• 제목/요약/키워드: tympanic temperature

검색결과 35건 처리시간 0.022초

신생아의 직장체온과 고막 및 액와체온과의 비교 (Comparison of Rectal Temperature with Axillary and Tympanic Temperature)

  • 황진순;송경애
    • 기본간호학회지
    • /
    • 제4권2호
    • /
    • pp.351-358
    • /
    • 1997
  • Body temperature should be measured accurately to assess neonate's condition for proper care. Temperatures measured in rectal, axillary and tympanic site were compared in 129 normal neonates to find out proper nursing time for measuring temperature and the validity of fever detection. The results were as follows : 1. Mean temperatures of axillary and tympanic site($36.85^{\circ}C,\;37.12^{\circ}C$) were significantly lower than those of rectal site($37.19^{\circ}C$). 2. Mean nursing time for measuring body temperature was significantly higher and lower in axillary and tympanic temperatures(159.49 seconds, 11.07 seconds) than in rectal temperature(105.62 seconds). 3. Tympanic and axillary temperatures were significantly correlated with rectal temperature (r=0.85, r=0.78) and the significant correlation was demonstrated between tympanic and axillary temperatures(r=0.76). 4. Sensitivity, specificity, positive and negative predictive values were 0.87, 0.90, 0.72, 0.96 for detecting fever respectively. The above findings indicated that the tympanic thermometer offers a useful alternative to conventional methods.

  • PDF

수은체온계와 고막체온계의 측정치와 측정시 경험에 관한 비교연구 (A comparison study of measured values and subjective experience of mercury thermometer and tympanic thermometer)

  • 민순
    • 한국간호교육학회지
    • /
    • 제4권1호
    • /
    • pp.95-106
    • /
    • 1998
  • This study aims to provide a better nursing service in the dimension of economizing time and human efforts. This is to present some basic knowledge necessary to improving a nursing quality in measuring body temperature by analyzing the contents that the objects experienced at the time of measure with tympanic thermometer and mercury thermometer Subjects of the survey consisted of 71 college students, 47 adult patients and 40 pediatric patients. The results were as follows : 1. The oral temperature by mercury thermometer and tympanic thermometer with oral mode was : $36.83^{\circ}C$ by mercury thermometer and $37.02^{\circ}C$ by tympanic thermometer in college students : it showed an significant difference statistically. 2. Comparsion between oral mode and rectal mode by tympanic thermometer in college students : $37.03^{\circ}C$ by oral mode and $37.55^{\circ}C$ by rectal mode and this defference was significant statistically 3. Comparision between rectal temperature by mercury thermometer and rectal mode of tympanic thermometer : $37.54^{\circ}C$ by mercury thermometer and $37.73^{\circ}C$ by tympanic thermometer, it showed a significant difference statistically. 4. Comparision between oral temperature by mercury thermometer and oral mode of tympanic thermometer of the pediatric patients : $36.51^{\circ}C$ by mercury temperature and $36.94^{\circ}C$ by tympanic thermometer, it showed a significant difference statistically. 5. Comparision between oral body temperature by mercury thermometer and oral mode of tympanic thermometer of the adult patients : $36.56^{\circ}C$ by mercury thermometer and $36.90^{\circ}C$ by tympanic thermometer, it did not show statistically any difference. 6. At the measure by mercury thermometer this data can classified In three main categorise : their feeling to a thermometer, thermometer itself and aspect physical of the clients. It is considered that an subjective experience to tympanic thermometer was more positive.

  • PDF

신생아의 서혜, 직장, 액와, 고막 체온 측정 비교 (Comparison of Inguinal, Rectal, Axillary,and Tympanic Temperature in Newborns)

  • 구현영;손정태
    • Child Health Nursing Research
    • /
    • 제11권2호
    • /
    • pp.203-210
    • /
    • 2005
  • Purpose: In order to identify the usability of inguinal temperature in a neonatal unit, this study was done to compare inguinal temperature of newborns with rectal, axillary, and tympanic temperatures. Method: Fifty-one normal newborns admitted to the nursery of a university affiliated hospital participated in the study. Tympanic temperatures were taken with a tympanic thermometer. Inguinal, rectal, and axillary temperatures were taken with glass mercury thermometers, and were recorded every 1 minute until the reading remained constant for 2 times. The data were analyzed using the SPSS program. Result: The measurement time for inguinal temperatures in newborns was significantly longer than that for rectal temperatures, but was shorter than that for axillary temperatures. The mean temperature for the newborn's inguinal site was lower than for rectal, axillary, and tympanic temperatures (the lower side), but wasn't different from tympanic temperature (the upper side). The inguinal temperature was significantly correlated with rectal, axillary, and tympanic temperature. The inguinal temperature was not different according to general characteristics of the newborn. Conclusion: These findings indicate that measurement of inguinal temperature is a useful alternative to rectal temperature.

  • PDF

고막체온과 액와체온의 비교 연구 - 성인대상자를 중심으로 - (Comparison of Tympanic and Axillary Temperatures)

  • 유재희;조현숙
    • 기본간호학회지
    • /
    • 제16권2호
    • /
    • pp.162-170
    • /
    • 2009
  • Purpose: To verify the usability of tympanic temperature measurement for adults, a comparison of tympanic and axillary temperatures was done. Method: The study was conducted during October 2008, and participants were 110 female nursing students. Axillary temperatures were taken with glass mercury thermometers for 5, 7 and 10 minutes. Tympanic temperatures were taken with Infrared Thermometer IRT 4520 on both ears, twice at a 5-second interval. The data were analyzed using the SPSS 12.0 program. Results: In the 1st measurement, the mean for right tympanic temperatures ($0.06^{\circ}C$) and for left ($0.03^{\circ}C$) were significantly higher than the 2nd. A comparison of mean temperatures for right and left, showed that the mean for the left side on the 1st measurement was significantly higher ($0.01^{\circ}C$) than the right. Also the temperature on left side in the 2nd measurement was higher ($0.04^{\circ}C$) than the right 2nd, but not significantly higher. The mean temperature for right and left tympanic on 1 st and 2nd measurements were significantly higher than axilla for 5 minutes ($0.58^{\circ}C$), for 7 minutes ($0.52^{\circ}C$), and for 10 minutes ($0.43^{\circ}C$). The tympanic temperature was the most closely correlated with the axillary temperature at 10 minutes. Conclusion: Findings indicate that measurement of tympanic temperature is a useful alternative to axillary temperature taken for 10 minutes.

  • PDF

Axillary temperature measurements based on smart wearable thermometers in South Korean children: comparison with tympanic temperature measurements

  • Choi, Younglee;Ahn, Hye Young
    • Child Health Nursing Research
    • /
    • 제28권1호
    • /
    • pp.62-69
    • /
    • 2022
  • Purpose: This study explored the validity of a new type of thermometer and parent satisfaction with the new device. This 24-hour continuous monitoring smart wearable wireless thermometer (TempTraq®) uses a very small semiconductor sensor with a thin patch-like shape. Methods: We obtained 397 sets of TempTraq® axillary temperatures and tympanic temperatures from 44 pediatric patients. Agreement between the axillary and tympanic measurements, as well as the validity of the TempTraq® axillary temperatures, were evaluated. Satisfaction surveys were completed by 41 caregivers after the measurements. Results: The TempTraq® axillary temperatures demonstrated a strong positive correlation with the tympanic temperatures. The Bland-Altman plot and analysis of TempTraq® axillary temperatures and tympanic temperatures showed that the mean difference was +0.45 ℃, the 95% limits of agreement were -0.57 to +1.46 ℃. Based on a tympanic temperature of 38 ℃, the results of validity of fever detection were sensitivity 0.85 and specificity 0.86. Satisfaction scores for TempTraq® temperature measurement were all > 4 points (satisfactory). Conclusion: TempTraq® smart axillary temperature measurement is an appropriate method for measuring children's temperatures since it was highly correlated to tympanic temperatures, had a reliable level of sensitivity and specificity, and could be used safely and conveniently.

체온측정방법의 정확도와 간호시간 및 발열감별 타당도 비교 (Accuracy of Temperature Measurements, Nursing Time for Measuring Temperature and the Validity of Fever Detection)

  • 송경애;강성실;황진순;김명자
    • 기본간호학회지
    • /
    • 제5권1호
    • /
    • pp.33-45
    • /
    • 1998
  • The aim of this study was to investigate what is the most accurate and quick temperature measurement among rectal, auxiliary and tympanic routes. The body temperatures of 86 preform infants in incubators, a controlled environment, were measured at three different sites. The measurements were taken to examine the accuracy of the temperatures, proper nursing time for measuring the temperatures and the validity of fever detection. The results were as follows : 1. The mean temperature was significantly lower in the auxiliary site($36.71^{\circ}C$) and higher in the tympanic site($37.27^{\circ}C$) than in the rectal site($37.03^{\circ}C$). 2. The mean nursing time for measuring body temperature was significantly longer in the auxiliary site(171.65 seconds) and shorter in the tympanic site(17.70 seconds) than in the rectal site(83.33 seconds). 3. The nursing time for measuring body temperature included the time needed for preparation, measuring, as well as the post-measuring time. It was found that the time required to prepare for measuring the temperature of the rectal site was significantly longer than for other sites. In addition, the time needed to measure the temperature of the auxiliary site was significantly longer than in the other sites. Finally, the nursing time needed for measuring the auxiliary temperature(171.65 seconds) was the longest among the three sites whereas the nursing time for the tympanic site was the shortest(17.70 seconds). 4. Rectal temperature was significantly correlated to the tympanic(r=0.67) and auxiliary temperatures(r=0.69). Tympanic temperature was also significantly correlated to the auxiliary temperature(r=0.74). 5. The sensitivity, specificity, positive and negative predictive values of tympanic temperatures for detecting fever were 1.00, 0.80, 0.24, and 1.00, respectively. Those for the auxiliary temperatures were 0.00, 0.99, 0.00, and 0.94, respectively. Thus the level of fever detection was lower in the auxiliary temperatures than in tympanic temperatures. The above findings indicate that the tympanic method of temperature measurement offers a useful alternative to conventional methods.

  • PDF

원적외선 온열효과가 체온에 미치는 생리적 영향 (Physiological Influences caused by Warming Effect of Far-infrared Radiation in Body temperature)

  • 이해광;강세구;이충근;장윤호;민세동;김성중;이명호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 D
    • /
    • pp.2792-2794
    • /
    • 2003
  • In this paper, we measure the tympanic temperature and axillary temperature after far-infrared radiation. The subjects consist of 20 peoples($20s{\sim}60s$) regardless of age or sex. First of all, the subjects lied in mat without the hyperthermia induced by FIR(Far-infrared radiation) for 5 minutes(relaxation) and then lied in mat with the hyperthermia induced by FIR($40{\sim}65^{\circ}C$) for 30 minutes. At this all process, the tympanic temperature and axillary temperature were measured at every 5 minutes. Before FIR was radiating on the human body, the tympanic temperature were $1.05^{\circ}C$ higher than axillary temperature. But after FIR, axillary temperature were $0.217^{\circ}C$ higher than tympanic temperature and the difference of two parameters was decreased.

  • PDF

체온측정시간 및 고막체온계의 정확도와 신뢰도에 관한 연구 (Study on the Body Temperature Measuring Time and Accuracy and Reliability of Tympanic Thermometer)

  • 정인숙;유은정
    • 기본간호학회지
    • /
    • 제4권1호
    • /
    • pp.19-30
    • /
    • 1997
  • This study was to investigate the method for shortening the body temperature (BT) because it takes a long time and is impractical to measure axillary or oral BT with mercury thermometer, The first approach was to identify BT change according to the measuring time and determine the clinically not statistically avaiable and optimal BT measuring time. The second was to test the accuracy of tympanic thermometer. It can measure BT within a few seconds, so if it is approved accurate, we can save BT measuring time by substitute tympanic thermometer for mercury thermometer. This study was conducted from 1, to 30 June, 1996. The subjects were 12men students of medicalk college and 29 women students of nursing school. The results were as follows ; 1) The 3, 5, 7, 9, 11, 13minute-measured axillary BT and 3, 5, 7, minute-measured BT showed somewhat linear relationship with time. It was difficult to find the optimum measuring time which were clinically significant. 2) For axillary tempeiature, the measuring time which were not statistically different was 11 and 13minute. But the real BT difference between 3 and 13minute, or between 5 and 13minute were very small and was within the range of daily variation. 3) For oral temperature, there was no intervals which showed the statistically insignificant. But like as axillary temperature, the difference between 3 and 7, or 5 and 7 minute were trivial by $0.3^{\circ}C$ and by $0.1^{\circ}C$ respectively. 4) Tympanic temperatures were lower than oral BTs which were measured with mercury thermometer by $0.26^{\circ}C$ (with ear tug) and $0.15^{\circ}C$(without ear tug). 5) The reliability of repeated measure tympanic temperature was better than without ear tug. With above results, we can't determine the optimal and cilically significant oral and axillary measuring time using mercury thermometer. However, because the real differences between measuring times were very small, so we recommend further study for the aged, the infants and the febrile patients. And we can't sure the accuracy of tympanic temperature but the reliability was better with ear tug than without ear tug.

  • PDF

수술전과 수술중 피부가온요법 적응이 고관절 전치환술 환자의 수술 주기 고막체온 변화에 미치는 영향 (The Effect of Pre and Intra-Operative Warming Therapy on Tympanic Temperature Changes during Perioperative Phase in Receiving Patients with Total Hip Replacement)

  • 권영숙;김은희
    • 기본간호학회지
    • /
    • 제7권1호
    • /
    • pp.86-96
    • /
    • 2000
  • The purpose of the study was to investigate the effects of Warming Therapy used with patients consistantly before and during surgery to on changes in their body temperatures. The data were collected from patients in a university hospital in Taegu between December 1, 1998 and May 31, 1999. The subjects were selected from patients who were hospitalized for total hip replacement surgery. Thirty participants were assigned to two groups : experimental(Warming Therapy) group and control group. Each group consisted of 15 patients. The research design was a repeated measurement design, using a nonequivalent control group. The Warming Therapy, using a forced-air warming blanket, that is a, 'Bair Hugger' was applied to subjects in the experimental group. The subjects in the group were treated with the 'Bair Hugger' to warm up the whole body for 40 minutes before surgery and upper body and face during the operation. The core temperature was measured using a tympanic thermometer. The body temperature of the patients was measured 13 times every 15 minutes during the surgery. After the operation the body temperature of the patients was measured 4 times every 15 minutes, from the time of arrivial in the recovery room to the time of leaving the recovery room. The SPSS Win 9.0 program was used for data analysis. Specific methods tested were done using ${\chi}^2-test$, t-test, repeated measures ANOVA. The findings of the study are as follows. 1. The first hypothesis, 'The level of tympanic temperature for the experimental group which received Warming Therapy will be higher than that of the control group during the operation', was supported (F=32.16, p=.000). 2. The second hypothesis, 'The level of tympanic temperature for the experimental group which received Warming Therapy will be higher than that of the control group after the operation', was supported.(F=33.36, p=.000) 3. During recovery, shivering was observed one patient in the experimental group and seven patients in the control group. In summary, the findings of the study suggest that the 'Warming Therapy' applied before and during the surgery was a very effective treatment for surgical patients in maintaining the core temperature during surgery

  • PDF

측정부위별 신생아의 체온 비교 : 고막기준 직장체온, 직장체온, 액와체온, 복부체온 (Comparison by Measurement Sites in Temperature of Neonates : Ear-based rectal, Rectal, Axilla, Abdominal Temperature)

  • 김화순;안영미
    • 대한간호학회지
    • /
    • 제29권4호
    • /
    • pp.903-916
    • /
    • 1999
  • The purpose of this study was to compare the ear-based rectal temperature measured with a tympanic thermometer with the rectal temperature measured with a glass mercury thermometer in order to test the accuracy of tympanic thermometer and to determine relationship among rectal, axilla, and abdominal temperature in neonates. The samples consisted of thirty four neonates admitted to the neonatal intensive care unit and nursery at an university affiliated hospital. The mean age of the subjects was 4.9 days. The ear-based rectal temperatures were taken with a tympanic thermometer in rectal mode (First Temp Genius 3000). Rectal and axilla temperatures were taken with a glass mercury thermometer, Abdominal temperature was continuously monitored with the probe connected to the servo controller of incubator. The results of the study can be summarized as follows : 1. Intrarater comparison : Agreement between the first and the second ear-based rectal temperature was 97% within 0.1$^{\circ}C$. 2. Comparison of ear-based rectal temperature and the rectal temperature from a glass mercury thermometer : ear-based rectal temperature ranged from 36.95$^{\circ}C$d to 37.95$^{\circ}C$, with a mean of 37.58$^{\circ}C$(SD=0.22$^{\circ}C$). Rectal temperature from a glass mercury thermometer ranged from 36.2$0^{\circ}C$ to 37.2$0^{\circ}C$, with a mean 36.75$^{\circ}C$(SD=0.29). The mean difference between both temperatures was 0.84$^{\circ}C$. The correlation coefficient between both temperatures was r=0.77(p=0.00). 3. Comparison of rectal and axilla temperature : Axilla temperature ranged from 35.8$0^{\circ}C$ to 37.1$0^{\circ}C$, with a mean of 36.55$^{\circ}C$. The mean absolute difference between the rectal and axilla temperature was 0.23$^{\circ}C$. The correlation coefficient between rectal and axilla was r=0.67. 4. Comparison of axilla and abdominal temperature : Abdominal temperature ranged from 36.2$0^{\circ}C$ to 37.0$0^{\circ}C$, with a mean of 36.58$^{\circ}C$. The mean absolute difference between axilla and abdominal temperature was only -0.03$^{\circ}C$. Findings of this study suggest that ear-based rectal temperature overestimates the actual rectal temperatures in neonates. Therefore, the interchangeble use of both temperatures in clinics seems problematic. The site offset(adjustment value) programmed in rectal mode of the tympanic thermometer needs to be readjusted. Choosing one optimal site for temperature measurement for each patient, and using the specific site consistently would result in more consistent measurements of changes in body temperature, and thus can be more effective in diagnosing fever or hypothermia.

  • PDF