• 제목/요약/키워드: tuned-mass damper

검색결과 332건 처리시간 0.028초

Semi-active control of seismic response of a building using MR fluid-based tuned mass damper

  • Esteki, Kambiz;Bagchi, Ashutosh;Sedaghati, Ramin
    • Smart Structures and Systems
    • /
    • 제16권5호
    • /
    • pp.807-833
    • /
    • 2015
  • While tuned mass dampers are found to be effective in suppressing vibration in a tall building, integrating it with a semi-active control system enables it to perform more efficiently. In this paper a forty-story tall steel-frame building designed according to the Canadian standard, has been studied with and without semi-active and passive tuned mass dampers. The building is assumed to be located in the Vancouver, Canada. A magneto-rheological fluid based semi-active tuned mass damper has been optimally designed to suppress the vibration of the structure against seismic excitation, and an appropriate control procedure has been implemented to optimize the building's semi-active tuned mass system to reduce the seismic response. Furthermore, the control system parameters have been adjusted to yield the maximum reduction in the structural displacements at different floor levels. The response of the structure has been studied with a variety of ground motions with low, medium and high frequency contents to investigate the performance of the semi-active tuned mass damper in comparison to that of a passive tuned mass damper. It has been shown that the semi-active control system modifies structural response more effectively than the classic passive tuned mass damper in both mitigation of maximum displacement and reduction of the settling time of the building.

건물의 내진성능을 향상시키기 위한 반능동 동조질량감쇠 시스템 (Structural Vibration Control Using Semiactive Tuned Mass Damper)

  • 문영종;지한록;정형조;이인원
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2006년도 학술발표회 논문집
    • /
    • pp.645-650
    • /
    • 2006
  • This paper presents the results of a study to verify the sufficient control performance of semiactive tuned mass damper and to identify suitable control methods for semiactive tuned mass damper in structural vibration control. In this study, four control algorithms are considered: on-off displacement based groundhook, on-off velocity based groundhook, clipped optimal and maximum energy dissipation algorithm. For semiactive tuned mass damper, MR damper is considered as a controllable damping device and the command voltage is calculated by the control algorithms. Each of the control theory is applied to the three story shear building excited by three earthquakes. The performance of each algorithm is compared with that of conventional tuned mass damper system using evaluation criteria. The simulation results indicate that semiactive tuned mass damper has control efficiency. Among the control algorithms, on-off displacement based control theory shows the best efficacy and robustness.

  • PDF

반능동 진동 흡수 장치의 설계 및 제어 (Design and Control of Semi-Active Tuned Mass Damper)

  • 곽문규;신지환;양동호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.23-25
    • /
    • 2014
  • This paper is concerned with design and control of semi-active tuned mass damper. The equipment consists of permanent magnet and coil. If current flowing in coil is changed, the natural frequency of the semi-active tuned mass damper is changed. In previous research, a current flowing in coil was changed manually. In this time, we design the feedback control system. The experiment proceed that the excitation frequency is shifted from 4Hz to 9Hz. The result of experiment proves that semi-active tuned mass damper is better than passive tuned mass damper in performance of absorbing vibration.

  • PDF

TLCD와 고무패드형 TMD를 이용한 2방향 TLMD의 성능평가실험 (Experimental Performance Evaluation of a 2-way TLMD using a TLCD and a Rubber Bearing-type TMD)

  • 허재성;김홍진;조봉호;조지성;박은천;이상현;이성경;김동영;민경원
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.465-470
    • /
    • 2007
  • In this paper, a two-way tuned liquid mass damper(TLMD) using a tuned liquid column damper(TLCD) and a rubber-bearing-type tuned mass damper(TMD) was manufactured for controlling two-way direction acceleration responses of a high-rise building structure. The proposed controlling device behaves as a tuned liquid column damper in one direction and as a tuned mass damper in the other direction. In this study, Performance evaluation of the downscaled model is conducted. The results show that the two-way controllability is behaved independently each other and realscale TLMD applicable to the high-rise building can be designed.

  • PDF

A semi-active smart tuned mass damper for drive shaft

  • 채교초;박정헌;이철희;박정률;윤동영
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2011년도 추계학술대회 논문집
    • /
    • pp.349-354
    • /
    • 2011
  • Tuned mass damper is widely used in many applications of industry. The main advantage of tuned mass damper is that it can increase the damping ratio of system and reduce the vibration amplitude. Meanwhile, the natural frequency of system will be divided by two peaks, and the peak speeds are closely related to the mass and the stiffness of auxiliary mass system added. In addition, the damping ratio will also affect the peak frequency of the dynamic response. In the present research, the nonlinear mechanical characteristics of rubber is investigated and put into use, since it is usually manufactured as the spring element of tuned mass damper. By the sense of the nonlinear stiffness as well as the damping ratio which can be changed by preload applied on, the shape memory alloy is proposed to control the auxiliary mass system by self-optimizing. Supported by the experiment data of rubber, the 1 DOF theoretical model and finite element model based on computer simulation are implemented to perform the feasibility of the proposed semi-active tuned mass damper working on the drive shaft.

  • PDF

Control of a building complex with Magneto-Rheological Dampers and Tuned Mass Damper

  • Amini, F.;Doroudi, R.
    • Structural Engineering and Mechanics
    • /
    • 제36권2호
    • /
    • pp.181-195
    • /
    • 2010
  • Coupled building control is a viable method to protect tall buildings from seismic excitation. In this study, the semi-active control of a building complex is investigated for mitigating seismic responses. The building complex is formed of one main building and one podium structure connected through Magneto-Rheological (MR) Dampers and Tuned Mass Damper. The conventional semi-active control techniques require a primary controller as a reference to determine the desired control force, and modulate the input voltage of the MR damper by comparing the desired control force. The fuzzy logic directly determines the input voltage of an MR damper from the response of the MR damper. The control performance of the proposed fuzzy control technique for the MR damper is evaluated for the control problem of a seismically-excited building complex. In this paper, a building complex that include a 14-story main building and an 8-story podium structure is applied as a numerical example to demonstrate the effectiveness of semi-active control with Magneto-Rheological dampers and its comparison with the passive control with the Tuned Mass Damper and two uncoupled buildings and hybrid semi-active control including the Tuned Mass Damper and Magneto-Rheological dampers while they are subject to the earthquake excitation. The numerical results show that semi-active control and hybrid semi-active control can significantly mitigate the seismic responses of both buildings, such as displacement and shear force responses, and fuzzy control technique can effectively mitigate the seismic response of the building complex.

Use of semi-active tuned mass dampers for vibration control of force-excited structures

  • Setareh, Mehdi
    • Structural Engineering and Mechanics
    • /
    • 제11권4호
    • /
    • pp.341-356
    • /
    • 2001
  • A new class of semi-active tuned mass dampers, named as "Ground Hook Tuned Mass Damper" (GHTMD) is introduced. This TMD uses a continuously variable semi-active damper (so called 'Ground-Hook') in order to achieve more reduction in the vibration level. The ground-hook dampers have been used in the auto-industry as a means of reducing the vibration of primary suspension systems in vehicles. This paper investigates the application of this damper as an element of a tuned damper for the vibration reduction of force-excited single degree of freedom (SDOF) models that can be representative of many structural systems. The optimum design parameters of GHTMDs are obtained based on the minimization of the steady-state displacement response of the main mass. The optimum design parameters which are evaluated in terms of non-dimensional values of the GHTMD are obtained for different mass ratios and main mass damping ratios. Using the frequency responses of the resulting systems, performance of the GHTMD is compared to that of equivalent passive TMD, and it is found that GHTMDs are more efficient. A design methodology to obtain the tuning parameters of GHTMD using the relationships developed in this paper is presented.

2축 동조 질량 감쇠기를 이용한 구조물의 진동 제어 연구 (A Study of the Structural Vibration Control Using a Biaxial Tuned Mass Damper)

  • 정태영
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2000년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Fall 2000
    • /
    • pp.473-481
    • /
    • 2000
  • Civil structures are becoming more flexible and lightly damped. When subjected to dynamic loads such as wind, earthquake and wave, vibration may be easily induced and lasted for lond duration. To suppress the wind-induced and earthquake-induced vibration of high-rise buildings, study on the development of a tuned mass damper has been carried out. Based on optimal design on passive tuned mass damper which is considered for a building subject to random excitations, a biaxial tuned mass damper was designed and developed. It is confirmed that the vibration levels of the test structure are reduced using the developed tuned mass damper.

  • PDF

실물크기 구조물에 설치된 동조액체질량감쇠기의 성능실험 (Performance Test of a Tuned Liquid Mass Damper installed in a Real-Scaled Structure)

  • 허재성;박은천;이성경;이상현;김홍진;조지성;조봉호;주석준;민경원
    • 한국전산구조공학회논문집
    • /
    • 제21권2호
    • /
    • pp.161-168
    • /
    • 2008
  • 본 연구에서는 하나의 제어장치로 서로 직교하는 2방향의 건물응답을 동시에 제어할 수 있는 동조액체질량감쇠기(Tuned Liquid Mass Damper; TLMD)를 제안하고 제어성능을 실험적으로 검증하였다. 본 연구에서 제안된 TLMD는 한 방향으로는 동조액체기둥감쇠기(Tuned Liquid Column Damper; TLCD) 내부에 채워진 액체의 운동에너지를 이용하여 구조물의 응답을 제어하게 된다. 그리고, 다른 한 방향 즉 TLCD의 직각 방향으로는 LM guide(linear motion guide) 위에 놓인 TLCD 수조와 내부의 액체의 질량을 이용하여 동조질량감쇠기(Tuned Mass Damper; TMD)로 거동하게 함으로써 구조물의 응답을 감소시킨다. 이와 같은 TLMD의 양방향 독립거동 특성을 증명하기 위해 실물크기의 구조물에 설치하여 강제진동실험을 수행하였다. 실험결과, 양방향 모두 대상 구조물의 응답을 감소시키는 것을 확인하여 제안된 TLMD의 효용성을 검증하였다.

다양한 하중의 진동제어를 위한 준능동 TMD의 이용 (Use of Semi-active Tuned Mass Dampers for Vibration Control under Various Excitations)

  • 김현수;김승준;이동근
    • 한국지진공학회논문집
    • /
    • 제10권1호
    • /
    • pp.51-62
    • /
    • 2006
  • 다양한 원인에 의해서 발생하는 구조물의 동적응답을 감소시키기 위하여 현재까지 여러 가지 형태의 동조질량감쇠기(Tuned Mass Damper; TMD)가 개발되었고 이에 대한 많은 연구가 수행되어 왔다. 본 연구에서는 구조물의 응답에 따라서 실시간으로 TMD의 감쇠를 변화시킬 수 있는 준능동 TMD(Semi-active TMD; STMD)의 제어성능을 다양한 형태의 하중을 적용하여 해석적으로 검토하였다. STMD를 구성하는 준능동 감쇠기의 감쇠력을 조절하기 위하여 skyhook 제어알고리즘을 이용하였다. 조화하중 및 임의의 동적하중을 직접가력하중과 지반진동하중 형태로 단자유도 구조물에 가하여 STMD와 일반적인 TMD의 제어성능을 비교하였다. 또한, 주구조물의 질량의 변화에 따른 TMD 및 STMD의 제어성능의 견실성을 비교하였다. 그리고, 가변감쇠장지 뿐만 아니라 MR 감쇠기를 사용한 STMD의 제어성능도 평가하여 새로운 진동제어장치로서의 활용가능성을 검토하였다. 수치해석을 수행한 결과 STMD는 TMD에 비하여 조화하중 및 임의의 동적하중에 대해서 매우 뛰어난 제어성능을 보이는 것을 확인할 수 있었다.