• Title/Summary/Keyword: ultrasonic radiation

Search Result 133, Processing Time 0.024 seconds

A Study on the Size Control of Nanosized Polystyrene (폴리스타일렌 나노입자의 입도 조절에 관한 연구)

  • Tan, Ming Ning;Park, Yong Sung
    • Applied Chemistry for Engineering
    • /
    • v.22 no.4
    • /
    • pp.444-446
    • /
    • 2011
  • Nanosized polystyrene (PS) particles with the narrow size distribution were synthesized from styrene monomer at the presence of the surfactant (polyvinylpyrrolidone, PVP), the solvent of 95 % alcohol, and the initiator of benzoyl peroxide (BPO). Since the emulsion polymerization method was applied, many factors could have effects on the size of PS particles during polymeric process. Aside from the concentration of monomer, surfactant and initiator, the factors such as the stirring speed and the ultrasonic radiation were mainly studied. By adjusting the radiating time, PS particles with their size of about 400 nm were synthesized.

Study on 3-D Physical Modeling for the Inspection of Tunnel Lining Structure by using Ultrasonic Reflection Method (터널 지보구조 진단을 위한 초음파 반사법을 이용한 3차원 모형실험 연구)

  • 김중열;김유성;신용석;현혜자
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.03a
    • /
    • pp.221-228
    • /
    • 2002
  • Thickness of concrete lining, voids at the back of lining or shotcrete are very important elements for inspecting the safety of tunnels. Therefore, the inspection of tunnel lining structure means to investigate the inner layer boundaries of the structure. For this purpose, seismic reflection survey is the most desirable method if it works in good conditions. However, the conventional seismic reflection method can not be properly used for investigating thin layers in the lining structure. In other words, to detect the inner boundaries, it is desirable for the wavelength of source to be less than the thickness of each layer and for the receiver to be capable of detecting high frequency(ultrasonic) signals. To this end, new appropriate source and receiver devices should be developed above all for the ultrasonic reflection survey. This paper deals primarily with the development of source and receiver devices which are essential parts of field measuring system. Interests are above all centered in both the radiation pattern, energy, frequency content of the source and the directional sensitivity of the receiver. With these newly devised ones, ultrasonic physical modeling has been performed on 3-D physical model composed of bakelite, water-proof and concrete, The measured seismograms showed a clear separation of wave arrivals reflected from each layer boundary. Furthermore, it is noteworthy that reflection events from the bottom of concrete below water-proof could be also observed. This result demonstrates the usefulness of the both devices that can be applied to benefit the ultrasonic reflection survey. Future research is being focus on dealing with at first an optimal configuration of source and receiver devices well coupled to tunnel wall, and further an efficient data control system of practical use.

  • PDF

A Study on the Design and Fabrication of Fat Emulsification Adapted Focused Ultrasonic Transducer (지방 조직 유화를 위한 집속형 초음파 변환기 설계 및 제작에 관한 연구)

  • Kim, Ju-Young;Kim, Jae-Young;Jung, Hyun-Du;Noh, Si-Cheol;Mun, Chang-Su;Mun, Chi-Woong;Choi, Heung-Ho
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.11
    • /
    • pp.127-134
    • /
    • 2015
  • Tissue stimulation technique using ultrasound has been continuously studied and developed. Recently, as a increment of interests for obesity treatment and cosmetic care, a various studies on ultrasonic fat emulsification has been conducted. In this study, the fat emulsification adapted ultrasonic transducer was designed. And using designed transducer, the simulation for the shape of focal area and thermal degradation region was conducted. The dimensions were verified by the simulation results. And the effectiveness was confirmed by evaluating measured radiation characteristic and heating characteristic. In addition, we estimated the ultrasonic heating characteristics in composite structure medium. The shape of focal point and heating characteristic of the proposed transducer were determined to be sufficient to emulsify the fat. The results of this study are considered to be used as basic research in more efficient and safe ultrasonic fat removal.

Improvement of the Radiation Beam Profile of a Medical Ultrasonic Transducer (의료용 초음파 트랜스듀서의 방사 빔 형상 개선)

  • Park, Yeonsue;Lee, Wonseok;Roh, Yongrae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.34 no.4
    • /
    • pp.264-273
    • /
    • 2015
  • Improvement of the radiation beam profile of a medical ultrasonic transducer has been researched in this paper. In order to improve the beam profile, a new transducer structure has been devised that includes both a shaded electrode and a multi-focus lens. For a linear sound source, the beam profile was investigated through finite element analysis, and then the optimal design of the devised structure was carried out by considering such performances as sidelobe level, focal range and beamwidth simultaneously. In the process, the optimal dimension of the devised structure was derived by using the ratio of the focal range to the minimum beamwidth as a performance index. As a result, the beam profile has been improved to have a lower sidelobe level at -20.2 dB and a consistent narrow beamwidth from 30 mm to 160 mm depth with the minimum beamwidth at 2.04 mm. Further, a prototype transducer was fabricated to have the devised structure, and its performance was measured and compared with the analysis results to confirm the validity of the devised transducer structure.

Microscopic Examination of Fracture Particles on the Surface of Ir-192 Sealed Source and Ultrasonic Cleaning (Ir-192 밀봉선원의 표면오염 방지)

  • Kuk, Il Hiun;Park, Chun Deuk;Koo, Ja Ho
    • Journal of Radiation Industry
    • /
    • v.9 no.2
    • /
    • pp.91-102
    • /
    • 2015
  • The iridium disc, generally used in industrial radiography, is examined to find the fracture morphology and fine particles remaining on the shear blank surface. Randomly selected 1,200 discs were observed under a scanning electron microscope tilted more than $45^{\circ}$. Fracture surfaces are classified into three groups: (1) surface fall-out, (2) fracture on the edge and (3) multi-step brittle fracture, which shows the mutual relationship between the fracture morphology and remaining particles. Fracture particles were removed by cleaning the discs in a ultrasonic bath with acetone and collected at the bottom. Removed number of the particles were counted for each different group of fracture surfaces. Followings are conclusions: (1) About 80.5% of discs (966/1,200), have sound plastic shear surfaces with particles remained. (2) About 2% discs accompany surface fall-out's having large particles tens of ${\mu}m$, which is stable not to be pulled out even after the considerably long time of ultrasonic cleaning. (3) About 5% discs contain the fractures on the edge and the particles are removed thoroughly within 30 minutes. (4) 234 discs out of 1,200 discs have multi-step fracture surfaces whose particles never removed in a short period of time but come out very slowly. Such a disc having multiple-step fracture is attributed to the promate cause to the 'leaker'. It is noted here that the discs having mutiple-step fractures should be treated separately with special care, and it is need to study how to treat them.

Kinetic examination on synergistic effect of co-use of ultrasonic wave and ultraviolet radiation on bacterial disinfection in a household humidifier (초음파와 자외선(UV) 동시 적용이 가정용 가습기 내 살균에 미치는 시너지 효과에 대한 반응속도론적 연구)

  • Kim, Seunga;Kim, Jihyun;Lee, Minjoo;Kim, Jayun;Jung, Woosik;Park, Joonhong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.35 no.3
    • /
    • pp.227-235
    • /
    • 2021
  • This study examined the effect of ultraviolet (UV) application on bacterial disinfection in a commercialized humidifier using ultrasonic wave (UW). To accurately examine disinfection kinetics in tap-water condition, tap-water was sterilized using a filter, and then inoculated with pure cultures of E. coli and P. putida with known viable counts. The disinfection kinetic characteristics were experimentally compared when UV alone, UW alone, and UW+UV together were applied in disinfecting the added bacteria in the commercialized humidifier. When UV alone was applied, bacterial disinfection kinetics followed a first-order decay reaction, and showed an approximately 10-time weaker disinfection compared to the typical UV disinfection in water treatment or wastewater treatment. When UW alone was applied, bacterial disinfection kinetics followed a second-order decay reaction with a low disinfection rate constant of 0.0002 min-1(CFU/mL)-1. When UV and UW were applied together, however and interestingly, the disinfection rate constant (0.0211 min-1(CFU/mL)-1) was approximately 100 times increased than that for the UW alone case. These results revealed that the co-use of UV and UW can provide synergistic effect on bacterial disinfection in a tap-water condition in household humidifiers.

Bladder filling variations during concurrent chemotherapy and pelvic radiotherapy in rectal cancer patients: early experience of bladder volume assessment using ultrasound scanner

  • Chang, Jee Suk;Yoon, Hong In;Cha, Hye Jung;Chung, Yoonsun;Cho, Yeona;Keum, Ki Chang;Koom, Woong Sub
    • Radiation Oncology Journal
    • /
    • v.31 no.1
    • /
    • pp.41-47
    • /
    • 2013
  • Purpose: To describe the early experience of analyzing variations and time trends in bladder volume of the rectal cancer patients who received bladder ultrasound scan. Materials and Methods: We identified 20 consecutive rectal cancer patients who received whole pelvic radiotherapy (RT) and bladder ultrasound scan between February and April 2012. Before simulation and during the entire course of treatment, patients were scanned with portable automated ultrasonic bladder scanner, 5 times consecutively, and the median value was reported. Then a radiation oncologist contoured the bladder inner wall shown on simulation computed tomography (CT) and calculated its volume. Results: Before simulation, the median bladder volume measured using simulation CT and bladder ultrasound scan was 427 mL (range, 74 to 1,172 mL) and 417 mL (range, 147 to 1,245 mL), respectively. There was strong linear correlation (R = 0.93, p < 0.001) between the two results. During the course of treatment, there were wide variations in the bladder volume and every time, measurements were below the baseline with statistical significance (12/16). At 6 weeks after RT, the median volume was reduced by 59.3% to 175 mL. Compared to the baseline, bladder volume was reduced by 38% or 161 mL on average every week for 6 weeks. Conclusion: To our knowledge, this study is the first to prove that there are bladder volume variations and a reduction in bladder volume in rectal cancer patients. Moreover, our results will serve as the basis for implementation of bladder training to patients receiving RT with full bladder.

A Novel Cooling Method by Acoustic Streaming Induced by Ultrasonic Resonator (초음파 진동자에 의해 유도된 음향유동을 이용한 첨단 냉각법)

  • 노병국;이동렬
    • The Journal of the Acoustical Society of Korea
    • /
    • v.22 no.3
    • /
    • pp.217-223
    • /
    • 2003
  • A novel cooling method induced by acoustic streaming generated by ultrasonic vibration at 30㎑ is presented. Ultrasonic vibration is obtained by piezoelectric devices and the maximum vibration amplitude of 50 m is achieved by including a horn, mechanical vibration amplifier in the system and making the complete system resonate. To investigate the enhancement of heat transfer capability of acoustic streaming, the temperature variations of heat source and air in the vicinity of heat source are measured in real-time. It is observed that acoustic streaming is instantly induced by ultrasonic vibration, resulting in the significant temperature drop due to the bulk air flow caused by acoustic streaming. In addition, it is observed that the cooling effect on the heat source is maximized when the gap between the ultrasonic vibrator and heat source coincides with the multiples of half-wavelength of the ultrasonic wave. This fact results from the resonance of the sound wave. The theoretical analysis of the dependence on the gap is also accomplished and verified by experiment. The advantage of the proposed cooling method by acoustic streaming is noise-free due to the ultrasonic vibration and maintenance-free because of the absence of moving parts. Moreover. This cooling method can be utilized to the nano and micro-electro mechanical systems, where the fan-based conventional cooling method can not be employed.

Evaluation of high power ultrasonic energy transmission characteristics of a liquid matching layer by using sonoluminescence (소노루미네센스를 이용한 액체정합층의 고출력 초음파에너지 전달특성 평가)

  • Kim, Jungsoon;Kim, Haeun;Son, Jinyoung;Kim, Moojoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.40 no.5
    • /
    • pp.408-416
    • /
    • 2021
  • In the ultrasonic dispersion, in order to avoid direct contact of the radiation surface of ultrasonic transducers with a liquid sample, the liquid sample is separated by a glass container and it receives ultrasonic energy through an acoustic medium. The transmission efficiency of the ultrasonic energy in the multi-layered ultrasonic system is an important factor. In this study, we suggested a method that can improve the ultrasonic energy transfer efficiency by using a propylene glycol solution as a liquid matching layer in the multi-layered acoustic system. In this method, a propylene glycol solution was filled between the Langevin-type ultrasonic transducer and the luminol solution and the sonoluminescence phenomena in the luminol solution, which is caused by nonlinear effect of high power ultrasound radiated from the transducer, was examined by using a Photo Multiplier Tube (PMT). The transmission efficiency depending on the concentration of propylene glycol solution was observed, and we can see that as the concentration of the propylene glycol solution increased, the matching effect increased while the acoustic attenuation increased. It was confirmed that there is an optimal concentration compromised these two conflicting conditions, and the optimum concentration of the propylene glycol solution was determined experimentally.

Development of a Guided Wave Technique for the Inspection of a Feeder Pipe in a Pressurized Heavy Water Reactor

  • Cheong, Yong-Moo;Lee, Dong-Hoon;Kim, Sang-Soo;Jung, Hyun-Kyu
    • Corrosion Science and Technology
    • /
    • v.4 no.3
    • /
    • pp.108-113
    • /
    • 2005
  • One of the recent safety issues in the pressurized heavy water reactor (PHWR) is the cracking of the feeder pipe. Because of the limited accessibility to the cracked region and a high dose of radiation exposure, it is difficult to inspect all the pipes with the conventional ultrasonic method. In order to solve this problem, a long-range guided wave technique has been developed. A computer program to calculate the dispersion curves in the pipe was developed and the dispersion curves for the feeder pipes in PHWR plants were determined. Several longitudinal and/or flexural modes were selected from the review of the dispersion curves and an actual experiment has been carried out with the specific alignment of the piezoelectric ultrasonic transducers. They were confirmed as L(0,1)) and/or flexural modes(F(m,2)) by the short time Fourier transformation(STFT) and were sensitive to the circumferential cracks, but not to the axial cracks in the pipe. An electromagnetic acoustic transducers(EMAT) was designed and fabricated for the generation and reception of the torsional guided wave. The axial cracks were detected by a torsional mode(T(0,1)) generated by the EMAT.