• Title/Summary/Keyword: ultrasonic transducer

Search Result 605, Processing Time 0.024 seconds

Modeling and Analysis of Ultrasonic Transducer with Single Crystal Piezoelectric Material (압전단결정을 이용한 초음파 탐촉자 모델링 및 해석)

  • Kwon, Byung-Jin
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.579-580
    • /
    • 2014
  • In this research, modeling and analysis of an ultrasonic transducer composed of single crystal piezoelectric material(PMN-28PT) are conducted with FEM in reference with that composed of piezoelectric ceramic(PZT-4). Acoustic performances of the ultrasonic transducer are compared with magnitude, phase of impedance and trasmitting voltage response according to the type of piezoelectric materials.

  • PDF

Study on Electrical Impedance Matching for Broadband Ultrasonic Transducer (광대역 초음파 변환기를 위한 전기 임피던스 정합 연구)

  • Kim, Geonwoo;Kim, Ki-Bok;Baek, Kwang Sae
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.37 no.1
    • /
    • pp.37-43
    • /
    • 2017
  • Ultrasonic transducers with high resolution and resonant frequency are required to detect small defects (less than hundreds of ${\mu}m$) by ultrasonic testing. The resonance frequency and resolution of an ultrasonic transducer are closely related to the thickness of piezo-electric materials, backing materials, and the electric impedance matching technique. Among these factors, electrical impedance matching plays an important role because it can reduce the loss and reflection of ultrasonic energy differences in electrical impedance between an ultrasonic transducer and an ultrasonic defects detecting system. An LC matching circuit is the most frequently used electric matching method. It is necessary for the electrical impedance of an ultrasonic transducer to correspond to approximately $50{\Omega}$ to compensate the difference in electrical impedance between both connections. In this study, a 15 MHz immersion ultrasonic transducer was fabricated and an LC electrical impedance circuit was applied to that for having broad-band frequency characteristic.

Aluminum Wire Bonding by Longitudinal Vibration of Ultrasonic Transducer (초음파 트랜스듀서의 종진동을 이용한 알루미늄 와이어 용접)

  • Lee, G.B.;Kim, H.S.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.13 no.11
    • /
    • pp.38-45
    • /
    • 1996
  • In recent years, ultrasonic has been widely applied in measurement and industrial fields and its application range has been expanded as a result of continuous research and development. Wire Bonding Machine, an instrument fabricating semi-conductor, makes use of ultrasonic bonding method. Specially, the method utilizes the longitudinal vibration of ultrasonic transducer composed of piezoelectric vibrator and horn. This work investigates the design conditions affecting the dynamic characteristics through the theretical and experimental analysis. It conducts separately the system identification of piezoelectric vibrator in time domain and the modal analysis of horn in frequency domain. The integrated modeling is conducted via a combbination of dynamic identification of piezoelectric vibrator and theroretical analysis of horn. Then comparison is made for theroretical and experimental results of the dynamic characteristics of the ultrasonic transducer comprised of piezoelectric vibrator and horn. Form the results of the comparison we develop the design technique of ultrasonic transducer using dynamic characteristics analysis and propose the possibility of ultrasonic bonding considering the optimal conditions for the longitudinal vibration of ultrasonic transducer and other conditions.

  • PDF

A Study on the Actual Output and Thermal Effect in Tissue Mimicking Phantom by the Material of the Ultrasonic Transducer (초음파트랜스듀서의 재질에 따른 실출력과 인체모사조직의 온열효과에 관한 연구)

  • Yoo, Sang-Hyun;Choi, Won-Jae;Lee, Seung-Won
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.10 no.1
    • /
    • pp.91-97
    • /
    • 2015
  • PURPOSE: In this study investigated the thermal effect in tissue mimicking phantom by the material of the ultrasonic transducer in low intensity sonication. METHODS: The material of the ultrasonic transducer was made of ceramic, stainless steel, aluminum. Korea Testing Laboratory was measured of the three kinds of materials the total output of the ultrasonic transducer. Each material was measured core temperature and the actual output depending on the type of transducer. Agarose tissue mimicking phantom and silicone tissue mimicking phantom was made. Transducers made of three kinds of materials were emitted in the phantom. It is shown as a graph about time and temperature and the surface temperature rising speed and deep temperature rise rate was investigated. RESULTS: Ceramic transducers were highest output. Higher than the stainless steel transducer, aluminum had the lowest total output. Deep temperature was the highest in the ceramic transducer, and the surface temperature was the highest in the stainless steel transducer. Thermal images of ceramic transducer showed that a valid output is formed deeper wider than the metal. CONCLUSION: Ceramic transducer is confirmed the excellence than the metal transducer in deep thermal effect and the actual output of the ultrasound.

Output power maximizing in ultrasonic transducer driven at 1MHz utilizing auto-tune MOS-FET RF inverter

  • Mizutani, Yoko;Suzuki, Taiju;Ikeda Hiroaki;Yoshida, Hirofumi
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1995.10a
    • /
    • pp.87-90
    • /
    • 1995
  • When the ultrasonic transducer operating at l MHz for use in cleaning semiconductor wafers or other industsrial materials is driven from the MOS-FET DC-to RF inverter, the output power severely depends on the frequency of operation since the quality factor of the transducer is high. In order to tune to the eresonating frequency of the ultrasonic transducer, the drive signal frequency of the MOS-FET power inverter is automatically scananed until the frequency is set at the resonating frequency of the ultrasonic transducer is maximized. The control circuit consists of an output power sensing circuit, a PLL controller, a frequency standard, and other peripheral circuits. The operation was satisfactory when the transducer having an output of 600 W at 1 MHz was used.

  • PDF

Linear Ultrasonic Motor by Bimorph (Bimorph 형 선형 초음파 모터)

  • Seo, San-Dong;Park, Tae-Gon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.404-407
    • /
    • 2004
  • Linear ultrasonic motor by bimorph. Transducer for linear ultrasonic motor with symmetric and anti-symmetric modes was studied. The transducer was composed of two piezoelectric ceramic that cross at right angles with each other at tip. In order to exist length vibration mode two piezoelectric ceramics must have 90-degree phase difference with each other. As a result, tip of transducer moves in elliptical motion. Elliptical trajectory of transducer was analyzed by employing the (mite element method(FEM). From the result, the linear ultrasonic motor was measured for characteristics. In this paper, vibration shape of transducer was simulated and the resonant frequency, stabilization frequency and maximum displacement were calculated using the FEA.

  • PDF

Design and Analysis of Linear Ultrasonic Motor Using two Langevin Type Transducer (2개의 Langevin 진동자를 이용한 선형 초음파 모터의 설계와 해석)

  • Seo, San-Dong;Park, Tae-Gone
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.04b
    • /
    • pp.187-190
    • /
    • 2004
  • Transducer for ultrasonic linear motor with the symmetric and anti-symmetric modes was studied. The ultrasonic liner motor consists of two Lngevin type piezoelectric vibrators that cross at right angles with each other in tip. In order to excite symmetric and anti-symmetric mode, the transducer must have a 90 degree phase difference of voltage. Therefore, the tip of transducer moves on an elliptical motion. In this paper, the finite element analysis was used. The ultrasonic motor was fabricated using the simulated result and the driving characteristics were measured.

  • PDF

A Study on Fabrication and Characteristics of PVDF Ultrasonic Transducer (PVDF 초음파 변환기의 제작과 특성에 관한 연구)

  • Jung, Hong-Ryang
    • Journal of radiological science and technology
    • /
    • v.23 no.2
    • /
    • pp.33-37
    • /
    • 2000
  • The authors fabricated ultrasonic transducer with PVDF[poly(vinylidene fluoride)] piezoelectric polymer film. When impulse waves were applied to the PVDF ultrasonic transducer, the dependence of the response properties on the backing material with copper was investigated through not only theoretical calculations using Mason's equivalent circuit but also experimental measurements. The experimental pulse response properties agree with those of the theoretical calculations and the pulses were shorter than those for a PZT transducer. If such short-pulse properties are used in an medical ultrasonic image diagnosis apparatus, the resolution of the apparatus will be improved. When the insertion loss was calculated theoretically to the PVDF ultrasonic transducer, the frequency characteristics of its showed wideband frequency.

  • PDF

A new ultrasonic power generator using instantaneous current resultant control-based inverter and its control system

  • Kim, Dong-Hee;Kim, Young-Seok;Yoo, Dong-Wook;Kim, Yo-Hee
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1987.10b
    • /
    • pp.631-636
    • /
    • 1987
  • The design of ultrasonic transducer energy processing systems requires highly reliable command featuring mechanical frequency tracking and constant velocity control of the ultrasonic transducer with an acoustic load. This paper presents a new conceptional instantaneous current resultant control base high-frequency inverter using self turn-off devices driving an electrostrictive ultrasonic transducer system and its optimum control technique, which is implemented by feed-back of the ultrasonic transducer applied voltage and instantaneous velocity of the transducer vibrating system through a Phase-Locked-Loop control scheme. The feedback voltage corresponding to instantaneous velocity is averaged over a half-period with respect to constant amplitude/constant velocity control strategy. Described are the theory of this signal detection technique and the experimental set-up.

  • PDF

Development of a High-power Ultrasonic System for Sonochemistry Reaction (음향화학 반응용 강력초음파 개발)

  • Lee, Yang-Lae;Kim, Hyun-Se;Baek, Min-Hyuck
    • Journal of Power System Engineering
    • /
    • v.17 no.6
    • /
    • pp.142-148
    • /
    • 2013
  • High-power ultrasonic promotes a chemical reaction by its own energy, thus it has been used for sonochemistry applications. For example, it has been mostly used for mixing, reaction catalyst, dispersion and disintegration. High-power ultrasonic transducer is made with structure based on a Bolt-clamped Langevin type Transducer (BLT), But it has difficulty in the development because degradation of piezoelectric ceramic by the heat generation of BLT. In this study, for a development of the transducer of 25 kHz and 1000 W used in sonochemistry and industrial cleaning, BLT with a hole in its center and tubular type waveguide of the transducer were designed based on finite element method (FEM). The transducer was fabricated based on the design parameter, and the impedance characteristics are measured experimentally and compared with the numerical results.