• Title/Summary/Keyword: ultrasound

Search Result 3,255, Processing Time 0.026 seconds

Effect of Deep Breathing Exercise and Ankle Exercise on Blood Flow Velocity in the Femoral Vein (심호흡 운동과 발목관절 운동이 대퇴정맥의 혈류속도에 미치는 영향)

  • Jung, Do-Young;Kim, Young;Kwon, Oh-Yun
    • Physical Therapy Korea
    • /
    • v.9 no.2
    • /
    • pp.107-113
    • /
    • 2002
  • This study was conducted to determine the effects of deep breathing exercise and ankle exercise on blood flow velocity in the femoral vein. Sixteen healthy male students were recruited from Yonsei University, at Wonju. The blood flow velocities in the femoral vein were measured under three different conditions: resting, deep breathing, and ankle exercise. All subjects were given a 5-minute relaxing time in supine position prior to the study. Using a doppler ultrasound with a 8 MHz probe, the peak blood flow velocities were collected in a twenty-second-period at each condition. The subjects took a rest in between trials for the blood flow to return to its resting levels. The result showed a significant difference in peak blood flow velocities under those three conditions (p<.001). The peak blood flow velocity was highest in ankle exercise condition. The peak blood velocity was significantly higher in deep breathing condition compared with the resting condition. As a result, it is revealed that not only the muscular contractions but also the deep breathing exercises induced facilitating effects of venous return. Either of the exercise methods can be recommended to prevent blood stasis in patients with risk of deep vein thrombosis after cardiac or lower extremity surgery.

  • PDF

The Study of Voice and Data Transmission System using Underwater Ultrasound (수중초음파를 이용한 음성 및 데이터전송 시스템에 관한 연구)

  • Cho, Hyeok;Lee, Han;Kim, Young-Kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2002.05a
    • /
    • pp.163-166
    • /
    • 2002
  • The underwater acoustic communication has been widely applied to various objects such as ocean exploration-development and military affairs. And recently for embodiment of the communication system that is installed in a submarine and underwater work system, many studies have been progressing. This scope of the main studies in the meantime. It made it possible for a diver and a scuba diver who arc difficult to notice the situation of the outside because of staying in the water to hear a sound through a small speaker by using a ultra sound transducer that a central frequency is 32KHz after modulation of a voice to give the information of the outside. Also in case of happening an emergency to a diver in the water, it made him/her ask for help to a person in the outside by pressing a key and send a letter data to a person in the outside by using a keyboard. Through this system, it is possible to send a voice or data between the underwater and the outside and it is available to a diver or skin scuba diver.

  • PDF

A Study on the Relationship Between State Anxiety and Maternal Fetal Attachment of Unmarried Mothers in a Welfare Center (보호시설 미혼모의 태아애착행위와 상태불안에 관한 연구)

  • Hwang, Ran-Hee
    • Women's Health Nursing
    • /
    • v.11 no.3
    • /
    • pp.218-224
    • /
    • 2005
  • Purpose: The Purpose of this study was to investigate the relationship between state anxiety and maternal fetal attachment of unmarried mothers in a welfare center. Methods: The subjects were 25 unmarried mothers in a welfare center. The data was collected through personal interviews using a questionnaire. The instruments used for this study were the modified Spielberger's state anxiety inventory and Cranley's Maternal-Fetal Attachment Scale. Data was analyzed descriptive statistics, mean, standard deviation, t-test and the pearson correlation coefficient with the SPSS computer program. Results: The age of the subjects ranged from 15 to 25, and their average age was 20.0. The mean score of state anxiety was 58.2. There was significant difference in the degree of maternal state anxiety between the group whose pregnancy was known by their family and the group whose pregnancy was hidden. The group whose pregnancy was known showed a low state anxiety score. There was a significant difference in the degree of maternal state anxiety by the gestational period. The group who were in the second and third gestational trimester showed lower state anxiety score than in the first trimester. The mean score of maternal-fetal attachment(MFA) was 64.9. There were significant differences in the degree of maternal fetal attachment, by an ultrasound scan experience. The most frequently practiced attachment item was "I think the fetus is able to feel(mean 3.8)". Unmarried mothers degree of state anxiety showed a negative correlation with the degree of maternal fetal attachment(r=-.25), but there was no significant difference between the two variables. Conclusions: The unmarried mothers made an effort in striving to reduce their high state anxiety and to enhance maternal fetal attachment. They also realize how to take care of their state anxiety.

  • PDF

Pregnancy Rate by Intrauterine Insemination (IUI) or Timed-Intercourse In Stimulated Cycles with Clomiphene Citrate and Gonadotropins (Clomiphene Citrate와 성선자극호르몬을 병합한 배란유도주기에서 성교와 인공수정에 의한 임신율의 비교)

  • Hong, Jeong-Eui;Lee, Ji-Sam
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.26 no.1
    • /
    • pp.31-41
    • /
    • 1999
  • To evaluate the effectiveness of intrauterine insemination (IUI) in the treatment of infertility, timed-intercourse and intrauterine insemination by husband in stimulated cycles with clomiphene citrate and gonadotropins were compared in a total of 105 cycles. Patients received 100mg of clomiphene citrate daily for 5 days starting on day 3 of the menstrual cycle followed by hMG or FSH. Doses of exogenous gonadotropins were adjusted by the follicular development and concentrations of serum estradiol $(E_2)$. More than 3 follicles reaching >16 mm were present in the ovary, 5,000 IU of hCG was administered intramusculary. Patients received a maximum of three intercourse or IUI cycles for the treatment. Severe male (<$10{\times}10^6$ motile sperm) or age factor (>39 y) patients were excluded in this study. Pregnancy was classified as clinical if a gestational sac or fetal cardiac activity was seen on ultrasound. The overall clinical pregnancy rates were 17.1% per cycle (18/105) and 21.2% per patient (18/85). The pregnancy rates (per cycle) were 17.5% (11/63) in intercourse and 16.7% (7/42) in IUI groups, respectively. IUI had no significant improvement in pregnancy rate compared with timed-intercourse. The multiple pregnancy rates were 11.1% (1 twin and 1 triplet). No patient developed ovarian hyperstimulation. Abortion rate was 28.6% (2/7) in IUI group only. The delivery and ongoing pregnancy rates were 15.2% per cycle (16/105) and 18.8% per patient (16/85). There were no differences in age, duration of infertility, follicle size and level of estradiol $(E_2)$ on the day of hCG injection in pregnant and non-pregnant groups. However, total doses of gonadotropins were higher in pregnant group than in non-pregnant group (p<0.01). Pregnancy rate was not affected by ovulatory status at the time of insemination. These results indicate that well timed-intercourse in stimulated cycles is as effective as IUI for infertile couples.

  • PDF

Assessment of follicular maturation by plasma estradiol levels and ultrasound in the normal and clomiphene-stimulated menstrual cycles (정상월경주기및 클로미펜을 이용한 배란유도 월경주기에서의 난포성장에 관한 연구)

  • Chang, Y.S.;Lee, J.Y.;Moon, S.Y.;Kim, J.K.;Lim, Y.T.;Han, K.S.
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.13 no.1
    • /
    • pp.67-75
    • /
    • 1986
  • Follicle monitoring in the normal and clomiphene·stimulated cycles were analyzed in the Seoul IVF and ET (In vitro fertilization and embryo transfer) program. Ovarian follicular diameters were measured by the real·time sector scanner and plasma estradiol levels were assayed by radioimmunoassay methods during periovulatory period. The maximum follicular sizes of the clomiphene-stimulated and normal cycles were 21.1+-3.4mm and 19.2+-0.8mm, respectively. The peak levels of plasma estradiol in the clomiphene-stimulated and normal cycles were 10538+-553.6ng/ml and 298.3+-39.6pg/ml, respectively. Daily growth rate of the follicular diameters of the clomiphene-stimulated and normal cycles were 2.1mm and 1.9mm, respectively. Mean follicular number of the clomiphene-simulated and normal cycles were 2.28+-1.12 and 1.12+-0.21, respectively. There was a good statistical correlation between the mean follicular diameters and the plasma estradiol levels in the normal ovulatory and c1omiphene-stimulated ovulatory menstrual cycles (p<0.05). Our data revealad that the mean follicular diameter and the plasma estradiol level prior to HCG administration in IVF and program should reach at the level of 17.8+-3.0mm and 949.4+-487.1 pg/ml, respectively.

  • PDF

Sequential Clomiphene Citrate and FSH compared to Clomiphene Citrate and hMG on Pregnancy Rate in Intrauterine Insemination Cycles (Clomiphene Citrate와 FSH 또는 Clomiphene Citrate와 hMG의 연속병합에 의한 배란유도주기에서 인공수정 후 임신율의 비교)

  • Jung, Goo-Sung;Hong, Ki-Eon;You, Seung-Hwan;Lee, Hyeon-Sook;Lee, Jong-In;Hur, Young-Mun;Jeon, Eun-Suk;Yoon, Jeong-Im;Hong, Jeong-Eui;Lee, Ji-Sam
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.26 no.3
    • /
    • pp.433-440
    • /
    • 1999
  • Objective: To evaluate the effectiveness of CC+FSH or CC+hMG in intrauterine insemination (IUI) cycles for the treatment of infertility. Method: Patients received daily 100 mg of clomiphene citrate (CC) for 5 days followed by hMG or FSH. A single IUI was performed at 36 h after hCG. Clinical pregnancy was classified if a gestational sac or fetal cardiac activity was seen on ultrasound. Results: The overall clinical pregnancy rate was 19.1% per cycle (17/89) and 21.5% per patient (17/79). More clinical pregnancies were recorded in CC+FSH (23.1%, 6/26) than CC+ hMG cycles (17.5%, 11/63), but this difference was not statistically significant. No differences were found in age, duration of infertility, follicle size, levels of estradiol ($E_2$) on the day of hCG injection and total motile sperm counts between pregnant and non-pregnant groups. However, more ampules of gonadotropins were used in pregnant group than non-pregnant group (p<0.05). Conclusion: Combination of CC and hMG may economically be more effective to induce ovulation for IUI compared to CC and FSH.

  • PDF

Design of a Cross-obstacle Neural Network Controller using Running Error Calibration (주행 오차 보정을 통한 장애물 극복 신경망 제어기 설계)

  • Lim, Shin-Teak;Yoo, Sung-Goo;Kim, Tae-Yeong;Kim, Yeong-Chul;Chong, Kil-To
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.5
    • /
    • pp.463-468
    • /
    • 2010
  • An obstacle avoidance method for a mobile robot is proposed in this paper. Our research was focused on the obstacles that can be found indoors since a robot is usually used within a building. It is necessary that the robot maintain the desired direction after successfully avoiding the obstacles to achieve a good autonomous navigation performance for the specified project mission. Sensors such as laser, ultrasound, and PSD (Position Sensitive Detector) can be used to detect and analyze the obstacles. A PSD sensor was used to detect and measure the height and width of the obstacles on the floor. The PSD sensor was carefully calibrated before measuring the obstacles to achieve better accuracy. Data obtained from the repeated experiments were used to plot an error graph which was fitted to a polynomial curve. The polynomial equation was used to navigate the robot. We also obtained a direction-error model of the robot after avoiding the obstacles. The prototypes for the obstacle and direction-error were modeled using a neural network whose inputs are the obstacle height, robot speed, direction of the wheels, and the error in direction. A mobile robot operated by a notebook computer was setup and the proposed algorithm was used to navigate the robot and avoid the obstacles. The results showed that our algorithm performed very well during the experiments.

Facet Joint Syndrome (추간관절 증후군)

  • Kang, Jeom-Deok
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.15 no.2
    • /
    • pp.93-97
    • /
    • 2009
  • Anatomy: Facet joint syndrome most often affects the lower back and neck and refers to pain that occurs in the facet joints, which are the connections between the vertebrae in the spine that enable the spine to bend and twist. Many physicians have believed that the usual lesion of facet syndrome was an anatomical impairments of facet joint itself.. Facet joint injection using local anesthetics is a reliable method for the diagnosis and treatment for facet syndrome. Etiology: One of many possible causes is imbalances that can occur in stress levels, hormone levels, and nutritional levels. These imbalances can adversely affect posture, which can lead to neck and back pain. The common disorder called facet syndrome exhibits lower back pain, with or without, radiating pain to buttock and thigh due to facet joint arthropathy. Pain in the facet joint is supposedly the secondary effect of narrowing of joint space by sustained muscle contracture around joints. Syndrome: Facet joint syndrome tends to produce pain or tenderness in the lower back that increases with twisting or arching the body, as well as pain that moves to the buttocks or the back of the thighs. Other symptoms include stiffness or difficulty standing up straight or getting out of a chair. Pain can be felt in other areas such as the shoulders or mid-back area. Treatment: Non-drug treatments include hot packs, ultrasound, electrical stimulation, and therapeutic exercises. Stimulating blood flow using massage or a hot tub may also help. Alternative treatments include yoga and relaxation therapy. If your pain persists after trying these treatments, a surgical procedure called radiofrequency rhizotomy, which destroys the sensory nerves of the joint, may bring relief. Facet joint injection has been helpful in diagnosis and therapy for this facet syndrome. Radiofrequency thermocoagulation of medial branches is known to be an effective method of relieving pain caused by facet joint problems. We conclude that spasmolytic treatment of muscles connecting the two vertebral articular space would be better for treatment and diagnosis of facet syndrome rather than facet block with local anesthetic and steroid only.

  • PDF

Detecting the Prostate Boundary with Gabor Texture Features Average Shape Model of TRUS Prostate Image (TRUS 전립선 영상에서 가버 텍스처 특징 추출과 평균형상모델을 적용한 전립선 경계 검출)

  • Kim, Hee Min;Hong, Seok Won;Seo, Yeong Geon;Kim, Sang Bok
    • Journal of Digital Contents Society
    • /
    • v.16 no.5
    • /
    • pp.717-725
    • /
    • 2015
  • Prostate images have been used in the diagnosis of prostate using TRUS images being relatively cheap. Ultrasound images are recorded with 3 dimension and one diagnostic exam is made with a number of the images. A doctor can see 2 dimensional images on the monitor sequentially and 3 dimensional ones to diagnose a disease. To display the images, 2-d images are used with raw 2-d ones, but 3-d images need to be segmented by the prostates and their backgrounds to be seen from different angles and with cut images of inner side. Especially on detecting the boundary, the ones in the middle of all images are easy to find the boundary but the base and apex of the images are hard to do it since there are lots of uncertain boundary. So, in this paper we propose the method that applies an average shape model and detects the boundary, and shows its superiority compared to the existing methods with experiments.

Wave Generation and Its Effect on Lesion Detection in Sonoelastography: Theory and Simulation Study (음향 탄성영상법에서 연조직 내 파동 발생과 병변 검출의 특성: 이론 및 시뮬레이션 연구)

  • 박정만;권성재;정목근
    • The Journal of the Acoustical Society of Korea
    • /
    • v.24 no.5
    • /
    • pp.282-293
    • /
    • 2005
  • Sonoelastography is an ultrasound-based technique that visualizes the elastic properties of soft tissues by measuring the tissue motion generated by an externally applied vibration. In this paper. the characteristics of wave generation in soft tissues due to an acoustic vibrator are studied. The effects of modal patterns on the detectability of lesions such as tumors in senoelastography are also investigated These are accomplished by analyzing the vibration patterns calculated using theoretical equations and finite element methods in halt space, infinite plate. and finite-sized tissue. A finite-width source generates shear waves with large amplitude Propagating in specific directions. and the generation characteristics depend both on the width and frequency of the vibrator. as well as the distance from it. It is shown in a finite-sized tissue that the lesion detection in displacement images is quit dependent on the modal patterns inside tissue. In contrast it Is also found that the lesion detectability in strain images is less dependent on the modal Patterns and is much better than that in displacement images.