• Title/Summary/Keyword: type of specimens

검색결과 2,202건 처리시간 0.039초

교류전류를 이용한 새로운 비파괴탐상법의 개발;표면결함과 이면결함의 평가 및 실기 부재의 결함 검출 (Development of the Advanced NDI Technique Using an Alternating Current : the Evaluation of surface crack and blind surface crack and the detection of defects in a field component)

  • 김훈;임재규
    • Journal of Welding and Joining
    • /
    • 제13권2호
    • /
    • pp.42-52
    • /
    • 1995
  • In the evaluation of aging degradation on the structural materials based on the fracture mechanics, the detection and size prediction of defect are very important. Aiming at nondestructive detection and size prediction ol defect with high accuracy and resolution, therefore, an lnduced Current Focusing Potential Drop(ICFPD) technique has been developed. The principle of this technique is to induce a focusing current at an exploratory region by an induction wire flowing an alternating current(AC) that is a constant ampere and frequency. Defects are assessed with the potential drops that are measured the induced current on the surface of metallic material by the potential pick-up pins. In this study, the lCFPD technique was applied for evaluating the location and size of the surface crack and blind crack made in plate specimens, and also for detecting the defects existing in valve, a field component, that were developed by SCC etc. during the service. The results of this present study show that surface crack and blind crack are able to defect with potential drop. these cracks are distinguished with the distribution of potential drop, and the crack depths can be estimated with each normalized potential drop that are parameters estimating the depth of each type crack. In the field component, the defects estimated by experiment result correspond with those in the cutting face of the measuring point within a higher sensitivity.

  • PDF

유도용해법으로 제조된 Co1-xNbxSb3의 열전특성 (Thermoelectric Properties of Co1-xNbxSb3 Prepared by Induction Melting)

  • 박종범;유신욱;조경원;장경욱;이정일;어순철;김일호
    • 한국재료학회지
    • /
    • 제15권2호
    • /
    • pp.89-92
    • /
    • 2005
  • The induction melting was employed to prepare Nb-doped $CoSb_3$ skutterudites and their thermoelectric properties were investigated. Single phase $\delta-CoSb_3$ was successfully obtained by induction melting and subsequent annealing at $400^{\circ}C$ for 2 hrs in vacuum. The positive signs of Seebeck coefficients for all the specimens revealed that Nb atoms acted as p-type dopants by substituting Co atoms. Electrical conductivity decreased and then increased with increasing temperature, indicating mixed conduction behavior. Electrical conductivity increased by Nb doping, and it was saturated at high temperature. Maximum value of the thermoelectric power factor was shifted to higher temperature with increasing the amount of Nb doping, mainly originated from the high Seebeck coefficient around mixed conduction temperature and high electrical conductivity.

In vitro study of fracture strength of provisional crown materials

  • Karaokutan, Isil;Sayin, Gulsum;Kara, Ozlem
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권1호
    • /
    • pp.27-31
    • /
    • 2015
  • PURPOSE. The purpose of this report was to evaluate the effect of the fabrication method and material type on the fracture strength of provisional crowns. MATERIALS AND METHODS. A master model with one crown (maxillary left second premolar) was manufactured from Cr-Co alloy. The master model was scanned, and the data set was transferred to a CAD/CAM unit (Yenamak D50, Yenadent Ltd, Istanbul, Turkey) for the Cercon Base group. For the other groups, temporary crowns were produced by direct fabrication methods (Imident, Temdent, Structur Premium, Takilon, Systemp c&b II, and Acrytemp). The specimens were subjected to water storage at $37^{\circ}C$ for 24 hours, and then they were thermocycled (TC, $5000{\times}$, $5-55^{\circ}C$) (n=10). The maximum force at fracture (Fmax) was measured in a universal test machine at 1 mm/min. Data was analyzed by non-parametric statistics (${\alpha}$=.05). RESULTS. Fmax values varied between 711.09-1392.1 N. In the PMMA groups, Takilon showed the lowest values (711.09 N), and Cercon Base showed the highest values (959.59 N). In the composite groups, Structur Premium showed the highest values (1392.1 N), and Acrytemp showed the lowest values (910.05 N). The composite groups showed significantly higher values than the PMMA groups (P=.01). CONCLUSION. Composite-based materials showed significantly higher fracture strengths than PMMA-based materials. The CADCAM technique offers more advantages than the direct technique.

트러서메쉬 보강 하프 슬래브의 구조적 거동에 관한 실험적 연구 (An Experimental Study on Structural Behavior of Half Slab Reinforced by Truss Mesh)

  • 고만영;김용부;박현수;정란
    • 콘크리트학회지
    • /
    • 제7권4호
    • /
    • pp.119-128
    • /
    • 1995
  • 이 연구는 최근 건설공사에서의 인력 및 원가의 절감, 공기의 단축 등을 도모하기 위하여 도입되고 있는 하프슬래브의 실용화를 위한 구조거동을 알아보기 위한 실험적 연구이다. PC 패널의 두께, 트러스메쉬의 형사, 가력하중의 형태를 변수로 총 17개의 시험체를제작하여 PC 패널, 하프슬래브, 하프슬래브-벽체 접합부의 휨성능 실험을 하였다. 실험결과, 부방향 하중을 받는 PC 패널의 휨강도가 설계강도보다 작게 나타났으나 정방향 하중을 받는 PC판넬과 덧침콘크리트의 분리현상이 발견되지 않았으며 휨강도 또한 일체로 타설한 부재와 같은 휨내력을 발현하였다. 따라서, 본 연구에서는동바리를 2.0-2.5m간격으로 설치하고, PC판넬과 덧침콘크리트와의 접합면을 조면처리하고 청결을 유지하면 사용상 문제가 없는 것으로 판단되었다.

자체 감지능 및 작동기용 다기능 하이브리드 나노복합재료의 계면 특성 및 소수성 표면 연구 (Interfacial Evaluation and Hydrophobicity of Multifunctional Hybrid Nanocomposites for Self-sensing and Actuation)

  • 왕작가;공조엘;장정훈;김명수;박종만
    • Composites Research
    • /
    • 제23권2호
    • /
    • pp.24-30
    • /
    • 2010
  • 니켈-나노분말/에폭시 복합재료의 계면 특성과 소수성을 자체-감지능과 작동기 측정을 위해 평가하였다. 경사형 시편을 사용하여 접촉 저항 및 저항도를 측정하였다. 자기장에서 복합재료의 작동성을 세가지 파형들, 즉, 싸인, 삼각, 그리고 사각파를 사용하여 평가하였다. 균일하지 않은 표면에 존재하는 소수성 영역 때문에 Ni-에폭시 나노복합재료의 어떤 부분은 초소수성보다는 다소 낮은 접촉각인 110도를 가졌다. 동적 접촉각은 정적 접촉각과 경향이 상호 일치함을 보였다. 니켈-나노분말의 고유의 금속성질 때문에 자체 감지를 확인하였으며, 또한 전자기장에 작동 반응을 잘 하였다. 니켈-나노분말/에폭시 복합재료의 최대 및 최적의 성능을 얻기 위해서, 레이져 변위 센서를 사용하여, 파형, 주파수, 그리고 전압의 함수로 작동기의 변위를 평가하였다. 니켈-나노분말/에폭시 복합재료의 작동은 적용된 주파수와 전압의 함수로써 증가하였다. 작동된 복합재료들의 연신율은 전압의 증가에 따라 삼각 혹은 사각파보다 싸인파에서 더욱 빨리 증가하였다.

Polystyrene 이장재가 아말감 변연부 미세누출에 미치는 영향 (THE EFFECT OF THE POLYSTYRENE LINER ON MICROLEAKAGE OF AMALGAM RESTORATION)

  • 이경선;노병덕;윤태철
    • Restorative Dentistry and Endodontics
    • /
    • 제23권2호
    • /
    • pp.586-596
    • /
    • 1998
  • Amalgam is one of the most commonly used dental restoration material because of its convenience, economic and physical properties. But microleakage in the tooth and amalgam interface has been its major problem, and many efforts have been made to overcome this shortcoming. The purpose of this study is to compare the effect of various liners on microleakage of amalgam restoration. Cavities were prepared on the buccal or lingual surface of ninety sound, extracted human premolars and six different liners (Tubulitec$^{(R)}$, Superbond D-liner II Plus$^{(R)}$, Superbond D-liner II Plus$^{(R)}$ with polymer, Scotchbond Multipurpose Plus$^{(R)}$, Copalite$^{(R)}$, No liner) were unapplied according to manufacturer's instructions and amalgam had been condensed immediately. The specimens were thermocycled by dipping in methylene blue dye at $5^{\circ}C$ and $55^{\circ}C$ for 1500 cycles. The amalgam-tooth interface was examined under stereobinocular microscope and the dye penetration was scored. The results were as follows : 1. The Tubulitec$^{(R)}$ group showed less microleakage than no liner or Copalite$^{(R)}$ group (p<0.01). 2. The Tubulitec$^{(R)}$, Superbond D-liner II Plus$^{(R)}$, Superbond D-liner II Plus$^{(R)}$ with polymer and Scotch bond Multipurpose Plus$^{(R)}$ groups were not significantly different. 3. The Copalite$^{(R)}$ and Scotchbond Multipurpose Plus$^{(R)}$ groups were not significantly different. Using the polystyrene liner and resin liners under admixed type of high-copper amalgam restoration significantly reduced microleakage in the tooth-amalgam interface. Further clinical studies on polystyrene liner are recommended.

  • PDF

대사초(Carex siderosticta Hance)의 외부형태, 분포 및 대사초 절 내에서의 분류학적 위치 (Morphological Features, Distributional Status of Carex siderosticta Hance in South Korea and Its Taxonomic Position Within Sect. Siderostictae)

  • 문애라;박정미;강신호;장창기
    • 한국자원식물학회지
    • /
    • 제25권2호
    • /
    • pp.257-270
    • /
    • 2012
  • 국내에 분포하는 대사초절에 속하는 3분류군의 외부형태형질을 분석하고 분자계통학적 연구를 수행하여 이들 간의 유연관계를 밝혔다. 대사초절 내의 기본종인 대사초의 외부형태학 특징을 재검토하여 기존 문헌과의 차이를 파악하였으며, 식물상 문헌 및 표본을 통해 국내 분포도를 작성하였다. 문헌에 언급된 형질들 중에서 잎의 형태는 생육지 조건에 따라 변이가 심하였지만, 지하경 생장 양상, 잎과 과낭의 털의 존재 등은 종수준에서 구분하는데 좋은 형질이었다. 분자계통학적 연구에서 털대사초는 독립된 종으로 처리되는 것을 지지하였다.

고려엉겅퀴, 정영엉겅퀴 및 동래엉겅퀴의 분류학적 실체 검토 (Taxonomic Identities of Cirsium setidens, C. chanroenicum and C. toraiense)

  • 송미장;김현
    • 식물분류학회지
    • /
    • 제35권4호
    • /
    • pp.227-245
    • /
    • 2005
  • 엉겅퀴속의 한국 특산종으로 인식되어온 고려엉겅퀴 (Cirsium setidens)와 정영엉겅퀴 (Cirsium chanroenicum) 그리고 동래엉겅퀴 (Cirsium toraiense)를 대상으로 분류군의 한계와 그 실체를 명확히 밝히고자 외부 형태학적 형질을 중심으로 수리분류학적 연구를 수행하였다. 고려엉겅퀴와 정영엉겅퀴는 주요 식별형질인 잎, 화서 및 총포에 관한 29개의 외부 형태학적 형질과 잎에 관한 12개의 주요 식별형질들을 비교 분석한 결과, 거의 구별이 되지 않는 하나의 집단으로 나타났다. 이러한 결과, 한국 특산종인 정영엉겅퀴는 고려엉겅퀴에 포함하는 것이 적절하다고 판단되며, 또한 동래엉겅퀴는 원기재문에 의한 생육지 조사, 기준표본과 표본관 소장 석엽표본 조사 등의 결과, 그 실체를 확인할 수 없었다.

플라이애시 종류에 따른 플라이애시 모르타르의 특성에 대한 연구 (Effect of Properties of Fly-ashes on the Characteristics of Fly-ash Mortars)

  • 김주형;박병선;정상화;최영철
    • 한국건설순환자원학회논문집
    • /
    • 제4권4호
    • /
    • pp.439-445
    • /
    • 2016
  • 최근 온실가스 저감 및 자원 재활용 등의 목적으로 플라이애시를 대량으로 사용하기 위한 연구가 활발히 진행되어오고 있다. 하지만, 플라이애시의 경우 생산 조건에 따른 품질 변동성이 크기 때문에 레드믹스트 콘크리트로의 대량 활용에 어려움이 있다. 본 연구에서는 국내 8개 화력발전소에서 생상되는 플라이애시를 대상으로 이를 이용한 플라이애시 모르타르에 대한 성능평가에 대한 연구를 수행하였다. 이를 위해 플라이애시에 대한 화학분석 등의 기초물성을 분석하였으며, 이를 활용한 플라이애시 모르타르에 대한 응결, 흐름, 압축강도 발현, 건조수축 및 탄산화 특성을 분석하였다. 각 화력발전소에서 생산된 플라이애시는 사용 연료 및 연소 조건 등의 상이에 의해 플라이애시의 구성 성분과 형상이 크게 다르게 나타났으며, 이러한 이유로 플라이애시 모르타르의 응결, 흐름, 압축강도, 건조수축, 탄산화에 대한 특성에 대한 변동성이 나타났다.

봉합재료에 따른 백서 미세혈관문합의 조직병리학적 연구 (COMPARATIVE HISTOPATHOLOGIC STUDY ON RAT VESSELS ANASTOMOSIS WITH 3 DIFFERENT SUTURE MATERIALS)

  • 성일용;김종렬
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제22권1호
    • /
    • pp.22-32
    • /
    • 2000
  • Purpose : Histopathologic observation was performed in order to determine which type of suture material is superior in microvascular anastomoses. Materials & Methods : The interrupted end to end anastomosis of the transected carotid arteries of 105 Sprague-Dawley rats, weighing 180 to 200g, were performed using 9-0 polypropylene ($Prolene^{TM}$, Ethicon, U.K.), 9-0 polyglactin 910 monofilament($Vicryl^{TM}$, Ethicon, U.K.), and 9-0 polyamide($Ethilon^{TM}$, Ethicon, U.K.) under intramuscular Ketamine and Xylazine anesthesia(5mg/100g). In all cases, 10 to 12 sutures were placed to complete the anastomoses. The specimens were obtained at 1, 2, 3 days, and 1, 2, 4 and 6 weeks after the surgery and prepared with H&E and Van-Gieson stains and investigated the histologic changes in anastomotic sites under light microscope. The histologic changes we were concerned about were followings- thrombus formation, intimal edema, infiltration of inflammatory cells in media and adventitia, proliferation of endothelial cells and subintimal hyperplasia. Results : 1. All of the anastomosed arteries were patent when they were exposed for examination. 2. Thrombus formation and intimal edema were most severe in Vicryl group, followed by Ethilon, Prolene group in order. 3. The inflammatory cells infiltrated to the media and the adventitia most severely in Ethilon group, followed by Vicryl, Prolene group in order. 4. There was little difference in proliferation of endothelial cells in each group. 5. Subintimal hyperplasia was greater in Vicryl group than the others, but there was no significant difference between the Prolene and Ethilon groups. Conclusions : On the basis of these observations, we could conclude that Prolene may be the better suture material for microvascular anastomoses regarding the tissue responses than Ethilon and Vicryl.

  • PDF