• Title/Summary/Keyword: ultra-precision

Search Result 924, Processing Time 0.024 seconds

AFM-based nanofabrication with Femtosecond pulse laser radiation (원자간력 현미경(AFM)과 펨토초 펄스 레이저를 이용한 나노 형상 가공)

  • Kim Seung-Chul;Kim Seung-Woo
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.149-150
    • /
    • 2006
  • We describe a novel method of scanning probe nanofabrication using a AFM(atomic force microscopy) tip with assistance of Femtosecond laser pulses to enhance fabrication capability. Illumination of the AFM tip with ultra-short light pulses induces a strong electric field between the tip and the metal surface, which allows removing metal atoms from the surface by means of field evaporation. Quantum simulation reveals that the field evaporation is triggered even en air when the induced electric field reaches the level of a few volts per angstrom, which is low enough to avoid unwanted thermal damages on most metal surfaces. For experimental validation, a Ti: sapphire Femtosecond pulse laser with 10 fs pulse duration at 800 nm center wavelength was used with a tip coated with gold to fabricate nanostructures on a thin film gold surface. Experimental results demonstrate that fine structures with critical dimensions less than ${\sim}10nm$ can be successfully made with precise control of the repetition rate of Femtosecond laser pulses.

  • PDF

Fatigue Crack Propagation of Sliding Core in Artificial Intervertebral Disc due to the Fatigue Loading Mode (인공추간판의 피로하중 모드에 따른 슬라이딩 코어의 피로균열전파 거동)

  • Kim Cheol-Woong;Kang Bong-Su
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.367-368
    • /
    • 2006
  • Today, the Artificial Intervertebral Disc (AID) is being developed by increasing the oblique of the endplate gradually. In other words, Ultra-high Molecular Weight Polyethylene (UHMWPE) which is apply to the sliding core of the AID, does not change the shape but alters the oblique of endplate. However, the unreasonable increase of degree of freedom (DOF) can result in the aggravation of the bone fusion and the initial stability and it can also lead to the increase of the concentrated force in core. For these reasons, it is necessary to develop the advanced techniques, which choose the most adequate DOF. In this study, the new optimized modeling of the sliding core and the endplate, the fatigue characteristics, the crack propagation and the formation mechanism of wearing debris was studied and the minimizing technique will be derived from this research.

  • PDF

WFIRST ULTRA-PRECISE ASTROMETRY II: ASTEROSEISMOLOGY

  • Gould, Andrew;Huber, Daniel;Penny, Matthew;Stello, Dennis
    • Journal of The Korean Astronomical Society
    • /
    • v.48 no.2
    • /
    • pp.93-104
    • /
    • 2015
  • WFIRST microlensing observations will return high-precision parallaxes, σ(π) . 0.3 µas, for the roughly 1 million stars with H < 14 in its 2.8 deg2 field toward the Galactic bulge. Combined with its 40,000 epochs of high precision photometry (∼ 0.7 mmag at Hvega = 14 and ∼ 0.1 mmag at H = 8), this will yield a wealth of asteroseismic data of giant stars, primarily in the Galactic bulge but includindvvvvvg a substantial fraction of disk stars at all Galactocentric radii interior to the Sun. For brighter stars, the astrometric data will yield an external check on the radii derived from the two asteroseismic parameters, the large-frequency separation <∆νnl> and the frequency of maximum oscillation power νmax, while for the fainter ones, it will enable a mass measurement from the single measurable asteroseismic parameter νmax. Simulations based on Kepler data indicate that WFIRST will be capable of detecting oscillations in stars from slightly less luminous than the red clump to the tip of the red giant branch, yielding roughly 1 million detections.

Wear of Single Crystal Diamond(SCD) Tools in Ultra Precision Turning of Electro-Nickel Plated Drum (전해니켈도금된 대면적 롤금형 가공시 단결정 다이아몬드공구의 마모에 관한 연구)

  • Lee, D.Y.;Hong, S.H.;Kang, H.C.;Choi, H.Z.;Lee, S.W.
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.33 no.7
    • /
    • pp.621-628
    • /
    • 2009
  • Nickel-phosphorus alloys are attractive materials for diamond turning applications such as fabrication of large optics and other high precision parts. It is also well-known that the higher phosphorus content of the alloys minimizes the diamond tool wear. Due to the weakness of electoless nickel plating that the phosphorus contents is limited to 13-14% (wgt), increased attention has been paid at electro-nickel plating which enables the alloys with 15-16% phosphorus. In this study, experiments were carried out to observe the wear characteristic of single crystal diamond tools in micro-grooving of electro-nickel plated drums. The experiments shows that long distance (50km) machining of micro-grooving on electro-nickel plated drum is possible with a single crystal diamond tool without any significant tool wear and defective machined surface.

Design of the Low Hunting Controller for the Reticle Stage for Lithography (VCM을 이용한 노광기용 정밀 레티클 스테이지의 저진동 제어시스템 개발)

  • Kim, Mun-Su;Oh, Min-Taek;Kim, Jung-Han
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.17 no.4
    • /
    • pp.51-58
    • /
    • 2008
  • This paper presents a new design of the precision stage for the reticle in lithography process and a low hunting control method for the stage. The stage has three axes for X, Y, ${\theta}_z$ those actuated by three voice coil motors individually. The designed reticle stage system has three gap sensors and voice coil motors, and supported by four air bearings and the forward/inverse kinematics of the stage were solved to get an accurate reference position. When a stage is in regulating control mode, there always exist small fluctuations(stage hunting) in the stage movement. Because the low stage hunting characteristic is very important in recent lithography and nano-level applications, a special regulating controller for ultra low hunting is proposed in this paper. Also this research proposed the 2-step transmission system for preventing the noise infection from environmental devices. The experimental results showed the proposed regulating control system reduced hunting noise as 35nm(rms) when a conventional PID generates 77nm(rms) in the same mechanical system. Besides the reticle stage has 100nm linear accuracy and $1{\mu}rad$ rotation accuracy at the control frequency of 8kHz.

Accuracy Analysis of baseline determination using Broadcast ephemeris and Precise ephemeris in GPS surveying (방송력과 정밀력의 사용에 의한 GPS 측량의 정확도 분석)

  • Kim, Cheol-Young;Lee, Suk-Bae;Do, Sang-Gyeong
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.27 no.2
    • /
    • pp.149-157
    • /
    • 2009
  • The orbit ephemeris of Global Positioning System(GPS) is one element to determine the surveying accuracy and there are broadcasting ephemeris and precise ephemeris, IGS rapid orbit and IGS ultra rapid orbit in the orbit ephemeris of GPS. In this study, test area was selected in Uljin, Kyungsanbukdo and GPS surveying was accomplished at 37 points in the test area. Then baseline solution was done on 74 baseline using broadcasting ephemeris and precise ephemeris and analysis by TGO and the results were compared. Comparison results were showed that there were nearly no difference between the two results but in case of relative precision of the baseline, it was slightly better the baseline results of precise ephemeris which showed 0.706ppm than the baseline results of broadcasting ephemeris which showed 0.708ppm.

A Non-coherent UWB Direct Chaotic Ranging System for Precision Location and Positioning

  • Yang, Wan-Cheol;Lee, Sang-Yub;Lee, Kwang-Du;Kim, Ki-Hwan;Yang, Chang-Soo;Kim, Hak-Sun
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • v.2
    • /
    • pp.311-315
    • /
    • 2006
  • Precision location and positioning of Asset within a network is an attractive feature with various applications, especially in indoor environments. Such a demand is met by the standard task group, IEEE 802.15.4a. Several methods, that is, pulse, chirp and chaotic communications have been proposed so far to satisfy the requirements of the standard. Among them, ultra wideband direct chaotic communications has advantageous features such as low hardware complexity, low cost, lower power consumption and flexible frequency band plan. In this paper, the feasibility of the ranging system using non-coherent chaotic transceiver is investigated by designing and implementing the system and the performance is proved by conducting location experiments in real indoor environments.

  • PDF

Theoretical Analysis on the Optimum Fluence for Copper Ablation with a 515 nm Picosecond Laser (515 nm 피코초 레이저를 이용한 구리 어블레이션 공정의 최적 에너지밀도에 대한 이론적 분석)

  • Shin, Dongsig;Cho, Yongkwon;Sohn, Hyonkee
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.10
    • /
    • pp.1009-1015
    • /
    • 2013
  • Ultra-short laser pulses are effective, when high requirements concerning accuracy, surface roughness and heat affected zone are demanded for surface structuring. In particular, picosecond laser systems that are suited to be operated in industrial environments are of great interest for many practical applications. This paper focused on inducing optimum process parameters for higher volume ablation rate by analyzing a relationship between crater diameter and optical spot size. In detail, the dependency of the volume ablation rate, penetration depth and threshold fluence on the pulse duration 8 ps and wavelength of 515 nm was discussed. The experimental results showed that wavelength of 515 nm resulted in less threshold fluence ($0.075J/cm^2$) on copper than IR wavelength ($0.3J/cm^2$). As a result, it was possible that optimum fluence for higher volume ablation rate was achieved with $0.28J/cm^2$.

Basic Study in Fabrication and Mechanical Characteristics of Ultra Light Inner Structured and Bonded(ISB) Panel Containing Perpendicularly Woven Metal (수직방향 직조 금속망을 이용한 초경량 금속 내부구조 접합판재의 제작 및 특성에 관한 기초 연구)

  • Jung Chang Gyun;Yoon Seok-Joon;Yang Dong-Yol;Lee Sang Min;Na Suck-Joo;Lee Sang-hoon;Ahn Dong-Gyu
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.5 s.170
    • /
    • pp.152-158
    • /
    • 2005
  • Inner structured and bonded panel, or ISB Panel, as a kind of sandwich type panel, has metallic inner structures which have low relative density, due to their dimensional shape of metal between a pair of metal skin sheets or face sheets. Previous works showed that ISB panels containing inner structures formed as repeated pyramidal shapes saved weight up to $60\%$ in condition of same stiffness comparing with solid sheet. In this work, woven metal is adapted to inner structures replacing pyramidal structures. The test specimens of ISB panel containing woven metal made by multi-point electric resistance welding and 3-point bending test have been carried out. The results of experiments and comparisons of process parameters, stiffness and failure mode are discussed.

Atomic Force Microscopy Force Mapping Application in Biomedical Research (원자현미경의 나노 힘 측정을 이용한 생의학 연구에의 응용)

  • Cho S.J.;Lee D.J.;Kim E.P.;Lee D.R.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.77-80
    • /
    • 2005
  • Local probe techniques such as scanning probe microscopy (SPM) or atomic force microscopy (AFM) extended our perception into ultra small world. Specially, the sense of touching was extended by AFM into the micro- and nanoworld and has provided complementary new insights of the microscopic world. In addition, touching objects is an essential step before trying to manipulate things. SPM as a touch sensor not only measure the mechanical properties but also detect different properties such as magnetic, electrical, ionic, thermal, chemical and biophysical properties in nanoscale and even less. Obtaining biophysical measurements, monitoring dynamics and processes together with high-resolution imaging of the biomolecules and cells with rather simpler sample preparation than any other techniques give great attractions to the scientists experimenting with biological samples. Among the many AFM capabilities we will specifically introduce the force plot which is used to measure tip-sample interactions and its application this time.

  • PDF