• Title/Summary/Keyword: triangular structure

Search Result 313, Processing Time 0.03 seconds

Evaluation of the Structural Performance of Tetragonal Lattice Girders (사각 격자지보의 구조 성능 평가)

  • Kim, Seung-Jun;Han, Keum-Ho;Won, Deok-Hee;Baek, Jung-Sik;Kang, Young-Jong
    • Journal of Korean Society of Steel Construction
    • /
    • v.24 no.3
    • /
    • pp.267-278
    • /
    • 2012
  • In general, the H-shaped steel ribs or triangular lattice girders have been mostly used in constructing tunnels through the NATM construction method. The H-shaped steel rib has higher flexural and axial strength than the triangular lattice girder, but many unexpected gaps can occur in the concrete lining system after shotcreting if the H-shaped steel rib is used as the support system. To achieve better shotcreting quality, the triangular lattice girder was developed. However, in general, the triangle lattice girder has low flexural and axial strength. Likewise, the triangular lattice girder, which has circular sectional members, has so many fractures from welded points at the joints between the members. Finally, the new type of tetragonal lattice girder was developed to overcome those problems. In this study, the structural performance of the tetragonal lattice girders was evaluated through analytical and experimental studies. In the analytical studies, the four-point bending analysis, the traditional evaluation method to determine the flexural strength of the lattice girder, was performed. Moreover, the linear-elastic analysis and stability analysis of the arch structure made by the lattice girders were performed to measure structural performance. Experiments were likewise performed to compare the structural performances of the tetragonal girder with traditional triangular lattice girders.

Building Height Extraction using Triangular Vector Structure from a Single High Resolution Satellite Image (삼각벡터구조를 이용한 고해상도 위성 단영상에서의 건물 높이 추출)

  • Kim, Hye-Jin;Han, Dong-Yeob;Kim, Yong-Il
    • Korean Journal of Remote Sensing
    • /
    • v.22 no.6
    • /
    • pp.621-626
    • /
    • 2006
  • Today's commercial high resolution satellite imagery such as IKONOS and QuickBird, offers the potential to extract useful spatial information for geographical database construction and GIS applications. Extraction of 3D building information from high resolution satellite imagery is one of the most active research topics. There have been many previous works to extract 3D information based on stereo analysis, including sensor modelling. Practically, it is not easy to obtain stereo high resolution satellite images. On single image performance, most studies applied the roof-bottom points or shadow length extracted manually to sensor models with DEM. It is not suitable to apply these algorithms for dense buildings. We aim to extract 3D building information from a single satellite image in a simple and practical way. To measure as many buildings as possible, in this paper, we suggested a new way to extract building height by triangular vector structure that consists of a building bottom point, its corresponding roof point and a shadow end point. The proposed method could increase the number of measurable building, and decrease the digitizing error and the computation efficiency.

Behaviour factor and displacement estimation of low-ductility precast wall system under seismic actions

  • Tiong, Patrick L.Y.;Adnan, Azlan;Hamid, Nor H.A.
    • Earthquakes and Structures
    • /
    • v.5 no.6
    • /
    • pp.625-655
    • /
    • 2013
  • This paper investigated the seismic behaviour of an innovated non-ductile precast concrete wall structural system; namely HC Precast System (HCPS). The system comprises load-bearing precast wall panels merely connected only to column at both ends. Such study is needed because there is limited research information available in design codes for such structure particularly in regions having low to moderate seismicity threats. Experimentally calibrated numerical model of the wall system was used to carry out nonlinear pushover analyses with various types of lateral loading patterns. Effects of laterally applied single point load (SPL), uniformly distributed load (UDL), modal distributed load (MDL) and triangular distributed load (TDL) onto global behaviour of HCPS were identified. Discussion was focused on structural performance such as ductility, deformability, and effective stiffness of the wall system. Thus, a new method for engineers to estimate the nonlinear deformation of HCPS through linear analysis was proposed.

Modified Delaunay Triangulation Based on Data Structure of Geometric Modeller (형상 모델러의 자료구조에 의한 수정 Delaunay 삼각화)

  • Chae E.-M.;Sah J.-Y.
    • Journal of computational fluids engineering
    • /
    • v.2 no.2
    • /
    • pp.97-103
    • /
    • 1997
  • A modified Delaunay triangulation technique is tested for complicated computational domain. While a simple geometry. both in topology and geometry, has been well discretized into triangular elements, a complex geometry having difficulty in triangulation had to be divided into small sub-domains of simpler shape. The present study presents a modified Delaunay triangulation method based on the data structure of geometric modeller. This approach greatly enhances the reliability of triangulation, especially in complicated computational domain. We have shown that efficiency of Delaunay triangulation can be much improved by using both the GUI (Graphic User Interface) and OOP (Object-Oriented Programming).

  • PDF

LGE's Strategy for PDP TV

  • Kim, Jae-Sung;Lee, Sung-Hyun;Ahn, Sung-Yong;Ahn, Young-Joon;Ryu, Jae-Hwa;Yoon, Kwang-Ho
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07a
    • /
    • pp.71-74
    • /
    • 2005
  • There have been various efforts to achieve a better PDP TV, which have low power consumption, high image quality and low price. As the results, the power consumption of LG's new 42 inch HD PDP could be lower than 42 inch LCD under the general movie display load condition. And the address discharge time lag of ${\sim}1\;{\mu}s$ for 42 and 50 inch XGA single scan by which the cost can be reduced and image quality can be improved was achieved by using new MgO material and driving waveform. In addition, we have suggested TCA (Triangular Color pixel Arrangement) cell structure for realizing the full HDTV of 60inch diagonal size, which has $1920{\times}1080$ resolution. The luminous efficiency of the suggested TCA structure has been increased about 40% compared with that of the conventional cell structure.

  • PDF

Design and Analysis of Multi Beam Space Optical Mixer

  • Lian Guan;Zheng Yang
    • Current Optics and Photonics
    • /
    • v.8 no.1
    • /
    • pp.56-64
    • /
    • 2024
  • In response to the current situation where general methods cannot effectively compensate for the phase delay of ordinary optical mixers, a multi-layer spatial beam-splitting optical mixer is designed using total reflection triangular prisms and polarization beam splittings. The phase delay is generated by the wave plate, and the mixer can use the existing parallel plates in the structure to individually compensate for the phase of the four output beams. A mixer model is established based on the structure, and the influence of the position and orientation of the optical components on the phase delay is analyzed. The feasibility of the phase compensation method is simulated and analyzed. The results show that the mixer can effectively compensate for the four outputs of the optical mixer over a wide range. The mixer has a compact structure, good performance, and significant advantages in phase error control, production, and tuning, making it suitable for free-space coherent optical communication systems.

Design of Triangular-Patch Type Low Pass Filter (삼각패치형 저역 통과 여파기의 구현)

  • Oh, Song-Yi;Hwang, Hee-Yong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.3
    • /
    • pp.355-360
    • /
    • 2012
  • In this paper, an stepped-impedance low pass filter(SI-LPF) of triangular-patch type is proposed. A SI-LPF designed according to the standard SI-LPF design procedure is folded as a right angled triangle. The figure of merits of this structure are the adjustabilities of the cut off frequency, the stopband and the attenuation pole frequency of the proposed LPF by varying the resultant slots after folding the SI-LPF compactly for miniaturization. The size of the fabricated LPF is $13.75mm{\times}6.875mm$, which is 24.4 % reduced one compared to that of the conventional SI-LPF. The measured results of the LPF show return loss of less than -10 dB at passband, insertion loss of less than -10 dB at stopband and wide stopband from 3.5 GHz to 10 GHz (about $3f_c$).

A Study on the Sloshing Impact Response Analysis for the Insulation System of Membrane Type LNG Cargo Containment System (LNG 탱크 방열구조의 슬로싱 충격 응답 해석법에 관한 연구)

  • Nho, In-Sik;Ki, Min-Seok;Lee, Jae-Man;Kim, Sung-Chan
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.531-538
    • /
    • 2011
  • To ensure the structural integrity of membrane type LNG tank, the rational assessment of impact pressure and structural responses due to sloshing should be preceded. The sloshing impact pressures acting on the insulation system of LNG tank are typical irregular loads and the structural responses caused by them also very complex behaviors including fluid structure interaction. So it is not easy to estimate them accurately and huge time consuming process would be necessary. In this research, a simplified method to analyze the dynamic structural responses of LNG tank insulation system under pressure time histories obtained by sloshing model test or numerical analysis was proposed. This technique basically based on the concept of linear combination of the triangular response functions which are obtained by the transient response analysis under the unit triangular impact pressure acting on structures in time domain. The validity of suggested method was verified through the example calculations and applied to the structural analysis of real Mark III type insulation system using the sloshing impact pressure time histories obtained by model test.

  • PDF

A CPW-Fed Ultra-Wideband Planar Monopole Antenna for UHF Band Applications (UHF 대역용 CPW 급전 초광대역 평면형 모노폴 안테나)

  • Yoo, Tae-Hoon;Kim, Tae-Hyung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.7
    • /
    • pp.761-767
    • /
    • 2012
  • In this paper, a novel ultra-wideband planar monopole antenna for the UHF communications and Digital-TV reception is proposed. The proposed antenna fed by a coplanar waveguide(CPW) is based on a triangular patch that has a broadband characteristic. To further increase the bandwidth of the triangular patch antenna, the top side of the regular triangular patch is loaded with a notch cut and each oblique side with a step. In addition, a slope is given to the ground plane of the CPW structure. Experimental results show that the -10 dB return loss bandwidth of the proposed antenna is 2,320 MHz from 480~2,800 MHz(5.83:1 bandwidth), which covers all the frequency bands of the various wireless communication systems and Digital TV broadcasting in the UHF band. Within the entire operating frequency range, the measured antenna gain in y-z plane(E-plane) varies from 3.01 to 4.71 dBi.

ON A CLASS OF GENERALIZED TRIANGULAR NORMS

  • Jebril, Iqbal;Raissouli, Mustapha
    • Communications of the Korean Mathematical Society
    • /
    • v.32 no.2
    • /
    • pp.353-359
    • /
    • 2017
  • Starting from a t-norm T, it is possible to construct a class of new t-norms, so-called T-generalized t-norm. The purpose of this paper is to describe some properties of this class of generalized t-norms. An algebraic structure as well as a binary relation among t-norms are also investigated. Some open problems are discussed as well.