• Title/Summary/Keyword: ultra performance liquid chromatography (UPLC)

Search Result 93, Processing Time 0.03 seconds

Rapid separation and identification of 31 major saponins in Shizhu ginseng by ultra-high performance liquid chromatography-electron spray ionization-MS/MS

  • Sun, Ting-Ting;Liang, Xin-Lei;Zhu, He-Yun;Peng, Xu-Ling;Guo, Xing-Jie;Zhao, Long-Shan
    • Journal of Ginseng Research
    • /
    • v.40 no.3
    • /
    • pp.220-228
    • /
    • 2016
  • Background: Among the various ginseng strains, Shizhu ginseng is endemic to China, mainly distributed in Kuandian Manchu Autonomous County (Liaoning Province, China); however, not much is known about the compounds (especially saponins) in Shizhu ginseng. Methods: A rapid, sensitive, and reliable ultra-high performance liquid chromatography coupled with MS/MS (UHPLC-MS/MS) method was developed to separate and identify saponins in Shizhu ginseng. Results: The separation was carried out on a Waters ACQUITY UPLC BEH $C_{18}$ column ($100mm{\times}2.1mm$, $1.7{\mu}m$) with acetonitrile and 0.1% formic acid aqueous solution as the mobile phase under a gradient elution at $40^{\circ}C$. The detection was performed on a Micromass Quattro Micro API mass spectrometer equipped with electrospray ionization source in both positive and negative modes. Under the optimized conditions, a total of 31 saponins were identified or tentatively characterized by comparing retention time and MS data with related literatures and reference substances. Conclusion: The developed UHPLC-MS/MS method was suitable for identifying and characterizing the chemical constituents in Shizhu ginseng, which provided a helpful chemical basis for further research on Shizhu ginseng.

Qualitative and quantitative analysis of the saponins in Panax notoginseng leaves using ultra-performance liquid chromatography coupled with time-of-flight tandem mass spectrometry and high performance liquid chromatography coupled with UV detector

  • Liu, Fang;Ma, Ni;He, Chengwei;Hu, Yuanjia;Li, Peng;Chen, Meiwan;Su, Huanxing;Wan, Jian-Bo
    • Journal of Ginseng Research
    • /
    • v.42 no.2
    • /
    • pp.149-157
    • /
    • 2018
  • Background: Panax notoginseng leaves (PNL) exhibit extensive activities, but few analytical methods have been established to exclusively determine the dammarane triterpene saponins in PNL. Methods: Ultra-performance liquid chromatography coupled with time-of-flight mass spectrometry (UPLC/Q-TOF MS) and HPLC-UV methods were developed for the qualitative and quantitative analysis of ginsenosides in PNL, respectively. Results: Extraction conditions, including solvents and extraction methods, were optimized, which showed that ginsenosides Rc and Rb3, the main components of PNL, are transformed to notoginsenosides Fe and Fd, respectively, in the presence of water, by removing a glucose residue from position C-3 via possible enzymatic hydrolysis. A total of 57 saponins were identified in the methanolic extract of PNL by UPLC/Q-TOF MS. Among them, 19 components were unambiguously characterized by their reference substances. Additionally, seven saponins of PNL-ginsenosides Rb1, Rc, Rb2, and Rb3, and notoginsenosides Fc, Fe, and Fd-were quantified using the HPLC-UV method after extraction with methanol. The separation of analytes, particularly the separation of notoginsenoside Fc and ginsenoside Rc, was achieved on a Zorbax ODS C8 column at a temperature of $35^{\circ}C$. This developed HPLC-UV method provides an adequate linearity ($r^2$ > 0.999), repeatability (relative standard deviation, RSD < 2.98%), and inter- and intraday variations (RSD < 4.40%) with recovery (98.7-106.1%) of seven saponins concerned. This validated method was also conducted to determine seven components in 10 batches of PNL. Conclusion: These findings are beneficial to the quality control of PNL and its relevant products.

Quantitative Analysis of the Twenty Marker Components in Gwakhyangjeonggi-san using Ultra-Performance Liquid Chromatography with Mass Spectrometer (LC-MS/MS를 이용한 곽향정기산(藿香正氣散) 추출물 중 20종 성분의 함량분석)

  • Seo, Chang-Seob;Shin, Hyeun-Kyoo
    • Korean Journal of Pharmacognosy
    • /
    • v.45 no.2
    • /
    • pp.113-120
    • /
    • 2014
  • Generally, Gwakhyangjeonggi-san has been used for treatment of diarrhea-predominant irritable bowel syndrome. In this study, an ultra-performance liquid chromatography-electrospray ionization-mass spectrometer method was established for the simultaneous quantification of marker compounds 1-20 in Gwakhyangjeonggi-san water extract. All analytes were separated by gradient elution using two mobile phases on a UPLC BEH $C_{18}$ ($100{\times}2.1mm$, $1.7{\mu}m$) column and maintained at $45^{\circ}C$. The injection volume was $2.0{\mu}L$ and the flow rate was 0.3 mL/min with detection at mass spectrometer. Regression equations of the compounds 1-20 were acquired with $r^2$ values ${\geq}0.9950$. The values of limit of detection and quantification of all analytes were 0.01-2.79 ng/mL and 0.03-8.37 ng/mL, respectively. The amounts of the compounds 1-20 in Gwakhyangjeonggi-san water extract were not detected $-3,236.67{\mu}g/g$. The established LC-MS/MS methods will be valuable to improve quality control of traditional herbal formula, Gwakhyangjeonggi-san.

Quantitative Analysis of Hyangsayukgunja-Tang Using an Ultra-Performance Liquid Chromatography Coupled to Electrospray Ionization Tandem Mass Spectrometry (LC-MS/MS를 이용한 향사육군자탕의 주요성분의 함량분석)

  • Seo, Chang-Seob;Shin, Hyeun-Kyoo
    • Korean Journal of Pharmacognosy
    • /
    • v.46 no.4
    • /
    • pp.352-364
    • /
    • 2015
  • The aim of this study was to quantitatively analyze for quality assessment of eighteen marker compounds, including homogentisic acid, 3,4-dihydroxybenzaldehyde, spinosin, liquiritin, hesperidin, ginsenoside Rg1, liquiritigenin, ginsenoside Rb1, glycyrrhizin, 6-gingerol, atractylenolide III, honokiol, costunolide, dehydrocostuslactone, atractylenolide II, nootkatone, magnolol, and atractylenolide I, in Hyangsayukgunja-tang using an ultra-performance liquid chromatography-electrospray ionization-mass spectrometer. The column for separation of eighteen marker components were used a UPLC BEH $C_{18}$ analytical column ($2.1{\times}100mm$, $1.7{\mu}$) and kept at $45^{\circ}C$ by gradient elution with 0.1% (v/v) formic acid in water and acetonitrile as mobile phase. The flow rate and injection volume were 0.3 mL/min and $2.0{\mu}l$, respectively. The correlation coefficient of all marker compounds was ${\geq}0.9914$, which means good linearity, within the test ranges. The limits of detection and quantification values of the all analytes were in the ranges 0.04-1.11 and 0.13-3.33 ng/mL, respectively. As a result, five compounds, homogentisic acid, 3,4-dihydroxybenzaldehyde, spinosin, liquiritigenin, and atractylenolide I, in this sample were not detected and the amounts of the 13 compounds except for the 5 compounds were $8.10-6736.37{\mu}g/g$ in Hyangsayukgunja-tang extract.

Quantitative Analysis of the Seventeen Marker Components in Dangguisu-san Using Ultra-performance Liquid Chromatography Coupled to Electrospray Ionization Tandem Mass Spectrometry (LC-MS/MS를 이용한 당귀수산 추출물 중 17종 성분의 함량분석)

  • Seo, Chang-Seob;Shin, Hyeun-Kyoo
    • YAKHAK HOEJI
    • /
    • v.58 no.3
    • /
    • pp.158-164
    • /
    • 2014
  • Dangguisu-san is a well-known traditional Korean herbal medicine prescription and has been widely used to treat ecchymosis, blood stagnation, and pain resulting from physical shock in Korea. In this study, an ultra-performance liquid chromatography-electrospray ionization-mass spectrometer method was established for the simultaneous determination of the 17 biomarker components in Dangguisu-san. All analytes were separated on an UPLC BEH $C_{18}$ ($100{\times}2.1$ mm, $1.7{\mu}m$) column and maintained at $45^{\circ}C$. The mobile phase consisted of two solvent systems, 0.1% (v/v) formic acid in water (A) and acetonitrile (B) by gradient flow. The injection volume was $2.0{\mu}l$ and the flow rate was 0.3 ml/min with detection at mass spectrometer. Calibration curves of the 17 biomarker components were acquired with $r^2$ values ${\geq}0.9951$. The values of limit of detection and quantification of all analytes were 0.02~6.32 ng/ml and 0.05~18.95 ng/ml, respectively. The amounts of the 17 components in Dangguisu-san sample were $3.17{\sim}13,224.50{\mu}g/g$.

Experimental studies of homogeneity and stability honeybee venom using ultra-high performance liquid chromatography (주사제 사용을 위한 봉독의 균질성 및 안정성 평가)

  • Han, Sang Mi;Kim, Se Gun;Hong, In Phyo;Woo, Soon Ok;Jang, Hye Ri;Lee, Kyung Woo
    • Korean Journal of Veterinary Service
    • /
    • v.39 no.2
    • /
    • pp.81-86
    • /
    • 2016
  • Honeybee venom (BV) from Apis mellifera L. has been used as natural antimicrobial compounds in pigs, cows, dairy cattle and chicken farms in Korea. The purpose of this study was conducted to confirm homogeneity and stability of BV dissolved with distilled water or saline solution. Melittin was analyzed with ultra-high performance liquid chromatography (UPLC) for BV to secure the validation of analysis. BV at concentration of 1 mg/mL was dissolved with distilled water or saline solution at room temperature. Homogeneity of BV dissolved with distilled water or saline solution at upper, milddle, and lower layers all satisfied the accuracy and precision criteria. Stability of BV dissolved with distilled water or saline solution for 7 days all satisfied the criterion both light and dark storage condition. BV has satisfied with homogeneity and stability in distilled water or saline solution at room temperature under light or dark condition. The results of this study suggest that BV has a possibility as the substitute of natural antimicrobial agents for the animal drugs and feed additives.

Quantitative Analysis of the Eleven Marker Components in Traditional Korean Formula, Jakyakgamcho-Tang Decoction Using an Ultra-Performance Liquid Chromatography Coupled to Electrospray Ionization Tandem Mass Spectrometry (UPLC-MS/MS를 이용한 작약감초탕 물 추출물 중 11종 성분의 함량분석)

  • Seo, Chang-Seob;Shin, Hyeun-Kyoo
    • YAKHAK HOEJI
    • /
    • v.60 no.2
    • /
    • pp.64-72
    • /
    • 2016
  • Jakyakgamcho-tang is a well-known traditional herbal medicine and has been used for the treatment of mainly pains in oriental medicine. In this study, analytical method for the quantitative determination of the eleven marker components, gallic acid (1), oxypaeoniflorin (2), paeoniflorin (3), albiflorin (4), liquiritin (5), isoliquiritin (6), ononin (7), liquiritigenin (8), benzoylpaeoniflorin (9), paeonol (10), and glycyrrhizin (11) in Jakyakgamcho-tang decoction was performed using an ultra-performance liquid chromatography-electrospray ionization-mass spectrometer. The analytical column for separation of the compounds 1~11 was used an UPLC BEH $C_{18}$ ($100{\times}2.1mm$, $1.7{\mu}m$) column and column oven temperature was maintained at $45^{\circ}C$. The mobile phase consisted of 0.1% (v/v) aqueous formic acid (A) and acetonitrile (B) by gradient elution. The flow rate was 0.3 ml/min and injection volume was $2.0{\mu}l$. Correlation coefficient in the calibration curves of the compounds 1~11 were showed a good linearity with more than 0.99. The limit of detection and limit of quantification values of the compounds 1~13 were detected in the ranges 0.06~18.43 ng/ml and 0.18~58.29 ng/ml, respectively. Among the compounds 1~11, the compounds 10 were not detected in this sample, while the ten compounds, 1~9 and 11, were detected $44.05{\sim}19,289.05{\mu}g/g$ in Jakyakgamcho-tang extract.

Determination of Free Amino Acids in Isatidis Radix By HILIC-UPLC-MS/MS

  • Pan, Yilin;Li, Jin;Li, Xiang;Chen, Jianwei;Bai, Ganggang
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.1
    • /
    • pp.197-203
    • /
    • 2014
  • A rapid, accurate and precise method for the determination of 22 amino acids in Isatidis Radix by Hydrophilic Interaction Ultra-High-Performance Liquid Chromatography Coupled with Triple-Quadrupole Mass Spectrometry (HILIC-UPLC-MS/MS) was established. Chromatographic separation was carried out on a Acquity UPLC BEH Amide column ($2.1mm{\times}100mm$, $1.7{\mu}m$) with gradient elution of acetonitrile (containing 0.05% formic acid and 2 mM ammonium formate) and water (containing 0.15% formic acid and 10 mM ammonium formate) at a flow rate of 0.4 mL/min; Waters Xevo$^{TM}$ TQ worked in multiple reaction monitoring mode. All components were separated in 17 min. All calibration curves were linear ($R^2$ > 0.991) over the tested ranges. The limits of detection (LOD) and limits of quantitation (LOQ) for these compounds were 0.21-79.55 and 0.72-294.23 ng/mL, respectively. The average recoveries were in the range of 93.75-104.16% with RSD value less than 6.56%. Therefore, this method could be an alternative assay for the determination of 22 amino acids in Isatidis Radix due to its rapidness, sensitivity, less sample and solvent consumption.

Comparison of medical history based diagnosis and urine test using ultra-performance liquid chromatography-tandem mass spectrometry in drug overdose (약물중독 환자에서 병력 기반 진단과 요 고성능 액체색층분석 탄뎀 질량 분광분석의 비교)

  • Lee, Ja-Young;Cha, Kyungman;Jeong, Won Jung;Kim, Hyung Min;So, Byung Hak
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.20 no.1
    • /
    • pp.1-7
    • /
    • 2022
  • Purpose: In patients with acute drug overdose, identification of drugs ingested is crucial to make a precise diagnosis. In most cases, the diagnoses are made on the medical history and physical examination findings. This study was undertaken to determine the concordance of diagnosis made on the basis of patient history by comparing it with urine toxicology analysis. Methods: This was a retrospective study of drug intoxicated patients over 18 years old who presented to the emergency center from 2017 to 2019. Specimens from urine were tested using ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-TMS). The test results were compared with information obtained from patients. Diagnostic concordances for drug detection in intoxicated patients were calculated. Logistic regression analysis was used to examine the association between clinical characteristics and diagnostic discrepancy. Results: Totally, 370 patients were included in the analysis. Overall, 66 types of drugs were detected by UPLC-TMS. The drugs detected most frequently were zolpidem (104, 27.8%), citalopram (70, 18.7%), and paracetamol (66, 17.6%). The mean diagnostic concordance of patients was 52.7%. There were statistically significant diagnostic discrepancies in patients with underlying depression and patients intoxicated with multiple types of drugs. Conclusion: In ED patients with acute drug overdose, the diagnoses made on history alone were often inaccurate. It is essential to perform urine toxicology tests such as UPLC-TMS as a confirmatory instrument to improve accuracy in evaluating patients with drug intoxication.

Detection of phenobarbital adulteration in dietary supplements: simultaneous analysis of 16 sedative-hypnotics and sleep-inducers by ultra-high-performance liquid chromatography with UV detection (UPLC-UV) and quadruple Orbitrap mass spectrometry (Q-Orbitrap-MS)

  • Lee, Ji Hyun;Choi, Ji Yeon;Park, Hanna;Min, Ah Young;Kim, Nam Sook;Park, Seong Soo;Park, Sung-Kwan;Kang, Ho-il
    • Analytical Science and Technology
    • /
    • v.32 no.1
    • /
    • pp.24-34
    • /
    • 2019
  • The safety of food is occasionally questionable, as there have been some reports of products contaminated with illegal adulterants. In this study, the presence of 16 sedative-hypnotics and sleep inducers in dietary supplements was determined by ultra-high-performance liquid chromatography with UV detection (UPLC-UV) and quadruple Orbitrap mass spectrometry (Q-Orbitrap-MS). The UPLC method was validated, providing a linearity (R2) of more than 0.999, and LODs and LOQs that ranged from 0.2 to 0.5 and 0.6 to $1.5{\mu}g\;mL^{-1}$, respectively. The repeatabilities were 0.2-8.4 % (intra-day) and 0.3-4.5 % (inter-day), and the accuracies were 89.0-117.0 % (intra-day) and 87.8-111.9 % (inter-day). The mean recoveries of the spiked samples ranged from 98.7 to 107.3 %. The relative standard deviation (%RSD) of the stability was less than 2.4 %. Using the developed method, one sedative-hypnotic compound, phenobarbital, was detected in one of the nineteen samples tested. In addition, the major characteristic fragment ions of each target compound were confirmed using Q-Orbitrap-MS for higher accuracy. Monitoring the presence of these 16 sedative-hypnotics and sleep inducers in dietary supplements should be pursued in the interest of human health, and the results of this study confirmed that the developed method has value for this application.