• Title/Summary/Keyword: treatment of choice

Search Result 1,224, Processing Time 0.023 seconds

Dosimetric Characteristics of Detectors in Measurement of Beam Data for Small Fields of Linear Accelerator (선형가속기의 소조사면에 대한 빔 자료 측정에서 검출기의 선량 특성 분석)

  • Koo, Ki-Lae;Yang, Oh-Nam;Lim, Cheong-Hwan;Choi, Won-Sik;Shin, Seong-Soo;Ahn, Woo-Sang
    • Journal of radiological science and technology
    • /
    • v.35 no.3
    • /
    • pp.265-273
    • /
    • 2012
  • Aquisition of accurate beam data is very important to calculate a reliable dose distribution of the treatment planning system for small radiation fields in intensity-modulated radiation therapy(IMRT) and stereotactic radiosurgery(SRS). For the measurement of small fields, the choice of a suitable detector is important due to the shape gradient in profile penumbra, the lack of lateral electronic equilibrium, and the effect of effective detector volume. Therefore, this study was to analyze the dosimetric characteristics of various detectors in measurement of beam data for small fields of linear accelerator. 0.01cc and 0.13cc ion chambers (CC01 and CC13) and a stereotactic diode detector(SFD) were used for measurement of small fields. The beam data, including the percent depth dose, output factor, and beam profile were acquired under 6 MV and 15 MV photon beams. Measurements were performed with the field size ranging from $2{\times}2cm^2$ to $5{\times}5cm^2$. For $2{\times}2cm^2$ field size, the differences of the ratios of $PDD_{20}$ and $PDD_{10}$ measured by CC01 and SFD detectors were 1.02% and 0.12% for 6 MV and 15 MV photon beams, respectively. For field sizes larger than $3{\times}3cm^2$, the differences of values of $PDD_{20}/PDD_{10}$ obtained from each detector were 1.15% and 0.71% for 6 MV and 15 MV photon beams, respectively. The output factors obtained from CC01 and SFD for $2{\times}2cm^2$ field size were within 0.5% and 1.5% for 6 MV and 15 MV, respectively. The differences in output factor of three detectors for $3{\times}3cm^2$ to $5{\times}5cm^2$ field sizes were within 0.5%. Profile penumbras measured by the SFD, CC01, and CC13 detectors at three depths were average 2.7 mm and 3.5 mm, 3.4 mm and 4.3 mm, and 5.2 mm and 6.1 mm for 6 MV and 15 MV photon beams, respectively. In conclusion, it could be possible to use of the CC01 and SFD detectors for the measurement of percent depth dose and output factor for $2{\times}2cm^2$ field size, and to use of three detectors for $3{\times}3cm^2$ to $5{\times}5cm^2$ field sizes. CC01 and SFD detectors, consider ably smaller than the radiation field, should be used in order to accurately measure the profile penumbra for small field sizes.

The Expression of Adhesion Molecules on BAL Cells and Serum Soluble ICAM-1 Level after the Radiotherapy for the Lung Cancer and Its Relationship to the Development of of Radiation Pneumonitis and Fibrosis (방사선 치료후 기관지-폐포세척액내 폐포대식세포 및 임파구의 접착분자발현 변화와 방사선에 의한 폐렴 및 폐섬유증발생의 예측인자로서의 의의)

  • Kim, Dong-Soon;Paik, Sang-Hoon;Choi, Eun-Kyung;Chang, Hye-Sook;Choi, Jung-Eun;Lim, Chae-Man;Koh, Yun-Suck;Lee, Sang-Do;Kim, Woo-Sung;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.1
    • /
    • pp.75-87
    • /
    • 1996
  • Background: Lung cancer is the second most frequent malignancy in man in Korea. Surgery is the best treatment modality for non-small cell lung cancer, but most patients were presented in far advanced stage. So radiation therapy(RT) with or without chemotherapy is the next choice and radiation-induced pneumonitis and pulmonary fibrosis is the major limiting factor for the curative RT. Radiation pneumonitis is manifested with fever, cough and dyspnea, 2~3 months after the termination of radiotherpy. Chest X ray shows infiltration, typically limited to the radiation field, but occasionally bilateral infiltration was reported. Also Gibson et al reported that BAL lymphocytosis was found in both lungs, even though the radiation was confined to one lung. The aim of this study is to investigate the change of adhesion molecules expression on BAL cells and serum soluble ICAM-1(sICAM-1) level after the RT and its relationship to the development of radiation pneumonitis. The second aim is to confirm the bilaterality of change of BAL cell pattern and adhesion molecule expression. Subjects: BAL and the measurement of sICAM level in serum and BALF were done on 29 patients with lung cancer who received RT with curative intention. The BAL was done before the RT in 16 patients and 1~2 month after RT in 18 patients. 5 patients performed BAL before and after RT. Result: Clinically significant radiation pneumonitis developed in 7 patients. After RT, total cell count in BAL was significantly increased from $(20.2{\pm}10.2){\times}10^6\;cells/ml$ to $(35.3{\pm}21.6){\times}10^6\;cells/ml$ (p=0.0344) and %lymphocyte was also increased from $5.3{\pm}4.2%$ to $39.6{\pm}23.4%$ (p=0.0001) in all patient group. There was no difference between ipsilateral and contraleteral side to RT, and between the patients with and without radiation-pneumonitis. In whole patient group, the level of sICAM-1 showed no significant change after RT(in serum: $378{\pm}148$, $411{\pm}150\;ng/ml$, BALF: $20.2{\pm}12.2$, $45.1{\pm}34.8\;ng/ml$, respectively), but there was a significant difference between the patients with pneumonitis and without pneumonitis (serum: $505{\pm}164$ vs $345{\pm}102\;ng/ml$, p=0.0253, BALF: $67.9{\pm}36.3$ vs $25.2{\pm}17.9\;ng/ml$, p=0.0112). The expression of ICAM-1 on alveolar macrophages (AM) tends to increase after RT (RMFI: from $1.28{\pm}0.479$ to $1.63{\pm}0.539$, p=0.0605), but it was significantly high in patients with pneumonitis ($2.10{\pm}0.390$) compared to the patients without pneumonitis ($1.28{\pm}0.31$, p=0.0002). ICAM-1 expression on lymphocytes and CD 18 (${\beta}2$-integrin) expression tended to be high in the patients with pneumonitis but the difference was statiastically not significant. Conclusion: Subclinical alveolitis on the basis of BAL finding developed bilaterally in all patients after RT. But clinically significant pneumonitis occurred in much smaller fraction and the ICAM-1 expression on AM and the sICAM-1 level in serum were good indicator of it.

  • PDF

Effects of Applying Livestock Manure on Productivity and Feed Value of Corn and Sorghum$\times$Sorghum Hybrid (가축분뇨시용이 옥수수와 수수$\times$수수교잡종의 생산성 및 사료가치에 미치는 영향)

  • Jo, Ik-Hwan
    • Korean Journal of Organic Agriculture
    • /
    • v.16 no.1
    • /
    • pp.115-125
    • /
    • 2008
  • This study was conducted to determine adequate forage crop choice and optimal level of livestock manure, when different types and levels of the livestock manure were applied in corns or sorghum$\times$sorghum hybrids for the production of organic roughages by utilizing livestock manure. For the corn, yields of annual dry matter (DM) and total digestible nutrients (TDN) were highest in N+P+K-applied treatments, showing 17.3 and 11.7 ton/ha, respectively. Treatments applied 100% composted cattle manure (8.9 and 6.1 ton/ha) and 100% cattle slurry (9.4 and 7.5 ton/ ha) in contrast with chemical fertilizer-N had higher yields of DM and TDN than no fertilizer (4.8 and 2.7 ton/ha) and P+K-applied treatments (8.8 and 6.0 ton/ha). Particularly, treatments applied 150% composted cattle manure and 150% cattle slurry were markedly higher, which represented 11.4 and 7.6 ton/ha and 10.3 and 7.3 ton/ha, respectively. Crude protein (CP) contents for corns applied livestock manure ranged from 5.6 to 6.6%, which were significantly (p<0.05) higher than those of no fertilizer (3.9%) and P+K-applied treatments (5.5%). ADF (42.4%) and NDF (58.3%) contents for no fertilizer treatment were significantly (p<0.05) higher than those of other treatments. However, TDN contents were higher for livestock manure treatments than for no and/or chemical fertilizer treatments. In particular, TDN contents of treatments applied 150% composted cattle manure and 150% cattle slurry showed 72.3 and 70.8%, respectively and both treatments were significantly (p<0.05) higher than all of the other treatments. For the sorghum$\times$sorghum hybrid, yields of annual DM and TDN for 100% (12.4 and 7.4 ton/ha) and 150% (13.1 and 7.6 ton/ha) cattle slurry-applied treatments, and N+P+K-applied treatments (12.6 and 7.7 ton/ha) were significantly (p<0.05) higher than those of the others. In the others, 150% composted cattle manure (9.3 and 5.2 ton/ha) had higher annual DM and TDN yields than P+K-applied (8.4 and 4.8 ton/ha) and 100% composted cattle manure treatments (7.4 and 4.2 ton/ha), with no significant difference. Crude protein contents for sorghum$\times$sorghum hybrid applied P+K and cattle slurry were 8.8 and 8.6%, respectively. CP contents for both treatments were significantly higher than those of composted manure ($7.5{\sim}8.3%$) and no fertilizer (4.0%) treatments, but 100% livestock manure treatments had higher CP contents than 150%-applied treatments. ADF and NDF contents for N+P+K and cattle slurry-applied treatments were significantly (p<0.05) lower than the others. However, TDN contents were highest in N+P+K and cattle slurry-applied treatments, showing 61.2 and 58.3 to 59.4%, respectively. These results indicated that application of livestock manure instead of chemical fertilizer to the soil of forage crops might not only improve yields of DM and TDN, but also reduce environmental pollution by producing organic roughages through recycling of livestock manure.

  • PDF

Feasibility of Mixed-Energy Partial Arc VMAT Plan with Avoidance Sector for Prostate Cancer (전립선암 방사선치료 시 회피 영역을 적용한 혼합 에너지 VMAT 치료 계획의 평가)

  • Hwang, Se Ha;NA, Kyoung Su;Lee, Je Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.32
    • /
    • pp.17-29
    • /
    • 2020
  • Purpose: The purpose of this work was to investigate the dosimetric impact of mixed energy partial arc technique on prostate cancer VMAT. Materials and Methods: This study involved prostate only patients planned with 70Gy in 30 fractions to the planning target volume (PTV). Femoral heads, Bladder and Rectum were considered as oragan at risk (OARs). For this study, mixed energy partial arcs (MEPA) were generated with gantry angle set to 180°~230°, 310°~50° for 6MV arc and 130°~50°, 310°~230° for 15MV arc. Each arc set the avoidance sector which is gantry angle 230°~310°, 50°~130° at first arc and 50°~310° at second arc. After that, two plans were summed and were analyzed the dosimetry parameter of each structure such as Maximum dose, Mean dose, D2%, Homogeneity index (HI) and Conformity Index (CI) for PTV and Maximum dose, Mean dose, V70Gy, V50Gy, V30Gy, and V20Gy for OARs and Monitor Unit (MU) with 6MV 1 ARC, 6MV, 10MV, 15MV 2 ARC plan. Results: In MEPA, the maximum dose, mean dose and D2% were lower than 6MV 1 ARC plan(p<0.0005). However, the average difference of maximum dose was 0.24%, 0.39%, 0.60% (p<0.450, 0.321, 0.139) higher than 6MV, 10MV, 15MV 2 ARC plan, respectively and D2% was 0.42%, 0.49%, 0.59% (p<0.073, 0.087, 0.033) higher than compared plans. The average difference of mean dose was 0.09% lower than 10MV 2 ARC plan, but it is 0.27%, 0.12% (p<0.184, 0.521) higher than 6MV 2 ARC, 15MV 2 ARC plan, respectively. HI was 0.064±0.006 which is the lowest value (p<0.005, 0.357, 0.273, 0.801) among the all plans. For CI, there was no significant differences which were 1.12±0.038 in MEPA, 1.12±0.036, 1.11±0.024, 1.11±0.030, 1.12±0.027 in 6MV 1 ARC, 6MV, 10MV, 15MV 2 ARC, respectively. MEPA produced significantly lower rectum dose. Especially, V70Gy, V50Gy, V30Gy, V20Gy were 3.40, 16.79, 37.86, 48.09 that were lower than other plans. For bladder dose, V30Gy, V20Gy were lower than other plans. However, the mean dose of both femoral head were 9.69±2.93, 9.88±2.5 which were 2.8Gy~3.28Gy higher than other plans. The mean MU of MEPA were 19.53% lower than 6MV 1 ARC, 5.7% lower than 10MV 2 ARC respectively. Conclusion: This study for prostate radiotherapy demonstrated that a choice of MEPA VMAT has the potential to minimize doses to OARs and improve homogeneity to PTV at the expense of a moderate increase in maximum and mean dose to the femoral heads.