• Title/Summary/Keyword: turbine governor

Search Result 75, Processing Time 0.02 seconds

Dynamic Characteristic Analysis of Water-Turbine Generator Control System of Sihwa Tidal Power Plant (시화조력발전소 수차발전기 제어시스템의 동적 특성 해석)

  • Ahn, Sang-Ji;Ban, Yu-Hyeon;Park, Chul-Won
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.61 no.4
    • /
    • pp.180-185
    • /
    • 2012
  • Tidal power is one of new and renewable energy sources. The seawater is stored inside a tidal embankment built at the mouth of a river or bay, where tides ebb and flow. The water turbine-generators produce power by exploiting the gap in the water level between the water outside and inside the embankment. Tidal power plant is a large plant that is installed on the sea. And then, the facility's operations and a separate control system for monitoring and maintenance is required. However, this plant predictive control of building systems and technologies have been avoided the transfer of technology from advanced global companies. Accordingly, the control system for core technology development and localization is urgently needed. This paper presents modeling and simulation using by PSS/E about generator, governor, exciter, and power system stabilizer for control system in Sihwa tidal power plant to improve the efficiency and develope of core technology. And the dynamic characteristics of governor and exciter were analyzed.

Failure Analysis of an Inlet Pipe of a Governor Valve in a Steam Turbine of a District Heating System (지역난방 증기 터빈 내 조속기 밸브 Inlet pipe 파손 원인 분석)

  • Chae, Hobyung;Kim, Woo Cheol;Kim, Heesan;Kim, Jung-Gu;Lee, Soo Yeol
    • Corrosion Science and Technology
    • /
    • v.21 no.1
    • /
    • pp.62-67
    • /
    • 2022
  • The objective of this study was to perform failure analysis of an inlet pipe located in a governor valve of a steam turbine in a district heating system. During the operation, the temperature of the governor valve was increased to as high as ~500 ℃, which induced thermal expansion of the inlet pipe along both axial and radial directions. While the inlet pipe did not have contact with the valve seat, the side plane of the upside was constrained by the casing part, which led the inlet pipe to experience stress field in the form of fatigue and creep. The primary crack was initiated at about 30 mm below the top where the complex stress field was anticipated. These results suggest that the main failure mechanism is a combination of thermal fatigue and creep during the operation supported by the observation of apparent beach marks on the fracture surface and pores near the cracks, respectively.

Operation of Battery Energy Storage System for Governor Free and its Effect (주파수추종 운전 적용을 위한 BESS의 운용 방법 및 효과)

  • Cho, Sung-Min;Jang, Byung-Hoon;Yoon, Yong-Bum;Jeon, Woong-Jae;Kim, Chulwoo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.1
    • /
    • pp.16-22
    • /
    • 2015
  • As the development of Battery Energy Storage System(BESS) and the increasing of intermittent energy sources like wind power and photovoltaic, the application of BESS in load frequency control is considered as an effective method. To evaluate the effectiveness of BESS application in frequency control, we defined a governor free model of BESS to conduct dynamic simulation. Using the BESS dynamic model, we implemented the power system dynamic model including steam, gas and hydro turbine generators. In this paper we study the control performance of BESS in primary frequency control. The effect of BESS speed regulation rate and response time on governor free operation is investigated. In addition, we compared BESS from steam turbine generator in view point of frequency regulation.

A Study on Dead-Zone Turbine Control System (불감대 특성을 지닌 터빈제어 계통에 관한 연구)

  • Hwang, Jae-Ho;Lee, Sang-Hyug;Seo, Jin-Heon
    • Proceedings of the KIEE Conference
    • /
    • 1989.11a
    • /
    • pp.332-336
    • /
    • 1989
  • This paper describes the nonlinear analysis and effectual operation methods of thermal power plant turbine control system. When the turbine control governor system has dead-zone characteristic, the effectual frequency development control is difficult, because turbine output does not correspond to frequency deviation in dead-zone. Therefore to obtain effectual correspondance, the turbine dead-zone characteristic must be analyzed by proper method. This paper proposes this nonlinear analysis and effectual plant operating load.

  • PDF

A Study on Reliability Improvement of a Fault Tolerant Digital Governor (내고장성 디지털 조속기의 신뢰성 향상에 관한 연구)

  • Sin, Myeong-Cheol;Jeon, Il-Yeong;Jo, Seong-Hun;Lee, Seong-Geun;Kim, Yun-Sik
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.51 no.5
    • /
    • pp.175-181
    • /
    • 2002
  • In this paper, fault tolerant digital governor is designed to realize ceaseless controlling and to improve the reliability of control system. Designed digital governor huts duplex I/O module and triplex CPU module and also 2 out of 3 voting algorithm and self diagnostic ability. The Processor module of the system(SIDG-3000) is developed based on 32 Bit industrial microprocessor, which guaranteed high quality of the module and SRAM for data also SRAM for command are separated. The process module also includes inter process communication function and power back up function (SRAM for back-up). System reliability is estimated by using the model of Markov process. It is shown that the reliability of triplex system in mission time can be dramatically improved compared with a single control system Designed digital governor system is applied after modelling of the steam turbine generator system of Buk-Cheju Thermal Power Plant. Simulation is carried out to prove the effectiveness of the designed digital governor system

The development of TGOV5 model representing a steam turbine and boiler for implementation into EMTDC (EMTDC용 1차 에너지계 모델(TGOV5) 개발)

  • Hur, J.;Kim, D.J.;Yoon, J.Y.;Moon, Y.H.;Lee, J.;Yoon, Y.B.
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.282-285
    • /
    • 2001
  • In general, the PSS/E program based on RMS mathematical models is used for analyzing the steady state and transient stability phenomena of full-scale large power system. Whereas, the EMTDC program unlike PSS/E, studies the specific reduced small-scale power systems as a basis of instantaneous value mathematical models and used to analyze the Electro-Magnetic transient characteristics. The PSS/E provides various control models such as exciter, governor, PSS models and TGOV5 model but there are few control models in EMTDC. In this paper, we developed EMTDC model for TGOV5 of a steam turbine and boiler which represents governor action, main, reheat and low-pressure effects, including boiler effects. The EMTDC model is developed by examining PSS/E control block and using User Define Model(UDM) in addition to default.lib provided by EMTDC. We verify the correctness of developed TGOV5 model with PSS/E and EMTDC simulation results using Governor Step(GSTEP) method.

  • PDF

A Study on Development of Signal Conditioner for Test of Automatic Control Equipments in Hydro Power Plant (수력발전소 자동제어설비 시험용 신호변환장치 개발에 관한 연구)

  • Byun, Doo-Gyoon;Chang, Moon-Soung;Kim, Ju-Hyeon
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.169-171
    • /
    • 1995
  • Automatic control equipment in hydro power plant, such as turbine governor or automatic voltage regulator have to act promptly against for variation of power system, so it is necessary to check and test continuously. During last five years, the performance test of automatic control equipment was performed about 20 units of hydro turbine generator. In this process, because it has complex connection and before calibration, signal conditioner was developed as an auxiliary equipment for performance test. It includes function of signal amplifier, transducer, and meters. As a result of use this equipment for electric governor test at soyang-gang hydro power plant, it was possible to find output data equal to old one.

  • PDF

Modeling and Simulation of Loss of Excitation of Hydro Generator Control System (수력 발전기 제어시스템의 계자상실 모델링과 시뮬레이션)

  • Park, Chul-Won
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.2
    • /
    • pp.74-80
    • /
    • 2014
  • Generator protection device has to detects an internal fault conditions in generator and abnormal operating conditions must be due to the hazards. Loss of excitation may cause generator itself failure as well as serious operating problem in power system, and then requires an appropriate response of generator protection device. Details modeling of generator control system and analysis of transient states in generator are important for optimal operation in power plants. In addition, the fault simulation data are also used for testing the characteristics of IED. In this paper, the hydro generator control system using PSCAD/EMTDC, visual simulation for power systems, was modeled. The generator control system which is composed of generator, turbine, exciter, governor was implemented. The parameters of generator control system model were obtained from field power plant. Loss of excitation simulations were performed while varying the fixed load. Several signals analysis were also performed so as to analyze transients phenomena.

Passivity-based Control Approach of Exciter and Governor Systems for Synchronous Electric Generators (Passivity 기반 동기 발전기의 여자기 및 조속기 시스템의 제어 기법)

  • Cho, Hyun Cheol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.4
    • /
    • pp.561-568
    • /
    • 2018
  • Passivity theory is significantly applied to analyze stability of nonlinear dynamic systems and construct its stable control systems. This paper presents a passivity based control design approach for exciters and governors which are employed to regulate the terminal voltage and the rotor velocity of synchronous generator systems in industry fields. We consider the IEEE type 1 exciter and the gas turbine (GT) governor models respectively in this paper. We first carry out a passivity analysis for exciter and governor control systems, which are numerically obtained from its mathematical models. And then its control parameters are selected to assure passivity conditions in a design procedure. Lastly, we investigate numerical simulations to demonstrate reliability of the proposed control approach against large-scale generators with parameter changes.

Improvement in Power System Frequency Control by Automatic Follow-up Regulator of Thermal Power Plant (화력발전소 부하조절기 자동추동장치에 의한 계통주파수 개선에 관한 연구)

  • 권욱현;황재호
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.40 no.1
    • /
    • pp.10-17
    • /
    • 1991
  • An improved control method in turbine control system is proposed. By automatic follow-up design, power system frequency may be maintained within prespecified range. Base or half load control is possible by distributing power plant load allotment. Otherwise, diminutive frequency-load control is dine by governor-free operation in power plant. This paper proposes governor-free operation which is automatically followed by load-limitter setter. The condition which limits governor action may be somewhat improved within boiler condition by this idea. This design has been implemented at Samchunpo thermal power plant. The improved practical results are shown.

  • PDF