• Title/Summary/Keyword: tricuspid annuloplasty

Search Result 79, Processing Time 0.025 seconds

Clinical Experience of Mitral Valve Replacement with Xenograft (승모판막증의 외과적 치료생체판을 이용한 판치환 : 생체판을 사용한 변치환술)

  • 유회성
    • Journal of Chest Surgery
    • /
    • v.11 no.4
    • /
    • pp.428-432
    • /
    • 1978
  • Between Jan. and Oct. 1978, mitral valve Replacement had been performed on eight patients using porcine aortic valve mounted on flexible polypropylene or Egyloil wire and Dacron covered stent. Mitral valve replacement was performed on five, mitral valve replacement with tricuspid valve replacement on two, and mitral valve replacement with tricuspid valve annuloplasty on 1 patient using five Carpentier and five Hancock Xenograft. Overall operative deaths were 2 cases. All other 6 cases did well after surgery and improved. No systemic thromboembolism occurred without anticoagulant-No valve failure took place. The results are satisfactory.

  • PDF

Ebstein's Anomaly -A Case Report- (엡스타인 심기형 -1례 보고-)

  • 전찬규
    • Journal of Chest Surgery
    • /
    • v.27 no.1
    • /
    • pp.57-59
    • /
    • 1994
  • Ebstein`s anomaly, a rare congenital cardiac anomaly, is characterized by downward displacement of abnormal tricuspid valve. Indication for surgical repair and the optimal surgical approach are still controversy. Recently, we experience a case of Ebstein anomaly, which was treated by atrilized right ventricular plication and annuloplasty. The patient was discharged with good result on 17th post-operative day.

  • PDF

Intermediate-term Result of Tricuspid Annuloplasty for Tricuspid Regurgitation Associated with Congenital Heart Disease in Adult (성인 선천성 심기형에 동반된 삼첨판막 폐쇄부전의 판막륜 성형술 후 중기성적)

  • Yun, Tae-Jin;Kim, Sang-Hwa;Lee, Jun-Wan;Park, Jeong-Jun;Song, Hyun;Lee, Jae-Won;Seo, Dong-Man;Song, Meong-Gun;Song, Jong-Min;Kang, Duck-Hyun;Song, Jae-Kwan;Jang, Wan-Sook;Kim, Young-Hwue;Ko, Jae-Kon;Park, In-Sook
    • Journal of Chest Surgery
    • /
    • v.36 no.3
    • /
    • pp.136-141
    • /
    • 2003
  • We assessed the intermediate-term result of tricuspid annuloplasty (TAP) for tricuspid valve regurgitation (TR) associated with congenital heart disease in adults. Risk factors for residual TR were also analysed. Material and Method: From August 1989 to June 2001, seventy three adult patients, 51 females and 22 males, underwent TAP for TR associated with various congenital heart disease. Their age ranged from 46 years to 73 years (mean:43). Associated heart anomalies were atrial septal defect (55), ventricular septal defect (6), partial anomalous pulmonary venous return (4) and others (8). Preoperative and post-operative TR velocities were 3.25 m/sec and 2.56 m/sec respectively, and the types of TAP were De Vega in 43, Kay in 18 and Ring annuloplasty in 12. Postoperative follow-up duration was 2,347 patient-month (mean: 32.6 months), and 134 two-dimensional echocardiographic examinations were done during this period. Residual TR greater than III/IV was considered as TAP failure. Result: TAP failure was observed in 7 patients (9.6%), and one patient among them underwent tricuspid valve replacement. Risk factors for TAP failure were diagnosis other than atrial septal defect (p=0.001), preoperative (p=0.038) and postoperative (p=0.028) high TR velocity. There was no statistical significance in terms of TAP methods. Conclusion: Careful evaluation of valve morphology and aggressive surgical intervention are mandatory for the repair of TR with preoperative or residual RV pressure overload.

Clinical study of multiple cardiac valve operation (중복판막수술에 대한 임상적 연구)

  • 김승진
    • Journal of Chest Surgery
    • /
    • v.22 no.6
    • /
    • pp.1036-1043
    • /
    • 1989
  • Seventy eight patients underwent operation for combined multiple valve disease, with an overall early mortality of 14.1 % from January, 1983 to September, 1988 in the department of thoracic and cardiovascular surgery of Pusan National University Hospital. All of the above cases had combined multiple valve procedures. There were 33 mitral valve replacements and tricuspid annuloplasties, 33 aortic and mitral valve replacements, 5 aortic and mitral valve replacements with tricuspid annuloplasties, 3 aortic valve replacements and mitral annuloplasties, 1 open mitral commissurotomy and tricuspid annuloplasty and, 1 mitral valve replacement and primary closure of tricuspid valve cleft, 1 mitral valve replacement and aortic commissurotomy, 1 mitral, aortic and tricuspid valve replacement were done. 44 were male and 34 were female and the age distribution was from 14 to 57 with mean 38 year old. According to NYHA[New York Heart Association] classification, 49 patients were class I, 19 patients were class Il and 10 were class IV. Average perfusion time was 205.3 minutes. The live patients perfusion time was 178.7 minutes while that of dead ones was 272.0 minutes. Early deaths within 30 days from operation were 11 cases, 6 of which were due to low cardiac output, 3 were acute renal failure and 2 were cardiac rupture. The 65 patients were followed up from 2 to 30 months for a total 20.6 patient years. 1 patient committed suicide because of postoperative depression 1 year after operation. All of the survivors were enjoying their daily life and their NYHA class was superior to the preoperative ones.

  • PDF

Chordae Tendineae Approximation Technique for Severe Tricuspid Regurgitation with Severe Leaflet Tethering Using a Totally Endoscopic Beating-Heart Strategy: A Case Report

  • Dong Hee Jang;Jae Suk Yoo
    • Journal of Chest Surgery
    • /
    • v.56 no.1
    • /
    • pp.56-58
    • /
    • 2023
  • Untreated severe tricuspid regurgitation (TR) is associated with poor outcomes. Functional TR occurs secondary to dilatation of the annulus and tethering of the leaflets. Ring annuloplasty alone can correct most cases, but is insufficient in cases of severe annular dilatation due to severe leaflet tethering. In such cases, a tricuspid edge-to-edge technique may be an option. However, stitching of the leaflet tips alone is likely to result in tearing of the leaflets. Approximation of the durable chordae tendineae is considered helpful for this problem. Herein, we present the case of a 39-year-old man who had undergone open-heart surgery for acute type A aortic dissection 13 months earlier. A right mini-thoracotomy approach with a beating-heart strategy was used, which did not require unnecessary pericardial adhesiolysis and dissection. This technique had the advantage of reducing the operation time and the risk of bleeding. To summarize, we present a case of tricuspid valve repair in a high-risk patient with severe leaflet tethering that was successfully managed using these methods.

Clinical Analysis of Cardiac Valve Surgery (심장판막증의 외과적 치료)

  • 김형묵
    • Journal of Chest Surgery
    • /
    • v.18 no.3
    • /
    • pp.446-455
    • /
    • 1985
  • A total and consecutive 156 patients have undergone cardiac valve surgery including 13 closed mitral commissurotomy, 13 open mitral commissurotomy, one mitral annuloplasty, 75 mitral valve replacement, one aortic annuloplasty, 24 aortic valve replacement, 3 tricuspid valve replacement, 25 double valve replacement and one triple valve replacement. 155 prosthetic valves were replaced in a period between September 1976 and August 1985. There were 68 males and 88 females with age range from 8 to 69 yrs [mean 36.5 yr]. Out of replaced valves, 61 was tissue valve including 54 Carpentier-Edwards, and 4 was mechanical valves including 74 St. Jude Medical, and the position replaced was 101 valves for mitral, 46 for aortic and 8 for tricuspid. Single valve replacement in 102 cases, double valve replacement in 25 cases [17 for AVR+MVR, and 8 for MVR+TVR], and only one case was noted in the triple valve replacement. Early mortality within 30 days after operation was noted in 11 cases [7%]; 7 after MVR, 2 after DVR, and each one after open mitral commissurotomy and mitral annuloplasty. Cause of death was valve thrombus, cerebral air embolism, low output syndrome, uncontrollable arrhythmia, parapneumonic sepsis, acute cardiac tamponade and left atrial rupture. 7 late deaths were noted during the follow-up period from 1 to 104 months [average 48 month]; three due to valve and left atrial thrombus formation, two due to CVA from overdose of warfarin, and each one due to congestive heart failure and chronic constrictive pericarditis, Anticoagulants after prosthetic valve replacement were maintained with warfarin, dipyridamole and aspirin to the level of around 50% of normal prothrombin time in 79 cases, and Ticlopidine with aspirin in 47 cases to compare the result of each group. There were 11 major thromboembolic episodes including 3 deaths in the warfarin group. Two cases of CVA due to overdose of warfarin was noted in the warfarin group. In the ticlopidine group, there was only one left atrial thrombus confirmed at the time of autopsy. Among the survived 138 cases, nearly all cases[136 cases] were included in NYHA functional class I and II during the follow-up period. In conclusion, surgical treatment of the cardiac valve disease in 156 clinical cases revealed excellent result with acceptable operative risk and late mortality. Prevention of thrombus formation with anti-platelet aggregator Ticlopidine has better result than warfarin group presently with no specific side effect such as bleeding or gastrointestinal trouble.

  • PDF

Clinical analysis of 60 cases of open heart surgery (개심술 치험 60례 보)

  • Kim, Su-Seong;Kim, Yeong-Ho;Kim, Gong-Su
    • Journal of Chest Surgery
    • /
    • v.17 no.3
    • /
    • pp.389-397
    • /
    • 1984
  • Sixty cases of open heart surgery were performed in the Department of Thoracic and Cardiovascular Surgery of Chonbuk National University Hospital from July, 1983 to June, 1984. The patients were consisted of 40 [66%] congenital anomalies containing 26 [43%] patients of acyanotic group and 4 [23%] of cyanotic group, and 20 [34%] acquired heart diseases which involved one or more cardiac valves. The male patients were 42 and the female 18. In 20 valvular heart diseases, open mitral commissurotomy was done in 5 patients, mitral valvular replacement with tissue valve in 6, mitral valvular replacement with mechanical valve in 5, mitral valvular replacement with tricuspid annuloplasty in 2, mitral annuloplasty in 1, and mitral and aortic valvular replacements with mechanical valves in 1. The most frequency complication was low cardiac output syndrome occurred in 9, and the next was urethral stenosis, ARDS, and postoperative bleeding, etc. The perioperative mortality was 21% in congenital cyanotic heart disease, 12% in congenital acyanotic heart disease, and 5% in acquired heart disease.

  • PDF

Mid-term and Long-term Outcomes of Posterior Plication Annuloplasty(Modified Davila Annuloplasty) for Functional Tricuspid Regurgitation (기능성 삼첨판막부전증에 대한 삼첨판후판륜주름술(Davila Technique)의 중장기결과)

  • Lee, Mi-Kyung;Kim, Jong-Hun;Kim, Min-Ho;Jo, Jung-Ku;Choi, Jong-Bum
    • Journal of Chest Surgery
    • /
    • v.41 no.5
    • /
    • pp.580-585
    • /
    • 2008
  • Background: Many types of tricuspid annuloplasty are used in surgical correction of functional tricuspid regurgitation (FTR). We evaluated the mid-term and long-term outcomes in patients treated with a posterior annular plication technique (a modified Davila technique) for FTR. Material and Method: Between January 1991 and August 2006, 58 adult patients (male, 22; female, 36) with FTR of grade 2/4 or more or with tricuspid annular dilatation of more than 5.0cm in diameter, even with an FTR of less than grade 2, had received a posterior annular placation. Preoperatively, 26 patients (44.8%) had a grade 3 or more FTR. All patients had received a mitral valve replacement, and 20 (34.5%) had concomitant aortic valve replacement. Result: During the mean follow-up period of $101.4{\pm}51.6$ months, FTR disappeared or remained trivial in 28 patients (49.1%), was grade $2{\sim}3$ (${\geq}$grade 2 and $2.66{\pm}0.73\;vs.\;0.82{\pm}0.89$; p<0.0001). Patients did not require a second surgery for FTR and did not show further FTR aggravation. Conclusion: The modified Davila posterior annular plication technique for FTR has reasonable mid-term and long-term results and is a useful surgical procedure.

Cor Triatriatum A Case Report (삼중방심 치험 1례)

  • No, Jung-Gi;Lee, Gil-No
    • Journal of Chest Surgery
    • /
    • v.18 no.1
    • /
    • pp.13-18
    • /
    • 1985
  • Cortriatriatum is rare congenital heart disease characterized by the presence of a fibromuscular diaphragm that subdivides the left atrium into a proximal or "accessory" and a distal or "true" left atrial chamber. A 15 year old girl with cortriatriatum underwent surgical correction at the department of Thoracic and Cardiovascular Surgery, Soonchunhyang College in November, 1984. This case was preoperatively diagnosed as a single atrium with functional tricuspid regurgitation But on operation, we found that there were transverse septum in the left atrium through large ASD, low chamber receives the pulmonary veins, and the upper chamber gives rise to the left atrial appendage and leads to the mitral valve. And the anomalous membrane has no fenestrations. We excised completely the anomalous septum, reconstructed atrial septal defect with dacron patch and performed the tricuspid annuloplasty with DeVega method. Postoperative course was uneventful during follow up, during follow up.

  • PDF

Surgical treatment of Ebstein`s Anomaly-Report of 6 cases- (Ebstein 기형의 외과적 치료-6례 보고-)

  • 왕영필
    • Journal of Chest Surgery
    • /
    • v.20 no.3
    • /
    • pp.506-511
    • /
    • 1987
  • Increased clinical interest, stimulated by newer diagnostic techniques, has made it apparent that Ebstein`s anomaly represents a spectrum of right heart abnormalities. In the usual case, the septal and posterior leaflets of the tricuspid valve are not attached to the true annulus, but are displaced distally into the ventricle. Also the degree of malattachment and the structural deformities of the cusps may vary greatly. Recently we experienced 6 cases of Ebstein`s anomaly who underwent corrective operation in our hospital. Five patients were operated by plication and annuloplasty techniques based on the construction of a monocusp valve by the use of the anterior leaflet. Remained one was operated on by tricuspid valve replacement using No 31 mm C-E tissue valve. There was no operative mortality and the postoperative courses were relatively good with marked symptom improvement.

  • PDF