• Title/Summary/Keyword: treatment planning

Search Result 1,832, Processing Time 0.033 seconds

Inter-fractional Target Displacement in the Prostate Image-Guided Radiotherapy using Cone Beam Computed Tomography (전립선암 영상유도 방사선 치료시 골반내장기의 체적변화에 따른 표적장기의 변화)

  • Dong, Kap Sang;Back, Chang Wook;Jeong, Yun Jeong;Bae, Jae Beom;Choi, Young Eun;Sung, Ki Hoon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.2
    • /
    • pp.161-169
    • /
    • 2016
  • Purpose : To quantify the inter-fractional variation in prostate displacement and their dosimetric effects for prostate cancer treatment. Materials and Methods : A total of 176 daily cone-beam CT (CBCT) sets acquired for 6 prostate cancer patients treated with volumetric-modulated arc therapy (VMAT) were retrospectively reviewed. For each patient, the planning CT (pCT) was registered to each daily CBCT by aligning the bony anatomy. The prostate, rectum, and bladder were delineated on daily CBCT, and the contours of these organs in the pCT were copied to the daily CBCT. The concordance of prostate displacement, deformation, and size variation between pCT and daily CBCT was evaluated using the Dice similarity coefficient (DSC). Results : The mean volume of prostate was 37.2 cm3 in the initial pCT, and the variation was around ${\pm}5%$ during the entire course of treatment for all patients. The mean DSC was 89.9%, ranging from 70% to 100% for prostate displacement. Although the volume change of bladder and rectum per treatment fraction did not show any correlation with the value of DSC (r=-0.084, p=0.268 and r=-0.162, p=0.032, respectively), a decrease in the DSC value was observed with increasing volume change of the bladder and rectum (r=-0.230,p=0.049 and r=-0.240,p=0.020, respectively). Conclusion : Consistency of the volume of the bladder and rectum cannot guarantee the accuracy of the treatment. Our results suggest that patient setup with the registration between the pCT and daily CBCT should be considered aligning soft tissue.

  • PDF

The feasibility evaluation of Respiratory Gated radiation therapy simulation according to the Respiratory Training with lung cancer (폐암 환자의 호흡훈련에 의한 호흡동조 방사선치료계획의 유용성 평가)

  • Hong, mi ran;Kim, cheol jong;Park, soo yeon;Choi, jae won;Pyo, hong ryeol
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.2
    • /
    • pp.149-159
    • /
    • 2016
  • Purpose : To evaluate the usefulness of the breathing exercise,we analyzed the change in the RPM signal and the diaphragm imagebefore 4D respiratory gated radiation therapy planning of lung cancer patients. Materials and Methods : The breathing training was enforced on 11 patients getting the 4D respiratory gated radiation therapy from April, 2016 until August. At the same time, RPM signal and diaphragm image was obtained respiration training total three steps in step 1 signal acquisition of free-breathing state, 2 steps respiratory signal acquisition through the guide of the respiratory signal, 3 steps, won the regular respiration signal to the description and repeat training. And then, acquired the minimum value, maximum value, average value, and a standard deviation of the inspiration and expiration in RPM signal and diaphragm image in each steps. Were normalized by the value of the step 1, to convert the 2,3 steps to the other distribution ratio (%), by evaluating the change in the interior of the respiratory motion of the patient, it was evaluated breathing exercise usefulness of each patient. Results : The mean value and the standard deviation of each step were obtained with the procedure 1 of the RPM signal and the diaphragm amplitude as a 100% reference. In the RPM signal, the amplitudes and standard deviations of four patients (36.4%, eleven) decreased by 18.1%, 27.6% on average in 3 steps, and 2 patients (18.2%, 11 people) had standard deviation, It decreased by an average of 36.5%. Meanwhile, the other four patients (36.4%, eleven) decreased by an average of only amplitude 13.1%. In Step 3, the amplitude of the diaphragm image decreased by 30% on average of 9 patients (81.8%, 11 people), and the average of 2 patients (18.2%, 11 people) increased by 7.3%. However, the amplitudes of RPM signals and diaphragm image in 3steps were reduced by 52.6% and 42.1% on average from all patients, respectively, compared to the 2 steps. Relationship between RPM signal and diaphragm image amplitude difference was consistent with patterns of movement 1, 2 and 3steps, respectively, except for No. 2 No. 10 patients. Conclusion : It is possible to induce an optimized respiratory cycle when respiratory training is done. By conducting respiratory training before treatment, it was possible to expect the effect of predicting the movement of the lung which could control the patient's respiration. Ultimately, it can be said that breathing exercises are useful because it is possible to minimize the systematic error of radiotherapy, expect more accurate treatment. In this study, it is limited to research analyzed based on data on respiratory training before treatment, and it will be necessary to verify with the actual CT plan and the data acquired during treatment in the future.

  • PDF

Control of Microorganisms in School Refectories and Kitchens Using Ozone Water and Ozone Gas (오존수 및 오존가스를 이용한 학교급식에서의 미생물 제어)

  • Choi, Jin-Kyung;Shin, Il-Shik;Kim, Dae Uk;Kim, Hee-Yun
    • Korean Journal of Food Science and Technology
    • /
    • v.47 no.5
    • /
    • pp.586-592
    • /
    • 2015
  • This study was performed to determine optimum approaches for control of microorganisms in school refectories and kitchens. A reduction of more than 5.0 log CFU/mL was noted for Escherichia coli O157:H7, Salmonella Typhimurium, Listeria monocytogenes, Staphylococcus aureus, and Streptococcus mutans after treatment with 5 ppm ozone water for 60 s. Treatment of different vegetables with ozone water for 5 min showed bactericidal effects with 2-4 log reduction of viable cell number; the bactericidal effects differed according to the kinds of vegetables. The viable cell number on kitchen apparatus and tableware was not detected by ozone water treatment for 60 s. In addition, the count of the bacteria floating in the air in refectories and kitchens decreased 2.0 log CFU/1,000 L air to 0-1 CFU/1,000 L air on treatment with 45 ppm ozone gas for 12 hr. Therefore, ozone water and ozone gas may be good candidates as antimicrobial agents that can be used to improve sanitary conditions in school refectories and kitchens.

Reading Deviations of Glass Rod Dosimeters Using Different Pre-processing Methods for Radiotherapeutic in-vivo Dosimetry (유리선량계의 전처리 방법이 방사선 치료 선량 측정에 미치는 영향)

  • Jeon, Hosang;Nam, Jiho;Park, Dahl;Kim, Yong Ho;Kim, Wontaek;Kim, Dongwon;Ki, Yongkan;Kim, Donghyun;Lee, Ju Hye
    • Progress in Medical Physics
    • /
    • v.24 no.2
    • /
    • pp.92-98
    • /
    • 2013
  • The experimental verification of treatment planning on the treatment spot is the ultimate method to assure quality of radiotherapy, so in-vivo skin dose measurement is the essential procedure to confirm treatment dose. In this study, glass rod dosimeter (GRD), which is a kind of photo-luminescent based dosimeters, was studied to produce a guideline to use GRDs in vivo dosimetry for quality assurance of radiotherapy. The pre-processing procedure is essential to use GRDs. This is a heating operation for stabilization. Two kinds of pre-processing methods are recommended by manufacturer: a heating method (70 degree, 30 minutes) and a waiting method (room temperature, 24 hours). We equally irradiated 1.0 Gy to 20 GRD elements, and then different preprocessing were performed to 10 GRDs each. In heating method, reading deviation of GRDs at same time were relatively high, but the deviation was very low as time went on. In waiting method, the deviation among GRDs was low, but the deviation was relatively high as time went on. The meaningful difference was found between mean reading values of two pre-processing methods. Both methods present mean dose deviation under 5%, but the relatively high effect by reading time was observed in waiting method. Finally, GRD is best to perform in-vivo dosimetry in the viewpoint of accuracy and efficiency, and the understanding of how pre-processing affect the accuracy is asked to perform most accurate in-vivo dosimetry. The further study is asked to acquire more stable accuracy in spite of different irradiation conditions for GRD usage.

The Usability Analysis of 3D-CRT, IMRT, Tomotherpy Radiation Therapy on Nasopharyngeal Cancer (NPC의 방사선치료시 3D-CRT, IMRT, Tomotherapy의 유용성 분석)

  • Song, Jong-Nam;Kim, Young-Jae;Hong, Seung-Il
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.5
    • /
    • pp.365-371
    • /
    • 2012
  • The radiation therapy treatment technique is developed from 3D-CRT, IMRT to Tomotherapy. and these three technique was most widely using methods. We find out a comparison normal tissue doses and tumor dose of 3D-CRT, IMRT(Linac Based), and Tomotherapy on Head and Neck Cancer. We achieved radiological image used the Human model phantom (Anthropomorphic Phantom) and it was taken CT simulation (Slice Thickness : 3mm) and GTV was nasopharngeal region and PTV(including set-up margin) was GTV plus 2mm area. and transfer those images to the radiation planning system (3D-CRT - ADAC-Pinnacle3, Tomotherapy - Tomotherapy Hi-Art System). The prescription dose was 7020 cGy and measuring PTV's dose and nomal tissue (parotid gland, oral cavity, spinal cord). The PTV's doses was Tomotherapy, Linac Based - IMRT, 3D-CRT was 6923 cGy, 6901 cGy and 6718 cGy its dose value was meet TCP because its value was up to the 95% based on 7020 cGy, Nomal tissue (parotid gland, oral cavity, spinal cord) was 1966 cGy(Tomotherapy), 2405 cGy(IMRT), 2468 cGy(3D-CRT)[parotid gland], 2991 cGy(Tomotherapy), 3062 cGy(IMRT), 3684 cGy (3D-CRT)[oral cavity], 1768 cGy(Tomotherapy), 2151 cGy(IMRT), 4031 cGy(3D-CRT)[spinal cord] its value did not exceeded NTCP. All the treatment techniques are equated with tumor and nomal tissue doses. The 3D-CRT was worse than other techniques on dose distribution, but it is reasonable in terms of TCP and NTCP baseline Tomotherapy, IMRT -dose distribution was relatively superior- was hard to therapy to claustrophobic patients and patients with respiratory failure. Particularly, in case on Tomotherapy, it take MVCT before treatment so dose measurement will be unnecessary radiation exposure to patients. Conclusion, Tomotherapy was the best treatment technique and 2nd was IMRT, and 3rd 3D-CRT. But applicable differently depending on the the patient's condition even though dose not matter.

Influence of the Composition and Concentration of Fertilizer Solution on Growth and Nutrient Uptake of 'Maehyang' Strawberry during Vegetative Growth (비료의 조성 및 농도가 영양생장 중인 '매향' 딸기의 생장, 양분흡수 및 근권환경 변화에 미치는 영향)

  • Jang, Hyun Ho;Lee, Hee Su;Lee, Chiwon W.;Choi, Jong Myung
    • Horticultural Science & Technology
    • /
    • v.32 no.4
    • /
    • pp.484-492
    • /
    • 2014
  • We quantified the effects of the composition and concentration of fertilizer solutions on the growth and nutrient uptake of 'Maehyang' strawberry at the vegetative growth stage. Acid fertilizer (AF), neutral fertilizer (NF), and basic fertilizer (BF) with concentrations of 100 or $200mg{\cdot}L^{-1}$ based on N, were formulated and applied during the 100 days after transplanting, at which point crop growth and tissue nutrient contents were analyzed. The soil solutions were sampled every two weeks to measure the pH, EC and nutrient concentrations. BF was a more effective fertilizer compared to AF and NF for growth of 'Maehyang' strawberry when fertilizer concentrations were controlled to $100mg{\cdot}L^{-1}$. By contrast, the fresh and dry weights were greatest in the NF treatment when fertilizer concentrations were controlled to $200mg{\cdot}L^{-1}$. The tissue contents of N, P, and Na were 2.20, 0.51 and 0.10%, respectively, in the NF 200 treatment, and these were the highest among all treatments tested. The highest contents of K, Ca and Mg were 2.60% in AF 200, 0.95% in BF 200 and 0.45% in BF 100, respectively. During the fertilization period, the highest and lowest pHs were 6.13 in BF 100 and 4.92 in AF 200. The lowest EC was $1.376dS{\cdot}m^{-1}$ in BF 100 and the highest was $4.936dS{\cdot}m^{-1}$ in NF 200 treatments. The highest $NH_4{^+}$ concentrations in the soil solution occurred during the AF 200 treatment, followed by those with NF 200 and AF 100. When fertilizer concentrations were equal, AF treatment gave rise to the highest $Ca^{+2}$ and $Mg^{+2}$ concentrations, followed by NF and BF, until day 84 of fertilization. The BF treatments had the highest $NO_3{^-}$ concentrations followed by NF and AF. The trends for $PO_4^{-3}$ concentrations were similar in all fertilizer treatments when the fertilizer concentrations were equal. The above results indicate that neutral and basic fertilizers were most effective to promote 'Maehyang' strawberry growth when fertilizer solutions were controlled to low or high concentrations, respectively. These findings are useful for planning fertilization programs for vegetative propagation of 'Maehyang' strawberry.

Palliative Irradiation Using Helical Tomotherapy in Recurrent Pelvic Tumors with Prior Radiotherapy (방사선치료 후 재발한 골반암에서 토모테라피를 이용한 고식적 재치료)

  • Kay, Chul-Seung;Yoo, Eun-Jung;Kim, Ji-Hoon;Ro, Duck-Young;Kim, Ki-Jun
    • Radiation Oncology Journal
    • /
    • v.28 no.3
    • /
    • pp.133-140
    • /
    • 2010
  • Purpose: We retrospectively investigated the effect of irradiation using helical tomotherapy in recurrent pelvic tumors that underwent prior irradiation. Materials and Methods: Fourteen patients with recurrent pelvic tumors consisting of rectal cancer (57.1%), cervical cancer (35.7%) and cancer with an unknown origin (7.1%) were treated with tomotherapy. At the time of irradiation, median tumor size was 3.5 cm and 7 patients complained of pain originating from a recurrent tumor. The median radiation dose delivered to the gross tumor volume, clinical target volume, and planning target volume was 50 Gy, 47.8 Gy and 45 Gy, respectively and delivered at 5 fractions per week over the course of 4 to 5 weeks. Treatment response and duration of local disease control were evaluated using the Response Evaluation Criteria in Solid Tumors (ver. 1.0) and the Kaplan-Meyer method. Treatment-related toxicities were assessed through Common Terminology Criteria for Adverse Events (ver. 3.0). Results: The median follow-up time was 17.3 months, while the response rate was 64.3%. Symptomatic improvement appeared in 6 patients (85.7%). The median duration time of local disease control was 25.8 months. The rates of local failure, distant failure, and synchronous local and distant failure were 57.1%, 21.4%, and 7.1%, respectively. Acute toxicities were limited in grade I or II toxicities, except for one patient. No treatment related death or late toxicity was observed. Conclusion: Helical tomotherapy could be suggested as a feasible palliative option in recurrent pelvic tumors with prior radiotherapy. However, to increase treatment effect and overcome the limitation of this outcome, a large clinical study should be performed.

Study of Radiological Approach to Treat a Chronic Constipation (만성변비환자의 방사선학적 접근방법에 관한 고찰)

  • Yoon, Seok-Hwan
    • Journal of radiological science and technology
    • /
    • v.27 no.3
    • /
    • pp.5-12
    • /
    • 2004
  • I. Introduction : The constipation is one of the common gastrointestinal symptoms seen in the clinical practice. When people come to the clinic complaining of the constipation, it is generally one of the cases of infrequent, painful or difficult evacuation as well as the hardened feces and unsatisfactory evacuation sense. Since the constipation is heavily influenced by dietary habit as well as the social and medical environment, the diagnostic radiology is useful to establish the objective and standardized definition in consideration of those various factors before diagnosis and treatment of the constipation patient. This paper describes the study of such diagnosis. II. Main Subject : Testing of CTT (colon transit time) is key study of the colon performance. CTT is very helpful in classifying the pathologic physiological types and defining the treatment plan for the chronic constipation. The study methods include using the radipaque marker, multiple marker technique and scintigraphic measurement. The defecography is the functional radiologic examination a that provides not only the anatomical information of anorectal but also performance of the pelvic floor and rectal change during evacuation. Study of dynamic movement of the anorectal during evacuation is helpful for diagnosis and treatment planning as well as follow-up testing for the constipation patient. One of the issues essential for the case history is the thorough observation of whether the patient shows the psychic psychological symptoms such as the behavior disorder or emotional disturbance. In that case, the decision must be made whether or which type of medication is needed for such psychiatric problem. III. Conclusion : The main causes of the constipation are insufficient intake of fiber or liquid. The key objective of such tests is to check etiology of the constipation. In general, the radiological examination does not provde the colon or anorectal performance information. It is envisaged that this study will provide the information to decide the testing and treatment plans and predict the prognosis of the patient by classifying the pathologic physiological types.

  • PDF

Positional Change of the Uterus during Definitive Radiotherapy for Cervix Cancer (자궁경부암의 방사선치료 시 자궁의 크기와 위치 변화)

  • Park, Won;Huh, Seung-Jae;Lee, Jeung-Eun
    • Radiation Oncology Journal
    • /
    • v.21 no.2
    • /
    • pp.135-142
    • /
    • 2003
  • Purpose: The purpose of this study was to investigate the positional change of the uterus during radiotherapy. Materials and Methods: Between 1997 and 2001, 47 patients received definitive radiotherapy for cervical cancer at the Samsung Medical Center. For each patient, two MRI scans were taken; one before and the other 3$\~$4 weeks after the radiotherapy treatment. In T2 weighted MRI images, the positional change of the uterine was quantified by measuring six quantities; the distance from the cervix os to the isthmus of the uterus (Dcx), the maximum length from the isthmus of the uterus to the uterine fundus (Dco), the maximum vertical distance of the uterine body (Dco-per), the angle between the vertical line and the cervical canal in the sagittal images (Acx), the angle of the uterine corpus from the vertical line in the sagittal plan (Aco-ap), and the relative angle of the uterine corpus from a fixed anatomical landmark in the axial images (Aco-axi). Results: The mean Dcx values, before and during the treatment, were 36.7 and 27.8 mm, respectively. The Dco deviated by more than 10 mm in 14 cases (29.8$\%$). The change in the Acx ranged from 0.1 to 67.8$^{\circ}$ (mean 13.2$^{\circ}$). The Aco-ap changed by a maximum of 84.8$^{\circ}$ (mean 16.9$^{\circ}$). The differences in the Dcx plus the Dco in the smaller (<4 cm) and larger ($geq$4 cm) tumors were 5.3 and 19.4 mm, respectively. With patients less than 60 years old, or with a tumor size larger than 4 cm, the difference in the Acx was statistically significant. Conclusion: The positional changes of the uterus, during radiation treatment, should be considered in the 3DCRT or IMRT treatment planning, particularly in patients under 60 years of age or in those with a tumor size greater than 4 cm in maximum diameter.

Preference and Performance Fidelity of Modified Korean Physician Order for Life-Sustaining Treatment (MK-POLST) Items in Hospice Patients with Cancer (수정된 한글 연명의료계획서(Modified Korean Physician Order for Life-Sustaining Treatment, MK-POLST) 분석을 통한 호스피스 병동 환자의 의료 중재 항목별 선호도 및 충실도 조사)

  • Han, Ji Hee;Chun, Hye Sook;Kim, Tae Hee;Kim, Rock Bum;Kim, Jung Hoon;Kang, Jung Hun
    • Journal of Hospice and Palliative Care
    • /
    • v.22 no.4
    • /
    • pp.198-206
    • /
    • 2019
  • Purpose: The Act on Hospice and Palliative Care and Decisions on Life-sustaining Treatment for Patients at the End of Life was enacted in 2016 and has taken effect since 2018 February. The content of this act was based on Physician Orders for Life-Sustaining Treatment (POLST) in the United States and we modified it for terminal cancer patients registering hospice. The object of this study is to investigate preference and implementation rate for modified Korean POLST (MMK-POLST) items in hospice ward. Methods: From February 1, 2017 to April 30, 2019, medical records regarding MMK-POLST were retrospectively analyzed for all patients hospitalized in the hospice ward of Gyeongsang National University Hospital. Results: Of the eligible 387 total cohorts, 295 patients filled out MK-POLST. MK-POLST has been completed in 133 cases (44.1%) by the patient themselves, 84 cases (28.5%) by the spouse, and 75 cases (25.4%) by their children, respectively. While only 13 (4.4%) out of 295 MK-POLST completed patients refused the parenteral nutrition and 5 patients (1.7%) for palliative sedation, the absolute majority of 288 (97.6%) patients did not want cardiopulmonary resuscitation (CPR) and ventilators and 226 people (76.9%) for pressor medications. Kappa values for the matched strength of MK-POLST implementation were poor for all items except CPR, ventilators and palliative sedation. Conclusion: Hospice patients refused to conduct cardiopulmonary resuscitation, ventilators and pressor agents. In contrast, antibiotics, parenteral nutrition and palliative sedation were favored in the majority of patients.