• Title/Summary/Keyword: trip limit

검색결과 39건 처리시간 0.029초

Decision of Maximum Congestion Window Size for TCP Performance Improvement by Bandwidth and RTT Measurement in Wireless Multi-Hop Networks

  • Huh, In;Lee, Jae-Yong;Kim, Byung-Chul
    • Journal of Information Processing Systems
    • /
    • 제2권1호
    • /
    • pp.34-38
    • /
    • 2006
  • In the wireless network, TCP performs poorly because it was originally designed for wired networks and does not take into consideration wireless characteristics such as mobility, high-loss probability, and hidden-terminal problems. In particular, in the wireless multi-hop networks, a large congestion window increases the probability of contention and packet losses, and TCP performance is degraded severely as a result. So, it is necessary to limit the TCP congestion window size in order keep the probability of contention loss in the system to a minimum. In this paper, we propose a new scheme for determining the maximum congestion window size based on the measured bandwidth and Round-Trip-Time (RTT). Using ns-2 simulation, we show that the proposed scheme reduces the probability of packet contention and improves TCP performance.

서울의 통근통행 : 지리적 특성과 변화 (The Geography of Joruney-to-work in the Seoul Metropolitan Area)

  • 허우긍
    • 대한교통학회지
    • /
    • 제11권1호
    • /
    • pp.5-22
    • /
    • 1993
  • This study examines the 1980 Census and the 1987 Travel Survey data sets, in order to identify commuting trends in the Seoul Metropolitan Area. The commuting field of Seoul includes the cities and counties contiguous to Seoul, as well as Inchon, Suwon and Ansan City and Paju County. The study finds little support for the expansion of the commuting field toward distant counties of Kyonggi Province; instead an intensification of commuting within the field is more salient. The most prominent trend, within the city limit of Seoul, is that journey-to-work toward the city center has decreased whereas peripheral journeys increased considerably. The work trips have increased most in the southwestern sector of the city; a moderate increase in the northeastern and southwestern sectors; and decreases in the center and the northwestern sector of the city. Factorial analyses of the work trip data also reveal the emergence of sub-regions of journey-to-work in the peripheries of the city. Such a spatial pattern of commuting changes resemble that of population changes, and correspond in part to the layout of the subway system.

  • PDF

3상 전류평형 제어기술 알고리즘 개발 (A Development of 3 Phase Current Balance Control Algorithm)

  • 천영식;성형수;원학재;한정훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.1091-1093
    • /
    • 2001
  • The power semiconductor is widely used in the power plant or industrial field because of genealization and enlargement. It has been controlled and operated according to its own control method. Especially in case of Power plant, it plays a major role in AVR(Automatic Voltage Regulator) or electro chlorination control circuits. Generally, they used in Analog control system at above field. But each SCR current value is different because of load unbalance or switching characteristic variations, it may cause power plant unit trip or system disorder according to SCR element burn out or bad operating condition. Therefore, in this paper a development of 3 phase current balance control algorithm is described. it gets over the past analog control system limit, controls SCR gate firing angle for 3 phase current balance.

  • PDF

증기터빈 과속도 보호장치의 비교분석 (An Analysis and Comparison of Steam Turbine Overspeed Protectors)

  • 최인규;정창기;김종안
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 D
    • /
    • pp.2260-2262
    • /
    • 2004
  • After steam turbines in power plant drives generator and maintains it at rated speed using high temperature and high pressure steam energy, they regulate the output of generator when synchronized in parallel with the power system. By the way, as the steam flow into turbine can not be reduced fast even though the electrical load is lost, the turbine gets into dangerous situation due to the increase of its speed. At this time, the duty of the turbine governor is "how to limit the speed within its overspeed trip setpoint and escape from danger." For the purpose of it, there are various ways known. Some overspeed protection methods for steam turbines now being operating in korea are introduced in this paper.

  • PDF

증기터빈 밸브제어방식에 따른 과속도 제어 고찰 (A Study on Overspeed Control and Valve Position Control for Steam Turbine in Power Plants)

  • 최인규;우주희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1661-1662
    • /
    • 2008
  • After steam turbines in power plant drives generator and maintains it at rated speed using high temperature and high pressure steam energy, they regulate the output of generator when synchronized in parallel with the power system. By the way, as the steam flow into turbine can not be reduced fast even though the electrical load is lost, the turbine gets into dangerous situation due to the increase of its speed. At this time, the duty of the turbine governor is "how to limit the speed within its overspeed trip setpoint and escape from danger." In order to implement this purpose, there are various ways different from valve position control. So, in this paper, the various methods for overspeed protection are introduced in comparison with valve position control.

  • PDF

원자력발전소 증기터빈 발전기의 부하차단 모의시험 (A simulation test of lone rejection for steam turbine generator in nuclear power plant)

  • 최인규;정태원;이기성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 D
    • /
    • pp.2301-2303
    • /
    • 2003
  • A steam turnine in thermal/nuclear power plant drives generator and maintains it at rated speed using high temperature and high pressure steam energy. After synchronization in parallel with the power system, generator output increases according as the governor, that is the controller, increases steam flow into turbine. By the way, as the steam flow into turbine can not be reduced fast even though the electrical load is lost, the turbine gets into dangerous situation due to the increase of its speed. At this time, the duty of the turbine governor is to limit the speed to its overspeed trip setpoint by stopping the steam flow as soon as possible, the test of which is called load rejection test. It is introduced in this paper for a simulation test of generator load rejection to be implemented on the turbine governor in a 600MW nuclear power plant before its startup.

  • PDF

680MW 원자력발전소 증기터빈 발전기의 부하차단 모의시험 (A Simulation Test of Load Rejection for Steam Turbine Generator in a 680MW Nuclear Power Plant)

  • 최인규;정창기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1605-1606
    • /
    • 2007
  • An electrical generator in power plant is driven and maintained its speed at rated by steam turbine. By the way, after synchronization in parallel with the power system, as the steam flow into turbine can not be reduced fast even though the electrical load is lost, the turbine gets into dangerous situation due to the increase of its speed. At this time, the duty of the turbine governor is to limit the speed to its overspeed trip set point by stopping the steam flow as soon as possible, the test of which is called load rejection test. It is introduced in this paper for a field simulation test of generator load rejection to be implemented on the turbine governor in a 680MW nuclear power plant before its startup.

  • PDF

의사결정 학습 모델 기반 교통카드 데이터 하차 정류장 추정 모델 연구 (A Study of Estimating the Alighting Stop on the Decision Tree Learning Model Using Smart Card Data)

  • 유봉석;추상호
    • 한국ITS학회 논문지
    • /
    • 제18권6호
    • /
    • pp.11-30
    • /
    • 2019
  • 교통카드 데이터는 다양한 대중교통 통계 지표 산출, 정책 및 평가를 위한 자료로 활용되어 그 활용범위가 상당히 높다. 그러나 교통카드 데이터 내 주요 문제점은 하차 정류장에서 태그를 안 하고 하차하는 경우가 대부분으로 이는 교통카드 이용자의 불완전한 OD 통행 자료로 활용범위에 있어 한계가 있다. 본 연구는 의사결정 모델 기반 교통카드 데이터 하차 정류장 추정 방법을 적용한 결과 오차 범위 2개 정류장 이하에서 하차 정류장 추정 정확도는 89.7%으로 분석되었다. 이를 통하여 교통카드 데이터의 불완전성을 해소함으로써 다양한 대중교통 분석 및 평가 등에 대한 기초 자료로 활용 될 수 있을 것으로 판단된다.

중수로 증기발생기 다중 전열관 파단사고시 파단 전열관 수에 대한 영향 분석 (Influence Analysis on the Number of Ruptured SG u-tubes During mSGTR in CANDU-6 Plants)

  • 유선오;이경원
    • 한국압력기기공학회 논문집
    • /
    • 제18권2호
    • /
    • pp.37-42
    • /
    • 2022
  • An influence analysis on multiple steam generator tube rupture (mSGTR) followed by an unmitigated station blackout is performed to compare the plant responses according to the number of ruptured u-tubes under the assumption of a total of 10 ruptured u-tubes. In all calculation cases, the transient behaviour of major thermal-hydraulic parameters, such as the discharge flow rate through the ruptured u-tubes, reactor header pressure, and void fraction in the fuel channels is found to be overall similar to that of the base case having a single SG with 10 u-tubes ruptured. Additionally, as the conditions of low-flow coolant with high void fraction in the broken loop continued, causing the degradation of decay heat removal, the peak cladding temperature (PCT) would be expected to exceed the limit criteria for ensuring nuclear fuel integrity. However, despite the same total number of ruptured u-tubes, because of the different connection configuration between the SG and pressurizer, a difference is foud in time between the pressurizer low-level signal and reactor header low-pressure signal, affecting the time to trip the reactor and to reach the PCT limit. The present study is expected to provide the technical basis for the accident management strategy for mSGTR transient conditions of CANDU-6 plants.

3상 전류평형 제어기술 적용장치 개발 (A Development of 3 Phase Current Balance Control Unit)

  • 천영식;성형수;원학재;한정훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.1088-1090
    • /
    • 2001
  • In general, Power SCR(Silicon Controlled Rectifier) is most widely used in Power Plant as well as Industrial field. It has been controlled and operated according to its own control method. Especially, in case of Power plant, it plays a major role in AVR(Automatic Voltage Regulator) or electro chlorination control circuits. Generally, they used in Analog control system at above field. But each SCR current value is different because of load unbalance or switching characteristic variations, it may cause power plant unit trip or system disorder according to SCR element burn out or bad operating condition. Therefore, in this paper a development of 3 phase current balance control unit is described, it gets over the past analog control system limit, uses DSP(Digital signal processor) had high speed response, controls SCR gate firing angle for 3 phase current balance.

  • PDF