Cavitation Characteristics of a Pump-turbine Model by CFD Analysis

  • Singh, Patrick Mark;Chen, Chengcheng;Chen, Zhenmu;Choi, Young-Do
    • 한국유체기계학회 논문집
    • /
    • 제18권4호
    • /
    • pp.49-55
    • /
    • 2015
  • The pumped storage plant operates with quick change of the discharge as well as quick changes between pump mode and turbine mode. This study focuses on the cavitation analysis of a pump-turbine model because in turbo-machinery, cavitation can reduce the performance and shorten service life. The pump-turbine model system consists of 7 blades, 20 stay vanes (including tongue) and 20 guide vanes. This study adopts the Rayleigh-Plesset model as a cavitation model, which illustrates cavitation by using the air volume fraction method. The pump mode and turbine mode at the operating condition of partial loading, normal and excessive loading are analyzed to investigate the cavitation performance of the pump-turbine. It was observed that this pump-turbine design showed very good cavitation characteristics with no cavitation bubbles in all operating conditions. Overall value of air volume fraction of both mode at different operating condition are lower than 1, which confirms low possibility of cavitation occurrence at current situation.

공진에 의한 터빈 Control Valve 이상 진동 (Abnormal Vibration of Turbine Control Valve due to Resonance)

  • 구재량;김성휘;고우식;이우광;김연환;황재현
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.2100-2104
    • /
    • 2004
  • Amount of Electricity which product generator decide control valve at Turbine. Operating method of Control valve have two mode. First operating method is Partial Arc Admission, and second operating method is Full Arc Admission. Failure of Control Valve have on serious damage electricity lineage. In this Paper, We have investigated resonance that Control Valve spring casing.

  • PDF

가변속도-가변피치 풍력터빈의 정상상태 곡선 결정 방법 (A Method to Define Steady-State Curves for Variable-Speed Variable-Pitch Wind Turbine)

  • 임채욱
    • 대한기계학회논문집B
    • /
    • 제33권11호
    • /
    • pp.894-899
    • /
    • 2009
  • Aerodynamic power and torque of wind turbine are highly nonlinear and its operation mode depends on control strategies. Therefore, it is essential to define steady-state curves for the purpose of control and operation of wind turbine system. The steady-state curves of wind turbine can be defined by determining its operating points. In this paper, an algorithm to determine operating points of variable-speed variable-pitch wind turbine is presented on the basis of pitch-to-feather control strategy. And this algorithm is applied to obtain steady-state curves for an 1.5MW wind turbine.

DFIG 풍력발전시스템에 관한 연구 (Study on Doubly Fed Induction Generator in a wind turbine)

  • 한상열;차삼곤;최원호;이승구
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 춘계학술대회
    • /
    • pp.253-256
    • /
    • 2006
  • This paper shows operating characteristics of DFIG(Double Fed Induction Generator) for wind turbine. The back to back PWM voltage-fed inverter connected between the rotor and grid network operated sub and super-synchronous operating mode, and the vector-controlled DFIG enables the decoupling between active and reactive power as well as between torque and power factor. This paper is validated by simulations and experimental results.

  • PDF

Shoaiba 산업용 보일러의 range mode 운전시 turbine trip 모사 (The simulation of turbine trip on range mode of Shoaiba desalination plant)

  • 이치환;김성호;조창호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.885-890
    • /
    • 2001
  • This simulation shows turbine trip on range mode, combined operation of 4 boilers and 5 turbines, for shoaiba desalination plant which is being operated in Saudi Arabia. In this model, unit master controller controls load demand, fuel and air flowrate to be consumed during operating of the plant. Feedwater controller controls drum level to compensate feedwater with superheater steam flow. This analysis was performed by constructing a dynamic model of the plant using ProTRAX and running it through the appropriate.

  • PDF

Performance Optimization of High Specific Speed Pump-Turbines by Means of Numerical Flow Simulation (CFD) and Model Testing

  • Kerschberger, Peter;Gehrer, Arno
    • International Journal of Fluid Machinery and Systems
    • /
    • 제3권4호
    • /
    • pp.352-359
    • /
    • 2010
  • In recent years, the market has shown increasing interest in pump-turbines. The prompt availability of pumped storage plants and the benefits to the power system achieved by peak lopping, providing reserve capacity, and rapid response in frequency control are providing a growing advantage. In this context, there is a need to develop pumpturbines that can reliably withstand dynamic operation modes, fast changes of discharge rate by adjusting the variable diffuser vanes, as well as fast changes from pumping to turbine operation. In the first part of the present study, various flow patterns linked to operation of a pump-turbine system are discussed. In this context, pump and turbine modes are presented separately and different load cases are shown in each operating mode. In order to create modern, competitive pump-turbine designs, this study further explains what design challenges should be considered in defining the geometry of a pump-turbine impeller. The second part of the paper describes an innovative, staggered approach to impeller development, applied to a low head pump-turbine project. The first level of the process consists of optimization strategies based on evolutionary algorithms together with 3D in-viscid flow analysis. In the next stage, the hydraulic behavior of both pump mode and turbine mode is evaluated by solving the full 3D Navier-Stokes equations in combination with a robust turbulence model. Finally, the progress in hydraulic design is demonstrated by model test results that show a significant improvement in hydraulic performance compared to an existing reference design.

GE 7FA+e DLN-2.6 가스터빈 연소기 연구 : Part Ⅰ 운전조건 최적화 (GE 7FA+e DLN-2.6 Gas Turbine Combustor : Part Ⅰ Operating Condition Optimization)

  • 오정석;김민기;허필원;이장수;윤영빈
    • 한국추진공학회지
    • /
    • 제12권5호
    • /
    • pp.43-50
    • /
    • 2008
  • 서인천 복합 화력발전소의 GE 7FA+e DLN-2.6 가스터빈 연소기 튜닝을 실시하였다. DLN-2.6 연소기는 기동초기 저출력 조건에서 yellow plume 현상과 정상상태보다 높은 수준의 연소진동이 발생하는 문제점이 있었다. 본 논문의 목적은 기동초기의 yellow plume과 연소진동의 발생 원인을 규명하여 실 연소기를 안정적으로 운용할 수 있는 최적의 운전 조건을 제시하는 것이다. 실연소기 튜닝과정을 통해 얻은 자료를 분석한 결과 기동초기 모드 3($20{\sim}30MW$)에서 PM 1 노즐에서의 과농한 혼합기(${\phi}{\sim}1$)에 의해 yellow plume이 생성되었다. 모드 6B($40{\sim}45MW$)에서의 연소진동 발생은 $120{\sim}140Hz$ 부근에서 생성되었고 연소기 온도에 영향을 받지 않는 cold flow 특성으로 보이며 PM 3 노즐에서의 유량과 관련이 있었다.

배압터빈을 사용하는 열병합발전소의 열 회수 온도에 따른 성능특성 분석 (Performance Analysis on CHP Plant using Back Pressure Turbine according to Return Temperature Variation)

  • 임신영;이종준;전영신;김형택
    • 한국유체기계학회 논문집
    • /
    • 제19권6호
    • /
    • pp.26-33
    • /
    • 2016
  • Combined heat and power (CHP) system is one of the power generation system which can generate both electricity and heat. Generally, mid-size and big-size CHP plant in Korea generate electricity from gas turbine and steam turbine, then supply heat from exhaust gas. Actually, CHP can supply heat using district heater which is located at low pressure turbine exit or inlet. When the district heater locates after low pressure turbine, which called back pressure type turbine, there need neither condenser nor mode change operating control logic. When the district heater locates in front of low pressure turbine or uses low pressure turbine extraction steam flow, which calls condensing type turbine, which kind of turbine requires condenser. In this case, mode change operation methods are used for generating maximum electricity or maximum heat according to demanding the seasonal electricity and heat.

운전데이터에 의한 증기터빈 발전소의 부하제어에 관한 고찰 (A Study on Load Control in a Steam Turbine Power Plant using Acquired Data)

  • 우주희;최인규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 B
    • /
    • pp.749-751
    • /
    • 1999
  • We acquired operating data in an existing steam turbine power plant using analog control system to investigate operation characteristics. We analyzed a load control logic to develop a digital turbine control system. The load control logic is constituted of load target, load reference, loading rate, load limit and admission mode transfer of valve. The result of this paper is utilized to implement a digital turbine control system.

  • PDF

가변 풍속시 운전모드 절환을 고려한 이중여자 유도형 풍력발전기의 시뮬레이터 (A Wind Turbine Simulator for Doubly-Fed Induction-type Generator with Automatic Operation Mode Change during Wind Speed Variation)

  • 송승호;심동준;정병창
    • 전력전자학회논문지
    • /
    • 제11권4호
    • /
    • pp.349-360
    • /
    • 2006
  • 이중여자 유도형 풍력발전 시스템은 다른 풍력발전 시스템에 비하여 에너지 변환 효율이 우수하고 전력변환 장치의 용량이 작아도 되는 특성이 있다. 이러한 특징을 살리기 위해서는 풍력발전 시스템에 입력되는 에너지의 변화를 고려하여 발전기의 제어기를 설계해야 한다. 본 논문에서는 상위 제어기와 하위 제어기로 구분하여 이중여자 유도 발전기의 제어기를 설계하였다. 상위 제어가는 풍력발전 시스템에 입력되는 에너지가 변화함에 따라서 발전기의 운전모드를 결정하고 제어 기준값을 계산한다. 발전기의 운전모드는 최저 속도 제어와 가변 토크 제어, 그리고 토크 제한 모드로 구성된다. 하위 제어기는 상위 제어기의 지령에 따라서 발전 시스템의 전류를 제어한다. 또한 본 논문에서는 3kW급 권선형 유도기를 사용한 이중여자 유도형 풍력발전기의 시뮬레이터를 제작하였다. 설계한 제어기는 시뮬레이터에 적용하여 실험적으로 검증하였다.