• Title/Summary/Keyword: type of defects

Search Result 994, Processing Time 0.035 seconds

A Study of Location Based Services Using Location Data Index Techniques (위치데이터인덱스 기법을 적용한 위치기반서버스에 관한 연구)

  • Park Chang-Hee;Kim Jang-Hyung;Kang Jin-Suk
    • Journal of Korea Multimedia Society
    • /
    • v.9 no.5
    • /
    • pp.595-605
    • /
    • 2006
  • In this thesis, GPS and the electronic mapping were used to realize such a system by recognizing license plate numbers and identifying the location of objects that move at synchronous times with simulated movement in the electronic map. As well, throughout the study, a camera attached to a PDA, one of the mobile devices, automatically recognized and confirmed acquired license plate numbers from the front and back of each car. Using this mobile technique in a wireless network, searches for specific plate numbers and information about the location of the car is transmitted to a remote server. The use of such a GPS-based system allows for the measurement of topography and the effective acquisition of a car's location. The information is then transmitted to a central controlling center and stored as text to be reproduced later in the form of diagrams. Getting positional information through GPS and using image-processing with a PDA makes it possible to estimate the correct information of a car's location and to transmit the specific information of the car to a control center simultaneously, so that the center will get information such as type of the car, possibility of the defects that a car might have, and possibly to offer help with those functions. Such information can establish a mobile system that can recognize and accurately trace the location of cars.

  • PDF

Magnetic Flux Leakage based Damage Quantification of Steel Bar (누설자속기법을 이용한 강봉의 손상 정량화 기법)

  • Park, Jooyoung;Kim, Ju-Won;Yu, Byoungjoon;Park, Seunghee
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.30 no.1
    • /
    • pp.63-70
    • /
    • 2017
  • In this paper, a magnetic flux leakage(MFL) based steel bar damage detection was first researched to quantify the signals from damages on the wire rope. Though many researches inspecting damages using a MFL method was proceeded until the present, the researches are at the level that diagnose whether damages are or not. This has limitation to take measures in accordance with the damage level. Thus, a MFL inspection system was modeled using a finite element analysis(FEM) program dealing with electromagnetism problems, and a steel bar specimen was adopted as a ferromagnetic object. Then, an experimental study was also carried out to verify the simulation results with a steel bar which has same damage conditions as the simulation. The MFL signals was nearly not affected by the increase of the inspection velocity, and the magnitudes of the signals are not identical according to the change of the defect width even the defects have same depth. On the basis of the analysis, the signal properties from the damages were extracted to classify the type of damages, and it could be confirmed that classification of damages using extracted signal properties is feasible.

Postoperative Assessment of Residual Oefects Following Surgical Closure of Ventricular Septal Defects (심실중격결손의 개심술 후 잔류단락에 관한 임상적 고찰)

  • 조준용;허동명
    • Journal of Chest Surgery
    • /
    • v.29 no.2
    • /
    • pp.147-152
    • /
    • 1996
  • his study was undertaken to assess the residual interventricular shunt following surgical closure of the isolated ventricular septal defect. From January 1989 through December 1993, 211 patients underwent surgical closure of the isolated ventricular septal defect. All patients had 2D-Echocardlo-graphic study after operation to rule out residual ventricular septal defect. There was a 9.5% incidence of a definite residual shunt. The type of ventricular septal defect, closure method of the defect and cardiopulmonary bypass time showed no significant differences between two groups. The sue of ventricular septal defect (6.3 $\pm$ 3.7mm versus 10.6 $\pm$ 5.8mm : p : 0.0034), aortic cross-clamping time(32.6 $\pm$ 15.0 minutes versus 48.5 $\pm$ 20.0 minutes, p : 0.0003), pulmonary-to-systemic pressure ratio(0.31 $\pm$ 0.22 versus 0.51 $\pm$ 0.33, p=0.019) and mean pulmonary artery pressure(20.3 $\pm$ 11.9 mmHg versus 29.1 $\pm$ 16.2 mmHg, p : 0.009) were meaningfully different between two groups. There were 9 insta ces of spontaneous closure of the residual shunts at mean 21 months of following up (ranged 1 ~43 months). In conclusion, we suggest that the size of ventricular septal defect, aortic cross-clamping time and mean pulmonary artery pressure may play an important role in occurance of residual ventricular septal defect.

  • PDF

In Vitro Isolation and Proliferation of Mouse Male Germ-Line Stem Cells (생쥐 생식줄기세포의 체외 분리 및 증식)

  • 김수경;김계성
    • Journal of Embryo Transfer
    • /
    • v.18 no.3
    • /
    • pp.243-248
    • /
    • 2003
  • Sperrnatogenesis, the process by which the male germ-line stem cells(GSCs; type A spermatogonia) divide and differentiate to produce the mature spermatozoa, occurs in the seminiferous tubules of the testis. The GSCs proliferate actively to produce two types of cells: other GSCs and differentiating spermatogonia. GSCs have unipotentcy, devoted solely to the generation of sperm. The function of GSCs has broad implications for development, disease, and evolution. Spermatogenesis is fundamental for propagation of species and the defects of this system can result in infertility or disease. The ability to identify, isolate, culture, and alter GSCs will allow powerful new approaches in animal transgenesis and human gene therapy relating to infertility. Until recently, research on stem cells in the testis has been limited because of technical difficulties in isolating and identifying these cell populations. Here, we were trying to find out optimal conditions for in vitro culture of GSCs for identifying and isolating GSCs. We collected mouse GSCs from 3-days old mouse by two-step enzyme digestion method. GSCs were plated and grown on mouse embryonic fibroblasts in Dulbecco's modified Eagle's medium (DMEM) containing 15% fatal bovine serum, 10 mM 2-mercaptoethanol, 1% non-essential amino acids, 1 ng/$m\ell$ bFGF, 10 $\mu$M forskolin, 1500 U/$m\ell$ human recombinant leukemia inhibitory factor (LIF). Over a period 3∼5 days, GSCs gave rise to large multicellular colonies resembling those of mouse pluripotent stem cells. After 5th passages, cells within the colonies continued to be alkaline phosphatase and Oct-4 positive and tested positive against a panel of two immunological markers(Integrin $\alpha$ 6 and Integrin $\beta$ 1) that have been recognized generally to characterize GSCs. SSEA-1, SSEA-3, and SSEA-4 also showed positive signals. Based on our data, these GSCs-derived cultures meet the criteria for GSCs itself and even other pluripotent stem cells. We reported here the establishment of in vitro cultures from mouse male GSCs.

A Study on Improving Performance Bond System for Efficient Execution of Public Construction Works (효율적인 공사수행을 위한 공사이행보증제도 개선방안 연구)

  • Kim, Myeongsoo
    • Korean Journal of Construction Engineering and Management
    • /
    • v.21 no.4
    • /
    • pp.21-29
    • /
    • 2020
  • This study analyzed problems of operating performance bond for public works and derived some suggestions for improvement. The Contract Law for Government Owner requires to submit performance bond which guarantees performing the construction contractor pays back compensation money when the obligation is not executed. Currently, first bid eligibility for participation is exactly required for executing company of performance bond obligation, not considering volume, technical level, and special type of remaining works. In collaboration contract, if guarantee accident occurs, it is obliged for remaining collaboration contractors to be qualified to fulfill the whole contract. This study proposes following improvement plan to solve problems of current performance bone in public works. Firstly, qualification criteria must be deregulated exceptionally for selecting proper contractor, which executing performance bond obligation, considering progress and characteristics of remaining works. Secondly, In collaboration contract, the prerequisite of remaining contractors' should be deregulated as 'implementation requirement of the remaining works'from'implementation requirement of the whole work'. Finally, defect responsibility should be included in liabilities of performance bond by specifying that owner or guarantee agency bear them.

A Study on the Hyperspectral Image Classification with the Iterative Self-Organizing Unsupervised Spectral Angle Classification (반복최적화 무감독 분광각 분류 기법을 이용한 하이퍼스펙트럴 영상 분류에 관한 연구)

  • Jo Hyun-Gee;Kim Dae-Sung;Yu Ki-Yun;Kim Yong-Il
    • Korean Journal of Remote Sensing
    • /
    • v.22 no.2
    • /
    • pp.111-121
    • /
    • 2006
  • The classification using spectral angle is a new approach based on the fact that the spectra of the same type of surface objects in RS data are approximately linearly scaled variations of one another due to atmospheric and topographic effects. There are many researches on the unsupervised classification using spectral angle recently. Nevertheless, there are only a few which consider the characteristics of Hyperspectral data. On this study, we propose the ISOMUSAC(Iterative Self-Organizing Modified Unsupervised Spectral Angle Classification) which can supplement the defects of previous unsupervised spectral angle classification. ISOMUSAC uses the Angle Division for the selection of seed points and calculates the center of clusters using spectral angle. In addition, ISOMUSAC perform the iterative merging and splitting clusters. As a result, the proposed algorithm can reduce the time of processing and generate better classification result than previous unsupervised classification algorithms by visual and quantitative analysis. For the comparison with previous unsupervised spectral angle classification by quantitative analysis, we propose Validity Index using spectral angle.

Vibration Modeling and Optimal Design of Differential Electromagnetic Transducer for Implantable Middle Ear Hearing Devices using the FEA (FEA를 이용한 이식형 인공중이용 차동전자 트랜스듀서의 진동 모델링과 최적 설계)

  • Kim Min-Kyu;Lim Hyung-Gyu;Han Chan-Ho;Song Byung-Seop;Park Il-Yong;Cho Jin-Ho
    • The Journal of the Acoustical Society of Korea
    • /
    • v.24 no.7
    • /
    • pp.379-386
    • /
    • 2005
  • Among various kinds of hearing aids which have been developed so far. the conventional air conduction hearing aids have some problems such as the acoustic distortion, an howling effect due to acoustic feedback. Another type of hearing aid. the cochlear implant system can be applied to the profound imparied person. However. it shows the disadvantage that there is no possibility of recovery of the acoustic organ such as ossicle. On the other hand. the implantable middle ear heaving device directly vibratos the ossicular chain and has better sound qualify. good cosmetics for appearance. and wide frequency responses so that it can overcome the defects or the conventional hearing aids. In this paper, a mathematical modeling and a momentum equation derivation of the DET has been performed. For the optimization of the structure dimension generating maximal vibrating force of the DET. the computer simulation using a finite element analysis (FEA) software has been performed. Also. the vibrating transducer has been designed to make the frequency characteristics or the transducer be similar to those of the normal middle ear. Through the experimental results, the measured vibration characteristics of the DET has been evaluated to verify the performance for the application to implantable middle ear hearing devices.

The development of the Ionizer using clean room (청정환경용 정전기 제거장치 개발)

  • Jeong, Jong-Hyeog;Woo, Dong Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.1
    • /
    • pp.603-608
    • /
    • 2018
  • Although the voltage-applied discharge method is most widely used in the semiconductor and display industries, periodic management costs are incurred because the method causes defects due to the absorption of ambient fine dust and causes emitter tip contamination due to the discharge. The emitter tip contamination problem is caused by the accumulation of fine particles in ambient air due to the corona discharge of the ionizer. Fuzzy ball generation accelerates the wear of the emitter tip and deteriorates the performance of the ionizer. Although a mechanical cleaning method using a manual brush or an automatic brush is effective for contaminant removal, it requires management of additional mechanical parts by the user. In some cases, contaminants accumulated in the emitter may be transferred to the wafer or product. In order to solve this problem, we developed an ionizer for a clean environment that can remove the pencil-type emitter tip and directly ionize the surrounding gas molecules using the tungsten wire located inside the ion tank. As a result of testing and certification by the Korea Institute of Machinery and Materials, the average concentration was $0.7572particles/ft^3$, the decay time was less than two seconds, and the ion valance was 7.6 V, which is satisfactory.

Open Heart Surgery of Ventricular Septal Defect in Infancy (영아기 심실중격결손의 개심술)

  • 조준용;허동명
    • Journal of Chest Surgery
    • /
    • v.29 no.3
    • /
    • pp.271-277
    • /
    • 1996
  • In selected cases, early corrective surgery is indicated in the management of infants having large ventricular septal defects. The risk of any surgical procedure in infancy is acknowledged to be great and should be avoided whenever possible. However this greater surgical risk is justified when the patient presents with intractable congestive heart failure, severe pulmonary hypertension, marked growth retardation, and recurrent prolonged lower respiratory infections. We analyzed 31 patients with ventricular septal defect in infancy who underwent surgical correction from January 1991 through December 1994. Age ranged from 6 months to 12 months with mean age of 9.2 months. Of the thirty-one patients, 23 patients were male and 8 patients were female. Mean body weight was 7. 4kg. The most common type of ventricular septal defect was perimembraneo s (64.5%). Associated cardiac anomalies were found in 17 patients (55.8%). Mitral regurgitation was the most commonly associated cardiac anomaly (16.1 %) and followed by patent ductus arteriosus (12.9%). When cardiac catheterization data were analysed, the most common range of Qp/qs, RpiRs, Pp/ps were 2.1∼ 3.0, 1-0.25, above 0.70 respectively. Among the indications of surgical correction, there were pulmonary hypertension in 20 patients, congestive heart failure in 3 patients, intractable respiratory infection in 10 patients and growth retardation in 14 patients. The most common surgical approach and method for closure of ventricular septal defect .were right atriotomy (58%) and Dacron patch closure (94%). Postoperative complications occurred in 10 cases (32%) and overall mortality was 12.9% (4 cases). All operative deaths in this series occurred in infants under the age of 8 months and weight of 8 kilograms.

  • PDF

Surgical Result of Congenital Mitral Regurgitation in Children (선천성 승모판폐쇄부전증 교정수술의 단기성적)

  • 홍유선;박영환
    • Journal of Chest Surgery
    • /
    • v.30 no.4
    • /
    • pp.373-377
    • /
    • 1997
  • Between January, 1991 and May 1995, mitral valve repair was undertaken on 32 patients under 15 years for congenital mitral regurgitation. Mean age was 24.0$\pm$26.1 months(range 3 months to 15 years), 16 patients were male and 16 patients were female associated cardiac anomalies were found in 26 patients (81%), and ventricular septal defects were noted in 18 patients(56%). In regards to pathologic findings, there were annular dilatation(n:7), leaflet prolapse(n=18), cleft leaflet(n=5) and restricted valve motion (n=2). The method of repair consisted of annuloplasty(Modif ed Devega type) in 14, repair of redundunt leaflet in 6, closure of cleft in 5, triangular resection in 2 and splitting of papillary muscle in one. There was no operative mortality and two late deaths occurred as a result of heart failure and sepsis. Tro patients required replacement of the mitral valve after 3 months and 7 months respectivehy because of recurrent mitral regurgitation. Actuarial survival was 92.5% at 46 months and actuarial freedom from reoperation was 95% at 12 months and 92.5% at 46 months. Actuarial freedom from valve repair failure was 68% at 12 months and 61.8% at 46 months. Although valve repair failure rate was high, we believe that mitral valve repair should be of rcrred to children because of low mortality and low reoperation rate.

  • PDF