• Title/Summary/Keyword: two-temperature model

Search Result 1,879, Processing Time 0.027 seconds

Numerical simulation of non-isothermal flow in oil reservoirs using a two-equation model

  • dos Santos Heringer, Juan Diego;de Souza Debossam, Joao Gabriel;de Souza, Grazione;Souto, Helio Pedro Amaral
    • Coupled systems mechanics
    • /
    • v.8 no.2
    • /
    • pp.147-168
    • /
    • 2019
  • This work aims to simulate three-dimensional heavy oil flow in a reservoir with heater-wells. Mass, momentum and energy balances, as well as correlations for rock and fluid properties, are used to obtain non-linear partial differential equations for the fluid pressure and temperature, and for the rock temperature. Heat transfer is simulated using a two-equation model that is more appropriate when fluid and rock have very different thermal properties, and we also perform comparisons between one- and two-equation models. The governing equations are discretized using the Finite Volume Method. For the numerical solution, we apply a linearization and an operator splitting. As a consequence, three algebraic subsystems of linearized equations are solved using the Conjugate Gradient Method. The results obtained show the suitability of the numerical method and the technical feasibility of heating the reservoir with static equipment.

THEORITICALL ANALYSIS OF TEMPERATURE DISTRIBUTION IN TWO-DIMENSIONAL FIELD USING F.E.M (유한요소법을 이용한 2차원 Field 내의 온도분포의 이론적 해석)

  • Kim, N.H.;Choi, C.S.;Choi, H.H.;Hong, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 1987.07b
    • /
    • pp.1292-1295
    • /
    • 1987
  • In noninvasive temperature measurement within body, this paper is presented temperature measurement method in security and with effect from Applicator by electromagnetic, and it is analyzed heat generation quantity or temperature rise distribution by computer simulation within body. In this paper, two-dimensional model is considered and temperature distribution produced by RF capacitive heating system is analyzed by using Finit Element Method (F.E.M). A passibility of temperature distribution control is examined based on the position and size of Applicator.

  • PDF

SPECTRAL LINE-DEPTH RATIO AS A PRECISE EFFECTIVE TEMPERATURE AND SURFACE GRAVITY INDICATOR FOR WARM STARS

  • Kim, Chul-Hee
    • Journal of The Korean Astronomical Society
    • /
    • v.39 no.4
    • /
    • pp.125-128
    • /
    • 2006
  • In order to determine the precise effective temperature and surface gravity of warm stars, all synthetic spectral lines in the wavelength range of $4000-5700{\AA}$ with T=6000-7750 K, and log g=3.5, 4.0, and 4.5 for [M/H]=0.0, $V_{rot}$=10 km $s^{-1}$, and $V_{tubl}$=2 km $s^{-1}$ were calculated using the SYNSPEC package(Hubeny, et al., 1995) and the Kurucz(1995) model. Then, the depth-ratios for all line pairs were investigated and we selected two and six depth-ratios appropriate for the surface gravity and temperature indicators, respectively. We plotted six grids with X- and Y-axes for the depth-ratios of surface gravity and temperature, respectively, for the simultaneous estimation of these two atmospheric parameters. This method was applied to the spectum of $\delta$ Scu for the determination of its temperature and surface gravity simultaneously.

Thermo-mechanical behavior of prestressed concrete box girder at hydration age

  • Zhang, Gang;Zhu, Meichun;He, Shuanhai;Hou, Wei
    • Computers and Concrete
    • /
    • v.20 no.5
    • /
    • pp.529-537
    • /
    • 2017
  • Excessively elevated temperature can lead to cracks in prestressed concrete (PC) continuous bridge with box girder on the pier top at cement hydration age. This paper presents a case study for evaluating the behavior of PC box girder during the early hydration age using a two-stage computational model, in the form of computer program ANSYS, namely, 3-D temperature evaluation and determination of mechanical response in PC box girders. A numerical model considering time-dependent wind speed and ambient temperature in ANSYS for tracing the thermal and mechanical response of box girder is developed. The predicted results were compared to show good agreement with the measured data from the PC box girder of the Zhaoshi Bridge in China. Then, based on the validated numerical model three parameters were incorporated to analyze the evolution of the temperature and stress within box girder caused by cement hydration heat. The results of case study indicate that the wind speed can change the degradation history of temperature and stress and reduce peak value of them. The initial casting temperature of concrete is the most significant parameter which controls cracking of PC box girder on pier top at cement hydration age. Increasing the curing temperature is detrimental to prevent cracking.

The Relationships between Temperature Changes and Mortality in Seoul, Korea (서울시의 기온변화와 사망자수 간의 관련성 연구)

  • Lee, Sa-Ra;Kim, Ho;Yi, Seung-Muk
    • Journal of Environmental Health Sciences
    • /
    • v.36 no.1
    • /
    • pp.20-26
    • /
    • 2010
  • Temperature change has been shown to affect daily mortality even though different analytical methods produce different results. The effect of air pollution on the relationship between the temperature and the mortality is not large, although differences exist between temperature models. The aim of this study was to examine how the temperature change affected the daily mortality in Seoul by comparing the results from the temperature model using two study periods: one from 1994 to 2007 and the other from 1997 to 2007. Generally mean temperature, minimum temperature and Q10 temperature was derived as an optimal model, even though there are differences between age and cause of death. The analysis of threshold using total mortalities in all ages from 1994 to 2007 and from 1997 to 2007 showed that the number of the deaths increased 7.02% (95% CI: 6.06~7.98) and 2.51% (95% CI: 1.83~3.19), respectively as the mean temperature increased $1^{\circ}C$ from a threshold temperature of $27.5^{\circ}C$ and $25.7^{\circ}C$ respectively. These results indicated that the temperature has less effect on the number of death than does an extreme heat wave period.

An experimental and numerical study on temperature gradient and thermal stress of CFST truss girders under solar radiation

  • Peng, Guihan;Nakamura, Shozo;Zhu, Xinqun;Wu, Qingxiong;Wang, Hailiang
    • Computers and Concrete
    • /
    • v.20 no.5
    • /
    • pp.605-616
    • /
    • 2017
  • Concrete filled steel tubular (CFST) composite girder is a new type of structures for bridge constructions. The existing design codes cannot be used to predict the thermal stress in the CFST truss girder structures under solar radiation. This study is to develop the temperature gradient curves for predicting thermal stress of the structure based on field and laboratory monitoring data. An in-field testing had been carried out on Ganhaizi Bridge for over two months. Thermal couples were installed at the cross section of the CFST truss girder and the continuous data was collected every 30 minutes. A typical temperature gradient mode was then extracted by comparing temperature distributions at different times. To further verify the temperature gradient mode and investigate the evolution of temperature fields, an outdoor experiment was conducted on a 1:8 scale bridge model, which was installed with both thermal couples and strain gauges. The main factors including solar radiation and ambient temperature on the different positions were studied. Laboratory results were consistent with that from the in-field data and temperature gradient curves were obtained from the in-field and laboratory data. The relationship between the strain difference at top and bottom surfaces of the concrete deck and its corresponding temperature change was also obtained and a method based on curve fitting was proposed to predict the thermal strain under elevated temperature. The thermal stress model for CFST composite girder was derived. By the proposed model, the thermal stress was obtained from the temperature gradient curves. The results using the proposed model were agreed well with that by finite element modelling.

Evaluation of the heat island in transition zone of three cities in Kyungpook, Korea (추이대(推移帶)를 중심으로 한 경상북도 3개 도시의 열섬 평가)

  • Park, In Hwan;Jang, Gab Sue;Kim, Jong Yong
    • Journal of Environmental Impact Assessment
    • /
    • v.8 no.2
    • /
    • pp.73-82
    • /
    • 1999
  • This study analyzed the relationship between NDVI(Normalized Difference Vegetation Index) and urban heat island in three cities: Daegu, Kyungju, and Pohang for understanding the degree of nature conservation concentrating in the transition zone of them. Daegu city is the third city in Korea which has a dense population. Kyungju is a traditional city which has good nature. Pohang is an industrial city which has those of characters of Daegu and Kyungju. Landsat 1M data in May 17, 1997 were used for the analysis of heat island. There were about four theoretical models to estimate the surface temperature from TM data: Two-point linear model, Linear regression model, Quadratic regression model, and Cubic regression model. In this study, Linear regression model had been utilized to analyze the urban heat island. On the resultant images, the transition zone of Daegu was urbanized more extremely than those of other two cities. It is thought that the analysis of relationship between NDVI and surface temperature, used in this study, is regarded as one of effective methodologies for urban-environmental detection from satellite imageries.

  • PDF

NEAR-WALL GRID DEPENDENCY OF CFD SIMULATION FOR A SUBCOOLED BOILING FLOW USING WALL BOILING MODEL (벽 비등모델을 이용한 과냉비등 유동에 대한 CFD 모의계산에서 벽 인접격자의 영향)

  • In, W.K.;Shin, C.H.;Chun, T.H.
    • Journal of computational fluids engineering
    • /
    • v.15 no.3
    • /
    • pp.24-31
    • /
    • 2010
  • boiling flow in vertical tube. The multiphase flow model used in this CFD analysis is the two-fluid model in which liquid(water) and gas(vapour) are considered as continuous and dispersed fluids, respectively. A wall boiling model is also used to simulate the subcooled boiling heat transfer at the heated wall boundary. The diameter and heated length of tube are 0.0154 m and 2 m, respectively. The system pressure in tube is 4.5 MPa and the inlet subcooling is 60 K. The near-wall grid size in the non-dimensional wall unit for lqiuid phase ($y^+_{w,l}$) was examined from 101 to 313 at the outlet boundary. The CFD calculations predicted the void distributions as well as the liquid and wall temperatures in tube. The predicted axial variations of the void fraction and the wall temperature are compared with the measured ones. The CFD prediction of the wall temperature is shown to slightly depend on the near-wall grid size but the axial void prediction has somewhat large dependency. The CFD prediction was found to show a better agreement with the measured one for the large near-wall grid, e.g., $y^+_{w,l}$ > 300 at the tube exit.

Nonlinear vibration of functionally graded nano-tubes using nonlocal strain gradient theory and a two-steps perturbation method

  • Gao, Yang;Xiao, Wan-Shen;Zhu, Haiping
    • Structural Engineering and Mechanics
    • /
    • v.69 no.2
    • /
    • pp.205-219
    • /
    • 2019
  • This paper analyzes nonlinear free vibration of the circular nano-tubes made of functionally graded materials in the framework of nonlocal strain gradient theory in conjunction with a refined higher order shear deformation beam model. The effective material properties of the tube related to the change of temperature are assumed to vary along the radius of tube based on the power law. The refined beam model is introduced which not only contains transverse shear deformation but also satisfies the stress boundary conditions where shear stress cancels each other out on the inner and outer surfaces. Moreover, it can degenerate the Euler beam model, the Timoshenko beam model and the Reddy beam model. By incorporating this model with Hamilton's principle, the nonlinear vibration equations are established. The equations, including a material length scale parameter as well as a nonlocal parameter, can describe the size-dependent in linear and nonlinear vibration of FGM nanotubes. Analytical solution is obtained by using a two-steps perturbation method. Several comparisons are performed to validate the present analysis. Eventually, the effects of various physical parameters on nonlinear and linear natural frequencies of FGM nanotubes are analyzed, such as inner radius, temperature, nonlocal parameter, strain gradient parameter, scale parameter ratio, slenderness ratio, volume indexes, different beam models.

Effects of Climate Change on the Occurrence of Two Fly Families (Phoridae and Lauxaniidae) in Korean Forests

  • Kwon, Tae-Sung;Lee, Cheol Min;Jie, Okyoung;Kim, Sung-Soo;Jung, Sungcheol;Park, Young-Seuk
    • Korean Journal of Ecology and Environment
    • /
    • v.54 no.1
    • /
    • pp.71-77
    • /
    • 2021
  • Using data from flies collected with pitfall traps in 365 forests on a nationwide scale in Korea, the abundance and distribution changes of two families (Phoridae and Lauxaniidae) in Korean forests were predicted at the genus level according to two climate change scenarios: RCP 4.5 and RCP 8.5. The most suitable temperature for the 17 major genera was estimated using a weighted average regression model. Stichillus and Anevrina displayed the lowest optimum temperature with 7.6℃ and 8.5℃ in annual mean temperature, respectively, whereas Chonocephalus had the highest optimum temperature with 12.1℃. Among thirty genera, seven genera (four from Phoridae and three from Lauxaniidae), which showed their abundance in a bell-type or linear pattern along the temperature gradient, were used for predicting the distribution changes according to the future climate change scenarios. All the taxa of this study are expected to decrease in abundance and distribution as a function of temperature increase. Moreover, cold-adapted taxa were found to be more affected than warm-adapted taxa.