• Title/Summary/Keyword: tuned mass dampers

Search Result 140, Processing Time 0.022 seconds

Effectiveness of design procedures for linear TMD installed on inelastic structures under pulse-like ground motion

  • Quaranta, Giuseppe;Mollaioli, Fabrizio;Monti, Giorgio
    • Earthquakes and Structures
    • /
    • v.10 no.1
    • /
    • pp.239-260
    • /
    • 2016
  • Tuned mass dampers (TMDs) have been frequently proposed to mitigate the detrimental effects of dynamic loadings in structural systems. The effectiveness of this protection strategy has been demonstrated for wind-induced vibrations and, to some extent, for seismic loadings. Within this framework, recent numerical studies have shown that beneficial effects can be achieved by placing a linear TMD on the roof of linear elastic structural systems subjected to pulse-like ground motions. Motivated by these positive outcomes, closed-form design formulations have been also proposed to optimize the device's parameters. For structural systems that undergo a near-fault pulse-like ground motion, however, it is unlikely that their dynamic response be linear elastic. Hence, it is very important to understand whether such strategy is effective for inelastic structural systems. In order to provide new useful insights about this issue, the paper presents statistical results obtained from a numerical study conducted for three shear-type hysteretic (softening-type) systems having 4, 8 and 16 stories equipped with a linear elastic TMD. The effectiveness of two design procedures is discussed by examining the performances of the protected systems subjected to 124 natural pulse-like earthquakes.

Experimental study on the effect of EC-TMD on the vibration control of plant structure of PSPPs

  • Zhong, Tengfei;Feng, Xin;Zhang, Yu;Zhou, Jing
    • Smart Structures and Systems
    • /
    • v.29 no.3
    • /
    • pp.457-473
    • /
    • 2022
  • A high-frequency vibration control method is proposed in this paper for Pumped Storage Power Plants (PSPPs) using Eddy Current Tuned Mass Damper (EC-TMD), based on which a new type of EC-TMD device is designed. The eddy current damper parameters are optimized by numerical simulation. On this basis, physical simulation model tests are conducted to compare and study the effect of structural performance with and without damping, different control strategies, and different arrangement positions of TMD. The test results show that EC-TMD can effectively reduce the control effect under high-frequency vibration of the plant structure, and after the additional damping device forms EC-TMD, the energy dissipation is further realized due to the intervention of eddy current damping, and the control effect is subsequently improved. The Multi-Tuned Mass Damper (MTMD) control strategy broadens the tuning band to improve the robustness of the system, and the vibration advantage is more obvious. Also, some suggestions are made for the placement of the dampers to promote their application.

Serviceability-oriented analytical design of isolated liquid damper for the wind-induced vibration control of high-rise buildings

  • Zhipeng Zhao;Xiuyan Hu;Cong Liao;Na Hong;Yuanchen Tang
    • Smart Structures and Systems
    • /
    • v.33 no.1
    • /
    • pp.27-39
    • /
    • 2024
  • The effectiveness of conventional tuned liquid dampers (TLDs) in controlling the wind-induced response of tall flexible structures has been indicated. However, the impaired control effect in the detuning condition or a considerably high mass cost of liquid may be incurred in ensuring the high-level serviceability. To provide an efficient TLD-based solution for wind-induced vibration control, this study proposes a serviceability-oriented optimal design method for isolated TLDs (ILDs) and derives analytical design formulae. The ILD is implemented by mounting the TLD on the linear isolators. Stochastic response analysis is performed for the ILD-equipped structure subjected to stochastic wind and white noise, and the results are considered to derive the closed-form responses. Correspondingly, an extensive parametric analysis is conducted to clarify a serviceability-oriented optimal design framework by incorporating the comfort demand. The obtained results show that the high-level serviceability demand can be satisfied by the ILD based on the proposed optimal design framework. Analytical design formulae can be preliminarily adopted to ensure the target serviceability demand while enhancing the structural displacement performance to increase the safety level. Compared with conventional TLD systems, the ILD exhibits higher effectiveness and a larger frequency bandwidth for wind-induced vibration control at a small mass ratio.

Simultaneous out-of-plane and in-plane vibration mitigations of offshore monopile wind turbines by tuned mass dampers

  • Zuo, Haoran;Bi, Kaiming;Hao, Hong
    • Smart Structures and Systems
    • /
    • v.26 no.4
    • /
    • pp.435-449
    • /
    • 2020
  • To effectively extract the vast wind resource, offshore wind turbines are designed with large rotor and slender tower, which makes them vulnerable to external vibration sources such as wind and wave loads. Substantial research efforts have been devoted to mitigate the unwanted vibrations of offshore wind turbines to ensure their serviceability and safety in the normal working condition. However, most previous studies investigated the vibration control of wind turbines in one direction only, i.e., either the out-of-plane or in-plane direction. In reality, wind turbines inevitably vibrate in both directions when they are subjected to the external excitations. The studies on both the in-plane and out-of-plane vibration control of wind turbines are, however, scarce. In the present study, the NREL 5 MW wind turbine is taken as an example, a detailed three-dimensional (3D) Finite Element (FE) model of the wind turbine is developed in ABAQUS. To simultaneously control the in-plane and out-of-plane vibrations induced by the combined wind and wave loads, another carefully designed (i.e., tuned) spring and dashpot are added to the perpendicular direction of each Tuned Mass Damper (TMD) system that is used to control the vibrations of the tower and blades in one particular direction. With this simple modification, a bi-directional TMD system is formed and the vibrations in both the out-of-plane and in-plane directions are simultaneously suppressed. To examine the control effectiveness, the responses of the wind turbine without control, with separate TMD system and the proposed bi-directional TMD system are calculated and compared. Numerical results show that the bi-directional TMD system can simultaneously control the out-of-plane and in-plane vibrations of the wind turbine without changing too much of the conventional design of the control system. The bi-directional control system therefore could be a cost-effective solution to mitigate the bi-directional vibrations of offshore wind turbines.

A new study in designing MTMDs in SDOF and MDOF systems based on the spectral analysis method

  • Baigoly, Morteza;Shargh, Farzan H.;Rofooei, Fayaz R.
    • Earthquakes and Structures
    • /
    • v.19 no.4
    • /
    • pp.243-259
    • /
    • 2020
  • This study aims to optimize, design, and predict the MTMDs performance in SDOF systems using spectral analysis, and then apply their results to MDOF structures. Given the importance of spectral analysis in the design of new engineering structures, achieving a method for designing TMDs based on this theory can be of great importance for structural designers. In this study, several convenient combinations of MTMDs in an SDOF system are first considered to minimize the maximum displacement. For calculating the frequency ratios of dampers, an innovative technique is adopted in which the values of different modal responses obtained from the spectral analysis are approached together. This procedure is done using a harmony search (HS) algorithm. Also, using the random vibration theory, the damping ratio of the dampers is obtained. Then, an equation is presented for predicting the performance of MTMDs. For evaluating this equation, three structures with different stories are designed. Some of the presented combinations of dampers are added to them. The time history analyses are employed to analyze the structures under 30 different accelerograms. The findings indicated that the proposed equation could efficiently predict the performance of the MTMDs. Furthermore, four different patterns of damper distribution along the height of the structures are defined. The effect of them on the maximum deformation of the structures in time history analyses is discussed, and an equation is presented to estimate this effect. The results indicated that the average and maximum error percentages of the proposed equations are about three and seven percent, respectively, compared to the time history analyses results, which are negligible values.

Experimental Verification of a Liquid Damper with Changeable Natural Frequency for Building Response Control (고유진동수 조절이 가능한 액체댐퍼의 건물응답 제어실험)

  • Kim, Dong-Ik;Min, Kyung-Won;Park, Ji-Hun;Kim, Jae-Keon;Hwang, Kyu-Seok;Gil, Yong-Sik
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.25 no.4
    • /
    • pp.323-330
    • /
    • 2012
  • This study deals with the experiments of liquid dampers with multi cells whose vertical tubes are divided into several square columns for easily changing natural frequencies. Shaking table test is performed to verify control effectiveness of the dampers which are installed on a building structure. To design liquid dampers, a 64-story building structure is reduced to a SDOF structure with 1/20 of similitude laws based on acceleration. The structure model is made up to adjust its mass and stiffness easily, with separate mass and drive parts. Mass parts indicate real structure's weights and drive parts indicate real structure's stiffness with springs and LM guides. Manufactured liquid damper has 18 cells and its natural frequency ranges are 0.65Hz to 0.81Hz. Shaking table test is carried out with one way excitation to compare with only accelerations of a large-scale structure and a structure installed with liquid dampers. Control performance of the liquid damper is expressed by the transfer function from shaking table accelerations to the large-scale structure ones. Testing results show that the liquid damper reduced a large-scale structure's response by tuned natural frequencies.

Performance evaluation of inerter-based damping devices for structural vibration control of stay cables

  • Huang, Zhiwen;Hua, Xugang;Chen, Zhengqing;Niu, Huawei
    • Smart Structures and Systems
    • /
    • v.23 no.6
    • /
    • pp.615-626
    • /
    • 2019
  • Inerter-based damping devices (IBBDs), which consist of inerter, spring and viscous damper, have been extensively investigated in vehicle suspension systems and demonstrated to be more effective than the traditional control devices with spring and viscous damper only. In the present study, the control performance on cable vibration reduction was studied for four different inerter-based damping devices, namely the parallel-connected viscous mass damper (PVMD), series-connected viscous mass damper (SVMD), tuned inerter dampers (TID) and tuned viscous mass damper (TVMD). Firstly the mechanism of the ball screw inerter is introduced. Then the state-space formulation of the cable-TID system is derived as an example for the cable-IBBDs system. Based on the complex modal analysis, single-mode cable vibration control analysis is conducted for PVMD, SVMD, TID and TVMD, and their optimal parameters and the maximum attainable damping ratios of the cable/damper system are obtained for several specified damper locations and modes in combination by the Nelder-Mead simplex algorithm. Lastly, optimal design of PVMD is developed for multi-mode vibration control of cable, and the results of damping ratio analysis are validated through the forced vibration analysis in a case study by numerical simulation. The results show that all the four inerter-based damping devices significantly outperform the viscous damper for single-mode vibration control. In the case of multi-mode vibration control, PVMD can provide more damping to the first four modes of cable than the viscous damper does, and their maximum control forces under resonant frequency of harmonic forced vibration are nearly the same. The results of this study clearly demonstrate the effectiveness and advantages of PVMD in cable vibration control.

Study on the Motion Control of Tall Buliding Using Mega-Sub System (주(主)-부(副)구조 시스템을 이용한 초고층 건물의 진동제어에 관한 연구)

  • 김진구;송영훈
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.1 no.3
    • /
    • pp.29-35
    • /
    • 1997
  • The megastructure combined with the modular concept is an effcient structural system adequate for ultra-tail buildings for the future. An ingeneous structural control system can be developed by separating the internal subframe in one or many modules from the external megaframe, thus taking advantage of the effect of tuned mass dampers without adding any aditional mass. This so called mega-subcontrol system is generally modeled by a 20DF system for parametric study and for finding optimal values of the parameters. In this study the equation of motion for the system is obtained frist and the preconditions for the simplified modeling are investigated. Finally the optimal value for the subsreucture strffness is fomputed with given mass and damping ratios and transfer functions for responses are abtained for white noise ground exitation to verify the effectiveness of the mega-subcontrol system.

  • PDF

Design and Implementation of Shaking Table using Stepping Motor (스테핑 모터를 이용한 진동대의 설계 및 구현)

  • Jeong, Hyung-Il;Choi, Jai-Hoon;Hong, Kyu-Jang
    • Proceedings of the KIEE Conference
    • /
    • 1997.07b
    • /
    • pp.488-490
    • /
    • 1997
  • This study is focused on the design and performance test of shaking table using stepping motor. Stepping motor can control the motion accurately with generated pulses and is applied to the shaking table. Earthquakes like El Centro and Taft are used as inputs to the shaking table. First, the number of pulses are calculated and sent to pulse generator. Then, the generator controls the table according to the pulse signs. It is shown that the measured signals from the table are in very good agreement with input signals of scale-downed earthquakes of El Centro and Taft. This table will be used for the experimental study of small-scaled building structures with tuned mass dampers under earthquakes.

  • PDF

Tuning of TMDs for Control of Floor Vibration (건물 바닥판의 진동제어를 위한 동조질량감쇠기의 조율)

  • 이동근
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1998.04a
    • /
    • pp.204-211
    • /
    • 1998
  • Floors in a structure are often subject to periodic forces which induce excessive oscillations. For control of such oscillations, TMDs(Tuned Mass Dampers) have been widely used and prooved effective. But it is very difficult to estimate the natural frequency of a TMD when it is installed to a structure. Therefore to achieve the TMD properties that are required for satisfactory performances of the structure, it is necessary to tune the TMDs to the optimal state. This paper is intended to suggest the efficient tuning method for simple and economically designed TMDs and to investigate the validity of the method by installing TMDs to a real structure.

  • PDF