• 제목/요약/키워드: turbo factor

검색결과 43건 처리시간 0.015초

터널 화재시 연기확산 차단을 위한 양방향 토출 에어커튼 시스템에 대한 연구 (The Study on the Bi-directional Ejection Air Curtain System for Blocking Smoke Diffusion in case of Tunnel Fire)

  • 양상호;최영석;김정엽;김남구;김경엽
    • 한국유체기계학회 논문집
    • /
    • 제17권5호
    • /
    • pp.43-53
    • /
    • 2014
  • This paper presents a the study on air curtain system of top and bottom bi-directional jet air discharge for blocking the spread of smoke in case of tunnel fire. The five kinds different air curtains of A, B, C, D, and E of models for various performance tested after manufactured. A results of the various performance test obtained the best efficiency from E model air curtain. And optimize the injection angle of the air curtain nozzle through the three-dimensional computational fluid dynamics (CFD) analysis and analyzed the effects of external pressure of tunnel. and also single factor design have been applied. At present, our attention is focused on the velocity distribution(flow width and flow position) of 1.5m on the ground in tunnel. Also, analyzed the influence of draft in the tunnel. Detailed effects of discharge angle of air curtain and velocity at nozzle exit are discussed.

업무용 건물의 지열 히트펌프 시스템에 대한 성능 예측 (Performance Prediction on the Application of a Ground-Source Heat Pump(GSHP) System in an Office Building)

  • 손병후;권한솔
    • 설비공학논문집
    • /
    • 제26권9호
    • /
    • pp.409-415
    • /
    • 2014
  • Ground-source heat pump (GSHP) systems have become an efficient alternative to conventional cooling and heating methods due to their higher energy efficiency. These systems use the ground as a heat source and the heat sink for cooling mode operation. The purpose of this simulation study is to evaluate the performance of a hypothetical GSHP system in an office building and to assess the energy saving effect against the existing HVAC systems (boiler and turbo chiller). We collected monthly energy consumption data from an actual office building ($32,488m^2$) in Seoul, and created a model to calculate the hourly building loads with EnergyPlus. In addition, we used GLD (Ground Loop Design) V8.0, a GSHP system design and simulation software tool, to evaluate hourly and monthly performance of the GSHP system. The energy consumption for the GSHP system based on the hourly simulation results were estimated to be 582.6 MWh/year for cooling and 593.2 MWh/year for heating, while those for the existing HVAC systems were found to be 674.5 MWh/year and 2,496.4 MWh/year, respectively. The seasonal performance factor (SPF) of the GSHP system was also calculated to be in the range of 3.37~4.28.

High Resolution 3D Magnetic Resonance Fingerprinting with Hybrid Radial-Interleaved EPI Acquisition for Knee Cartilage T1, T2 Mapping

  • Han, Dongyeob;Hong, Taehwa;Lee, Yonghan;Kim, Dong-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • 제25권3호
    • /
    • pp.141-155
    • /
    • 2021
  • Purpose: To develop a 3D magnetic resonance fingerprinting (MRF) method for application in high resolution knee cartilage PD, T1, T2 mapping. Materials and Methods: A novel 3D acquisition trajectory with golden-angle rotating radial in kxy direction and interleaved echo planar imaging (EPI) acquisition in the kz direction was implemented in the MRF framework. A centric order was applied to the interleaved EPI acquisition to reduce Nyquist ghosting artifact due to field inhomogeneity. For the reconstruction, singular value decomposition (SVD) compression method was used to accelerate reconstruction time and conjugate gradient sensitivity-encoding (CG-SENSE) was performed to overcome low SNR of the high resolution data. Phantom experiments were performed to verify the proposed method. In vivo experiments were performed on 6 healthy volunteers and 2 early osteoarthritis (OA) patients. Results: In the phantom experiments, the T1 and T2 values of the proposed method were in good agreement with the spin-echo references. The results from the in vivo scans showed high quality proton density (PD), T1, T2 map with EPI echo train length (NETL = 4), acceleration factor in through plane (Rz = 5), and number of radial spokes (Nspk = 4). In patients, high T2 values (50-60 ms) were seen in all transverse, sagittal, and coronal views and the damaged cartilage regions were in agreement with the hyper-intensity regions shown on conventional turbo spin-echo (TSE) images. Conclusion: The proposed 3D MRF method can acquire high resolution (0.5 mm3) quantitative maps in practical scan time (~ 7 min and 10 sec) with full coverage of the knee (FOV: 160 × 160 × 120 mm3).