• Title/Summary/Keyword: two-plane measurement

Search Result 263, Processing Time 0.026 seconds

Restrained Effect of End Plate on Plane Strain Test Evaluated by Digital Image Correlation Method (디지털 이미지 코릴레이션 기법으로 평가한 평면변형률 시험의 단부 구속 효과)

  • Jang, Eui-Ryong;Choo, Yoon-Sik;Lee, Won-Taeg;Chung, Choong-Ki
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.03a
    • /
    • pp.22-33
    • /
    • 2008
  • The plane strain test has been used widely in order to examine the stress-strain relation and failure behavior. Its advantages are more realistic simulation of deformation and failure behaviors of soils. Most plane strain tests have been carried out with restrained end plates due to difficulties in manufacturing the equipment with free end condition and also performing it. In this study, plane strain tests with/without bottom plate restraint were performed on Jumunjin-sand. The measurement of overall and local deformation was accomplished by digital image correlation technique as well as external LVDT. By applying digital image correlation method using two consecutive images captured through the transparent wall, local deformation behavior of various parts inside the specimen was estimated. From digital image analysis result, the restrained effect of end plate was examined about formation and development of shear band, and deformation mechanism of sand under plane strain condition.

  • PDF

The effect of mandibular position on measurement in spiral tomography (나선형 단층방사선사진촬영에서 하악골 위치가 측정치에 미치는 영향)

  • Jung Yun-Hoa
    • Imaging Science in Dentistry
    • /
    • v.35 no.2
    • /
    • pp.83-86
    • /
    • 2005
  • Purpose : To evaluate the effect of deviation of mandibular positioning, by changing the mandibular plane inclination, on the measured height and width of mandible in spiral conventional tomography. Materials and Methods : By means of the Scanora multifunctional unit, cross-sectional tomograms were taken from two human dried mandibles at the mandibular angulations: -15 degree, -10 degree, -5 degree, and 0 degree. Twenty-eight sites in two dried mandibles were imaged. One examiner measured the bone heights and widths at selected sites on the images and the actual bone heights were recorded. Results : The bone heights at the four mandibular inclinations overestimated real bone heights and the mean difference between actual heights and image heights on 0 degrees was the smallest (P<0.01). The bone widths on -15 degrees were narrowest and there were significant differences between bone widths measured at the four mandibular inclinations (P<0.001). We found statistically significant differences between both bone heights and widths as measured according to the mandibular plane angle for the posterior region (P<0.01). Conclusion : The use of different mandibular positioning may result in discrepancies in heights and widths when measured from the cross-sectional tomographic images. It is suggested that the mandibular positioning may play a significant role in the measurement of mandibular heights and widths.

  • PDF

Three-Dimensional Analysis of the Shapes of Gathered Skirts (개더스커트 형상프로포션의 3차원적 해석)

  • Lee, Myung-Hee;Jung, Hee-Kyeong
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.30 no.11 s.158
    • /
    • pp.1598-1607
    • /
    • 2006
  • The purpose of this study was to analyze the proportion of gathered skirts using a three-dimensional measurement system. And in this experiment, we have attempted to accumulate three-dimensional data of wearing model and find out adequate methods for analyzing shape of clothes. The experimental design consists of two factorial designs. We established three different kinds of fabrics, ratio of gathers. The measurement tool for three-dimensional model was whole body 3D scanner(Exima-WBS2H). Analysis program used in experiment is RapidForm 2004 PP1 and Pattern Design 2000. Data analysis utilizes SPSS WIN 10.0 Package. As the results show, there were different effect of gather and proportion of shapes among the measurements of width, thickness and areas made by different lines of vision in cross-sectional silhouette. And there were difference shapes of section area at each part of gathered skirts between vertical-outline silhouette and vortical-plane silhouette made by gathering conditions. And also the cross-sectional silhouettes and vertical silhouettes were related to shape of clothes.

Design and Lithographic Fabrication of Elliptical Zone Plate Array with High Fill Factor

  • Anh, Nguyen Nu Hoang;Rhee, Hyug-Gyo;Ghim, Young-Sik
    • Current Optics and Photonics
    • /
    • v.5 no.1
    • /
    • pp.8-15
    • /
    • 2021
  • An elliptical zone plate (EZP) array is important in off-axis optical systems because it provides two advantages. First, the residual beam and the main source are not focused in the same direction and second, the light from the observation plane is not reflected back towards the beam source. However, the fill factor of the previous EZP array was about 76% which was a little low. Hence, this EZP array could not collect the maximum amount of illumination light, which affected the overall optical performance of the lens array. In this study, we propose a new EZP array design with a 97.5% fill factor used in off-axis imaging system for enhancement of brightness and contrast. Then, direct laser lithography was used to fabricate the high fill factor EZP array by moving the XY linear stage of the system in a zigzag motion. The imaging properties of the proposed EZP array were experimentally verified at the focal plane and compared with the previous model.

Design of a Short/Open-Ended Slot Antenna with Capacitive Coupling Feed Strips for Hepta-Band Mobile Application

  • Keum, Kyoseung;Piao, Haiyan;Choi, Jaehoon
    • Journal of electromagnetic engineering and science
    • /
    • v.18 no.1
    • /
    • pp.46-51
    • /
    • 2018
  • In this paper, a planar printed hybrid short/open-ended slot antenna with capacitive coupling feed strips is proposed for hepta-band mobile applications. The proposed antenna is comprised of a slotted ground plane on the top plane and two capacitive coupling feed strips with a chip inductor on the bottom plane. At the low frequency band, the short-ended long slot fed by strip 1 generates its half-wavelength resonance mode, whereas the T-shaped open ended slot fed by strip 2 generates its quarter-wavelength resonance mode for the high frequency band. The antenna provides a wide bandwidth covering GSM850/GSM900/DCS/PCS/UMTS/LTE2300/LTE2500 operation bands. Moreover, the antenna occupies a small volume of $15mm{\times}50mm{\times}1mm$. The operating principle of the proposed antenna and the simulation/measurement results are presented and discussed.

Development of On-machine Measurement System utilizing a Capacitive-type Sensor (정전용량형 센서를 이용한 기상계측시스템의 개발)

  • 김건희;박순섭;박원규;원종호
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.391-395
    • /
    • 2002
  • This paper described about the ultra-precision profile measurement of aspheric surfaces using contact probing technique. A contact probe has been designed as a sensing device to obtain measuring resolutions in nanometer regime utilizing a leaf spring mechanism and a capacitive-type sensor. The contact probe is attached on the z-axis during measurement while aspheric objects are supported on the single point diamond turning machine(SPDTM). The machine xz-axis motions are monitored by a set of two orthogonal plane mirror type laser interferometers. Experimental results show that the contact probing technique developed of On-machine Measurement System in this investigation is capable of providing a repeatability of 20 nanometers with a $\pm$20 uncertainty of 300 nanometers.

  • PDF

Effect of NiO spin switching on the Fe film magnetic anisotropy in epitaxially grown Fe/NiO/Ag(001) and Fe/NiO/MgO(001) systems

  • Kim, Won-Dong;Park, Ju-Sang;Hwang, Chan-Yong;Wu, J.;Qiu, Z.Q.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.366-366
    • /
    • 2010
  • Single crystalline Fe/NiO bilayers were epitaxially grown on Ag(001) and on MgO(001), and investigated by Low Energy Electron Diffraction (LEED), Magneto-Optic Kerr Effect (MOKE), and X-ray Magnetic Linear Dichorism (XMLD). We find that while the Fe film has an in-plane magnetization in both Fe/NiO/Ag(001) and Fe/NiO/MgO(001) systems, the NiO spins switch from out-of-plane direction in Fe/NiO/MgO(001) to in-plane direction in Fe/NiO/Ag(001). These two different NiO spin orientations generate remarkable different effects that the NiO induced magnetic anisotropy in the Fe film is much greater in Fe/NiO/Ag(001) than in Fe/NiO/MgO(001). XMLD measurement shows that the much greater magnetic anisotropy in Fe/NiO/Ag(001) is due to a 90o-coupling between the in-plane NiO spins and the in-plane Fe spins which causes a switching of the NiO spins during the Fe magnetization reversal.

  • PDF

Two-plane Hull Girder Stress Monitoring System for Container Ship

  • Choi Jae-Woong;Kang Yun-Tae
    • Journal of Ship and Ocean Technology
    • /
    • v.8 no.4
    • /
    • pp.17-25
    • /
    • 2004
  • Hull girder stress monitoring system for container ship uses four long-base-strain-gages at mid-ship to monitor the resultant stresses and the applied moment components of horizontal, vertical and torsional moments. The bending moments are estimated by using the conventional strain-moment relations, however, the torsional moment related to the warping strain requires the assumption of the shape of torsional moments over the hull girder. Though this shape could be a sine function with an adequate period, it largely depends upon certain empirical formulas. This paper introduces additional four long-base-strain-gages at mid-ship to derive the longitudinal slope of the warping strain because this slope is directly related to the torsional moment by Bi-moment concept. An open-channel-type cantilever beam has been selected as a simplified model for container ship and the result has proved that the suggested concepts can estimate the torsional component accurately. Finally this method can become reliable technique to derive all external moments in hull girder stress monitoring system for container ships.

A Method for Measurement of Limiting Intrinsic Non-Uniformity Due to Process in CCD-Multiplexers for Focal Plane Arrays

  • Bhan, R.K.;Saxena, R.S.
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.2 no.1
    • /
    • pp.87-92
    • /
    • 2002
  • We present a simple experimental method for determination of limiting intrinsic fixed-pattern non-uniformity (NU) due to fabrication process in two-dimensional CCD multiplexers (MUXs) that are used for hybrid focal plane arrays. Here, this is done by determining separately the two NUs viz. that are $V_T$ dependent and $V_T$ independent. From these measurements, process dependent NU can be extracted. It is argued that $V_T$ dependent NU can be eliminated by designing novel input circuits whereas $V_T$ independent NU, primarily, dependent on process control and material variations may be reduced but cannot be eliminated completely and hence limits the FPA performance eventually.

Development of the Scanning PIV Method with Single Optical Axis (단일 광경로 스캐닝 PIV기법 개발)

  • Kim, Hyoung-Bum
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.2 s.257
    • /
    • pp.181-187
    • /
    • 2007
  • Conventional PIV method uses two optical axis configuration during the image grabbing process. That is, the illumination plane and the recording plane must be parallel. This configuration is very natural to grab the whole field without the image distortion. In the real problem, it is often to meet the situation when this configuration is hard to be fulfilled. In the present study, the new PIV method which uses only single optical axis to grab the particle images is developed. This new PIV method becomes possible by utilizing the scanning method similar to the echo PIV technique. One particle image of the scanning PIV consists of scanned several line images and by repeating this scanning process, two particle images were grabbed and processed to produce the velocity vectors. An optimization study was performed to find parameters which minimize the measurement errors. The effects of particle diameter, beam overlap ratio and particle number density were investigated.