• Title/Summary/Keyword: twice frequency of utility voltage

Search Result 5, Processing Time 0.019 seconds

A Utility Interactive Photovoltaic Generation System using PWM Chopper and Current Source Inverter (PWM 쵸퍼와 전류형 인버터를 이용한 계통연계형 태양광발전시스템)

  • 이승환;성낙규;오봉환;검성남;이훈구;김용주;한경희
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.3 no.4
    • /
    • pp.323-329
    • /
    • 1998
  • In this paper, we compose of the utility interactive photovoltaic(PV) generation system with a PWM stepdown chopper and a current source inverter. The stepdown chopper is controlled by the several gate pulses (twice frequency of utility voltage, square pulse and without the chopper) of chopper part to reduce pulsation of DC current and size of DC reactor. PV current only is measured for maximum power point tracking without any influence on the variation of insolation and temperature. Therefore, we can control modulation factor of the chopper to operate at maximum power point of solar cell. And, the utility interactive photovoltaic generation system supplies an AC power to the load and the utility power system.

  • PDF

Photovoltaic System using the Stepdown Chopper and Current Source Inverter (강압쵸퍼와 전류형 인버터를 이용한 태양광발전 시스템)

  • 성낙규;이승환;김성남;이훈구;김용주;한경희
    • Proceedings of the KIPE Conference
    • /
    • 1997.07a
    • /
    • pp.370-373
    • /
    • 1997
  • In this paper, we compose of the stepdown chopper and the current source inverter. Because dc side current of the current source inverter pulse with twice frequency of utility, we control that modulation factor of chopper is pulsed twice frequency. Therefore if voltage across the dc reactor equal to zero, it tis decreased. And we control modulation factor of the chopper to operate at maximum power point around of solar cell.

  • PDF

Design of Input.Output Filter of Single Multifunctional UPS (단상 다기능 UPS 입.출력 필터 설계)

  • 김제홍
    • Proceedings of the IEEK Conference
    • /
    • 2002.06e
    • /
    • pp.307-310
    • /
    • 2002
  • A design for the input filter and the output filter of a single-phase UPS system is proposed. And also, this paper describes a reduction of the DC voltage ripple of a single-phase UPS. The input power of proposed UPS fluctuates with twice frequency of the utility source, which causes DC voltage fluctuation. The reduction of the DC voltage fluctuation requires a large DC link capacitor. The proposed method uses a LC series resonant filter paralleled with a conventional smoothing capacitor. The effectiveness of the proposed method was confirmed by simulation results.

  • PDF

Photovoltaic System for the DC Reactor Reduction of the Current Source Inverter (전류형 인버터의 리액터 경감을 위한 태양광발전시스템)

  • Park, In-Duck;Sung, Nark-Kuy;Lee, Seung-Hwan;Kang, Seung-Wook;Lee, Hoon-Goo;Han, Kyung-Hee
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.484-486
    • /
    • 1997
  • In this paper, we compose of the utility phovoltaic system with the stepdown chopper and the current source inverter to reduce pulsation of dc current and dc reactor. We study that control several ways(twice frequency of utility voltage square pulse and without the chopper) of chopper part. Therefore if voltage across the dc reactor equal to zero, it is decreased. And we control modulation factor of the chopper to operate at maximum power point around of solar cell.

  • PDF

Design of Input Output Filter of Uninterruptible Power Supply (무정전전원장치(UPS)의 입출력필터설계에 관한 연구)

  • Kim, Je-Hong;Cho, Yang-Heang;Son, Jae-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2005.10a
    • /
    • pp.132-135
    • /
    • 2005
  • A design for the input filter and the output filter of a single-phase uninterruptible power supply (UPS) system is proposed. A filter design example is presented. And also, this dissertation describes a reduction of the DC voltage ripple of a single-phase UPS. The input power of proposed UPS fluctuates with twice frequency of the utility source, which causes DC voltage fluctuation. The reduction of the DC voltage fluctuation requires a large DC link capacitor. The proposed method uses a LC series resonant filter paralleled with a conventional smoothing capacitor. The effectiveness of the proposed method was confirmed by simulation results.