• 제목/요약/키워드: trivalent

검색결과 225건 처리시간 0.023초

3가 크롬 박막 내의 극미세 결함 측정을 위한 중성자 소각 산란법의 적용 (Application of Small Angle Neutron Scattering to Determine Nano-size Cracks in Trivlent Chromium Layers)

  • 최용
    • 한국표면공학회지
    • /
    • 제37권3호
    • /
    • pp.175-178
    • /
    • 2004
  • The size and number of nano-size defects of thin trivalent chrome layers were determined by small angle neutron scattering (SANS) without breaking the thin chrome layers. Most of defect size of the trivalent chromium prepared in this test conditions is in the range of about 40nm. The number of nano-size defects less than about 40nm of the trivalent chromium layer increases with plating voltage at constant current density From this study, SANS is proved as one of useful techniques to evaluate nano-size defects of thin film layer.

3가크롬 이온의 전착 반응에 용액 산도 및 유기물 첨가제가 미치는 영향 연구 (Investigation of the Effect of Solution Acidity and Organic Additives on the Electrodeposition of Trivalent Chromium Ions)

  • 이주열;;강대근;김만;권식철
    • 한국표면공학회지
    • /
    • 제43권6호
    • /
    • pp.297-303
    • /
    • 2010
  • The effect of solution acidity and organic additives, polyethylene glycol (PEG), on the trivalent chromium electroplating was systematically investigated in the view point of electroreduction of trivalent chromium ions and solution stability. It was found that solution acidity controlled at pH 2.5 showed the widest current range for bright electrodeposits in the presence of PEG additives, which reduced the local current intensification at high current densities. Through complex interaction between PEG additives and hydrogen ion, that is, solution acidity, electrode potential was moved in the negative direction in the bulk solution, while it shifted in the positive when electric potential was scanned. In conjunction with electrochemical quartz crystal microbalance (EQCM), it was found that PEG additives had a role in promoting the electron transfer to trivalent chromium ion complexes in bulk solution and their adsorption at the electrode surface as well as interfering with hydrogen ion reduction process below pH 2.5. The PEG additives developed the nodular morphology during electroreduction of trivalent chromium ions with the increase of solution acidity and enhanced its current efficiency by maintaining the consumption of complexant, formic acid, at low speed.

Potassium formate, Glycine, Oxalic acid가 황화물계 3가 크롬도금층의 조성과 전류효율에 미치는 영향 (Effect of Potassium Formate, Glycine and Oxalic Acid in Sulfate Bath on Trivalent Chromium Deposition Composition and Current Efficiency)

  • 김만;김대영;박상언;권식철;최용
    • 한국표면공학회지
    • /
    • 제37권2호
    • /
    • pp.86-91
    • /
    • 2004
  • Effect of potassium formate, glycine and oxalic acid in a sulfate solution on the deposit composition and current efficiency of trivalent chromium plating was studied. The trivalent chromium layers prepared by solutions with potassium formate, glycine and oxalic acid contain a few carbon inside. The solutions containing potassium formate, glycine and oxalic acid are relatively stable with pH change. The solution with the potassium formate shows 6-30% current efficiency with current density, whereas, the solutions with oxalic acid and glycine show about 5% current efficiency, respectively. The improved current efficiency is related to enough supply of chromium ions to the electrode due to the increase of pH at the front of electrode.

Characteristics of Cr(III)-based Conversion Coating Solution to Apply Aluminum Alloys for Improving Anti-corrosion Properties

  • Shim, Byeong Yun;Kim, Hanul;Han, Chang Nam;Jang, Young Bae;Yun, Jeong Woo
    • 마이크로전자및패키징학회지
    • /
    • 제23권4호
    • /
    • pp.79-85
    • /
    • 2016
  • It is imperative to find environment-friendly coatings as an alternative to the currently used hexavalent chromate conversion coatings for the purpose of improving the anti-corrosion properties of aluminum alloys. Hence, in this study, the corrosion properties of a trivalent chromate conversion coating solution are analyzed and measured. Because of the presence of multiple components in trivalent chromate conversion coating solutions, it is difficult to control plating, attributed to their mutual organic relationship. It is of significance to determine the concentrations of the components present in these coatings; hence, qualitative and quantitative analysis is required. The coating solution contained not only an environment-friendly component chromium(III), but also zirconium, fluorine, sulfur, and potassium, in the coating film. These metals are confirmed to produce a film with improved corrosion resistance to form a thin layer. The excellent corrosion resistance for the trivalent chromate solution is attributed to various inorganic and organic additives.

3가 크롬황산염의 크로메이트에 의한 아연도금내식성 증대 (Enlargement of Anti-corrosion of Zinc Plating by the Trivalent Chromium Sulfate Conversion Coating)

  • 이철태
    • 공업화학
    • /
    • 제18권3호
    • /
    • pp.296-302
    • /
    • 2007
  • 6가 크롬의 크로메이트 코팅제의 대체를 위한 3가 크롬의 크로메이트 코팅용액의 제조에 관한 것이다. 본 연구에서 제안된 코팅제는 3가 크롬원으로서 $KCr(SO_4)_2$를 35~45 g/L, 인산계 화합물로서 $NaH_2PO_4$를 20~30 g/L을 주성분으로 하고 여기에 금속계 황산화물로서 $CoSO_4$ 10~20 g/L, $ZnSO_4$ 10~20 g/L의 조성으로 구성된 것이다. 이 제안된 3가 크롬 코팅용액을 사용하여 pH 2.0~2.2, 상온에서 담지시간 20~25 s의 조건하에 시안아연도금체에 코팅된 피막은 염수분무시험결과 5% 백청발생까지 120 h 이상 견디는 우수한 내식성을 발현하였다.

산란계에서 Chlorhexidine-inactivated Salmonella Enteritidis, S. Typhimurium 및 S. Gallinarum 3가 백신의 효능평가 (Evaluation of the protective efficacy of trivalent Salmonella inactivated vaccine including Chlorhexidine-inactivated Salmonella Enteritidis, S. Typhimurium and S. Gallinarum in poultry)

  • 유영주;유정희;허진
    • 한국동물위생학회지
    • /
    • 제46권4호
    • /
    • pp.303-314
    • /
    • 2023
  • Protective efficacy of trivalent Salmonella inactivated vaccine containing Chlorhexidine-inactivated S. Enterltidis (SE), S. Typhimurium (ST), and S. Gallinarum (SG) strains, was evaluated in this study. A total of 70 brown nick layers were divided into 7 groups, A to G, containing 10 hens per group. All hens in groups B to D were intramuscularly immunized with approximately 7×108 cells (3×108 cells of SE+1×108 SE+1×108 cells of ST+3×108 cells of SG) of the trivalent vaccine in 0.5 mL of PBS. All chickens in groups E to G were injected with sterile PBS. All hens of groups B and E, groups C and F, and groups D and G were orally challenged with approximately 2 ×109 CFU of wild-type SE, ST, and SG, respectively. Serum IgG titers and CD3+CD4+ T-cells, and CD3+CD8+ T-cells levels of groups B to D significantly higher than those of group A. In addition, all animals in groups A to C, E and F showed no clinical symptoms and survived after the virulent challenges, whereas one chicken in group D died and all chickens in group G died following the challenge. The protection against wild-type SE and ST in liver, spleen, cecum, and cloaca of groups B and C chickens was significant effective as compared with those in groups E and F. These indicate that the trivalent inactivated vaccine can be an effective tool for prevention of Salmonella infections by inducing robustly protective immune responses and cellular immune response in chickens.

고속도금된 3가 크롬도금의 전류효율 및 조직특성에 미치는 첨가제의 영향 (The Effect of Additives on the Current Efficiency and the Microstructure of Trivalent Cr Electrodeposits Plated in Flow Cell System)

  • 예길촌;서경훈
    • 한국표면공학회지
    • /
    • 제37권2호
    • /
    • pp.92-98
    • /
    • 2004
  • The current efficiency and the microstructure of the trivalent Cr deposits plated in flow cell system were investigated according to additives in sulfate bath and current density. The current efficiency of the deposits plated in the formic acid complexed bath was noticeably higher than that of the deposits from glycine complexed bath. The current efficiency of the deposits from the complexed baths with boric acid buffer increased linearly with current density in the range of 60-100 A/dm$^2$, while that of the deposits from the baths with both Al sulfate and mixed buffers increased parabolically with current density. The nodular crystallite size of the deposits increased with current density, and the deposits plated in low current density region had relatively smooth surface appearance with fine grains. The structure of the deposits from the complexed baths with boric acid buffer changed from amorphous structure to crystalline one with strong (110)peak with increasing current density. The deposits from the baths with both Al sulfate and mixed buffers had generally amorphous structure.

KAUFFMAN POLYNOMIAL OF PERIODIC KNOTTED TRIVALENT GRAPHS

  • Aboufattoum, Ayman;Elsakhawy, Elsyed A.;Istvan, Kyle;Qazaqzeh, Khaled
    • 대한수학회보
    • /
    • 제55권3호
    • /
    • pp.799-808
    • /
    • 2018
  • We generalize some of the congruences in [20] to periodic knotted trivalent graphs. As an application, a criterion derived from one of these congruences is used to obstruct periodicity of links of few crossings for the odd primes p = 3, 5, 7, and 11. Moreover, we derive a new criterion of periodic links. In particular, we give a sufficient condition for the period to divide the crossing number. This gives some progress toward solving the well-known conjecture that the period divides the crossing number in the case of alternating links.

3가 크롬도금의 전착속도 및 표면형상에 미치는 첨가제의 영향 (The Effect of Additives on the Deposition Rate and the Surface Morphology of Trivalent Chromium Electrodeposits)

  • 예길촌;서경훈
    • 한국표면공학회지
    • /
    • 제37권1호
    • /
    • pp.13-21
    • /
    • 2004
  • The deposition rate, the current efficiency and surface morphology of trivalent Cr deposits were investigated according to additives in sulfate bath and current density. The deposition rate of the Cr deposits plated from the formic acid complexed bath was noticeably higher than that of the glycine complexed bath. The current efficiency of the deposition from formic acid bath was higher than that of the glycine bath and increased with current density in the range of 20-50 A/d$\m^2$. The current efficiency of the deposition from the formic acid bath with boric acid buffer was higher than that of the bath with aluminum sulfate or boric acid-aluminum sulfate buffers. The nodular crystallite size of the Cr deposits increased with current density and the uniform and crack-free growth of the deposits for the aluminum sulfate was observed compared to the other buffers.

Study on the Microstructure of Trivalent Chrome Layers b AFM and SANS

  • Choi, Y.;Lee, J.J.;Lee, B.K.;Kim, M.;Kwon, S.C.;Seung, B.S.
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2003년도 춘계학술발표회 초록집
    • /
    • pp.61-61
    • /
    • 2003
  • It is important to know SIze distribution of defects In electroplated trivalent chrome layers because it significantly influences on performance of the layers. Most of the nano-scale defects are able to be introduced by hydrogen evolution during the plating. Little information is available on the nano-size defects. In this study, SANS was applied to determine the size distribution of nano-scale defects in the trivalent chrome layers prepared in a formate bath. The defect size and distribution was dependent upon plating conditions such as current density and applied voltage. SANS is one of useful techniques to determine the nano-scale defect in the electroplated layers.

  • PDF