• Title/Summary/Keyword: type of specimens

Search Result 2,202, Processing Time 0.036 seconds

Evaluation of Eddy Current Signals from the Inner Wall Axial Cracks of Steam Generator Tubes (증기발생기 전열관의 내면 축방향 균열에 대한 ECT 특성 평가)

  • Choi, Myung-Sik;Hur, Do-Haeng;Lee, Doek-Hyun;Park, Jung-Am;Han, Jung-Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.5
    • /
    • pp.501-509
    • /
    • 2001
  • For the enhancement of ECT reliability on the primary water stress corrosion cracks of nuclear steam generator tubes, of which the occurrence is on the increase, it is important to comprehend the signal characteristics on crack morphology and to select an appropriate probe type. In this paper, the sizing accuracy and the detectability for the inner wall axial cracks of tubes were quantitatively evaluated using the following specimens: the electric discharge machined notches and the corrosion cracks which were developed on the operating steam generator tubes. The difference of eddy current signal characteristics between pancake and axial coil were also Investigated. The results obtained from this study provide a useful information for more precise evaluation on the inner wall axial tracks oi stram generator tubes.

  • PDF

Corrosion of the non-beryllium dental casting Ni-Cr alloys for the denture base framework metal and the porcelain-fused-to-metal crown (베릴륨 불포함 치과 주조용 니켈-크롬 합금 중 금속의치상용 합금과 금속소부도재관용 합금의 부식에 관한연구)

  • Kim, Hong-Sik;Song, Jae-Sang;Park, Soo-Chul
    • Journal of Technologic Dentistry
    • /
    • v.34 no.4
    • /
    • pp.337-344
    • /
    • 2012
  • Purpose: This study examined the corrosion level by alloy type and pH, and used the corrosion levels as the dental health data. The study utilized one Ni-Cr alloy for the full and removable partial denture metal frameworks and two Ni-Cr alloys for porcelain-fused-to-metal crown, among the non-beryllium dental casting non-precious Ni-Cr alloys. Methods: The alloy specimens were manufactured in $10cm^2$ and stored in the corrosive solution(pH 2.2-4.4) in the electrical water bath($37^{\circ}C$) for seven days. Afterwards, the metal ions were quantitatively analyzed using the ICP. Results: Of the three metal alloys, Bellabond-Plus$^{(R)}$alloy and SOLIBOND N$^{(R)}$alloy, with 22% or higher chrome chemical contents, had higher corrosion resistance than Jdium-100$^{(R)}$alloy with 20% chrome chemical content. In all three alloys, the corrosion of Ni was highest, and metal ion corrosion was higher in the pH 2.2 corrosive solution. Conclusion: Although Ni-Cr alloy was not very corrosive, a Ni-allergic patient should not have Ni-Cr alloy prosthesis. The Ni-Cr alloy for porcelain-fused-to-metal crown should be designed for the dental porcelain to cover the whole crown.

A taxonomic study on Daucus species vegetated in islands off the Korean Peninsula (한반도 도서 지역에 서식하는 당근류의 분류학적 고찰)

  • Lee, Byoung-Yoon;Kwon, Sun Gyo;Oh, Kyoung-Hee
    • Korean Journal of Plant Taxonomy
    • /
    • v.34 no.4
    • /
    • pp.287-295
    • /
    • 2004
  • Daucus species vegetated in the island Dae-heug-san-do off the Korean Peninsula has been recorded as Daucus littoralis Sibth. et Sm. var. koreana Nakai, endemic to Korea in several flora. However, the name was revealed as a naked name, nomen nudum, because the valid publication and type specimens were found anywhere. Comparative observation on morphological characters between the Korean taxon of Daucus and D. littoralis reveals that the Korean vegetated in the island Dae-heug-san-do is not the D. littoralis, but the D. carota L. subsp. carota. The Korean name of the latter is designated newly as San-dang-geun. The new korean name, Seon-dang-geun, of the unrecorded taxon, D. carota subsp. maritimus (Lam.) Batt., is also given.

Development of Brake Disk Materials with Ni-Cr-Mo (Ni-Cr-Mo계 제동디스크 소재 개발)

  • Goo, Byeong-Choon;Lim, Choong-Hwan
    • Journal of the Korean Society for Railway
    • /
    • v.11 no.2
    • /
    • pp.188-194
    • /
    • 2008
  • Brake disks for rolling stock are exposed to thermal fatigue during braking, and thermal cracks occur on surface of disks. Thermal cracks can cause serious accidents, deterioration of braking performance and increase of maintenance cost due to frequent exchange of friction materials. In this study, candidate materials with high-heat resistance were selected by searching the literature. By using cast specimens made of the candidate materials, chemical composition, crystal structure and graphite type were analyzed. In addition, friction coefficient and wear were measured and compared with values for the disk material in service. As a result, it was shown that the NiCrMo has highest tensile strength and lowest friction coefficient and the disk material in service has the most stable friction characteristics.

Relations Between Impact Damage and Ply Angle Under Same Impact Energy Condition (同一한 衝擊에너지 條件下의 CFRP 斜交積層板의 衝擊損傷과 配向角의 關係)

  • ;笠野英秋
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.10
    • /
    • pp.1824-1832
    • /
    • 1992
  • This study investigated the compressive Young's modulus and the impactinduced damage of CFRP angle-ply laminate under same impact energy condition. The specimens of angle-ply laminate composites [0.deg.$_{6}$/ .theta..deg.$_{10}$/ 0.deg.$_{6}$] with .theta..deg. =30.deg., 45.deg., 60.deg. and 90.deg. were employed, and damaged by steel balls of diameter of 5mm and 10mm propelled by air gun type impact testing machine. The impact damaged zones were observed through a scanning acoustic microscope(SAM), and their cross-sections were observed through a scanning electron microscope(SEM). The compressive Young's moduli before and after impact were measured, and compared with the theoretical values calculated. The results obtained were as follows: (1) The damage areas on the interfacial boundaries showed more severe change on the back side interface than on the impact side interface with increasing ply-angle. (2) The damage areas on the interfacial boundaries became larger with increasing impact velocity or ply-angle. (3) The impact damaged zone showed the delamination on the interfacial boundaries and transverse cracks inside laminas. (4) The impact damaged zone was affected by the impactor size and speed or ply-angle under same impact energy condition. (5) Compressive Young's moduli before and after impact were lower than theoretical value, but showed a similar change according to ply-angle. (6) Compressive Young's moduli after impact were higher than those before impact, but there was no remarkable change in apparent compressive modulus after impact.t.act.

Corrosion Assessment of Storage Tank Floor using Magnetic Flux Leakage Technique (누설자속법을 이용한 저장탱크 바닥판재의 부식 평가)

  • Won, Soon-Ho;Cho, Kyung-Shik
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.1
    • /
    • pp.38-45
    • /
    • 2000
  • In this research, MFL technique has been studied for the inspection of storage tank floor. The reference specimens having 20%, 40%, 60% and 80% slot's are fabricated using the carbon steel plates of a 6mm and 10mm thick. Powerful permanent magnets and Hall effect sensors are used to this application. It is shown that our system is able to detect metal loss like a slot. Also, it is possible that slot diameter is measured using transverse type of Hall generator. It is demonstrated that MFL can not differentiate between the response from top side and bottom side slot. Flux leakage response from a bottom side indication is significantly lower in amplitude than that from an equivalent top side slot. It is essential to know this sensor lift-off distance because the MFL signal also changes considerably with the sensor lift-off distance.

  • PDF

Experimental study on the effect of low energy laser irradiation in Langerhans cell of Lanaged rat oral mucosa (저출력 레이저 조사 백서구강점막 창상부 Langerhans 세포에 미치는 영향에 관한 실험적 연구)

  • Cho, Jae-O;Hanks, Carl T.
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.15 no.3
    • /
    • pp.217-228
    • /
    • 1993
  • The purpose or this study was to observe the histological alteration of Langerhans cells on wound healing process in applying low energy laser irradiation. For this study, 50 Spraque-Dewly rats, weighing 150Gm or more were devided into control, experimental control group(0), 47.5Hz(1), 190Hz(3), 380Hz(5), 760Hz(7), lased group. All the experimental animals were made excision wound on buccal mucosa, 2mm depth, and lased with stoma laser (904nm, semconductor type ASGaAI, Sedalac France) 47.5Hz, 380Hz, 960Hz, 3minutes one time respectively except experimental control group. After the experiment, experimental animals were sacrificed after 24hours, 48hours, 72hours on each. Taken specimens were embedden in paraffin, sectioned 6-8u in thickness. And the langerhans cell were detected using ant S-100 protein antibody, and histochemically processed with Avidin Biotin complex method. All the Langerhan cells were calculated under light microspe in 400 multiplication field and standard deviation, probability test between each group were evaluated using statistical analysis system(S.A.S)program. Following results were obtained. 1. Langerhan cells were increased in experimental control group compared to that in control group(P<0.01). 2. 24hour after experiments, Langerhans cell were decreased compare to that in control group and control experimental group 5, 1, 3. Probability test shows significance between control experimental and 5, 1, 3 group on a =0.05 range. 3. 48our after experiment, Langerhans cells were decreased compare to that on experimental control group, and probability test shows significance between control experimental and 3, 7, 5 group an a=0.05 range. 4. 72hour after experiments, Langerhans cells were decreased compare to that on experimental control group and probability test on group comparison shows significance between control experimental and 1, 5 and 1 between 3, 7 between 3, and 5, between 7, respeilively on a=0.05 range. 5. Langerhans cells number in experimental group were decreased compare to that on experimental control group in applying laser irradiation.

  • PDF

Electrical Resistance Measurement in Characterizing the Internal Damage of Carbon Nanotube/Polypropylene Nanocomposites (전기저항 측정법을 이용한 탄소나노튜브/폴리프로필렌 나노복합재료의 내부 손상 예측)

  • Kim, Hak-Soo;Kwon, Dong-Jun;Wang, Zuo-Jia;Gu, Ga-Young;Kim, Dae-Sik;Lee, Chun-Soo;Park, Joung-Man
    • Composites Research
    • /
    • v.26 no.3
    • /
    • pp.201-206
    • /
    • 2013
  • The electrical resistance measurement was investigated as a damage monitoring method. In this study, 0.5 wt% Carbon nanotube reinforced polypropylene (CNT/PP) composites were evaluated under compressive fatigue loading. The shape of specimens was $20^{\circ}$ curved round type. Compression strength and electrical resistance were measured at different sections of specimen during compression. The microcracks of CNT/PP composites were detected based on the changing ratio of electrical resistance. Micro-damage during compressive fatigue test could be detected by electrical resistance measurements. The reason is that the contact points of CNTs in composites decreased under fatigue loading. During compressive fatigue test, larger change of electrical resistance was detected at the microcrack sections. It was proved that microcracks could be detected by electrical resistance measurement under compression test, whereas the real delamination parts were consistent with the predicted results by electrical resistance measurement.

Study on Tensile Properties of Polyamide 12 produced by Laser-based Additive Manufacturing Process (레이저 적층제조기술로 제작한 폴리아미드 12 시편의 인장특성 연구)

  • Kim, Moosun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.11
    • /
    • pp.217-223
    • /
    • 2019
  • The application of 3D printing technology is expanding due to the production of the complex-shape parts and the one-step manufacturing process. Moreover, various technical solutions in 3D printing are emerging through continuous research and development. Representative technologies include SLS technology, in which a desired area is sintered and laminated by irradiating a powder-type material with a laser. In addition, high-performance engineering plastic parts are being manufactured in increasing numbers. In this study, tensile specimens were fabricated from polyamide 12, a widely available polymer, and the glass bead-reinforced polyamide 12. The specimen-build orientation was divided into 0°, 45°, and 90° on the fabrication platform, and the tensile test temperature was -25℃, 25℃, and 60℃. The test results showed that the tensile modulus of both materials decreases as the build orientation becomes closer to 90°. In addition, the tensile strength of glass bead-reinforced PA12 showed more dependence on the build orientation than PA12. In addition, the tensile modulus and tensile strength decreased with increasing test temperature.

Application of New Type Accelerator for High Quality Shotcrete (고품질 숏크리트 개발을 위한 새로운 급결제 적용)

  • Park, Hae-Geun;Lee, Myeong-Sub;Kim, Jea-Kwon;Jung, Myung-Keun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.4 no.1
    • /
    • pp.45-55
    • /
    • 2002
  • From the early 1980's, the New Austrian Tunnelling Method (NATM) has been developed as one of the standard tunnelling methods in Korea. Approximately 10 years ago, wet-mix shotcrete with sodium silicate (waterglass) accelerator was introduced and widely used to tunnel lining and underground support. However, this accelerator had some disadvantages due to the decrease of long-term strength compared to plain concrete (without accelerator) and low quality of the hardened shotcrete. In order to compensate for these disadvantages, recently developed alkali-free accelerator has been successfully demonstrated in numerous projects and applications as a new material to make tunnels more durable and safer. An experimental investigation was carried out in order to verify the strength behavior of wet-mix Steel Fiber Reinforced Shotcrete (SFRS) with alkali-free accelerator. Compressive strength, flexural strength, and flexural toughness were measured by testing specimens extracted from the shotcrete panels. From the results, wet-mix SFRS with alkali-free accelerator exhibited excellent strength improvement compared to the conventional shotcrete accelerator.

  • PDF