• 제목/요약/키워드: two sample testing

검색결과 251건 처리시간 0.028초

Development and Validation of Primary Method for the Determination of Glucose in Human Serum by Isotope Dilution Liquid Chromatography Tandem Mass Spectrometry and Comparison with Field Methods

  • Lee, Hwa Shim;Lee, Jong Man;Park, Sang Ryoul;Lee, Je Hoon;Kim, Yong Goo
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권6호
    • /
    • pp.1698-1702
    • /
    • 2013
  • Glucose is a common medical analyte measuring in human serum or blood samples. The development of a primary method is necessary for the establishment of traceability in measurements. We have developed an isotope dilution liquid chromatography tandem mass spectrometry as a primary method for the measurement of glucose in human serum. Glucose and glucose-$^{13}C_6$ in sample were ionized in ESI negative mode and monitored at mass transfers of m/z 179/89 and 185/92 in MRM, respectively. Glucose was separated on $NH_2P$-50 2D column, and the mobile phase was 20 mM $NH_4OAc$ in 30% acetonitrile/70% water. Verification of this method was performed by the comparison with NIST SRMs. Our results agreed well with the SRM values. We have developed two levels of glucose serum certified reference material using this method and distributed them to the clinical laboratories in Korea as samples for proficiency testings. The expended uncertainty was about 1.2% on 95% confidence level. In proficiency testings, the results obtained from the clinical laboratories showed about 3.6% and 3.9% RSD to the certified values. Primary method can provide the traceability to the field laboratories through proficiency testings or certified reference materials.

서비스 직원의 감성지능이 서비스지향 조직시민행동에 미치는 영향: 내면연기의 매개효과성 (The Effect of Service Employees'Emotional Intelligence on Service-Oriented OCB through Deep Acting)

  • 양은연;안희규;신호철
    • 품질경영학회지
    • /
    • 제46권3호
    • /
    • pp.659-676
    • /
    • 2018
  • Purpose: Although emotional intelligence(EI) is seemingly related to the service-oriented citizenship behaviors(OCB) of contact employees who are directly interacting with customers, there are only a few studies examining the relationship between the two. This study attempts to provide empirical evidence for a link between EI and service-oriented OCB. In addition, when EI affects service-oriented OCB, this present study identifies which emotional labor strategy between surface acting and deep acting is to be chosen. Methods: The data of EI, service-oriented OCB, surface acting, and deep acting were collected from 142 sales employees who provided services in four large domestic department stores. Hierarchical regression analyses were performed to verify empirically the main effects between EI and service-oriented OCB and mediating effects of emotional labor strategy. Results: The results show that EI is significantly related to service-oriented OCB in the current sample. Results also indicate that the deep acting rather than surface acting reveals a mediating effect in the process of EI affecting service-oriented OCB. Conclusion: The results of this study shows that EI which has a conceptual basis for OCB, can be extended to service-oriented OCB, The results also contribute to expanding the understanding of the relationship between EI and service-oriented OCB by testing the effect of EI on service-oriented OCB through deep acting. Theoretical and practical implications are reviewed, and limitations of the study and suggestions for future research are addressed.

대형 Digital TV용 Display Unit의 강성 측정 (Elastic Modulus Measurement of a Large Size Digital TV Display Unit)

  • 김창희;문성인;최재붕;김영진;이정권;구자춘
    • 한국정밀공학회지
    • /
    • 제22권3호
    • /
    • pp.115-122
    • /
    • 2005
  • As the digital TV markets rapidly growing, many manufacturers introduce large size flat screen TV units. There are two different display types available to large size models which are plasma and TFT-LCD. Since both are constructed with thin large panels that are mostly fragile to even moderate mechanical shock inputs. Some large size panels are severely resonated by the acoustic sound generated TV which deteriorates video quality. Recognizing the potential problems of large displays, accurate measurement of the panels is to be an essential task for the reliable design. Measurement of mechanical properties of a thin large crystallized panel such as TFT-LCD display with traditional material testing equipments is challenging. Since TFT-LCDs are constructed with combination of brittle glass panels, polymer sheets, and liquid crystal, their properties are not only anisotropic but also usually non-linear. Accurate measurement of the properties often requires very expensive facilities. Especially when the size of the test sample is as large as 40-inch or wider, direct measurement cost is prohibitive. Even worse, machining of the large TFT-LCD to make a smaller size specimen that could be fit into a material tester is not possible because of liquid crystal leakage. A new method fer the measurement of elastic modulus of large TFT-LCD panel is presented in this article. The suggested method provides a simple, economic, and user-friendly way fer measuring the elastic modulus of large panels with considerable level of accuracy.

이산코사인변환을 기반으로 한 포트맨토 검정 (A Portmanteau Test Based on the Discrete Cosine Transform)

  • 오승언;조혜민;여인권
    • 응용통계연구
    • /
    • 제20권2호
    • /
    • pp.323-332
    • /
    • 2007
  • 이 논문에서는 이산코사인변환에 의해 유도된 주파수 공간상에서의 포트맨토검정법을 소개한다. 정상시계열의 경우 이산코사인변환 계수는 점근적으로 독립이고 분산은 자기공분산의 선형결합으로 표시된다. 백색잡음에 대한 이산코사인변환 계수의 공분산 행렬은 모든 대각원소가 시계열의 분산인 대각행렬이다. 시계열의 독립성을 검정하기 위해 계수들을 주파수 영역에 따라 2 또는 3개의 그룹으로 분할하고 그룹간의 분산을 비교하여 자료가 백색잡음인지 아닌지를 검정한다. 또한 계수의 제곱값이 반응변수이고 주파수 대역이 설명변수인 회귀모형에서 기울기를 검정하여 백색잡음 여부를 알아본다. 모의실험 결과를 보면 제안한 검정방법이 대부분의 경우 Ljung-Box 검정보다 높은 검정력을 가지는 것으로 나타났다.

Exome sequencing in a breast cancer family without BRCA mutation

  • Noh, Jae Myoung;Kim, Jihun;Cho, Dae Yeon;Choi, Doo Ho;Park, Won;Huh, Seung Jae
    • Radiation Oncology Journal
    • /
    • 제33권2호
    • /
    • pp.149-154
    • /
    • 2015
  • Purpose: We performed exome sequencing in a breast cancer family without BRCA mutations. Materials and Methods: A family that three sisters have a history of breast cancer was selected for analysis. There were no family members with breast cancer in the previous generation. Genetic testing for BRCA mutation was negative, even by the multiplex ligation-dependent probe amplification method. Two sisters with breast cancer were selected as affected members, while the mother of the sisters was a non-affected member. Whole exome sequencing was performed on the HiSeq 2000 platform with paired-end reads of 101 bp in the three members. Results: We identified 19,436, 19,468, and 19,345 single-nucleotide polymorphisms (SNPs) in the coding regions. Among them, 8,759, 8,789, and 8,772 were non-synonymous SNPs, respectively. After filtering out 12,843 synonymous variations and 12,105 known variations with indels found in the dbSNP135 or 1000 Genomes Project database, we selected 73 variations in the samples from the affected sisters that did not occur in the sample from the unaffected mother. Using the Sorting Intolerant From Tolerant (SIFT), PolyPhen-2, and MutationTaster algorithms to predict amino acid substitutions, the XCR1, DLL1, TH, ACCS, SPPL3, CCNF, and SRL genes were risky among all three algorithms, while definite candidate genes could not be conclusively determined. Conclusion: Using exome sequencing, we found 7 variants for a breast cancer family without BRCA mutations. Genetic evidence of disease association should be confirmed by future studies.

NIRS APPLIED TO "PASTA FILATA" CHEESE ANALYSIS

  • Cattaneo, Tiziana M.P.;Maraboli, Adele;Giangiacomo, Roberto
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1519-1519
    • /
    • 2001
  • The aim of this work was to test the feasibility of NIRS in analysing textural characteristics of “Pasta Filata” cheese during the shelf-life. For this purpose, 128 samples of “Pasta Filata” cheese, subdivided into two sets on the basis of the wax used to avoid mechanical damages (paraffin, biodegradable wax), were analysed by using an InfraAlyzer 500 (Bran+Luebbe). Analyses were performed at room temperature. Samples were cut into small cylinders (D=3.2 cm, height = 1 cm), in agreement with literature information. Data were processed by using Sesame Software (Bran+Luebbe). Samples were analysed, during the shelf-life, at 90 and 120 days. In parallel, textural characteristics were detected carrying out a compression method by using an Universal Testing Machine Instron model 4301 (Instron Corporation, Canton, Massachusetts). As compression probe was used a cylinder (D = 5.8 cm, height = 3.7 cm) and a speed rate of 20mm/min was applied. The load at 20 mm of compression was recorded on sample cylinders of 1.7 cm (D) by 2 cm (height). Qualitative analysis of full spectra showed the possibility to gather samples on the basis of the days of shelf-life. The textural characteristics of cheese during the shelf-life was evaluated by comparing NIRS data with rheological results. The best correlation was obtained applying MLR to the first derivative of normalized absorbance values at seven wavelengths. Load values were plotted against the NIR prediction values based on first derivatives. NIRS proved to be an useful tool in classifying samples on the basis of the shelf-life period as well as in predicting their textural characteristics ($R^2$= 0.916, SEC = 0.192, SEP = 0.248, SEV = 0.345).

  • PDF

Bacterial profile of suction drains and the relationship thereof to surgical-site infections in prosthetic breast reconstruction

  • Yoon, Jeongmin;Chung, Jae-Ho;Hwang, Na-Hyun;Lee, Byung-Il;Park, Seung-Ha;Yoon, Eul-Sik
    • Archives of Plastic Surgery
    • /
    • 제45권6호
    • /
    • pp.542-549
    • /
    • 2018
  • Background Despite the increasing popularity of prosthetic breast reconstruction, scant data exist on the microbiological profile of drainage fluid from closed-suction drains and the relationship thereof to surgical-site infections (SSIs) in breast reconstruction surgery. This study aimed to determine whether bacteria isolated from drainage fluid were associated with the development of SSIs, and whether the bacterial profile of drainage fluid could be a clinically useful predictor of SSIs. Methods We performed a retrospective chart review of 61 women who underwent tissue expander/implant or direct-to-implant reconstructions. Patient demographics and culture studies of drainage fluid from suction drains collected on postoperative day 7 were evaluated. Results Sixteen patients (26.23%) were culture-positive, and 45 patients (73.77%) were culture-negative. The most frequently isolated bacteria were coagulase-negative staphylococci, followed by Staphylococcus aureus. SSIs were diagnosed in seven patients and were mostly resolved by systemic antibiotics; however, the tissue expander or implant was explanted in two patients. Positive culture of drainage fluid from closed-suction drains was significantly associated with the development of SSIs (P<0.05). The positive predictive value was 37.50%, and the negative predictive value was 97.78%. Conclusions To our knowledge, this study is the first to demonstrate a significant association between the microbiological profile of drainage fluid from closed-suction drains and the development of SSIs in patients with prosthetic breast reconstructions. The high negative predictive value suggests that microbial testing of drainage fluid from closed-suction drains may have clinical utility. Further prospective studies with larger sample sizes are required to confirm our findings.

Biotemplate Synthesis of Micron Braid Structure CeO2-TiO2 Composite and Analysis of its Catalytic Behavior for CO Oxidation

  • Wang, Chencheng;Jing, Lutian;Chen, Mengpin;Meng, Zeda;Chen, Zhigang;Chen, Feng;Oh, Won-Chun
    • 한국세라믹학회지
    • /
    • 제54권1호
    • /
    • pp.23-27
    • /
    • 2017
  • A series of $CeO_2-TiO_2$ composite samples with different Ce/Ti molar ratios were prepared by the paper template. Powder X-ray diffraction (XRD) and transmission electron microscopy (TEM) were used to confirm a face-centered cubic lattice of $CeO_2$ with Ce/Ti =8:2 or 9:1 and a two phase mixture of anatase titania and face-centered cubic ceria with Ce/Ti = 7 : 3. The field emission scanning electron microscopy (FESEM) results suggest that the products are micron braid structures consisting of fibers with diameters in a range of $1-6{\mu}m$ and lengths of several hundred micrometers. $N_2$ absorption-desorption testing shows that the composite at Ce/Ti molar fraction of 8 : 2 has the largest BET surface area (about $81m^2{\cdot}g^{-1}$). Compared to the pure $CeO_2$ sample, the composites show superior catalytic activity for $H_2$ reduction and CO oxidation. For the micron braid structure $CeO_2-TiO_2$ composite (Ce/Ti = 8 : 2), due to the high surface area and the solid solution with appropriate $Ti^{4+}$ incorporation, the CO conversion at about $280^{\circ}C$ was above 50% and at $400^{\circ}C$ was 100%.

COMPARATIVE STUDY ON THE FRACTURE STRENGTH OF METAL-CERAMIC VERSUS COMPOSITE RESIN-VENEERED METAL CROWNS IN CEMENT-RETAINED IMPLANT-SUPPORTED CROWNS UNDER VERTICAL COMPRESSIVE LOAD

  • Pae, Ahran;Jeon, Kyung-A;Kim, Myung-Rae;Kim, Sung-Hun
    • 대한치과보철학회지
    • /
    • 제45권3호
    • /
    • pp.295-302
    • /
    • 2007
  • Statement of problem. Fracture of the tooth-colored superstructure material is one of the main prosthetic complications in implant-supported prostheses. Purpose. The purpose of this in vitro study was to compare the fracture strength between the cement-retained implant-supported metal-ceramic crowns and the indirect composite resinveneered metal crowns under the vertical compressive load. Material and methods. Standard implants of external type (AVANA IFR 415 Pre-mount; Osstem Co., Busan, Korea) were embedded in stainless steel blocks perpendicular to their long axis. Customized abutments were fabricated using plastic UCLA abutments (Esthetic plastic cylinder; Osstem Co., Busan, Korea). Thirty standardized copings were cast with non-precious metal (Rexillium III, Pentron, Walling ford, Conn., USA). Copings were divided into two groups of 15 specimens each (n = 15). For Group I specimens, metal-ceramic crowns were fabricated. For Group II specimens, composite resin-veneered (Sinfony, 3M-ESPE, St. Paul, MN, USA) metal crowns (Sinfony-veneered crowns) were fabricated according to manufacturer's instructions. All crowns were temporary cemented and vertically loaded with an Instron universal testing machine (Instron 3366, Instron Corp., Norwood, MA, USA). The maximum load value (N) at the moment of complete failure was recorded and all data were statistically analyzed by independent sample t-test at the significance level of 0.05. The modes of failure were also investigated with visual analysis. Results. The fracture strength of Sinfony-veneered crowns ($2292.7{\pm}576.0N$) was significantly greater than that of metal-ceramic crowns ($1150.6{\pm}268.2N$) (P < 0.05). With regard to the failure mode, Sinfony-veneered crowns exhibited adhesive failure, while metal-ceramic crowns tended to fracture in a manner that resulted in combined failure. Conclusion. Sinfony-veneered crowns demonstrated a significantly higher fracture strength than that of metal-ceramic crowns in cement-retained implant-supported prostheses.

Comparison of polymer-based temporary crown and fixed partial denture materials by diametral tensile strength

  • Ha, Seung-Ryong;Yang, Jae-Ho;Lee, Jai-Bong;Han, Jung-Suk;Kim, Sung-Hun
    • The Journal of Advanced Prosthodontics
    • /
    • 제2권1호
    • /
    • pp.14-17
    • /
    • 2010
  • PURPOSE. The purpose of this study was to investigate the diametral tensile strength of polymer-based temporary crown and fixed partial denture (FPD) materials, and the change of the diametral tensile strength with time. MATERIAL AND METHODS. One monomethacrylate-based temporary crown and FPD material (Trim) and three dimethacrylate-based ones (Protemp 3 Garant, Temphase, Luxtemp) were investigated. 20 specimens (${\phi}\;4\;mm\;{\times}\;6\;mm$) were fabricated and randomly divided into two groups (Group I: Immediately, Group II: 1 hour) according to the measurement time after completion of mixing. Universal Testing Machine was used to load the specimens at a cross-head speed of 0.5 mm/min. The data were analyzed using one-way ANOVA, the multiple comparison Scheff$\acute{e}$ test and independent sample t test ($\alpha\;=\;0.05$). RESULTS. Trim showed severe permanent deformation without an obvious fracture during loading at both times. There were statistically significant differences among the dimethacrylate-based materials. The dimethacrylate-based materials presented an increase in strength from 5 minutes to 1 hour and were as follows: Protemp 3 Garant (23.16 - 37.6 MPa), Temphase (22.27 - 28.08 MPa), Luxatemp (14.46 - 20.59 MPa). Protemp 3 Garant showed the highest value. CONCLUSION. The dimethacrylate-based temporary materials tested were stronger in diametral tensile strength than the monomethacrylate-based one. The diametral tensile strength of the materials investigated increased with time.