and without external breast compression and requires an algorithm to detect tissue displacement. In this paper, computer simulation is done for preliminary study of x-ray elasticity imaging. First, 3D x-ray breast phantom for modeling woman's breast is created and its elastic model for FEM (finite element method) is generated. After then, FEM experiment is performed under the compression of the breast phantom. Using the obtained displacement data, 3D x-ray phantom is deformed and the final mammogram under the compression is generated. The simulation result shows the feasibility of x-ray elasticity imaging. We think that this preliminary study is helpful for developing and verifying a new algorithm of x-ray elasticity imaging.

The Evaluation about the Information Fidelity in the External Image Information Input - Using DICOM Validation Tool - (외부영상정보 입력 시 DICOM정보 충실성에 대한 평가 - DICOM Validation Tool 이용 -)

  • Lee, Song-Woo;Lee, Ho-Yeon;Do, Ji-Hoon;Jang, Hye-Won
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.1
    • /
    • pp.33-38
    • /
    • 2011
  • Now a days, there's many change over for PACS among the most of hospital and it standard for DICOM 3.0. These kind of using of DICOM 3.0 improves increasing of medical imaging exchange and service for patient. However, there's some problems of compatibility caused during carry out CD and DVD from hospital. For this reason, this thesis analyzed patients image targeting those storages requested to hospitals in Seoul by using Validation Toolkit which is recommended from KFDA. The analyze type is like this. Make 100 data, total 500, each of MRI CT Plain x-ray Ultrasound PET-CT images and analyzed type of error occurred and loyalty of information. If express percentage of error occurred statistically, we can get a result as follows MRI 5%, Plain x-ray 11%, CT 18%, US 25%, PET-CT 30%. The reson why percentage of error occurred in PET-CT is because of imperfective support and we could notice that we weren't devoted to information. Even though, PET-CT showed highest percentage of error occurred, currently DICOM data improved a lot compare to past. Moreover, it should be devoted to rule of IHE TOOL or DICOM. In conclusion, we can help radiographer to analyze information of image by providing clues for solving primary problem and further more, each of PACS company or equipment company can enhance fidelity for following standard of image information through realizing the actual problem during transfer of image information.

  • PDF

Compare correlation differnces in blood in blood flow velocity parameters and blood flow velocity the radial artery and a piece of paper as a maker (요골동맥과 첨지를 이용하여 혈류속도 파라미터와 혈류속도 사이의 상관관계 비교)

  • Heo, Sun-Oh;Jeong, Jin-Hyeong;Lee, Sang-Sik
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.8 no.2
    • /
    • pp.187-193
    • /
    • 2015
  • In this study, regressive models were employed to predict the blood velocity by using independent variables which measured by 3 sensors, such as electrocardiogram (ECG), photo-plethysmogram (PPG), pulse diagnosis sensor, without ultrasound device at high cost. In experiment, the high predictable model was induced to estimate the blood velocity correctly by comparing correlation values and significance probabilities between independent variables and blood velocities. Results showed that the model induced by two or three independent variables had a higher predictability than those by a single independent variable.

Changes in the Biomechanical Properties of Ankle Plantarflexors Following 8-week Resistance Training with or without Whole-Body Vibration in Older Women (8주간의 체중을 이용한 저항운동 시 전신진동 유·무에 따른 노인 여성하지의 발바닥쪽굽힘근의 생체역학적 특성 변화)

  • Han, Bo-Ram;Lee, Dae-Yeon;Jeong, Si-Woo;Lee, Hae-Dong
    • Korean Journal of Applied Biomechanics
    • /
    • v.24 no.4
    • /
    • pp.399-415
    • /
    • 2014
  • The aim of this study was to investigate the effect of resistance training with and without whole-body vibration(WBV) on the biomechanical properties of the plantarflexor in the elderly women (>60 yrs., n=35). Thirty-five volunteers were randomly assigned to a resistance training with WBV group (RVT, n=14), a resistance training without WBV (RT, n=11), and a non-training control group (CON, n=10). The RVT and the RT groups participated in the training sessions three times a week for 8 weeks, followed by a 4-week detraining period. The CON group was instructed to refrain from any type of resistance training. To assess strength and activation of the plantarflexor muscles, maximum isometric ankle plantarflexion torque and muscle activation of the triceps surae muscles were measured using dynamometry, twitch interpolation technique and electromyography at four different ankle joint angles. Also, the lower extremity function was assessed by vertical jumping. The measurements were performed prior to, 2 and 8 weeks after the training and after a 4-week detraining period. Following the 8-week training sessions, an increase in the isometric plantarflexion strength was found to be greater for the RVT compared with the RT group (p<.05). Muscle inhibition was significantly decreased after training than before training only for the RVT (p<.05). Following the detraining period, a decrease in isometric plantarflexors strength and a increases in muscle inhibition were significantly less in the RVT compared with the RT group. In conclusion, the exercise with WBV is a feasible training modality for the elderly and seems to have a boosting effect when used with conventional resistance training.

Influence of Muscle Architecture on Force Enhancement Following Muscle Lengthening (근육 구조특성과 선행 신장성 수축에 의한 항정상태 등척성 근력 증대와의 연관성에 대한 연구)

  • Lee, Hae-Dong;Lee, Jung-Hyun
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.3
    • /
    • pp.61-68
    • /
    • 2007
  • When an active muscle is stretched, its steady-state isometric force following stretch is greater than that of a purely isometric contraction as the corresponding muscle length, referred to as force enhancement (FE). The purpose of this study was to investigate possible effects of muscle architecture on the FE. While subject performed maximal isometric dorsiflexion (REF) and isometric-stretch-isometric dorsiflexion (ECC) contractions, ankle joint angle and dorsiflexion torque using a dynamometer and electromyography of the tibialis anterior and the medical gastrocnemius muscles were measure. Simultaneously, real-time ultrasound images of the tibialis anterior were acquired. Regardless of the speed of stretch of the ECC contractions. the torques produced during the isometric phase following stretch ($37.3{\pm}1.5\;Nm$ ($10{\pm}3%$ FE) and $38.3{\pm}1.5$ ($12{\pm}3%$ FE) for the ECC contractions with $15^{\circ}$/s and $45^{\circ}$/s stretch speeds, respectively) were greater than those of the REF contractions ($34.5{\pm}2.5\;Nm$). Moreover, the amount of FE was found to be stretch speed dependent. Angles of pennation ($\alpha$) during the isometric phase following stretch were the same for the REF ($15{\pm}1^{\circ}$) and the ECC ($14{\pm}1^{\circ}$(LS), $15{\pm}1^{\circ}$(LF)). During the same phase, muscle thicknesses were the same ($14.9{\pm}0.6$, and $14.9{\pm}0.5\;mm$ for the REF and the ECC contractions, respectively). For a large limb muscle, the tibialis anterior muscle, a similar amount of force enhancement was observed as did for other human skeletal muscles. Architectural variables, pennation angle and thickness, were not systematically different between the REF and ECC contractions when FE occurred. Therefore, the results of this study suggest that muscle architecture may have little influence on the production of FE.

Ultrasonic dissection versus electrocautery for immediate prosthetic breast reconstruction

  • Lee, Dongeun;Jung, Bok Ki;Roh, Tai Suk;Kim, Young Seok
    • Archives of Plastic Surgery
    • /
    • v.47 no.1
    • /
    • pp.20-25
    • /
    • 2020
  • Background Ultrasonic dissection devices cause less thermal damage to the surrounding tissue than monopolar electrosurgical devices. We compared the effects of using an ultrasonic dissection device or an electrocautery device during prosthetic breast reconstruction on seroma development and short-term postoperative complications. Methods We retrospectively reviewed the medical records of patients who underwent implant-based reconstruction following mastectomy between March 2017 and September 2018. Mastectomy was performed by general surgeons and reconstruction by plastic surgeons. From March 2017 to January 2018, a monopolar electrosurgical device was used, and an ultrasonic dissection device was used thereafter. The other surgical methods were the same in both groups. Results The incidence of seroma was lower in the ultrasonic dissection device group than in the electrocautery group (11 [17.2%] vs. 18 [31.0%]; P=0.090). The duration of surgery, total drainage volume, duration of drainage, overall complication rate, surgical site infection rate, and flap necrosis rate were comparable between the groups. Multivariate analysis revealed that the risk of seroma development was significantly lower in the ultrasonic dissection device group than in the electrocautery group (odds ratio for electrocautery, 3.252; 95% confidence interval, 1.242-8.516; P=0.016). Conclusions The findings of this study suggest that the incidence of seroma can be reduced slightly by using an ultrasonic dissection device for prosthesis-based breast reconstruction. However, further randomized controlled studies are required to verify our results and to assess the cost-effectiveness of this technique.

Correlation between MVIC and Muscle Architecture in the Extensor Carpi Radialis Longus Muscle during Maximum Voluntary Isometric Contraction (최대 수의적 등척성 수축을 하는 동안 장요측 수근 신근에서 최대 수의적 등척성 수축력과 근 구조와의 상관관계)

  • Lim, Young-Eun;Kim, In-Geol;Kim, Tae-Youl;Yoon, Se-Won;Seo, Sam-Ki;Lee, Jeong-Woo
    • The Journal of Korean Physical Therapy
    • /
    • v.19 no.6
    • /
    • pp.23-30
    • /
    • 2007
  • Purpose: This study examined the correlation between the maximum voluntary isometric contraction (MVIC) and the muscle architecture in the extensor carpi radialis longus muscle during MVIC. Methods: The muscle area, volume were measured using a ultrasound imaging system to obtain the muscle architecture during the MVIC. For the mechanical muscle strength measurements, the MVIC was obtained using a dynamometer. Results: There was a significant correlation between the MVIC and the muscle area (r=0.498, p<0.01) and muscle volume (r=0.602, p<0.001). There was a significant correlation between the MVIC and density (r=-0.429, p<0.05). The area showed significant correlations with the muscle volume (r=0.699, p<0.001) and density (r=-0.429, p<0.05). In addition, there was a correlation between the volume and muscle density (r=0.555, p<0.01). Conclusion: There is close relationship between the MVIC and the muscle architecture in the extensor carpi radialis longus muscle during the MVIC.

  • PDF

The Effect of Exercise Using Grasping on Shoulder Muscle Activity and Muscle Thickness of Patients with Rotator Cuff Repair

  • Choi, Eun-Young;Choi, Hyun
    • The Journal of Korean Physical Therapy
    • /
    • v.28 no.1
    • /
    • pp.52-58
    • /
    • 2016
  • Purpose: This study intended to mediate shoulder exercise using grasping and investigate examine how its effects on affects activities of the shoulder surrounding muscles of the shoulder and thickness of shoulder muscle to suggest effective exercise for patients with rotator cuff repair to return to daily life. Methods: This study has been done targeteding male patients more than 6 weeks after having En-masse Suture Bridge Technique as rotator cuff repair of the right shoulder, aged 40 to 55 in a medical institution located in Jeollanam-do. Experimental group I (n=15) was selected for a conducting common exercise therapy program and Experimental group II (n=15) was selected for an conducting exercise therapy program using grasping. %RVC was measured by surface electromyography and muscle thickness was measured by ultrasound before mediation to for analysisze of before and after results within group and between groups. Results: In comparison of change of %RVC, Tthere were meaningful differences in only posterior deltoid and infraspinatus in comparing a change of %RVC within experimental group I (p<0.001),. and Tthere were meaningful differences in both supraspinatus and infraspinatus in muscle thickness within experimental group I (p<0.001). In comparison of change of %RVC, Tthere were meaningful differences in anterior deltoid, posterior deltoid and infraspinatus in comparing a change of %RVC within experimental group II (p<0.05)(p<0.01) (p<0.001), and there were meaningful differences in both supraspinatus and infraspinatus in muscle thickness within experimental group II (p<0.001). In comparison of change of %RVC between groups, Tthere was a meaningful difference in only posterior deltoid in comparing a change of %RVC between groups (p<0.001). Conclusion: We found that exercise therapy using grasping has a positive effect on shoulder stability muscles such as supraspinatus muscle and infraspinatus muscle and activity of deltoid muscle.

A Case of Canine Ectopic Parasitism of Heartworm in the Systemic Circulation (개에서 발생한 전신 순환계의 심장사상충 이소기생 증례)

  • Jang, Hyo-Mi;Lee, Hee-Chun;Jung, Dong-In
    • Journal of Veterinary Clinics
    • /
    • v.32 no.4
    • /
    • pp.347-351
    • /
    • 2015
  • A 3-year-old intact female Dachshund was referred due to paraplegia and cool extremities. History taking, physical examination, neurological examination, and blood profiling studies were evaluated to determine the diagnosis. Based on abdominal ultrasound and echocardiograph, features suggestive of adult heartworm were detected in aberrant places. The result of enzyme-linked immunosorbent assay (ELISA) testing with a commercial heartworm antigen kit was positive. The dog fell into a comatose state, and the client requested the dog be euthanized. On post-mortem examination, the patient was diagnosed with ectopic parasitism of heartworm in the left side of heart, aorta, aorta abdominalis, and iliac arteries, a circumstance that induced systemic thromboembolism. This case report describes the clinical, diagnostic imaging, and necropsy findings of canine ectopic parasitism of heartworm.