• Title/Summary/Keyword: two-time-scale system

Search Result 439, Processing Time 0.028 seconds

The First Crustal Refraction Survey in the Korean Peninsula

  • Jung Mo Lee;Wooil Moon;Chang-Eob Baag;Heeok Jung;Ki Young Kim;Bong Gon Jo;Woohan Kim;Sung Kyun Kim
    • Proceedings of the International Union of Geodesy And Geophysics Korea Journal of Geophysical Research Conference
    • /
    • 2003.05a
    • /
    • pp.15-15
    • /
    • 2003
  • The first crustal refraction survey in the Korean Peninsula was carried out over the survey line connecting Seosan-Yeongdong-Kyeongiu on Dec. 15, 2002. The total length of the survey line was about 300 Km and 198 portable seismometers were deployed with approximately 1.5-km interval. The survey line itself was geologically important since it was almost normal to the so-called Sino-Korean structural trend. Two shots, one at Seosan (west end point) and the other at Yeongdong (mid-point), were exploded. They were 100-m deep drill well explosions. The Seosan shot consisted of a ton emulsion type explosive, while Youngdong consisted of 500 kg one. Both shots generated signals with good S/N ratios to the farthest receivers. Seismic signals were recorded by 195 receivers out of 198 ones. Although the originally planned Kyeongju shot (east end point) could not be exploded due to public discontent, the experiment was evaluated very successful. First breaks in all recorded traces were picked up and two preliminary analyses were carried out. The one is conventional flat layer analysis and the other was refraction tomographic analysis. The one resulted in average 32-km thick two-layer crust and the underlying mantle with 8.05-km/s P-velocity. The top crust layer with 3.86 kw/s P-velocity was 2.5-km thick and the lower crust layer with 6.0l km/s P-velocity was 29.5-km thick. The other resulted in a velocity cross-section. The confidence level of the velocity cross-section could not be evaluated at this time because only two shot were exploded. Detailed analyses such as surface wave dispersion are on going. Continuing crustal scale refraction surveys are planned in Korea.

  • PDF

An Assessment of Environmental Characteristics Associated with the Level of Endotoxin Concentration in Hospital Lobbies (일부 종합 병원 로비의 공기 중 엔도톡신 농도에 미치는 환경 요인 평가)

  • Lee, Kyeong-Min;Yeom, Jeongkwan;Lee, Wonjae;Ryu, Seung-Hun;Park, Dongjin;Park, Dong-Uk
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.3
    • /
    • pp.310-320
    • /
    • 2014
  • Backgrounds: Endotoxin, which found in the outer membrane of the gram-negative bacteria cell wall, makes up almost all of the lipopolysaccharide(LPS). When people are exposed to endotoxin,it can result in diverse health effects such as an airway irritation and inflammation, fever, malaise, bronchitis, allergic asthma, toxic pneumonitis, hypersensitivity lung disease. Cases among the elderly, children or pregnant can occur more frequently than a healthy adult if they are repeatedly exposed to the existing endotoxin. Therefore, we investigated and assessed the environmental characteristics associated with the airborne endotoxin concentration level in six hospital lobbies. Method: Endotoxin from indoor air in six hospital lobbies was measured by an area sampling method and analyzed according to American Society for Testing and Materials International(ASTM international) E2144-01. Total suspended particulate(TSP), carbon dioxide($CO_2$), temperature and humidity were also measured by using direct reading measurements or airborne sampling equipment at the same time. Environmental characteristics were appropriately divided into two or three groups for a statistics analysis. One-way analysis variable(one-way ANOVA) was used to examine a difference of the endotoxin concentration, depending on the environmental characteristics. In addition, only variables with p-value(p<0.25) were eventually designed to the best model by using multiple regression analysis. Results: The correlation analysis result indicated that TSP(p=0.003) and $CO_2$(p<0.0001) levels were significantly associated with endotoxin concentration levels. In contrast, temperature(p<0.068) and humidity(p<0.365) were not associated with endotoxin concentration. Levels of endotoxin concentration were statistically different among the environmental characteristics of Service time(p=0.01), Establishment of hospital(p<0.001), Scale of hospital(p=0.01), Day average people using hospital(p=0.03), Cleaning time of lobby(p=0.05), Season(p<0.001), and Cleaning of ventilation system(p<0.001) according to ANOVA. Finally, the best model(Adjusted R-square=72%) that we designed through a multiple regression test included environmental characteristics related to Service time, Area of lobby, Season, Cleaning of ventilation system, and Temperature. Conclusions: According to this study, our result showed a normal level of endotoxin concentration in the hospital lobbies and found environmental management methods to reduce the level of endotoxin concentration to a minimum. Consequently, this study recognized to be requirement for the management of ventilation systems and an indoor temperature in order to reduce the level of endotoxin concentration in the hospital lobbies.

An Initial Study on the Reliability Assurance in PET/CT Standardized Uptake Values (PET/CT 에서 표준섭취계수(SUV)의 신뢰성 확보를 위한 초기연구)

  • Park, Hoon-Hee;Kim, Jung-Yul;Lee, Seung-Jae;Park, Min-Soo;NamKoong, Hyuk;Lim, Han-Sang;Oh, Ki-Baek;Kim, Jae-Sam;Lee, Chang-Ho;Jin, Gye-Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.31-42
    • /
    • 2009
  • Purpose: As the number of domestic medical institutions installing PET/CT is increasing rapidly, the transfer of PET/CT images among medical institutions is also increasing. Thus, it is necessary to collect the comparative SUV data from several medical institutions' PET/CT systems through a phantom study which semi-quantitatively compares the SUV on one bed, the change scale of the SUV on the slices, and the time of measuring. The phantom study to find differences among the SUVs from various PET/CT offers the opportunity to obtain the reliability of the SUV in PET/CT images. Materials and Methods: Ten PET/CT systems from medical institutions in Korea were used. To obtain the accurate data, the study has been using the radiation detector of Korea Research Institute of Standards and Science to verify. The internal structures of NEMA $phantom^{TM}$ were removed and Six thousand milliliters of distilled water which has 1mCi of $^{18}F$-FDG put into the phantom. The water was properly integrated with $^{18}F$-FDG using magnetic stirrer. The images were acquired at 60, 70, 80, 90, 100, 110 and 120-minutes for 3 minute each. Two hundred square centimeters of region of interests were placed and analyzed. To confirm the usefulness, the correction-table came out from patients' data. Results: The coefficient of variability of the SUV from -11.0 to 9.90 % fell into the range of international standards(${\pm}10%$) along with the SUV on a bed, the change scale of the SUV on the slices, and the time of measuring, except one PET/CT system. Using the data of the differences among the SUVs, we came to withdraw the correction-table ranging from 0.803 to 1.246. The correction-table was confirmed its usefulness through Linear Regression Analysis which was applied to normal cases. Conclusions: Although studies have been made on the variation of the SUV, there is little attention on the standardization of the SUV. Based on this study of the quantitatively comparable data about the SUV accommodating the correction-table, it would help to have more corrective diagnosis.

  • PDF

A Study on Link Travel Time Prediction by Short Term Simulation Based on CA (CA모형을 이용한 단기 구간통행시간 예측에 관한 연구)

  • 이승재;장현호
    • Journal of Korean Society of Transportation
    • /
    • v.21 no.1
    • /
    • pp.91-102
    • /
    • 2003
  • There are two goals in this paper. The one is development of existing CA(Cellular Automata) model to explain more realistic deceleration process to stop. The other is the application of the updated CA model to forecasting simulation to predict short term link travel time that takes a key rule in finding the shortest path of route guidance system of ITS. Car following theory of CA models don't makes not response to leading vehicle's velocity but gap or distance between leading vehicles and following vehicles. So a following vehicle running at free flow speed must meet steeply sudden deceleration to avoid back collision within unrealistic braking distance. To tackle above unrealistic deceleration rule, “Slow-to-stop” rule is integrated into NaSch model. For application to interrupted traffic flow, this paper applies “Slow-to-stop” rule to both normal traffic light and random traffic light. And vehicle packet method is used to simulate a large-scale network on the desktop. Generally, time series data analysis methods such as neural network, ARIMA, and Kalman filtering are used for short term link travel time prediction that is crucial to find an optimal dynamic shortest path. But those methods have time-lag problems and are hard to capture traffic flow mechanism such as spill over and spill back etc. To address above problems. the CA model built in this study is used for forecasting simulation to predict short term link travel time in Kangnam district network And it's turned out that short term prediction simulation method generates novel results, taking a crack of time lag problems and considering interrupted traffic flow mechanism.

Posterior Microscopic Lesionectomy for Lumbar Disc Herniation with Tubular Retraction Using $METRx^{TM}$ System

  • Choi, Yu-Yeol;Yoon, Seung-Hwan;Ha, Yoon;Kim, Eun-Young;Park, Hyung-Chun;Park, Chong-Oon
    • Journal of Korean Neurosurgical Society
    • /
    • v.40 no.6
    • /
    • pp.406-411
    • /
    • 2006
  • Objective : The authors have developed a procedure, termed posterior microscopic lesionectomy, that creates a minimal laminotomy site according to the location of the shifted disc using the $METRx^{TM}$ system in the lumbar spine. This study compared the usefulness and surgical outcomes of this procedure with those of traditional standard lumbar discectomy. Methods : From June 2003 to June 2004, Twenty-two patients with one-level radiculopathy due to lumbar disc herniation underwent posterior microscopic lesionectomy with the assistance of an operating microscope and the $METRx^{TM}$ tubular retractor. Surgical results of the new procedure were compared to those of 39 patients who underwent traditional lumbar discectomy from April 2003 to September 2004. All patients were evaluated for pain score, clinical assessment according to the VAS, and Roland-Morris scores pre-operatively and at 1, 3, 6, and 12 months post-operatively. Results : Mean blood loss, operation time, and admission date showed significant improvements for microscopic lesionectomy compared to traditional lumbar discectomy [P < 0.001]. Also, both measures of short-term functional improvement, the Visual Analogue Scale[VAS] and Roland-Morris[RM] scores, were statistically better for microscopic lesionectomy than for traditional discectomy [P < 0.001]. Conclusion : Posterior microscopic lesionectomy can be performed more safely and provide greater benefit than traditional discectomy. The procedure is associated with less post-operative pain, shorter hospital stays, and quicker rehabilitation.

Application of ozone treatment in cooling water systems for energy and chemical conservation

  • Ataei, Abtin;Mirsaeed, Morteza Ghazi;Choi, Jun-Ki;Lashkarboluki, Reza
    • Advances in environmental research
    • /
    • v.4 no.3
    • /
    • pp.155-172
    • /
    • 2015
  • In this study, a complete set of recirculating cooling water system and the required instruments were built in a semi-industrial-scale and a 50 g/h ozone generation plant and a chlorine system were designed for cooling water treatment. Both chlorination and ozonation treatment methods were studied and the results were analyzed during two 45-days periods. The concentrations of ozone and chlorine in recirculating water were constant at 0.1 mg/lit and 0.6 mg/lit, respectively. In ozone treatment, by increasing the concentration cycle to 33%, the total water consumption decreased by 26% while 11.5% higher energy efficiency achieved thanks to a better elimination of bio-films. In case of Carbon Steel, the corrosion rate reached to 0.012 mm/yr and 0.025 mm/yr for the ozonation and chlorination processes, respectively. Furthermore, consumptions of the anti-corrosion and anti-sedimentation materials in the ozone cooling water treatment were reduced about 60% without using any oxidant and non-oxidant biocides. No significant changes in sediment load were seen in ozonation compared to chlorination. The Chemical Oxygen Demand of the blow-down in ozonation method decreased to one-sixth of that in the chlorination method. Moreover, the soluble iron and water turbidity in the ozonation method were reduced by 97.5% and 70%, respectively. Although no anaerobic bacteria were seen in the cooling water at the proper concentration range of ozone and chlorine, the aerobic bacteria in chlorine and ozone treatment methods were 900 and 200 CFU/ml, respectively. The results showed that the payback time for the ozone treatment is about 2.6 years.

An Enhanced Floor Field based Pedestrian Simulation Model (개선된 Floor Field 기반 보행 시뮬레이션 모델)

  • Jun, Chul-Min
    • Journal of Korea Spatial Information System Society
    • /
    • v.12 no.1
    • /
    • pp.76-84
    • /
    • 2010
  • Many pedestrian simulation models for micro-scale spaces as building indoor areas have been proposed for the last decade and two models - social force model and floor field model - are getting attention. Among these, CA-based floor field model is viewed more favourable for computer simulations than computationally complex social force model. However, Kirchner's floor field model has limitations in capturing the differences in dynamic values of different agents and this study proposes an enhanced algorithm. This study improved the floor field model in order for an agent to be able to exclude the influences of its own dynamic values by changing the data structure, and, also modified the initial dynamic value problem in order to fit more realistic environment. In the simulations, real 3D building data stored in a spatial DBMS were used considering future integration with indoor localization sensors and real time applications.

Collisionless Magnetic Reconnection and Dynamo Processes in a Spatially Rotating Magnetic Field

  • Lee, Junggi;Choe, G.S.;Song, Inhyeok
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.41 no.1
    • /
    • pp.45.1-45.1
    • /
    • 2016
  • Spatially rotating magnetic fields have been observed in the solar wind and in the Earth's magnetopause as well as in reversed field pinch (RFP) devices. Such field configurations have a similarity with extended current layers having a spatially varying plasma pressure instead of the spatially varying guide field. It is thus expected that magnetic reconnection may take place in a rotating magnetic field no less than in an extended current layer. We have investigated the spontaneous evolution of a collisionless plasma system embedding a rotating magnetic field with a two-and-a-half-dimensional electromagnetic particle-in-cell (PIC) simulation. In magnetohydrodynamics, magnetic flux can be decreased by diffusion in O-lines. In kinetic physics, however, an asymmetry of the velocity distribution function can generate new magnetic flux near O- and X-lines, hence a dynamo effect. We have found that a magnetic-flux-reducing diffusion phase and a magnetic-flux-increasing dynamo phase are alternating with a certain period. The temperature of the system also varies with the same period, showing a similarity to sawtooth oscillations in tokamaks. We have shown that a modified theory of sawtooth oscillations can explain the periodic behavior observed in the simulation. A strong guide field distorts the current layer as was observed in laboratory experiments. This distortion is smoothed out as magnetic islands fade away by the O-line diffusion, but is soon strengthened by the growth of magnetic islands. These processes are all repeating with a fixed period. Our results suggest that a rotating magnetic field configuration continuously undergoes deformation and relaxation in a short time-scale although it might look rather steady in a long-term view.

  • PDF

Multiple-Point-Diffraction Interferometer : Error Analysis and Calibration (거친 표면 형상측정을 위한 점광원 절대간섭계의 오차해석과 시스템 변수의 보)

  • Kim, Byoung-Chang;Kim, Seung-Woo
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.4
    • /
    • pp.361-365
    • /
    • 2005
  • An absolute interferometer system with multiple point-sources is devised for tile 3-D measurement of rough surface profiles. The positions of the point sources are determined to be the system parameters that influence the measurement accuracy, so they are calibrated precisely prior to performing actual measurements. For the calibration, a CCD camera composed of a two-dimensional array of photo-detectors was used. Performing optimization of the cost function constructed with phase values measured at each pixel on the CCD camera, the position coordinates of each point source is precisely determined. Measurement results after calibration performed for the warpage inspection of chip scale packages (CSPs) demonstrate that the maximum discrepancy is 9.8 mm with a standard deviation o( 1.5 mm in comparison with the test results obtained by using a Form Taly Surf instrument.

Four-valued Hybrid FFT processor design using current mode CMOS (전류 모드 CMOS를 이용한 4치 Hybrid FFT 연산기 설계)

  • 서명웅;송홍복
    • Journal of the Korea Computer Industry Society
    • /
    • v.3 no.1
    • /
    • pp.57-66
    • /
    • 2002
  • In this study, Multi-Values Logic processor was designed using the basic circuit of the electric current mode CMOS. First of all, binary FFT(Fast Fourier Transform) was extended and high-speed Multi-Valued Logic processor was constructed using a multi-valued logic circuit. Compared with the existing two-valued FFT, the FFT operation can reduce the number of transistors significantly and show the simplicity of the circuit. Moreover, for the construction of amount was used inside the FFT circuit with the set of redundant numbers like [0,1,2,3]. As a result, the defects in lines were reduced and it turned out to be effective in the aspect of normality an regularity when it was used designing VLSI(Very Large Scale Integration). To multiply FFT, the time and size of the operation was used as LUT(Look Up Table) Finally, for the compatibility with the binary system, multiple-valued hybrid-type FFT processor was proposed and designed using binary-four valued encoder, four-binary valued decoder, and the electric current mode CMOS circuit.

  • PDF