Behavior and resistance of truss-type shear connector for composite steel-concrete beams

  • Lima, Jerfson M.;Bezerra, Luciano M.;Bonilla, Jorge;Silva, Ramon S.Y.R.C.;Barbosa, Wallison C.S.
    • Steel and Composite Structures
    • /
    • v.36 no.5
    • /
    • pp.569-586
    • /
    • 2020
  • The behavior of composite steel-concrete beams depends on the transmission of forces between two parts: the concrete slab and the steel I-beam. The shear connector is responsible for the interaction between these two parts. Recently, an alternative shear connector, called Truss Type connector, has been developed; it aligns efficient structural behavior, fast construction and implementation, and low cost when compared to conventional connectors applied in composite structures. However, there is still a lack of full understanding of the mechanical behavior of the Truss Type connector, due to its novelty. Thus, this study aims to analyze the influence of variation of geometric and physical parameters on the shear resistance of the Truss Type connector. In order to investigate those parameters, a non-linear finite element model, able to simulate push-out tests of Truss Type connectors, was specifically developed and validated with experimental results. A thorough parametric study, varying the height, the angle between rods, the diameter, and the concrete strength, was conducted to evaluate the shear resistance of the Truss Type connector. In addition, an equation to predict the resistance of the original Truss Type shear connector was proposed.

Applicability Evaluation of ㄱ Type Perfobond Rib Shear Connectors (ㄱ형 Perfobond 리브 전단연결재의 적용성 평가)

  • Lee, Heung-Su;Chung, Chul-Hun;Kim, Byung-Suk;Kang, Jae-Yoon;Sohn, You-Shik
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.410-413
    • /
    • 2006
  • The ㄱ type perfobond rib shear connector is a ㄱ type flat steel plate with a number of holes punched through. This connector can be effectively used in girder with high shear. The ㄱ type perfobond rib shear connector exhibit very stiff behaviour under service load conditions and also had the characteristic of retaining a significant amount of load after the attainment of ultimate capacity. The ㄱ type perfobond rib shear connector with safety factor of 3 is applied shear connector of CFT composite girder. From static test result of CFT composite girder, relative displacement of 0.01mm measured at the service load moment. At design of the ㄱ type perfobond rib shear connector, applying safety factor of 3 was more conservative than test result.

  • PDF

Static Tests of ㄱ Type Perfobond Rib Shear Connectors when using Steel Tube (원형강관에 부착된 ㄱ형 perfobond 리브 전단연결재의 정적실험)

  • Lee Heung-Su;Chung Chul-Hun;Choi Wae-Ho;Kim Seok-Ki;You Sung-Kun;Kim Young-Ho
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.778-781
    • /
    • 2004
  • This paper summarizes the results of push-out test specimens with a new type of shear connector called ㄱ type perfobond rib. This connector is a flat steel plate with a number of holes punched through and strengthen rib's head part. According to experiment result, ㄱ type perfobond rib shear connector appeared that resistance force is increased than stud shear connector by $108\%$ and perfobond rib shear connector by $26\%$. The results obtained indicate that the perfobond rib connector is a viable alternative to the headed studs. An appreciable improvement in the shear capacity of the connection was observed when additional reinforcing bars were passed through the perfobond rib holes. For composite beams with concrete filled steel tubes, ㄱ type perfobond shear connectors exhibit adequate ductility and substantially higher capacities.

  • PDF

An Experimental Study on the Shear Connection of Inverted T-shape Composite Beam Encased Web (역T형강 합성보의 전단연결에 관한 실험적 연구)

  • Jeong, Jae-Hun;Kim, Jin-Mu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.5 no.4
    • /
    • pp.131-138
    • /
    • 2001
  • In inverted T-shape composite beam examine the structural behavior by experiment According to arrangement, type of stud connector, type of shear connector, reinforcement by welding of stirrup and a close analysis we came to these conclusion. 1) The compare result of bending strength according to arrange type of stud connector : A1-W(stud connector located web)specimen is exceed than A1-F(stud connector located flange). 2) B1-N(using prominence and depression of the web by shear connector) specimen is decrease than A1-W(using stud bolt by shear connector)specimen in bending strength and B2-N(reinforced by welding the stirrup to lower flange)specimen is similar with A2-W specimen. 3) According to reinforced by welding the stirrup to flange, the stiffness and bending strength of the beams are increase. A-scries stirrup comparatively low effective in the increase of strength by welding the stirrup to flange because enough composite effect show by stud connector, but B-series stirrup is comparatively high effective in shear connector effect because shortage of prominence and depression of the web.

  • PDF

Experimental Study on the Shear Capacity of Continuous Cap-Type Shear Connector (연속 캡 형상 전단연결재의 전단 내력에 관한 실험 연구)

  • Oh, Myoung Ho;Kim, Young Ho;Jeong, Sug Chang;Kim, Myeong Han
    • Journal of Korean Association for Spatial Structures
    • /
    • v.19 no.2
    • /
    • pp.91-99
    • /
    • 2019
  • The push-out tests have been conducted on the specimens which consist of the steel beam with U-shape section and the continuous cap-type shear connector. Existing formulas for the elevation of shear connector capacity were investigated on the basis of test results. The shear capacities of continuous cap-type shear connectors distinctly declined as the diameters of side-hole in the shear connector increased. The rebars through side-hole for the transverse reinforcement improved the shear capacity of continuous cap-type connector by 20 to 30 percent. It was not feasible to obtain the appropriate capacity values of continuous cap-type shear connectors made of thin steel plate like those of in this study, using the existing formulas. The new formula for reflecting the shear strength of penetrative bars was proposed based on the shear equation of Eurocode 4. The slip capacities of continuous cap-type shear connectors were shown to exceed the limit value of 6mm for the sufficiently ductile behavior.

A New T Type Perfobond Shear Connector for Composite Action (합성작용을 위한 새로운 Perfobond T형 전단연결재)

  • Chung, Chul-Hun;Kim, Jong-Suk;Shim, Chang-Su;Kim, Kwang-Soo;Jung, Kwang-Hoe;Sim, Chung-Wook
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.293-296
    • /
    • 2006
  • The results and interpretations of push-out tests on shear connector devices for composite bridges carried out in this study are presented. The devices under investigations are headed studes, perfobond rib, ㄱtype perfobond rib, T- Connector and a new type of shear connector called T type perfobond rib. This new connector is flat steel plate with a number of holes punched through. The results obtained indicate that the T type perfobond rib shear connectors exhibit adequate ductility and substantially higher capacities. Therefore for composite beams utilizing reinforced concrete slabs, the T type perfobond rib shear connectors is a viable alternative to the headed studs.

  • PDF

Experimental Study on the Shear Capacity of Cap-Type Shear Connectors With Constant Intervals (단속배치된 캡 형상의 전단연결재의 전단내력에 관한 실험 연구)

  • Oh, Myoung Ho;Lee, Min Seok;Kim, Young Ho;Kim, Myeong Han
    • Journal of Korean Association for Spatial Structures
    • /
    • v.18 no.2
    • /
    • pp.121-128
    • /
    • 2018
  • The push-out tests have been conducted on the specimens which consist of the steel beam with U-shape section and the cap-type shear connectors with constant intervals. Existing equations for the evaluation of shear connector strength have been investigated on the basis of test results. The reinforcing bars for longitudinal reinforcement and the penetrative bars for transverse reinforcement didn't have much effect on the shear capacity of the cap-type shear connector. The larger the width of cap-type shear connector was profiled, the greater the shear strength turned. The shear capacities of cap-type shear connectors with constant intervals were evaluated on the basis of push-out test results, and those were possible to be determined with proper safety margin using the Eurocode 4. The slip capacity of cap-type shear connector was shown to exceed the limit value of 6mm for sufficiently ductile behavior.

Performance Analysis of Automobile Type Air Conditioner Tube Connector (자동차용 에어컨 튜브 커넥터의 성능 해석)

  • Jang, Sung-Cheol;Kim, Nam-Kyung
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.6 no.2
    • /
    • pp.52-58
    • /
    • 2007
  • This study shows a numerical method to predict automobile type air conditioner tube connector in the forming process. The simulation approach with 3-D FEM program(ABAQUS) for forming process, forming process simulation is in good agrement with it in tendency. Finally, we compared the forming result with simulation. The result of research showed thai forming process technology is promising to produce automobile type air conditioner tube connector.

  • PDF

Static Strength Evaluation Equations of ㄱType Perfobond Rib Shear Connectors (ㄱ형 perfobond 리브 전단열결재의 정적 강도평가식)

  • Lee Heung-Su;Chung Chul-Hun;Sohn You-Shik
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05a
    • /
    • pp.451-454
    • /
    • 2005
  • The ㄱ type perfobond rib shear connector is a ㄱ type flat steel plate with a number of holes punched through. This connector can be effectively used in girder with high shear. The ㄱ type perfobond rib shear connector exhibit very stiff behaviour under service load conditions and also had the characteristic of retaining a significant amount of load after the attainment of ultimate capacity. A regression analysis, which is based on a model that takes into account the contributions of concrete dowels formed by the rib holes, the transverse reinforcement, the strength of concrete in front of the rib, and the ㄱ type plate as well as a nonlinear finite element analysis, is used in the derivation. An empirical equation for the design of ㄱ type perfobond rib shear connector is proposed.

  • PDF

Shear resistance characteristic and ductility of Y-type perfobond rib shear connector

  • Kim, Sang-Hyo;Park, Se-Jun;Heo, Won-Ho;Jung, Chi-Young
    • Steel and Composite Structures
    • /
    • v.18 no.2
    • /
    • pp.497-517
    • /
    • 2015
  • This study evaluates behavior of the Y-type perfobond rib shear connector proposed by Kim et al. (2013). In addition, an empirical shear resistance formula is developed based on push-out tests. Various types of the proposed Y-type perfobond rib shear connectors are examined to evaluate the effects of design variables such as concrete strength, number of transverse rebars, and thickness of rib. It is verified that higher concrete strength increases shear resistance but decreases ductility. Placing transverse rebars significantly increases both the shear resistance and ductility. As the thickness of the ribs increases, the shear resistance increases but the ductility decreases. The experimental results indicate that a Y-type perfobond rib shear connector has higher shear resistance and ductility than the conventional stud shear connector. The effects of the end bearing resistance, resistance by transverse rebars, concrete dowel resistance by holes, and concrete dowel resistance by Y-shape ribs on the shear resistance are estimated empirically based on the push-out test results and the additional push-out test results by Kim et al. (2013). An empirical shear resistance formula is suggested to estimate the shear resistance of a Y-type perfobond shear connector for design purposes. The newly developed shear resistance formula is in reasonable agreement with the experimental results because the average ratio of measured shear resistance to estimated shear resistance is 1.024.