• 제목/요약/키워드: ultra sound

검색결과 92건 처리시간 0.022초

Thermal stabilityof fluorine doped silicon oxide films

  • Lee, Seog-Heong;Yoo, Jae-Yoon;Park, Jong-Wan
    • Journal of Korean Vacuum Science & Technology
    • /
    • 제2권1호
    • /
    • pp.25-31
    • /
    • 1998
  • The reliability of fluorine doped silicon oxide (SiOF) films for intermetal dielectrics in multilevel interconnections of ultra-large scale integrated circuits (ULSIs) is investigated. SiOF films were deposited by electron cyclotron resonance plasma-enhanced chemical vapor deposition (ECRPECVD) using H-free source gases, i.e., SiF4 and O2. The effect of post plasma treatment on the moisture absorption and dielectric properties of SiOF films was carried out I terms of air exposure time, The reliability test of Cu/TiN/SiOF/Fi specimen was carried out in terms of temperature by rapid thermal annealing (RTA) in N2 ambient. After O2 plasma treatment,, no appreciable peak directly related to moisture absorption was detected. The capacitance-voltage (C-V) characteristics of the O2 plasma treated SiOF film showed that the film remained to hold the sound dielectric properties even after boiling treatment. The Cu/TiN/SiOF/Si system was found to be reliable up to $600^{\circ}C$.

연마제 재활용을 위한 분급장치 개발에 관한 연구 (A Study on the Development of Classifier for Recycling of Abrasive)

  • 김문기
    • 반도체디스플레이기술학회지
    • /
    • 제16권3호
    • /
    • pp.20-24
    • /
    • 2017
  • For process improvement and cutting down on expenses in solar cell industry, it is necessary to improve recycling process of wafer manufacturing. In this research, a study is introduced to develop classifier which is for recycling of abrasive. First of all, recycling process of wafer manufacturing is analyzed. And then, 3 steps of experiments such as oil removal, impurities removal and classification were executed. For the classification of slurry, a classifier is designed and manufactured. From experiments, it is verified that ultra sound vibration and flux are very important factors for classification. By experiencing the recycling processes and making devices, the technique can be initiated industry if needed such as decreasing waste and cutting down on expenses.

  • PDF

초고선명 방송을 위한 오디오 포맷 및 부호화 기법 (Audio Signal Format and Coding Method for Ultra High Definition Television (UHDTV))

  • 서정일;강경옥
    • 한국음향학회지
    • /
    • 제28권7호
    • /
    • pp.580-588
    • /
    • 2009
  • 본 논문에서는 초고선명 방송 (UHDTV)에서의 고품질 실감 오디오를 재현하기 위한 오디오 신호규격 및 멀티채널 오디오 재생시스템 형상, 멀티채널 오디오 부호화 기법에 대한 기술개발 동향, 표준화 현황, 문제점에 대해서 살펴보고 국내의 방송 및 통신 환경에 적절한 해결 방안을 제시한다.

마모 상대재 변화에 따른 TiN 극박막의 마찰 및 마모거동 (Friction and Wear Behavior of Ultra-Thin TiN Film during Sliding Wear against Alumina and Hardened Steel)

  • 송명훈;이재갑;김용석
    • 한국재료학회지
    • /
    • 제10권1호
    • /
    • pp.62-68
    • /
    • 2000
  • Reactive DC magnetron sputtering 법으로 AISI 304 스테인레스강 기판 위에 TiN 극박막을 50nm∼700nm 두께로 증착한 후, 경화된 AISI 52100 강과 알루미나를 마모 상대재로 하여 박막의 미끄럼마모 시험을 상온 대기 중에서 행하고, 마모 상대재에 따른 TiN 극박막의 마찰과 마모 거동을 연구하였다. AISI 52100 강구를 마모 상대재로 한 경우, TiN 박막은 200g 이하의 마모 하중과 0.035m/sec의 낮은 미끄럼 속도 조건에서 500nm 내외의 극박으로도 마찰계수가 0.1 내외로 유지되는 우수한 내마모성을 보였다. 이같이 우수한 내마모성은 AISI 52100 강으로부터 천이된 Fe가 산화되어 TiN 박막 표면에 Fe 산화층을 형성한 때문으로 설명되었다. 그러나, 마모 상대재를 알루미나 볼로 한 경우에는 TiN 박막 위에 산화층이 형성되지 않고, 마모가 거의 되지 않는 알루미나 볼과 박막층 사이에 국부적 응력집중 등이 발생하여 시험된 전 조건 하에서 박막층의 박리 현상이 관찰되었고 높은 마찰계수가 측정되었다. 또한 기판의 평균 표면조도, Ra가 박막의 두께와 유사할 때 마찰계수가 급격히 상승하는 현상이 관찰되었다.

  • PDF

견갑골 내측 상부의 발통점에 체외충격파와 초음파 적용시 통증과 피부두께, 근력변화에 미치는 영향 (The Effects of ESWT and US on Muscle Power, Pain and Muscle Tension at Trigger Point of the Scapular Inter Angle)

  • 이승협;피어라;정하늬;이호석;주다솔;이승희;최민희;최현지;홍영인;김지은;한상완
    • 대한임상전기생리학회지
    • /
    • 제7권1호
    • /
    • pp.29-34
    • /
    • 2009
  • Purpose : This study aims to investigate into the change in muscle power, pain and muscle tension upon application of extracorporeal shock wave therapy (ESWT) and ultrasound (US) at trigger point (TrP) of the Scapular inter angle. Methods : In total of 24 human subjects that experience pain upon stimulation at the scapular inter angle were recruited. They were divided into three groups: control, ESWT and US group. Each group was subjected to appropriate stimulation three times per week for four weeks except the control group which had no restrictions in lifestyle. The ESWT group was subjected to Extracorporeal Shock Wave Therapy with a 2 $cm^2$ head, 20 times at speed of application of 60 pulses/min and depth of intrusion of 25 mm Whereas the US group was subject to Ultra sound therapy with 1$cm^2$ head, 1 MHz in frequency, 1.5 W/$cm^2$ of strength with five minutes of continuous application. Measurements were performed immediately prior to and at the end of the experiment. Results : There was no statistical significance in the change in muscle tension and muscle power as well as the difference between both groups before and after the experiment. VAS and VRS, all of which indicates changes in pain level, had statistically significant differences between them in pretest posttest comparisons. However, ESWT was superior to US in terms of decreasing muscle tension and pain while increasing muscle power. Conclusion : This study has made it evident that ESWT is far more reasonable to apply to TrP.

채널 기반에서 객체 기반의 오디오 콘텐츠로의 변환을 위한 비균등 선형 마이크로폰 어레이 기반의 음원분리 방법 (Non-uniform Linear Microphone Array Based Source Separation for Conversion from Channel-based to Object-based Audio Content)

  • 전찬준;김홍국
    • 방송공학회논문지
    • /
    • 제21권2호
    • /
    • pp.169-179
    • /
    • 2016
  • 오늘날 UHDTV (Ultra-High-Definition TV) 시대에 사용될 멀티미디어 부호화기로 MPEG-H에 대한 표준화가 진행되고 있다. 향후 방송용 오디오 콘텐츠는 채널 기반 오디오 콘텐츠에서 진화하여 객체 기반 오디오 콘텐츠까지도 포함하게 될 예정이다. 이에 따라, 채널 기반 오디오 콘텐츠의 객체 기반 오디오 콘텐츠로의 유기적인 변환이 필요한 실정이다. 본 논문에서는 이러한 유기적인 변환을 실현 가능하게 할 수 있는 비균등 선형 마이크로폰 어레이 기반의 음원분리 기법을 제안한다. 제안된 기법은 주어진 어레이 배치에 따라 채널간의 시간차를 분석하고, 분석된 시간차에 따라 주파수별로 특정 방위각에 위치한 입력 오디오 신호의 spectral magnitude를 예측한다. 이후, azimuth와 width 파라메타를 조정함으로써 객체 오디오 생성을 위한 음원을 분리한다. 제안된 음원분리 기법의 성능을 평가하기 위하여 객관적 음원분리 지표 및 분리정확도를 측정하였고, 최소 분산 무손실 응답 빔형성기와 독립 성분 분석 기법 등 기존 음원분리 기법과의 그 성능을 비교하였다. 비교 결과, 제안된 기법이 기존 음원분리 기법들에 비하여 우수한 음원분리 성능을 보이는 것을 알 수 있었다.

B-mode ultrasound images of the carotid artery wall: correlation of ultrasound with histological measurements

  • Gamble G.;Beaumont B.;Smith H.;Zorn J.;Sanders G.;Merrilees M.;MacMahon S.;Sharpe N.
    • 대한예방의학회:학술대회논문집
    • /
    • 대한예방의학회 1994년도 교수 연수회(역학)
    • /
    • pp.169-179
    • /
    • 1994
  • B-mode ultrasound is being used to assess carotid atherosclerosis in epidemiological studies and clinical trials. Recently the interpretation of measurements made from ultrasound images has been questioned. This study examines the anatomical correlates of B-mode ultrasound of carotid arteries in vitro and in situ in cadavers. Twenty-seven segments of human carotid artery were collected at autopsy. pressure perfusion fixed in buffered 2.5% gluteraldehyde and 4% paraformaldehyde and imaged using an ATL UM-8 (10 MHz single crystal mechanical probe). Each artery was then frozen, sectioned and stained with van Gieson or elastin van Gieson. The thickness of the intima. media and adventitia were measured 'to an accuracy of 0.01 mm from histological sections using a calibrated eye graticule on a light microscope. Shrinkage artifact induced by histological preparation was determined to be 7.8%. Digitised ultra sound images of the artery wall were analysed off-line. The distance from the leading edge of the first interface ($LE_{1}$) to the leading edge of the second interface ($LE_2$) was measured using a dedicated programme. $LE_{1}$-$LE_{2}$ measurements were correlated against histological measurements corrected for shrinkage. Mean values for the far wall were: ultra sound $LE_{1}$-$LE_{2}$ (0.97 mm, S.D. 0.26), total wall thickness (1.05 mm, S.D. 0.37), adventitia (0.35 mm, S.D. 0.16), media (0.61 mm, S.D. 0.18). intima (0.09 mm, S.D. 0.13). Ultrasound measurements corresponded best with total wall thickness, rather than elastin or the intima-media complex. Excision of part of the intima plus media or removal of the adventitia resulted in a corresponding decrease in the $LE_{1}$-$LE_{2}$ distance of the B-mode image. Furthermore. increased wall thickness due to intimal atherosclerotic thickening correlated well with $LE_{1}$-$LE_{2}$ distance of the B-mode images. B-mode images obtained from the carotid arteries in situ in four cadavers also corresponded best with total wall thickness measured from histological sections and not with the thickness of the intima plus media. In conclusion, the $LE_{1}$-$LE_{2}$ distance measured on B-mode images of the carotid artery best represents total wall thickness of intima plus media plus adventitia and not intima plus media alone.

  • PDF

저가형 PSD센서를 이용한 홈서비스 로봇의 Map building용 센서 제어시스템 (A sensor controller for map building of home service robot using low cost PSD sensor)

  • 현웅근;이창환
    • 한국정보통신학회논문지
    • /
    • 제10권10호
    • /
    • pp.1897-1904
    • /
    • 2006
  • 가사도우미 로봇과 같은 서비스 로봇은 가사구성물이 내제된 가정 내 가사 구성물 환경을 인식해야한다. 기존에는 홈서비스 로봇 등은 CCD, 초음파 등의 센서로 가정 내 구성물 및 실내 지형을 인식하였다. 실내지형 지도를 작성 할 경우 가사 구성물에는 헝겊 등이 있는바, 음파 등을 흡수하여 정확한 지형 지도가 만들어지지 못한다. 또한 CCD 카메라를 쓸 경우 pixel에 따라 거리 측정 정도가 달라지는 문제가 발생하고 가격이 고가이다. 본 논문은 이동로봇을 위한 위치 및 물체인식용 지능형 센서 제어 시스템에 대해 기술한다. 개발된 센서제어시스템은 저가의 광 PSD(Position sensitive detector)를 사용하였다. PSD센서의 스위칭 노이즈 및 광 산란에 의한 잡음을 효과적으로 제거하기 위해 로봇의 주행 중 센서 스캔 시 간 등을 고려하여 heuristic software filter를 제안하였다. 또한 개발된 시스템은 초음파 센서에 의한 지형작성 비교와 본 논문에서 개발한 시스템을 비교하였으며, 복잡한 실내지 형을 대상으로 실험 지형지도 작성 실험을 통해 우수성을 입증하였다.

초음파를 이용한 턱관절질환의 진단과 초음파 가이드의 활용 (Diagnostic Application of Temporomandibular Joint Disorder and Ultra Sound Guided Oral &Maxillofacial application)

  • 성태환;박정현;김선종
    • 대한치과의사협회지
    • /
    • 제55권11호
    • /
    • pp.789-799
    • /
    • 2017
  • Ultrasound images are noninvasive, can be observed in real time, have no radiation exposure, do not cause pain, and are not restricted in use depending on the patient's prosthetic implant or medical condition. Since the use of ultrasound in the dental field was first applied for tooth preparation in 1957, the use of diagnostic ultrasound for the first time in 1963 has been reported. Currently, it is used in the diagnosis of soft tissue lesions such as malignant tumor or salivary gland disease, fine needle aspiration test, temporomandibular joint disease, lymph node metastasis, measurement of muscle thickness and inflammatory diseases, differentiation of periapical cyst and granulation tissue, measurement of periodontal tissue thickness. The ultrasound image can be visualized in real time. The clinician can explain the structure to the patient while consulting the patient and consult the patient. When injecting the drug into a specific site or aspirating a specific site or substance, So that it can be confirmed and practiced. Recently, ultrasonic equipment specialized in the dental field has been developed and marketed, and it is expected that the use of ultrasonic waves will become active in the dentistry. In the future, development of popular equipment with size and frequency suitable for dental diagnosis and various researches on maxillofacial ultrasonic anatomy. If clinical studies are continuously carried out to demonstrate efficacy, ultrasound is expected to aid in accurate diagnosis and treatment throughout the dentistry.

  • PDF

Effect of ages and season temperatures on bi-surface shear behavior of HESUHPC-NSC composite

  • Yang Zhang;Yanping Zhu;Pengfei Ma;Shuilong He;Xudong Shao
    • Advances in concrete construction
    • /
    • 제15권6호
    • /
    • pp.359-376
    • /
    • 2023
  • Ultra-high-performance concrete (UHPC) has become an attractive cast-in-place repairing material for existing engineering structures. The present study aims to investigate age-dependent high-early-strength UHPC (HESUHPC) material properties (i.e., compressive strength, elastic modulus, flexural strength, and tensile strength) as well as interfacial shear properties of HESUHPC-normal strength concrete (NSC) composites cured at different season temperatures (i.e., summer, autumn, and winter). The typical temperatures were kept for at least seven days in different seasons from weather forecasting to guarantee an approximately consistent curing and testing condition (i.e., temperature and relative humidity) for specimens at different ages. The HESUHPC material properties are tested through standardized testing methods, and the interfacial bond performance is tested through a bi-surface shear testing method. The test results quantify the positive development of HESUHPC material properties at the early age, and the increasing amplitude decreases from summer to winter. Three-day mechanical properties in winter (with the lowest curing temperature) still gain more than 60% of the 28-day mechanical properties, and the impact of season temperatures becomes small at the later age. The HESUHPC shrinkage mainly occurs at the early age, and the final shrinkage value is not significant. The HESUHPC-NSC interface exhibits sound shear performance, the interface in most specimens does not fail, and most interfacial shear strengths are higher than the NSC-NSC composite. The HESUHPC-NSC composites at the shear failure do not exhibit a large relative slip and present a significant brittleness at the failure. The typical failures are characterized by thin-layer NSC debonding near the interface, and NSC pure shear failure. Two load-slip development patterns, and two types of main crack location are identified for the HESUHPC-NSC composites tested in different ages and seasons. In addition, shear capacity of the HESUHPC-NSC composite develops rapidly at the early age, and the increasing amplitude decreases as the season temperature decreases. This study will promote the HESUHPC application in practical engineering as a cast-in-place repairing material subjected to different natural environments.