• Title/Summary/Keyword: two point correction

Search Result 152, Processing Time 0.02 seconds

Quantitative Measurement of Soot concentration by Two-Wavelength Correction of Laser-Induced Incandescence Signals (2파장 보정 Laser-Induced Incandescence 법을 이용한 매연 농도 측정)

  • 정종수
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.5 no.3
    • /
    • pp.54-65
    • /
    • 1997
  • To quantify the LII signals from soot particle of flames in diesel engine cylinder, a new method has been proposed for correcting LII signal attenuated by soot particles between the measuring point and the detector. It has been verified by an experiment on a laminar jet ethylene-air diffusion flame. Being proportional to the attenuation, the ratio of LII signal at two different detection wavelengths can be used to correct the measured LIIsignal and obtain the unattenuated LII signal, from which the soot volume fraction in the flame can be estimated. Both the 1064-nm and frequency-doubled 532-nm beams from the Nd : YAG laser are used. Single-shot, one-dimensional(1-D) line images are recorded on the intensified CCD camera, with the rectangular-profile laser beam using 1-mm-diameter pinhole. Two broadband optical interference filters having the center wavelengths of 647 nm and 400 nm respectively and a bandwidth of 10 nm are used. This two-wavelength correction has been applied to the ethylene-air coannular laminar diffusion flame, previously studied on soot formation by the laser extinction method in this laboratory. The results by the LII measurement technique and the conventional laser extinction method at the height of 40 nm above the jet exit agreed well with each other except around outside of the peaks of soot concentration, where the soot concentration was relatively high and resulting attenuation of the LII signal was large. The radial profile shape of soot concentration was not changed a lot, but the absolute value of the soot volume fraction around outside edge changed from 4ppm to 6.5 ppm at r=2.8mm after correction. This means that the attenuation of LII signal was approximately 40% at this point, which is higher than the average attenuation rate of this flame, 10~15%.

  • PDF

Skew Correction for Document Images Using Block Transformation (블록 변환을 이용한 문서 영상의 기울어짐 교정)

  • Gwak, Hui-Gyu;Kim, Su-Hyeong
    • The Transactions of the Korea Information Processing Society
    • /
    • v.6 no.11
    • /
    • pp.3140-3149
    • /
    • 1999
  • Skew correction for document images can be using a rotational transformation of pixel coordinates. In this paper we propose a method which corrects the document skew, by an amount of $\theta$ degrees, using block information, where the block is defined as a rectangular area containing adjacent black pixels. Processing speed of the proposed method is faster than that of the method using pixel transformation, since the number of floating-point operations can be reduced significantly. In the proposed method, we rotate only the four corner points of each block, and then identify the pixels inside the block. Two methods for inside pixel identification are proposed; the first method finds two points intersecting the boundary of the rotated block in each row, and determines the pixels between the two intersection points as the inside pixel. The second method finds boundary points based on Bresenham's line drawing algorithm, using fixed-point operation, and fills the region surrounded by these boundaries as black pixels. We have measured the performance of the proposed method by experimenting it with 2,016 images of various English and Korean documents. We have also proven the superiority of our algorithm through performance comparison with respect to existing methods based on pixel transformation.

  • PDF

Loop Closure in a Line-based SLAM (직선기반 SLAM에서의 루프결합)

  • Zhang, Guoxuan;Suh, Il-Hong
    • The Journal of Korea Robotics Society
    • /
    • v.7 no.2
    • /
    • pp.120-128
    • /
    • 2012
  • The loop closure problem is one of the most challenging issues in the vision-based simultaneous localization and mapping community. It requires the robot to recognize a previously visited place from current camera measurements. While the loop closure often relies on visual bag-of-words based on point features in the previous works, however, in this paper we propose a line-based method to solve the loop closure in the corridor environments. We used both the floor line and the anchored vanishing point as the loop closing feature, and a two-step loop closure algorithm was devised to detect a known place and perform the global pose correction. We propose an anchored vanishing point as a novel loop closure feature, as it includes position information and represents the vanishing points in bi-direction. In our system, the accumulated heading error is reduced using an observation of a previously registered anchored vanishing points firstly, and the observation of known floor lines allows for further pose correction. Experimental results show that our method is very efficient in a structured indoor environment as a suitable loop closure solution.

Real time Image Processor for Reproduction of Gray Levels in Dark Areas on Plasma Display Panel (PDP) (플라즈마 디스플레이 패널의 어두운 영역에서의 계조 재현을 위한 실시간 영상처리기)

  • Lee, Chang-Hun;Park, Seung-Ho;Gang, Jin-Gu;Kim, Chun-U
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.1
    • /
    • pp.46-54
    • /
    • 2002
  • Plasma Display Panel (PDP) is required to be both the determination of white point of each gray level and the inverse gamma correction since no-balanced RGB cell and linear property of PDP, respectively. However, these two methods cause degradation of grey level representation and undesirable false contour in the dark areas on PDP. In this paper, we implemented real time image processor of the proposed error diffusion algorithm and unsharp masking operation to protect the blurring image caused by the error diffusion. Experimental results showed drastic improvements of gray level representation and reduction of undesirable false contour.

Efficient Mechanical System Optimization Using Two-Point Diagonal Quadratic Approximation in the Nonlinear Intervening Variable Space

  • Park, Dong-Hoon;Kim, Min-Soo;Kim, Jong-Rip;Jeon, Jae-Young
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.9
    • /
    • pp.1257-1267
    • /
    • 2001
  • For efficient mechanical system optimization, a new two-point approximation method is presented. Unlike the conventional two-point approximation methods such as TPEA, TANA, TANA-1, TANA-2 and TANA-3, this introduces the shifting level into each exponential intervening variable to avoid the lack of definition of the conventional exponential intervening variables due to zero-or negative-valued design variables. Then a new quadratic approximation whose Hessian matrix has only diagonal elements of different values is proposed in terms of these shifted exponential intervening variables. These diagonal elements are determined in a closed form that corrects the typical error in the approximate gradient of the TANA series due to the lack of definition of exponential type intervening variables and their incomplete second-order terms. Also, a correction coefficient is multiplied to the pre-determined quadratic term to match the value of approximate function with that of the previous point. Finally, in order to show the numerical performance of the proposed method, a sequential approximate optimizer is developed and applied to solve six typical design problems. These optimization results are compared with those of TANA-3. These comparisons show that the proposed method gives more efficient and reliable results than TANA-3.

  • PDF

Source and LVis based coincidence summing correction in HPGe gamma-ray spectrometry

  • Lee, Jieun;Kim, HyoJin;Kye, Yong Uk;Lee, Dong Yeon;Kim, Jeung Kee;Jo, Wol Soon;Kang, Yeong-Rok
    • Nuclear Engineering and Technology
    • /
    • v.54 no.5
    • /
    • pp.1754-1759
    • /
    • 2022
  • The activity of gamma-ray emitting nuclides is calculated assuming that each gamma-ray is detected individually; thus, the magnitude of the coincidence summing signal must be considered during activity calculations. Here, the correction factor for the coincidence summing effect was calculated, and the detection efficiencies of two HPGe detectors were compared. The CANBERRA Inc. GC4018 high-purity Ge detector provided an estimate for the peak-to-total ratio using a point source to determine the coincidence summing correction factor. The ORTEC Inc. GEM60 high-purity Ge detector uses EFFTRAN in LVis to obtain the parameters of the detector and source model and the gamma-gamma and gamma-X match estimates, in order to determine the coincidence summing correction factor. Nuclide analyses, radioactivity comparisons, and analyses of reference material samples were performed utilizing certified reference materials to accurately determine the detection efficiencies. For both Co-60 and Y-88, the detection efficiency for a point source increased by an average of at least 12-13%, whereas the detection efficiency determined using LVis increased by an average of at least 13-15%. The calculated radioactivity values of the certified reference material and reference material samples were accurate to within 3% and 6% of the measured values, respectively.

A Study on the Improvement of Image Quality for a Thermal Imaging System with focal Plane Array Typed Sensor (초점면 배열 방식 열상 카메라 시스템의 화질 개선 연구)

  • 박세화
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.1 no.2
    • /
    • pp.27-31
    • /
    • 2000
  • Thermal imaging system is implemented for the measurement and the analysis of the thermal distribution of the target objects. The main Part of the system is thermal camera in which a focal plane array typed sensor is introduced The sensor detects mid-range infrared spectrum or target objects and then it output generic video signal which should be processed to form a thermal image frame. A digital signal processor(DSP) in the system inputs analog to digital converted data. performs algorithms to improve the thermal images and then outputs the corrected frame data to frame buffers for NTSC encoding and for digital outputs.. To enhance the quality of the thermal images, two point correction method is applied. Figures indicate that the corrected thermal images are much improved.

  • PDF

Study on Structure and Principle of Linear Block Error Correction Code (선형 블록 오류정정코드의 구조와 원리에 대한 연구)

  • Moon, Hyun-Chan;Kal, Hong-Ju;Lee, Won-Young
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.13 no.4
    • /
    • pp.721-728
    • /
    • 2018
  • This paper introduces various linear block error correction code and compares performances of the correction circuits. As the risk of errors due to power noise has increased, ECC(: Error Correction Code) has been introduced to prevent the bit error. There are two representatives of ECC structures which are SEC-DED(: Single Error Correction Double Error Detection) and SEC-DED-DAEC(: Double Adjacent Error Correction). According to simulation results, the SEC-DED circuit has advantages of small area and short delay time compared to SEC-DED-DAEC circuits. In case of SED-DED-DAEC, there is no big difference between Dutta's and Pedro's from performance point of view. Therefore, Pedro's code is more efficient than Dutta' code since the correction rate of Pedro's code is higher than that of Dutta's code.

Development of position correction system of door mounting robot based on point measure: Part I-Algorithm (특정점 측정에 근거한 도어 장착 로봇의 위치 보정 시스템 개발: Part I-보정 알고리즘)

  • Kim, Mi Kyung;Kang, Hee Jun;Kim, Sang Myung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.13 no.3
    • /
    • pp.34-41
    • /
    • 1996
  • This work deals with finding a suitable position correction algorithm of industrial robot based on measuring particular points, which calculates two dimensional correction quantities and the must allow visually acceptable door-chassis assembly task. Three optimizing algorithms corresponding to three differ- ent error based performance indices are compared and selected to the best one, in terms of the predefined total uniformity, line uniformity and computational time. The selected algorithm(Total Error Minimization) is implemented for a simple door-chassis model to show its effectiveness.

  • PDF

Correcting the Elastic-modulus Error of Quartz Glass Using Digital Speckle-pattern Interferometry

  • Ziyang Song;Weixian Li;Sijin Wu;Lianxiang Yang
    • Current Optics and Photonics
    • /
    • v.7 no.4
    • /
    • pp.337-344
    • /
    • 2023
  • Three-point bending is the main method for measuring the elastic modulus of a thin plate. Although various displacement transducers may be used to measure the bending, these are single-point measurements, and it is difficult to eliminate the error caused by eccentric load and shear force. Error-correction models for the elastic modulus of quartz glass using digital speckle interferometry are proposed for eccentric load and shear force. First, the positional misalignment between maximum deflection and load is analyzed, and the error caused by eccentric load is corrected. Then, the additional displacement caused by shear force at different positions of the quartz glass plate is explored. The effect of shear deformation is also corrected, by measuring two points. Since digital speckle interferometry has the advantage of full-field measurement, it can simultaneously obtain deflection data for multiple points to realize error correction. Experimental results are presented to demonstrate that the proposed model can effectively correct the measurement error of the elastic modulus.