• Title/Summary/Keyword: ultrasonic nozzle

Search Result 77, Processing Time 0.024 seconds

Fabrication of anti-reflection thin film by using sol-gel hybrid solution (Sol-gel 하이브리드 용액을 이용한 반사방지막 제조)

  • Park, Jong-Guk;Lee, Ji-Sun;Lee, Mi-Jai;Lee, Young Jin;Jeon, Dae-Woo;Kim, Jin-Ho
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.26 no.6
    • /
    • pp.220-224
    • /
    • 2016
  • Anti-reflection (AR) thin films were fabricated on a glass substrate by using an ultrasonic spray. Glycidoxypropyl trimethoxysilane (GPTMS) and tetraethyl orthosilicate (TEOS) were used to synthesize a sol-gel hybrid coating solution. The moving speed of spray nozzle was changed from 15~25 mm/s to control the coating thickness of AR thin film. As the moving speed of spray nozzle increased, the thickness of AR thin film decreased from 138 nm to 86 nm. When the AR thin film was fabricated by nozzle moving speed of 20 mm/s, the refractive index and thickness of AR thin film was measured to be 1.31 and 104 nm, respectively. The average reflectance and transmittance of AR thin film coating glass was measured to be 0.75 % and 94 %, respectively into the visible light range of 380~780 nm.

Precise ultrasonic coating and controlled release of sirolimus with biodegradable polymers for drug-eluting stent

  • Joung, Yoon Ki;Jang, Bu Nam;Kang, Jong Hee;Han, Dong Keun
    • Biomaterials and Biomechanics in Bioengineering
    • /
    • v.1 no.1
    • /
    • pp.13-25
    • /
    • 2014
  • In the current study, a drug-eluting stent coated with biodegradable polymers and sirolimus was developed by using an ultrasonic nanocoater and characterized in aspects of surface smoothness and coating thickness. In addition, in vitro release profiles of sirolimus by changing top coating layer with different biodegradable polymers were investigated. Smooth surfaces with variable thickness could be fabricated by optimizing polymer concentration, flow rate, nozzle-tip distance, gas pressure, various solvents and ultrasonic power. Smooth surface could be generated by using volatile solvents (acetone, chloroform, and methylene chloride) or post-treating with solvent vapor. Coating thickness could be controlled by varying injection volume or polymer concentration, and higher concentration could reduce the coating time while obtaining the same thickness. The thickness measurement was the most effectively performed by a conventional cutting method among three different methods that were investigated in this study. Release profiles of sirolimus were effectively controlled by changing polymers for top layer. PLGA made the release rate 3 times faster than PDLLA and PLLA and all top layers prevented burst release at the initial phase of profiles. Our results will provide useful and informative knowledge for developing drug-eluting stents, especially coated with biodegradable polymers.

A Study on Flow Characteristics with Ultrasonic Forcing in a Coaxial Circular Pipe by PIV Measurement (동심원관내에서 초음파가 가진된 유동특성의 PIV계측에 의한 연구)

  • Koo, J.H.;Park, Y.H.;Choi, W.C.;Song, M.G.;Ju, E.S.
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.639-644
    • /
    • 2000
  • An experiment on the enhancement of turbulent flow with ultrasonic forcing was carried out by using PIV measurement in a coaxial circular pipe which could offer characteristics of the turbulence flow plentifully through its jet. A large transparent acryl tank and a coaxial circular pipe nozzle were made for the above research. city water of $25^{\circ}C$ was selected as an experimental liquid and the front flow field of the coaxial circular pipe was divided vertically as 3 measuring regions to observe characteristics of flow phenomena. characteristics of fluid flow such as velocity vector distribution, kinetic energy, turbulent intensity and etc. were visualized, observed, examined and considered at 5 kinds of Re No. such as $Re=1{\times}10^3,\;2{\times}10^3,\;3{\times}10^3,\;5{\times}10^3,\;1{\times}10^4$. In result it was proved that ultrasonic vibration affected the enhancement of turbulent flow.

  • PDF

A Behavior of the Ultrasonically-atomized Kerosene Lifted-flame According to the Position of Ultrasonic Standing-wave Field (정상초음파장의 위치에 따른 초음파 무화 케로신 부상화염의 거동)

  • Chang Han Bae;Jeong Soo Kim
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.27 no.1
    • /
    • pp.1-8
    • /
    • 2023
  • A study was conducted to scrutinize the behavior of the ultrasonically-atomized kerosene lifted-flame according to the carrier gas flow-rate and position of ultrasonic standing wave (USW). The combustion region of the kerosene-aerosol generated through a slit-jet nozzle was visualized using a DSLR, ICCD, high-speed camera, and Schlieren technique, and the fuel consumption was measured by using a precision balance. As a result, the flame was confined within the region bounded by the USW-field, and the fuel consumption decreased as the position of the USW field increased.

Ultrasonic Transducer Design for the Axial Flaw Detection of Dissimilar Metal Weld (이종금속 용접부 축방향 결함 검출을 위한 초음파 탐촉자 설계)

  • Yoon, Byung-Sik;Kim, Yong-Sik;Yang, Seung-Han
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.5
    • /
    • pp.536-542
    • /
    • 2011
  • Dissimilar metal welds in nuclear power plant are known as very susceptible to PWSCC flaws, and periodically inspected by the qualified inspector and qualified procedure during in-service inspection period. According to field survey data, the majority of their DMWs are located on tapered nozzle or adjacent to a tapered component. These types of configurations restrict examination access and also limit examination volume coverage. Additionally, circumferential scan for axially oriented flaw is very difficult to detect located on tapered surface because the transducer can't receive flaw response from reflector for miss-orientation. To overcome this miss-orientation, it is necessary adapt skewed ultrasonic transducer accomodate tapered surface. The skewed refracted longitudinal ultrasonic transducer designed by modeling and manufactured from the modelling result for axial flaw detection. Experimental results showed that the skewed refracted longitudinal ultrasonic transducer get higher flaw response than non-skewed refracted longitudinal ultrasonic transducer.

Photoresist spray coating for three-dimensional micro structure (3차원 마이크로 구조를 위한 포토레지스트 스프레이 코팅)

  • Kim, Do-Wook;Eun, Duk-Su;Bae, Young-Ho;Yu, In-Sik;Suk, Chang-Gil;Jeong, Jong-Hyun;Cho, Chan-Seop;Lee, Jong-Hyun
    • Journal of Sensor Science and Technology
    • /
    • v.15 no.3
    • /
    • pp.153-157
    • /
    • 2006
  • This paper presents the method for three-dimensional micro structure with photoresist spray coating system. The system consists of a high temperature rotational chuck, ultrasonic spray nozzle module, angle control module and nozzle moving module. Spray coating system is effected by several parameters such as the solid contents, the dispensed volume, the scanning speed of the spray nozzle and the wafer of dimension. The photoresist (AZ 1512) has been coated on the three-dimensional micro structure by spray coating system and the characteristics have been evaluated.

Nondestructive Evaluation for Thermally Degraded Co-base Superalloy by Scanning Acoustic Microscope (초음파현미경을 이용한 Co 기 초내열 합금 열화재의 비파괴평가)

  • Kim, Chung-Seok;Song, Jin-Hun;Kwon, Sook-In;Lim, Jea-Seang;Park, Ik-Keun
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.336-341
    • /
    • 2004
  • This research investigates the feasibility of ultrasonic microscope for nondestructive assessment of thermal degradation in artificially aged commercial Co-base superalloy, FSX414. This alloy has been used for high temperature structure applications such as stationary gas turbine blade and nozzle chamber in fossil plant. Microstructural change was found that the fine carbides became coarser and spheroidized in matrix as aging time increased. The leaky surface acoustic wave velocity gradually decreases by a maximum of 4.7% with increasing aging time up to 4,000hours. However, the longitudinal wave velocity has a little change. Also, it has a good correlation between leaky surface acoustic wave velocity and Vickers hardness. Consequently, LSAW can be used to examine the degree of degradation in thermally aged Co-base superalloy.

  • PDF

Combustion Characteristics of the Atomized Hydrocarbon Liquid-fuel Spray Injected through a Slit-jet Nozzle (Slit-jet 노즐을 통해 분사되는 탄화수소계 액체연료 분무의 연소특성)

  • Kim, Min Sung;Kim, Jeong Soo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.20 no.1
    • /
    • pp.43-49
    • /
    • 2016
  • An experimental study was performed to investigate the combustion characteristics of the liquid hydrocarbon fuel atomized by an ultrasonic oscillator. Configuration of the flame was caught by the DSLR camera, and images were analyzed in detail through a post-processing. Temperature of the flame zone was measured using thermocouple. It is resulted that the flame area is proportional to the mass flow rate of carrier gas as well as the voltage applied to the ultrasonic oscillator. Temperature of the flame zone is measured and analyzed according to variation in the operating condition of the burner, too.

A Study on the Development of Emulsified Fuel Supplier and Spray Characteristics of Domestic Petroleum Boiler (가정용 보일러의 유화연료 공급장치 개발 및 분무 특성에 관한 연구)

  • Yoon, M.K.;Kim, Y.K.;Ryu, J.Y.
    • Journal of ILASS-Korea
    • /
    • v.3 no.4
    • /
    • pp.8-15
    • /
    • 1998
  • The spray characteristics of emulsified fuel of W/O type has been experimentally investigated. The mixture of light oil and water by using ultrasonic energy adding system is used as the emulsified fuel. The SMD of sprayed droplet of emulsified fuel is measured by using the particle size analyzer. Major parameters of the present experimental study are the volume fraction of water in emulsified fuel, $0\sim30%$ by 5%, injection pressure, $10kg_f/cm^2\sim18kg_f/cm^2$ by $2kg_f/cm^2$, and the measurement distance, $10\sim100mm$, between injection nozzle tip and analyzer beam. Compared with light oil, the SMD of emulsified fuel is larger gradually by increasing the volume fraction of water in emulsified fuel, heightening injection pressure and increasing the spray distance. Also, In considering the fact that the pattern of drop size distribution of emulsified fuel is alike that of light oil, the real time spray in coincidence with making emulsified fuel by adding ultrasonic energy can stabilize spray pattern without modificating the injection system used by now.

  • PDF

Development of SAW Gas Sensor for Monitoring SOx Gas (SOx 가스감지용 SAW 가스 센서 개발)

  • Lee, Chan-Woo;Roh, Yong-Rae;Chung, Jong-Shik;Baik, Sung-Gi
    • Journal of Sensor Science and Technology
    • /
    • v.5 no.3
    • /
    • pp.41-48
    • /
    • 1996
  • We developed SAW gas sensor for monitoring SOx gas with high sensitivity. It was fabricated as a microsensor for detecting SOx gas by depositing sensing material on SAW device. As a detecting layer material, CdS was selected. Deposition of CdS in the form of thin films was carried out by the ultrasonic spray pyrolysis method using ultrasonic spray nozzle. Thin films with the uniform and large surface area for sensors were deposited. The stable pyrolysis environment provided by uniform and fine droplets formed by spray nozzle made it possible to obtain thin films with excellent quality. The minimum grain size of the CdS thin films was about 50 nm when deposited at $300^{\circ}C$. SAW gas sensors showed reasonable sensitivity and reproducibility. Further studies are required to investigate the interference of other gases to SOx gas detection.

  • PDF