• Title/Summary/Keyword: tube-support

Search Result 285, Processing Time 0.026 seconds

Applicability of Supporting Standard for a Straight Pipe System to an Elbow (직관 지지대 설치 기준의 L형관 설계 적용 가능성에 관한 연구)

  • Han, Sang-Kyu;Lee, Jae-Heon
    • Plant Journal
    • /
    • v.8 no.2
    • /
    • pp.52-58
    • /
    • 2012
  • Pipe means the connection of the tube in order to transfer fluid from one device to another device. The piping stress analysis is to analyze the structural stability considering the location and the features of piping support after completing the piping design, The allowable stresses comply with the requirements of the relevant standards by examining whether the support of the function and location of pipe or re-operation is confirmed. Allowable stresses are to make sure that the maximum stress should not exceed the allowable stress presented in the ASME B31.1 POWER PIPING code. ASME B31.1 POWER PIPING code ensures a smooth stress analysis can be performed during the initial pipe stress analysis as provided in the case of straight pipe to the horizontal distance between the supports. However, because there is no criteria set in the case of curved pipe, the optimum pipe supporting points were studied in this paper. As mentioned about the curved pipe, loads applied to the support of the position of 17% and 83% of the position relative to the elbow part have results similar to the load acting on the support of straight pipe.

  • PDF

Development of Bubble Detector for Extracorporeal Circulation Support System (체외 순환 보조 장치 위한 공기방울 감지 장치 개발)

  • Lee, Hyuk-Soo
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.11 no.4
    • /
    • pp.298-302
    • /
    • 2010
  • Extracorporeal circulation support system is a device for repiratory and heart failure treatment, and there have been many trials for development and clinical application in the world. These devices need to be careful while using is air embolism. Air embolism can be a lethal complication of surgical procedures during which venous pressure at the site of surgery is sub-atmospheric or air is forced under pressure into a body cavity or using extracorporeal circulation support system. To solve the problem, we developed the air detector using relative dielectric constant change. In experiments with a mock circulation system, the proposed system showed a signal difference depending on the amount of air in the tube.

A Experimental Study on Performance Improvement Factors of Used V4 Steel Pipe Support (재사용 V4 강재 파이프 서포트의 성능향상 요인에 관한 실험적 연구)

  • Choi, Myeongki;Park, Jongkeun
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.3
    • /
    • pp.43-48
    • /
    • 2020
  • It is considered that most of reusable pipe supports, which are used as formwork support posting at construction sites, do not meet the performance standard. Due to the use of reusable pipe supports that do not meet such performance standard the potential risk of collapse accident is increasing. Therefore, this study identifies the status of compliance with performance standard, and presents the requirements for improving quality control to prevent the collapse of pipe supports reused at the construction site. First, if the female thread of the product with no clearance and new support pin with the diameter of 12mm are replaced at the same time for use, it is considered that the performance will be improved. Second, as the quality performance during use can be improved in the case of larger thickness of inner diameter compared to the case of larger thickness of outer diameter, it is necessary to increase the inner pipe thickness greatly than the current thickness. Based on the results of this study, it is expected that the performance the reusable pipe support (V4) can be improved, if the diameter of the support pin is 12mm, the female thread has a small clearance, and the inner tube thickness is 2.3 ~ 2.7mm. In addition, it is considered that other performance improvement factors included in the study results could be used as important data for improving the performance of reusable pipe support.

An Accuracy Improvement Method for the Analysis of Process Variation Effect on CNTFET-based Circuit Performance (CNTFET 기반 회로 성능의 공정 편차 영향 분석을 위한 정확도 향상 방법)

  • Cho, Geunho
    • Journal of IKEEE
    • /
    • v.22 no.2
    • /
    • pp.420-426
    • /
    • 2018
  • In the near future, CNTFET(Carbon NanoTube Field Effect Transistor) is considered as one of the most promising candidate for the replacement of modern silicon-based transistors by utilizing the ballistic or near-ballistic transport capability of CNT(Carbon NanoTube). For the large-scale fabrication of high performance CNTFET, semiconducting CNTs have to be well-aligned with a fixed pitch and high densities in the each CNTFET. However, due to the immaturity of the CNTFET fabrication process, CNTs can be unevenly positioned in a CNTFET and existing HSPICE library file cannot support the circuit level evaluation of performance variation caused by the unevenly positioned CNTs. To evaluate the performance variation, linear programming methodology was suggested previously, but the errors can be made during the calculation of the current and the gate capacitance of a CNTFET. In this paper, the reasons causing errors will be discussed in detail and the new methodology to reduce the errors will be also suggested. Simulation results shows that the errors can be reduced from 7.096% to 3.15%.

Study on Thermal Efficiency according to Configuration Change and Contact Resistance of Solar Collector with Single Evacuated Tube-type (단일진공관 태양열집열기의 형상변화 및 접촉저항에 따른 집열효율 연구)

  • Choi, Bo-Won;Yang, Young-Joon
    • Journal of Energy Engineering
    • /
    • v.23 no.4
    • /
    • pp.189-195
    • /
    • 2014
  • The use of solar energy among renewable energy tends to increase because of its infinity and cleanness of resources. Even though the consumption rate of solar energy in our country is still low, however, in recent years, the research for solar energy have been widely conducted due to policy support of government. This study was performed to investigate the efficiency of heat collection using solar collector with single evacuated tube-type. As the results, the temperature of radiation fin for solar collector with single evacuated tube-type was lower in spite of high temperature of heat pipe compared that of double evacuated tube-type. In order to increase the efficiency of heat collection, it was confirmed that the loss of heat collection due to contact resistance as well as performance improvement for solar collector should be decreased.

Multidisciplinary Research for Types and Storytelling Strategies of Science Technology YouTube Channel : focused on Activity-centered Type Video Channel (과학기술 유튜브 채널의 유형과 스토리텔링 전략에 대한 다학제적 연구 : 활동형 채널을 중심으로)

  • Kim, Hye Yung;Yoo, Dong Hwan
    • Korea Science and Art Forum
    • /
    • v.37 no.3
    • /
    • pp.113-123
    • /
    • 2019
  • In line with policy support and demand, mobile videos about science and technology have growth potential. For activation of domestic mobile video contents about science and technology, this article aims to analysis current global leading contents and draw implications for benchmarking. Therefore, this paper attempted to analyzed types and storytelling strategy of Science and technology channels on YouTube, which has the most influence among the mobile video media. The results are as follows. Fist, the YouTube contents about science technology are categorized into three types, activity-, explain-, review-centered type. Second, activity type channels are classified into 4 sub-types. Third, The core storytelling strategy of activity type channels is a combination of familiarity and unfamiliarity to deal with everyday material through specialized scientific and technological methods. Based on the results of this research, we expect to plan and produce global killer contents.

The Effect of Additives on the Mechanical Properties of Rigid Polyurethane (경질 폴리 우레탄의 기계적물성에 미치는 첨가제의 영향)

  • Na, Seok-En;Choi, Hwan-Oh;Lee, Jeon-Kyu;Kim, Si-Young;Ju, Chang-Sik
    • Korean Chemical Engineering Research
    • /
    • v.50 no.5
    • /
    • pp.783-788
    • /
    • 2012
  • Stern tube bearing is a shaft device playing important roles to reduce the friction of axial rotation and to support the weight of shaft. However, because there is no domestic producer of stern tube bering, imported stern tube bearings have many practical problems including prices, delivery and after services. This is why stern tube bearing should be localization. For the purpose of development of polyurethane resin for stern tube bearings, the effect of additives on the hardness, tensile strength and elongation of the polyurethane resin were systematically investigated. For the preliminary researches, depending on the type of curing agent, MOCA type and non-MOCA type polyurethanes were synthesized. Preliminary researches concluded that MOCA type polyurethane resin has more excellent mechanical properties than non-MPCA type for stern tube bearings that Tensile strength and Hardness of non-MOCA type investigated 23 D, 4.3 Mpa. Therefore, MOCA type polyurethane was adapted as base resin of this research. Silica, calcium carbonate and graphite were selected as additives for the enhancement of mechanical properties of polyurethane resin. Effect of the type and the dosage of these additives on the hardness, tensile strength, elongation of the polyurethane resin were experimentally examined. However, addition of calcium carbonate and graphite showed only minor effect on the hardness of the resin. Polyurethane resin with silica showed relatively excellent hardness, tensile strength and improved elongation.

Strength analysis of a filtering structure for a viscoelastic flowing substance (점탄성 유동물질 여과용 필터 구조물의 강도해석)

  • 박창호;정광섭;손태원;주상우
    • Proceedings of the Korean Fiber Society Conference
    • /
    • 1999.04a
    • /
    • pp.300-304
    • /
    • 1999
  • A study is strength analysis of a filtering structure for a viscoelastic flowing substance. Conventional segment type filter units comprise an assembly of two or more individual disc segments stacked at their respective hubs on a central common filtrate collection tube within a filter housing. The conventional type's leaf disc is problem that it don't support a high pressure flows. Therefore, this study develope new structure filtering model to stand a high pressure flows.

  • PDF

A Study on the Development of Tube-to-Support Nonlinear Impact Analysis Model (튜브와 지지대사이의 비선형 충격해석 모델개발에 관한 연구)

  • 김일곤;박진무
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1995.04a
    • /
    • pp.129-136
    • /
    • 1995
  • 본 연구에서는 핵연료봉의 여러가지 모양형태에 대한 충격실험과 해석을 통해 비선형해석 code의 해석모델에 대한 검증을 수행하였다. 이 두 결과의 비교를 통해 개발된 모델은 다중 span을 갖는 보나 봉의 비선형충격해석에 충분히 사용될 수 있음을 확인하였다. 이러한 모델을 통한 비선형충격해석시 주의해야 할 점은 자유진동해석시의 고유진동수를 찾기 위한 경계조건을 정확히 하는 것이 중요하며, 또한 충격해석시의 정확한 충격등가스프링비를 결정하는 것이 중요하다.

  • PDF

Breakaway Fracture Energy(BFE) of Indented Type Bolt for Breakaway Sign Supports (분리식 지주 단부장치에 이용되는 인덴티드 타입 볼트의 분리파괴에너지)

  • Ko, Man-Gi;Kim, Kee-Dong;Jun, Sung-Min;Sung, Jung-Gon
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.4
    • /
    • pp.39-45
    • /
    • 2008
  • Breakaway support for small signs of size $0.293\;m^2{\sim}0.360\;m^2$ using indented tube type bolt of D12 mm with 6 mm inner diameter has been developed and the structural strength of the support system for the wind load was verified through static shear and tension tests. One important value in understanding the dynamic behavior of sign post and impact vehicle is the fracture energy of the sign support. In this study, fracture energy needed to break the sign support was estimated by pendulum test and computer simulation using LS-DYNA program. Support system composed of 3 indented bolts was found to sustain the 43.1 kg$\sim$51.2 kg wind load safely. Fracture energy for one indented bolt was measured as 163.3J from the pendulum test, and was calculated as 153J from the LS-DYNA simulation. The closeness between these two values verified the validity of the simulation model.