• Title/Summary/Keyword: two-story roof structure

Search Result 14, Processing Time 0.021 seconds

A Study on the Pingzuo Structure of the Two-Story Building with One Roof in the Early Period of Tang Dynasty (당 전기 단첨누각의 평좌 구조 연구)

  • Baik, So-Hun
    • Journal of architectural history
    • /
    • v.30 no.3
    • /
    • pp.21-31
    • /
    • 2021
  • This paper studied the Pingzuo(平坐) platform structure of the two story building covered with one roof during the early period of Tang dynasty, based on wall paintings, stone pagodas, brick buildings and wooden buildings might be influenced by the Tang style. Instead of Chazhuzao(叉柱造), the typical column linkage in the Song, Liao and Jin buildings, it put the boundary column just behind the wall of a bracket set. Otherwise, the column root might be seen from outside, because its bracket set was still using Touxinzao(偸心造) which did not have a lateral arm on it. And its flooring structure was also different from the Song style, it used cantilever beams instead of lateral beams supported by bracket sets.

Effect of shear wall location in rigid frame on earthquake response of roof structure

  • Ishikawa, Koichiro;Kawasaki, Yoshizo;Tagawa, Kengo
    • Structural Engineering and Mechanics
    • /
    • v.11 no.6
    • /
    • pp.605-616
    • /
    • 2001
  • The purpose of this study is to investigate the effect of the shear wall location in rigid frames on the dynamic behavior of a roof structure due to vertical and horizontal earthquake motions. The study deals with a gabled long span beam supported by two story rigid frames with shear walls. The earthquake response analysis is carried out to study the responses of the roof: vibration mode, natural period, bending moment and horizontal shear force of the bearings. The study results in the following conclusions: First, a large horizontal stiffness difference between the side frames is caused by the shear wall location, which results in a large vertical vibration of the roof and a large shear force at the side bearings. Second, in this case, the seismic design method for ordinary buildings is not useful in determining the distribution of the static equivalent loads for the seismic design of this kind of long span structures.

Characteristics of the Newly Developed Rain Shelter for Grapevine and Growth of 'Campbell Early' (신개발 포도 비가림 시설의 특성과 '캠벌얼리'의 생육)

  • Lee, Yun Sang;Kim, Seung Deok;Lee, Seok Ho;Hong, Seong Taek;Lee, Jae Wung;Hong, Eui Yon;Kim, Dae Il
    • Journal of Bio-Environment Control
    • /
    • v.24 no.3
    • /
    • pp.252-257
    • /
    • 2015
  • Fruit cracking and vine leaf spot of grapes tend to occur when the plants were directly exposed to rain under outdoor culture. Rain shelter facility can be an alternative method to prevent the cracking and disease of grape, but it also has some limitations in practical usages. We designed rain shelter facility which can completely shut out the rain and ventilate naturally, and it was upgraded to meet the standards of disaster prevention against snow and wind load. The newly developed rain shelter has two-story roof structure, and the $2^{nd}$ floor roof was equipped over $1^{st}$ floor roof at a distance of 40cm. For natural ventilation and water proof, the upper roof protruded about 50cm from the ridge of a $1^{st}$ floor roof. The various tests were carried to examine such as grape quality, brown spot and fruit cracking of Campbell Early under the conventional and the newly developed rain shelter facility which was built about $100{\ss}{\check{S}}$. In comparison of temperature between the conventional and the newly developed rain shelter facility when outside temperature was more than $34^{\circ}C$, the inside temperature was recorded as $40.7^{\circ}C$ and $37.4^{\circ}C$, respectively. There was no significant difference between the two facilities when outside was below $32^{\circ}C$ The quality such as soluble solids and marketable fruit was increased, and fruit cracking of grapes and vine leaf spot also drastically diminished in the newly developed rain shelter.

Elasto-plastic time history analysis of a 117-story high structure

  • Wu, Xiaohan;Li, Yimiao;Zhang, Yunlei
    • Computers and Concrete
    • /
    • v.19 no.1
    • /
    • pp.7-17
    • /
    • 2017
  • In Chinese Design Codes, for super high-rise buildings with complex structural distribution, which are regarded as code-exceeding buildings, elasto-plastic time history analysis is needed to validate the requirement of "no collapse under rare earthquake". In this paper, a 117-story super high-rise building is discussed. It has a height of 597 m and a height-width ratio of 9.5, which have both exceeded the limitations stipulated by the Chinese Design Codes. Mega columns adopted in this structure have cross section area of about $45m^2$ at the bottom, which is infrequent in practical projects. NosaCAD and Perform-3D, both widely used in nonlinear analyses, were chosen in this study, with which two model were established and analyzed, respectively. Elasto-plastic time history analysis was conducted to look into its seismic behavior, emphasizing on the stress state and deformation abilities under intensive seismic excitation.From the comparisons on the results under rare earthquake obtained from NosaCAD and Perform-3D, the overall responses such as roof displacement, inter story drift, base shear and damage pattern of the whole structure from each software show agreement to an extent. Besides, the deformation of the structure is below the limitation of the Chinese Codes, the time sequence and distribution of damages on core tubes are reasonable, and can dissipate certain inputted energy, which indicates that the structure can meet the requirement of "no collapse under rare earthquake".

Conceptual Application Schemes of Seismic Isolation Techniques to Hanok (한옥의 면진기법 적용 방안에 대한 개념적 고찰)

  • Park, Bum-Soo;Kim, Yeong-Min;Hur, Moo-Won;Lee, Sang-Hyun
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.36 no.1
    • /
    • pp.137-146
    • /
    • 2020
  • In this study, various application schemes of seismic isolation system which can be applied to Hanok have been studied by analyzing its structural characteristics under seismic load. Structural stability of Hanok is more required against seismic load as Hanok becomes long-spanned and multi-storied. To meet this goal, it becomes necessary to study more advanced technology such as seismic isolation design as well as seismic control design and seismic resistant design suitable to Hanok. Seismic isolation systems have been successfully applied to RC and steel structures to improve structural performance during earthquakes. Based on these previous study, we proposed four application schemes of seismic isolation design suitable for Hanok and analyzed their structural characteristics and applicability to Hanok in conceptual level based on its structural characteristics. The proposed four schemes are base isolation method, ground isolation method, roof isolation method and intermediate-story isolation method. The applicability of the proposed method was evaluated by performing boundary nonlinear dynamic analysis to the typical Hanok for the two types of isolation method, that is, ground isolation method and roof isolation method, and the results showed that the proposed methods produced good performance enough to be applied to Hanok.

A study on the structure of the Three storied Stone pagoda in Gameunsa Temple site. (감은사지 삼층석탑 구조에 관한 연구)

  • Nam, Si-Jin
    • Journal of architectural history
    • /
    • v.17 no.3
    • /
    • pp.7-21
    • /
    • 2008
  • Three-story Stone pagodas in Gameunsa Temple site, one of the early staged stone pagodas, has been known as a standard of Silla stone pagodas. A stone pagoda is not only a stone art work and but also a stone architecture. In understanding the stone pagoda it is very important to be approached with technological side in which we can investigate the stone pagoda deeply and as well as to have been approached with art historical view. Also it needs that we should see the stone pagoda in view of structural safety. We can get many high technique from our ancestors who made Gameunsajiseoktap. 1. To reduce any deformation such as relaxation and sinking of members which is caused by a heavy load the members such as the lower tier of the base is made up of the foundation stone and side stone in each, comprising one stone. 2. A special construction method for connection between wall stone and column stone in stereobates was invented. It is to make column stone projected partially and wall stone be caved in that two members should be jointed well. This unique method is not used any longer after the three-story Stone pagodas in Gameunsa Temple Site. 3. In each side upper and lower member are not engaged as the size of roof stones and support stones of roof stones are different. It can be done for a distribution of perpendicular load and a prevention for relaxation of members. 4. It makes sure that to make upper ends of support stones 10mm lower was to be avoid upper loads to it judging from survey in disassemblying east pagoda. It proves that ancestors who made this stone pagoda had a technique to understand the structural matters to make small members as big as possible, not to engage in joint, to avoid in ends of members from upper load.

  • PDF

A Study on the Framework and Arrangement of Interior Column in Single-Story Buddhist Halls (단층 불전 내주의 결구 및 배열 방식에 관한 연구)

  • Lee, U-Jong;Jeon, Bong-Hui
    • Korean Journal of Heritage: History & Science
    • /
    • v.33
    • /
    • pp.210-255
    • /
    • 2000
  • This study aims to classify the framework and arrangement of interior columns (Naeju) which are used in single-story Buddhist halls into several types, and to develop a theory on the process of changes among those types. Since interior columns are building materials which hold up the roof structure and make partitions in the interior space of halls, their framework and arrangement is closely linked to the development of building technology and is expected to reflect new architectural needs. The kinds of interior columns classified by the shape of framework are goju, chaduju, oepyonju, naepyonju. The arrangement of interior columns can he classified by two methods: One which counts the number of the interior column arrangements in a hall, and the other whose classification relates with the side wall columns - Jeongchibup and yijubup. With the combination of these classifications, we can divide the framework and arrangement of interior columns into 8 types From the remains of Korean and Chinese Architecture, we can presume that before the late-Goryo period, jeongchibup had always been applied in the construction of Buddhist halls, and gamju(column reducing) had only been used in examples of small scale. After the founding of Choseon Kingdom, however, national policy had weakened the economic power of Buddhist temples. Because of that, large-scale outdoor Buddhist mass was replaced by small-scale indoor mass, and for this reason, though the scale of Buddhist halls became smaller, the need for a broad interior space became stronger. Thus in early-Choseon period, reduction of interior columns became widely spread. Those types of framework and arrangement of interior columns where yijubup was applied were developed because the rear interior columns arrangements, in order to expand the interior space, have moved backward. Among these types, yiju-goju and yiju-chaduju were developed for the Buddhist halls with paljak roof(hipped-gabled roof), where the load of their side eaves caused structural problems at the side walls. And oepyonju type was for the small-scale and middle-scale Buddhist halls which needed more interior space but didn't want the extension of roof structure. From the local and periodic distribution of each types, we can conclude that the types jeongchi-goju, jeongchi-chaduju and yiju-chaduju have been settled as typical technique of local carpenters. Oepyonju was developed later than the other types, but for its merit of low cost, it became a popular type across the nation.

Analysis of light-frame, low-rise buildings under simulated lateral wind loads

  • Fischer, C.;Kasal, B.
    • Wind and Structures
    • /
    • v.12 no.2
    • /
    • pp.89-101
    • /
    • 2009
  • The Monte Carlo procedure was used to simulate wind load effects on a light-frame low-rise structure of irregular shape and a main wind force resisting system. Two analytical models were studied: rigid-beam and rigid-plate models. The models assumed that roof diaphragms were rigid beam or rigid plate and shear walls controlled system behavior and failure. The parameters defining wall stiffness, including imperfections, were random and included wall stiffness, wall capacity and yield displacements. The effect of openings was included in the simulation via a set of discrete multipliers with uniform distribution. One and two-story buildings were analyzed and the models can be expanded into multiple-floor structures provided that the assumptions made in this paper are not violated.

Seismic performance of RC frames retrofitted with haunch technique

  • Akbar, Junaid;Ahmad, Naveed;Alam, Bashir;Ashraf, Muhammad
    • Structural Engineering and Mechanics
    • /
    • v.67 no.1
    • /
    • pp.1-8
    • /
    • 2018
  • Shake table tests performed on five 1:3 reduced scale two story RC moment resisting frames having construction defects, have shown severe joint damageability in deficient RC frames, resulting in joint panels' cover spalling and core concrete crushing. Haunch retrofitting technique was adopted herein to upgrade the seismic resistance of the deficient RC frames. Additional four deficient RC frames were built and retrofitted with steel haunch; both axially stiffer and deformable with energy dissipation, fixed to the beam-column connections to reduce shear demand on joint panels. The as-built and retrofitted frames' seismic response parameters are calculated and compared to evaluate the viability of haunch retrofitting technique. The haunch retrofitting technique increased the lateral stiffness and strength of the structure, resulting in the increase of structure's overstrength. The retrofitting increased response modification factor R by 60% to 100%. Further, the input excitation PGA was correlated with the lateral roof displacement to derive structure response curve that have shown significant resistance of retrofitted models against input excitations. The technique can significantly enhance the seismic performance of deficient RC frames, particularly against the frequent and rare earthquake events, hence, promising for seismic risk mitigation.

A Study on the Architectural Form for the Restoration of Boje-roo in Beomeo-sa (범어사 보제루의 복원을 위한 건축형식 연구)

  • Seo, Chi-Sang;Youn, Suk-Hwan
    • Journal of architectural history
    • /
    • v.18 no.6
    • /
    • pp.127-144
    • /
    • 2009
  • This thesis aims to analyze the architectural form for the restoration of noogak(樓閣), Boje-roo(普濟樓) which was constructed at the central court of Beomeo-sa(梵魚寺). The results are as follow; 1. Boje-roo was established in 1700. By the constructional records and poetic essays of the times, the architectural of the establishment building was consisted fo two stories structure. The passage system for the approach to the court was the nuha-jinip(樓下進入), that is to say, one might walk between the columns of lower story of the building. And one could ascent the upper stairs and approach to the upper level, inner court. 2. By the remodelling in 1812, the building was varied to one story structure. Therefore the passage system for the approach to the inner court transformed from the nuha-jinip to the ugak-jinip(隅角進入), that is to say, one might ascent the atairs of the podium and could approach the inner court through the both sides of the building. 3. Under the Japanese imperialistic rule, the structure of it's roof and walls of Boje-roo were altered to the Japanese style. In 1965, the wooden columns were shifted to the concreted column, and the wooden wall-panels were shifted to the brick wall attached stone slates. 4. Conclusively speaking, for the restoration of Boje-roo, the establishment form in 1700 is the more proper than the remodelling form in 1812.

  • PDF