• Title/Summary/Keyword: type of specimens

Search Result 2,202, Processing Time 0.035 seconds

The effects of Hydroxyapatite nano-coating implants on healing of surgically created circumferential gap in dogs

  • Chae, Gyung-Joon;Lim, Hyun-Chang;Choi, Jung-Yoo;Chung, Sung-Min;Lee, In-Seop;Cho, Kyoo-Sung;Kim, Chong-Kwan;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.38 no.sup2
    • /
    • pp.373-384
    • /
    • 2008
  • Purpose: The aim of this study is to compare the healing response of various Hydroxyapatite(HA) coated dental implants by Ion-Beam Assisted Deposition(IBAD) placed in the surgically created circumferential gap in dogs. Materials and methods: In four mongrel dogs, all mandibular premolars and the first molar were extracted. After an 8 weeks healing period, six submerged type implants were placed and the circumferential cylindrical 2mm coronal defects around the implants were made surgically with customized step drills. Groups were divided into six groups : anodized surface, anodized surface with 150nm HA and heat treatment, anodized surface with 300nm HA and heat treatment, anodized surface with 150nm HA and no heat treatment, and anodized surface with 150nm HA, heat treatment and bone graft, anodized surface with bone graft. The dogs were sacrificed following 12 weeks healing period. Specimens were analyzed histologically and histomorphometrically. Results: During the healing period, healing was uneventful and implants were well maintained. Anodized surface with HA coating and $430^{\circ}C$ heat treatment showed an improved regenerative characteristics. Most of the gaps were filled with newly regenerated bone. The implant surface was covered with bone layer as base for intensive bone formation and remodeling. In case that graft the alloplastic material to the gaps, most of the coronal gaps were filled with newly formed bone and remaining graft particles. The bone-implant contact and bone density parameters showed similar results with the histological findings. The bone graft group presented the best bone-implant contact value which had statistical significance. Conclusion: Within the scope of this study, nano-scale HA coated dental implants appeared to have significant effect on the development of new bone formation. And additional bone graft is an effective method in overcoming the gaps around the implants.

Effect of Vital Tooth Bleaching Agent on Dentin Bonding (생활치 미백제가 상아질 접착에 미치는 영향)

  • Jeong, Na-Young;Jin, Myoung-Uk;Kim, Young-Kyung;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.2
    • /
    • pp.79-85
    • /
    • 2006
  • To evaluate the effect of vital tooth bleaching agent and alcohol pretreatment on dentin bonding, flat dentin windows were produced on the buccal side of the crowns of fifty-five extracted, human premolars. A bleaching gel, $Opalescence^{(R)}$ with 10% of carbamide peroxide (Ultradent Product, USA) was daily applied on the teeth of three experimental groups for six hours for 10 consecutive days, while teeth of a control group were not bleached. After 6 hours of bleaching gel application the specimens were washed and stored in saline until the next day application. After application of $One-step^{(R)}$ dentin bonding agent (Bisco, USA), $Z-250^{(R)}$ resin (3M-ESPE, USA) was bonded to dentin with a mount jig. Shear bond strength was measured with an Instron machine (Type 4202, Instron Corp., USA) after 24 hours. The results were analyzed using one-way ANOVA and Duncan's multiple range test at p < 0.05. Immediate bonding group showed significantly lower bond strength than un-bleached control group (p < 0.05). Ethanol-treated group showed significantly higher bond strength compared to immediate bonding group (p < 0.05). However, the bond strength of the ethanol treatment group was lower than that of the un-bleached control group (p < 0.05). There were no significant difference in shear bond strength between the 2-week delayed bonding group and the ethanol-treated group (p > 0.05) and between delayed bonding group and un-bleached control group (p > 0.05). In the condition of the present study. it seems that alcohol pretreatment after bleaching procedure can reduce the adverse effect of vital bleaching agent on dentin bonding.

Classification Schemes of Precast Beam-Column Connections According to Contribution of Deformation Components (변형기여분에 따른 프리캐스트 보-기둥 접합부의 분류방안)

  • Choi, Hyun-Ki;Choi, Chang-Sik
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.4
    • /
    • pp.545-553
    • /
    • 2014
  • This study suggested an integrated classification method for generalized characteristics of PC beam-column connection according to connection details. Quantifying the failure mode of PC-beam column connection and characteristics of corresponding details, this study suggested to use deformation contribution of each element of beam-column assemblage. According to the expected failure mode of beam-column connection assemblage, PC beam-column connection can be classified into 'equivalent monolithic system' and 'jointed system'. In this study, four test specimens were tested for verification of detailed classification method of PC beam-column connections. Test was carried out with typical beam-column connection test method. Load was applied at the top of test specimen and end of beams were restrained by hinge. In order to verify the deformation contribution of each test specimen, 34-LVDTs were mounted on test specimen. According to test results, deformation contribution of each test specimen have different characteristics. Deformation characteristics of joint and other components which are quantified by test results, equivalent monolithic system can be classified into two categories. Strong connection have extremely small deformation contribution of joint and much larger deformation contribution was shown in flexural behavior of beam. The other type of beam-column connection is ductile connection which allows the larger deformation in joint area compared with strong connection.

A Study on the High Temp. Tensile Properties of B1914 Ni-base Superalloy According to Crystal Structures of Poly-, Directionally Solidified- and Single Crystal Casts (Ni기 초합금 B1914의 다결정, 방향성 및 단결정 주조구조에 따른 고온 인장 특성 연구)

  • An, Seong-Uk;Jang,Yong-Seok;Yun, Dong-Han;Im, Ok-Dong;Larionov, V.;Grafas, I.;Jin, Yeong-Hun;Lee, Jae-Hun;Seo, Dong-Lee;O, Je-Myeong;Lee, Sang-Jun;Lim, Dae-Soon
    • Korean Journal of Materials Research
    • /
    • v.8 no.9
    • /
    • pp.831-836
    • /
    • 1998
  • The B1914 Ni-base superalloy was manufactured according to crystal structures of poly-, directionally solidified- and single crystals. We observe deformation as type of different crystal structure from room to high temperature. Specimens are controled by cooling rate and thermal gradient and then heat treatment in vacuum and then cooling with Ar gas. Different crystal structure has different stress-strain characteristic. At $600^{\circ}C$, yield strength and ultimate strength is increased single-, directionally solidified- and poly crystals in order.

  • PDF

Detection of infectious canine hepatitis virus by TaqMan real-time PCR method (TaqMan 실시간 PCR법에 의한 개 전염성 간염 바이러스의 검출)

  • Wang, Hye-young;Choi, Jae-yong;Lee, Mi-jin;Park, Jin-ho;Cho, Mae-Rim;Han, Jae-cheol;Choi, Kyoung-seong;Chae, Joon-seok
    • Korean Journal of Veterinary Research
    • /
    • v.44 no.4
    • /
    • pp.655-662
    • /
    • 2004
  • The aim of this work was the validation of a rapid real-time PCR assay based on TaqMan technology for the unequivocal identification of infectious canine hepatitis (ICH) virus, to be used directly on DNA purified from blood specimens. A real-time PCR system targeting at the E3 ORFA gene sequence of canine adenovirus type 1 was optimized and validated through comparative analysis of samples using conventional PCR system. The real-time PCR assay based on TaqMan technology could disclose 23 (37.7%) out of 61 samples as PCR positive. In contrast, 18 (29.5%) samples were found PCR positive when conventional PCR was applied on these samples. The use of the ABI Prism 7700 sequence detection system allowed the efficient determination of the amplified product accumulation through a fluorogenic probe. The entire real-time TaqMan PCR assay, including DNA extraction, amplification, and detection could be completed within 3 hours. The detection method of real-time TaqMan PCR assay was 1,000 times more sensitive than conventional PCR. Real-time TaqMan probe and primer set developed and optimized in this study is a sensitive, rapid and accurate method for detection of ICH virus and can be effective screening tool for the detection of ICH in a diagnostic laboratory routines.

The Status of Damage and Monitoring of Subterranean Termite (Reticulitermes spp.) (Blattodea: Rhinotermitidae) for Wooden Cultural Heritage in Korea (국내 목조문화재에 대한 지중 흰개미 피해 및 모니터링 현황)

  • Im, Ik-Gyun;Cha, Hyun-Seok;Kang, Won-Chul;Lee, Sang-Bin;Han, Gyu-Seong
    • Journal of Conservation Science
    • /
    • v.37 no.3
    • /
    • pp.191-208
    • /
    • 2021
  • In this study, the status of damage by subterranean termites and their management according to the region and type of domestic wooden cultural properties were identified. This was based on the survey reports of agencies conducting regular nationwide and regional monitoring of subterranean termites. In addition, using geographical information system (GIS) based on the survey contents, a map was constructed of termite infestation and its progress on 2,805 wooden cultural properties that were surveyed nationwide. Based on the map produced, a total of 486 cases of termite infestation were confirmed in wooden cultural properties during 2018-2019, of which 143 cases (approximately 29.4%) were confirmed to be owing to the invasion of termites in the ground and infestation of wood materials. A web platform and an application using a mapping application program interface were created to increase accessibility to the investigated damage status data. The methods employed by each institution for investigating and monitoring the invasion of termites in the ground included the use of detection dogs, visual observation, installation of wood specimens made of pine, and microwave equipment. However, it was confirmed that monitoring and survey methods were not applied to determine the territorial range of the subterranean termite colonies. Accordingly, the use of dyeing and mark-release-recapture methods were deemed necessary to understand the current status, such as calculating the scope of the target wooden cultural property, when monitoring subterranean termite colonies.

Performance Analysis of Laboratory and Field Luminance for Phosphorescent Line Marking and Preliminary Study of Luminance Analysis Using Digital Images (축광노면표시의 실내 및 현장 휘도 성능분석과 디지털이미지를 이용한 휘도분석 사전연구)

  • Kim, Sang Tae;Lee, Yong Mun;Kim, Heung Rae;Choi, Kee Choo
    • International Journal of Highway Engineering
    • /
    • v.18 no.6
    • /
    • pp.145-152
    • /
    • 2016
  • OBJECTIVES : Visibility at night can be improved by using retroreflection for short distances and phosphorescent line markings for long distances. In this study, we analyzed the characteristics of the phosphorescent line marking through a laboratory luminance test. Field performance analysis was performed through tests conducted on the road. We also examined the luminance measurement methods using the digital image obtained during the phosphorescent visibility evaluation. METHODS : In this study, the laboratory luminance test of the phosphorescent line marking was conducted using seven specimens to characterize the luminance changes according to the type of the glass beads, the thickness of the phosphorescent line marking, and the brightness and irradiation time of the light source. Phosphorescent and general line markings were made at 150 m to investigate the field luminance performance. A preliminary review of the luminance measurement methods was made using a digital image from a digital single-lens reflex (DSLR) camera. The measured luminance ratio of the general and the phosphorescent line markings was compared with the calculated luminance ratio using luminance analysis. RESULTS : Through the laboratory luminance test, it was seen that the change in luminance, which corresponds to the brightness of the light source, appears large but the influence of the thickness and irradiation time is low. The field performance test of the phosphorescent line marking conducted on the road involved measuring the luminance on the day the marking was made and 7 days after the marking was made. The luminance was found to be $190mcd/m^2$ at 30 min after sunset and approximately $10-12mcd/m^2$ 4h after sunset. The results of the luminance test were captured using a digital image for each time group. The luminance ratio of the phosphorescent line marking, when compared to that of the general line marking, showed a similar trend within a 13% maximum error. Additionally, when this luminance ratio is compared to the direct field measurement, it could be confirmed that the luminance ratio, as captured in the digital image, showed a similar tendency. CONCLUSIONS : 1) The change in luminance corresponding to the brightness of the light source is significant in comparison with that corresponding to the thickness and the irradiation time. In addition, the results of the field test for the phosphorescent line marking satisfied the phosphorescent fire protection standard. 2) We examined the validity of the luminance measurement method using a digital image and we concluded that the change in the luminance ratio shows a similar tendency in both the cases. The results can form the basis for luminance measurement methodology for the construction and maintenance of phosphorescent line markings.

Image Analysis on Upper Gastrointestinal(UGI) Series of Gastric Cancer (위암환자의 위장조영검사 영상분석)

  • Ko, Ju-Young;Cho, Young-Ki;Choi, Ji-Won
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.9
    • /
    • pp.251-258
    • /
    • 2010
  • Despite significant advance in laparoscopy, upper gastrointestinal (UGI) series is still generally carried out for preoperative localization of gastrectomy. The aim of the study was to compare the accuracy of UGI series and postoperative pathological findings in the diagnosis and localization of gastric cancer. A retrospective review was carried out for 102 patients who underwent gastrectomy between October 2007 and April 2009. Preoperative reports of UGI series were compared with postoperative pathology reports and the accuracy of the preoperative reports was calculated. Two radiographer retrospectively reviewed the analysis of UGI series. postoperative pathology reports of the surgical specimens, were compared with the preoperative reports of the location and extent of the tumor were correct in 81 case("sure", 79.4%) and incorrect in 21 case("failed, 20.6%). In 92 case UGI series revealed intestinal metaplasia (90.2%) at consensus review and these results demonstrate the limitation of the UGI series in the diagnosis of type IIb gastric cancer with size less than 1.0cm and the poor detection of gastric cancer is that the overlying mucous membrane often appears to be normal in these patients. In conclusion, UGI series is accurate the detection of the tumor localization and diagnosis of intestinal metaplasia. However, for the overcome with the limitation of UGI series should be used accurate technique for the region of the stomach. To achieve this goal, it is necessary to determine the changes of the mucus membrane of the stomach and UGI series is gaining acceptance as a standard method for preoperative gastric cancer screening.

EFFECTS OF ER:YAG LASER ABLATION ON THE DENTIN (Er:YAG 레이저를 이용한 치아삭제 효과)

  • Choi, Nam-Ki;Yang, Kyu-Ho;Park, Sang-Won;Kim, Ok-Joon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.4
    • /
    • pp.683-693
    • /
    • 2001
  • The purpose of this study was to evaluate the effects of Er:YAG laser on cutting efficacy and its histologic findings. Dentin specimens of human premolars and molars were used and irradiated by Er:YAG laser with noncontact handpiece type delivery system under different treatment condition of irradiation time. Cavity pattern and volume were evaluated to determine the cutting efficacy and following results were obtained. 1. Cutting volume of sound dentin was getting larger with time immersed in water increase 2. With the condition of irradiation (150mJ, 10Hz, 30sec), surface irregularity was more increased in sound dentin comparing to carious dentin. For the light microscopic examination, dentinal tubules were opened and ash flecks and cracks were noted with inconsistence of dentinal tubules. 3. In case of 30 sec. irradiation in carious dentin, dark zone was limited to small focus whereas 1 min. irradiation, more wider, and cracks were noted in the perpendicular to direction of dentinal tubules. For the 2 min. irradiation, cavity was the widest and more cracks were found.

  • PDF

Thermoelectric Properties of ZnkIn2O3+k(k=1∼9) Homologous Oxides (Homologous 산화물 ZnkIn2O3+k(k=1∼9)의 열전 특성)

  • Nam, Yun-Sun;Choi, Joung-Kyu;Hong, Jeong-Oh;Lee, Young-Ho;Lee, Myung-Hyun;Seo, Won-Seon
    • Korean Journal of Materials Research
    • /
    • v.13 no.8
    • /
    • pp.543-549
    • /
    • 2003
  • In order to investigate the thermoelectric properties of $Zn_{k}$ $In_2$$O_{ 3+k}$ homologous compounds, the samples of $Zn_{k}$ /$In_2$$O_{3+k}$ / (k = integer between 1 and 9) were prepared by calcining the mixed powders of ZnO and $In_2$$O_3$fellowed by sintering at 1823 K for 2 hours in air, and their electrical conductivities and Seebeck coefficients were measured as a function of temperature in the range of 500 K to 1150 K. X-ray diffraction analysis of the sintered samples clarified that single-phase specimens were obtained for $Zn_{k} /$In_2$$O_{3+k}$ with k = 3, 4, 5, 7, 8, 9. Electrical conductivity of the $Zn_{k}$ $In_2$$O_{3+k}$ / decreased with increasing temperature, and decreased with increasing k for k $\geq$ 3. The Seebeck coefficient was negative at all the temperatures for all compositions, confirming that $Zn_{k}$ $In_2$$O_{3+k}$ / is an n-type semiconductor. Absolute values of the Seebeck coefficient increased linearly with increasing temperature and increased with increasing k for k $\geq$ 3. The temperature dependence of the Seebeck coefficient indicated that Z $n_{k}$I $n_2$ $O_{3+k}$ could be treated as an extrinsic degenerate semiconductor. Figure-of-merits of Z $n_{k}$I $n_2$ $O_{3+k}$ were evaluated from the measured electrical conductivity and Seebeck coefficient, and the reported thermal conductivity. Z $n_{7}$ I $n_2$ $O_{10}$ has the largest figure-of-merit over all the temperatures, and its highest value was $1.5{\times}$10$^{-4}$ $K^{-1}$ at 1145 K.5 K.