• 제목/요약/키워드: ultra-low partial discharge

검색결과 8건 처리시간 0.03초

극미소 부분방전 측정시스템의 설계 및 제작 (Design and Fabrication of an Ultra-low Partial Discharge Measurement System)

  • 서황동;송재용;문승보;길경석;권장우
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2005년도 추계종합학술대회
    • /
    • pp.208-211
    • /
    • 2005
  • This paper presents an ultra-low partial discharge(PD) measurement system that has been accepted as a non-destructive method to estimate electrical insulation of low-voltage electric devices. The PD measurement system is composed of a coupling network, a low noise amplifier, and associated electronics. A shielding box is used to make a better condition against electromagnetic interference. A low cut-off frequency of the coupling network was 1MHz(-3 dB). Calibration tests on laboratory set-up have shown that the PD measurement system has a stable sensitivity of 11.4mV/pC. In an application experiment on a low-voltage induction motor(5HP), we could detect 0.77pC level of partial discharge pulse at the applied voltage of AC 664 V$_{peak}$.

  • PDF

PD Diagnosis on 22.9kV XLPE Underground Cable using Ultra-wideband Sensor

  • Lwin, Kyaw-Soe;Lim, Kwang-Jin;Park, Noh-Joon;Park, Dae-Hee
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권3호
    • /
    • pp.422-429
    • /
    • 2008
  • This paper presents compact low frequency ultra-wide band (UWB) sensor design and study of the partial discharge diagnosis by sensing electromagnetic pulse emitted from the partial discharge source with the newly designed UWB sensor. In this study, we designed a new type of compact low frequency UWB sensor based on microstrip antenna technology to detect both the low frequency and high frequency band of the partial discharge signal. Experiments of offline PD testing on medium voltage (22.9kV) underground cable mention the comparative results with the traditional HFCT as a reference sensor in the laboratory. In the series of comparative tests, the calibration signal injection test provided with the conventional IEC 60270 method and high voltage injection testing are included.

UWB 안테나를 이용한 MV급 전력케이블의 부분방전 측정 연구 (PD measuring on MV XLPE Calble by Using UWB Antenna)

  • 양상현;임광진;이용성;박노준;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.267-268
    • /
    • 2008
  • This paper presents compact low frequency ultra-wide band(UWB) sensor design and studying of the partial discharge diagnosis by sensing electromagnetic pulse emitted from the partial discharge source with new designed UWB sensor. In this study, we designed new type of compact low frequency UWB sensor based on microstrip antenna technology to detect both low frequency and high frequency band of partial discharge signal. And experiments of offline PD testing on in medium voltage (22.9kV) underground cable and mention the comparative results with the traditional HFCT as a reference sensor in the laboratory. In the series of comparative test, the calibration signal injection test provided with conventional IEC 60270 method and high voltage injection testing are included.

  • PDF

가스절연개폐장치용 부분방전 감시 시스템을 위한 초광대역 극초단파 신호처리장치 개발 (Development of ultra-high frequency (UHF) ultra-wide bandwidth signal processing unit for UHF partial-discharge monitoring system for gas-insulated switchgears)

  • 최재옥;김영노;이영상;강창원;박기준;구선근;윤진열;구자윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 C
    • /
    • pp.1963-1966
    • /
    • 2004
  • An ultra wide band ultra-high frequency (UHF) signal processing module was designed for on-line UHF partial discharge (PD) monitoring systems for gas-insulated switchgears (GIS). Major advantage of the unit is an improved PD detection sensitivity through minimizing the effect of surrounding interference signals. The detection sensitivity of the unit was <-60 dBm that is sufficient to detect UHF PD signals as low as 1 pC. Precise detection of PD occurred in the GIS, due to internal defects, is possible by using the signal processing unit.

  • PDF

가스절연개폐장치용 부분방전 감시 시스템을 위한 초광대역 극초단파 신호처리장치 개발 (Development of ultra-high frequency (UHF) ultra-wide bandwidth signal processing unit for UHF partial-discharge monitoring system for gas-insulated switchgears)

  • 최재옥;김영노;이영상;강창원;박기준;구선근;윤진열
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.128-131
    • /
    • 2004
  • An ultra wide band ultra-high frequency (UHF) signal processing module was designed for on-line UHF partial discharge (PD) monitoring systems for gas-insulated switchgears (GIS). Major advantage of the unit is an improved PD detection sensitivity through minimizing the effect of surrounding interference signals. The detection sensitivity of the unit was <-60 dBm that is sufficient to detect UHF PD signals as low as 1 pC. Precise detection of PD occurred in the GIS, due to internal defects, is possible by using the signal processing unit.

  • PDF

UV emission characteristics of Ne+$N_2$ gas-mixture discharges in AC Plasma Display Panel

  • Baek, Byung-Jong;Hong, Sang-Min;Choi, Kyung-Cheol
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2002년도 International Meeting on Information Display
    • /
    • pp.586-589
    • /
    • 2002
  • The Ultra Violet(UV) emission characteristics of Neon + Nitrogen gas-mixture discharge was investigated in AC plasma display panel. The firing voltage of Ne+$N_2$ gas-mixture discharge increased with increasing nitrogen concentration. The UV intensity emitted from the gas discharge also increased with increasing nitrogen concentration. The UV efficiency increase with increasing $N_2$ partial pressure at low $N_2$ concentration, and then UV efficiency is saturated at high $N_2$ concentration.

  • PDF

UWB 센서 설계를 통한 고압회전기의 부분방전 진단 연구 (PD Diagnosis On High Voltage Rotating Machines using UWB Sensor)

  • ;임광진;신동훈;김희동;박노준;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 추계학술대회 논문집
    • /
    • pp.197-198
    • /
    • 2007
  • We studied the partial discharge detecting by sensing electromagnetic pulse emitted from the partial discharge source in the stator winding of HV Rotating Machine with UWB sensor. In this study, we designed new type of compact low frequency UWB sensor based on micro-strip technology and made experiments of offline dismantled testing compare with the traditional HFCT as a reference sensor in the laboratory. We investigated internal discharge, surface discharge, corona discharge and non-defected state normal stator on pre-made stator winding by using UWB patch sensor.

  • PDF

UHF 부분방전 감시 장치를 위한 초광대역 검출장치 개발 및 특성조사 (Development and characterization of a ultra-wide bandwidth video detector for the UHF partial discharge monitoring system)

  • 박기준;구선근;윤진열
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1649-1651
    • /
    • 2002
  • Ultra-wide bandwidth (UWB) detection method has been widely used as a front end detection scheme for the ultra-high frequency (UHF) partial discharge (PD) monitoring systems. A broad-band video detector module was developed and characterized for the UHF UWB PD detection systems. The useable bandwidth of the module is more than 2 GHz and it is optimized for 50-ohm systems. The detection sensitivity and dynamic range of the module were characterized by using a known ns-width RF pulses of GHz range. The dynamic range is more than 6-decades and the module can detect pulsed RF signals down to 1 nW. The detector module can eliminate expensive equipment such as high speed oscilloscopes and radio frequency (RF) spectrum analyzers. Therefore, it enables one to use slow speed data acquisition systems for the PD monitoring at the UHF range. The detector module was used to detect real PDs of about <3 pC. The module converts the UWB PD signals into a low-bandwidth video signal with a high signal-to-noise ratio.

  • PDF