• 제목/요약/키워드: ultra noises

검색결과 16건 처리시간 0.023초

전자파 잡음을 이용한 전기설비 불량 검출장치 개발 (Development of the equipment for detecting the poor power facilities by receiving electric noises)

  • 이복규;강성철
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.1356-1359
    • /
    • 1997
  • There are various methods to detect the faulty electric facilities(esp, insulator) indirectly on power distribution lines at a certain distance apart. This paper describes the proto type equipment to detect a faulty insulator by receiving a electric discharge noises, which are generated with a periodicity of 120Hz.

  • PDF

지중배전케이블의 PD 검출용 필터 시험 연구 (Filter Test for Partial Discharge Detection of Underground Distribution Cables)

  • 이용성;김정윤;이관우;최용성;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.215-216
    • /
    • 2005
  • To decrease and remove of much noises that is detected in PD (partial discharge) measuring test. we forced on detection of those. We made W-LC filter for measuring PD. which adapted that to field test. We tested after design laboratory circumstances like field line. and then the phase change properties of detected signal in UHF sensor were measured by Lemke Probe and oscilloscope (TDS-3054. Tektronix). Eventually we checked decrement of noises from experimental result. Also from experimental result at the joint box of 22.9[kV] distribution line. we obtained reasonable data which enable noises to decrease. Hereafter those results will be adapted at ultra-high voltage for trouble prevention and on-line cable watch. diagnosis of those.

  • PDF

XLPE 전력케이블의 부분방전 검출을 위한 HPF 적용 시험 (HPF Application Test for PD Detection of XLPE Power Cable)

  • 김정윤;양종경;박노준;최용성;박대희;이용성
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권4호
    • /
    • pp.161-165
    • /
    • 2006
  • In this paper, we developed HPF (high pass filter) consists of lumped LC components to decrease the noises that are detected in PD (partial discharge) measuring test, and adapted it to field test. We tested it under laboratory circumstances like the fields, and measured the phase change properties of detected signal in UHF sensor with Lemke Probe and oscilloscope (TDS-3054, Tektronix). As a result, we obtained available data showing the decrease of noises in the experiments with the developed HPF from the joint box of 22.9kV distribution line. The result can be adapted to prevent the degeneration of the XLPE power cable, and to observe and diagnosis the underground power transmission cable at the ultra-high voltage.

나노 스테이지에 대한 슬라이딩-모드 제어 기반의 강인 최적 제어기 설계 (Design of Robust Optimal Controller for Nano Stage using Sliding-mode Control)

  • 최인성;최승옥;유관호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.101-103
    • /
    • 2007
  • In this paper. we design a robust optimal controller for ultra-precision positioning system. Generally, it is hard to control the nanometric scale positioning system because of the parameter uncertainties and external disturbances. To solve this problem. we suggest a control algorithm based on the modified sliding-mode control and the LQ control in an augmented system. The augmented system is composed of additional state variables: state estimates and control input in the nominal system. Through comparison with LQ optimal control, it is verified that the proposed control algorithm is more robust to the unexpected parameter variations and external noises.

  • PDF

High-frame-rate Video Denoising for Ultra-low Illumination

  • Tan, Xin;Liu, Yu;Zhang, Zheng;Zhang, Maojun
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제8권11호
    • /
    • pp.4170-4188
    • /
    • 2014
  • In this study, we present a denoising algorithm for high-frame-rate videos in an ultra-low illumination environment on the basis of Kalman filtering model and a new motion segmentation scheme. The Kalman filter removes temporal noise from signals by propagating error covariance statistics. Regarded as the process noise for imaging, motion is important in Kalman filtering. We propose a new motion estimation scheme that is suitable for serious noise. This scheme employs the small motion vector characteristic of high-frame-rate videos. Small changing patches are intentionally neglected because distinguishing details from large-scale noise is difficult and unimportant. Finally, a spatial bilateral filter is used to improve denoising capability in the motion area. Experiments are performed on videos with both synthetic and real noises. Results show that the proposed algorithm outperforms other state-of-the-art methods in both peak signal-to-noise ratio objective evaluation and visual quality.

GIS내부의 부분방전신호 감도개선 및 주파수변환기법에 의한 GIS UHF Sensor 모듈의 외부노이즈차폐기법에 관한 연구 (A Study of the Method for External Noise Shielding using the GIS UHF Sensor Module Applied to the Partial Discharge Signal Sensitivity and Method of Frequency Transforming in the Internal GIS)

  • 이승민
    • 전기학회논문지
    • /
    • 제59권4호
    • /
    • pp.728-732
    • /
    • 2010
  • GIS(Gas insulated switching gear) is power equipment with excellent dielectric strength and is economy merit in high confidence and stability. Recently, because equipment of GIS was occurring problem of confidence used for a long time, partial discharge on-line diagnosis systems have been importantly recognized. Partial discharge (PD) detection is an effective means for monitoring and evaluation of dielectric condition of gas insulated system (GIS). The ultra-high-frequency (UHF) PD detection technique can detect and locate the PD sources inside GIS by detecting electromagnetic wave emitted from PD source. Therefore, real-time diagnostic system using UHF detection method has been developed for this application is being expanded gradually. However, the signal of partial discharge occurring in SF6 gas is very weak and susceptible to external noises which mainly consist of PD in air. Thus, it is important to distinguish the PD in SF6 gas more sensitively from the external noises. Unfortunately, these external noise signals and the partial discharge signals have very similar characteristics. Therefore, to solve this problem, we need the signal processing method for distinguish partial discharge signals with external noise signals for improvement of SNR(signal to noise ratio) and sensitivity. In this paper, we proposed internal signal processing method for removing external noise signals with built-in pre.amplifier and frequency conversion circuit.

소형전원장치에 대한 통계적 분석 (Statistical analysis for small power module)

  • 신재경
    • Journal of the Korean Data and Information Science Society
    • /
    • 제22권4호
    • /
    • pp.735-740
    • /
    • 2011
  • 최근 전자기기의 소형화, 인텔리전트화, 다기능화, 광대역화에 관심이 집중되어 많은 발전이 이루어졌으며, 이들 전자기기들에 이용되는 모듈형의 전원장치 (SMPS : Switching-mode power supply)도 소형화, 경량화, 고효율화, 고신뢰성화, 저노이즈화를 실현하고 있다. 85~265 볼트교류전압(VAC : Voltage alternating current) 상용 전원을 공급받아 DC 출력을 공급하는 전원장치인 파워모듈은 마이크로컨트롤러, 릴레이 등 전기, 전자 회로용 전원 공급기를 간단하고 쉽게 설계하도록 개발되고 있다. 이 모듈은 전원을 사용하는 장비에 광범위하게 적용할 수 있어 에너지 절감이라는 세계적인 대과제에 적합한 제품이기는 하나 제품의 품질과 성능에 대한 통계적분석이 필요한 바 적용제품의 부하별, 출력전압별 성능분석을 하여 그 문제점을 찾아보려고 한다.

일상생활 중 건강모니터링을 위한 착용형 심전도계측 시스템 개발 (Development of the wearable ECG measurement system for health monitoring during daily life)

  • 노윤홍;정도운
    • 센서학회지
    • /
    • 제19권1호
    • /
    • pp.43-51
    • /
    • 2010
  • In this study, wearable ECG measurement system was implemented for health monitoring during daily life. A wearable belt-type ECG electrode worn around the chest by measuring the real-time ECG is produced in order to minimize the inconvenience in wearing. The measured ECG signal is transmitted via an ultra low power consumption wireless data communications unit to personal computer using Zigbee-compatible wireless sensor node. The ECG monitoring program is developed at end user which is personal computer. The measured ECG contains many noises mainly due to motion artifacts. For ECG signal processing, adaptive filtering process is proposed which can reduce motion artifacts efficiently and accurately than digital filter. The experimental results show that a reliable performance with high quality ECG signal can be achieved using this wearable ECG monitoring system.

Time-Hopping PPM 변조를 이용한 UWB 통신 시스템의 성능 평가 (Performance Analysis of UBW Communication System using Time-Hopping PPM modulation)

  • 변건식;이민혁;전제훈
    • 한국정보통신학회논문지
    • /
    • 제8권1호
    • /
    • pp.220-226
    • /
    • 2004
  • UWB 통신은 높은 전송속도와 저전력 통신이 가능하다는 이유로 최근에 매우 각광을 받는 통신 응용분야이다. 따라서, 다양한 UWB 통신 기술의 적용을 위하여 UWB 신호의 특성과 변조 방법을 연구하는 것은 매우 중요하다. 본 논문에서는 UWB 통신에 사용 가능한 가우시언 모노펄스의 특성을 분석하고 PPM 변조 방법과 PAM 변조방법의 성능을 비교하였다. 또한 다양한 UWB 통신 환경에서의 중심 주파수가 다른 QPSK 시스템의 간섭 효과를 분석하였으며 간단한 UWB 송수신 시스템을 시뮬레이션 하였다.

군집 비행 드론의 충돌 방지를 위한 UWB 레이다의 속도 감응형 CFAR 최적화 연구 (Adaptive CFAR implementation of UWB radar for collision avoidance in swarm drones of time-varying velocities)

  • 이새미;문민정;천형일;이우경
    • 한국정보통신학회논문지
    • /
    • 제25권3호
    • /
    • pp.456-463
    • /
    • 2021
  • 본 연구에서는 군집 드론 시스템에서 이동 드론의 충돌방지를 위해 레이다를 도입하였다. 드론은 비행 중 불규칙한 속도 변화로 인해 반사파의 클러터가 증가되어 탐지 성능이 저하되고 이로 인해 충돌 방지 레이다의 성능에 영향을 준다. 본 논문에서는 UWB(Ultra Wide-Band) 레이다를 적용하여 비행하는 드론을 탐지하고, 반사파 신호 분석을 통해 획득한 거리 및 속도 정보의 정확도를 개선하는 방안을 제시한다. 이동 드론의 속도 변화에 따른 속도 감응형 CFAR(Constant False Alarm Rate)를 구현하여 오경보율을 일정하게 유지하면서 클러터를 효과적으로 제거하는 방안을 구현한다. 알고리즘의 검증을 위해 실제 상용 드론에 대한 레이다 관측 실험을 수행하고 불규칙하게 비행하는 드론의 탐지 성능이 개선됨을 보인다.