MF Membrane Application for Water Treatment in Japan

  • Okazaki, Minoru
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1995.10a
    • /
    • pp.80-93
    • /
    • 1995
  • Membrane Technology, which has been in use for over twenty five years, has established itself as one of the principle separation methods. With improved technology, Reverse Osmosis ("RO") has been applied to large volume water treatment facilities. UF and MF Membrane Technology has, up until recently, been applied to small scale water treatment facilities. The fouling of membrane has restricted the growth of Membrane Technology in Water Treatment. Membrane fouling compound found in water causes the loss of flux across the membrane by absorbing to membrane and plugging their pores. Various methods have been used in the reduction and prevention of membrane fouling. For RO, a conventional pre-treatment system removes the pollutants, preventing the function decline of RO membrane by keeping SDI < 4 as the standard condition of feed water. UF and MF Membrane Technology that must have pre-treatment function within itself, are required to keep its ability not to be influenced by fouling.y fouling.

  • PDF

An Analysis of Local Government's Intentions for Privatization Policy of Waste Treatment Facilities in Korea (생활폐기물처리시설 민영화 정책에 대한 지방자치단체 의사 분석)

  • Koo, Jakon;Kang, Mi-Youn;Seo, Yong-Chil;Sun, Jong-Keun;Yoon, Bora;Kim, Byung-Hoon
    • Journal of Environmental Impact Assessment
    • /
    • v.18 no.5
    • /
    • pp.257-270
    • /
    • 2009
  • The central government in Korea has pursued a policy to privatize municipal solid waste treatment facilities in order to enhance the effectiveness of public financial management in recent years. To understand the intentions of local governments on this policy, the survey with questionnaires on 37 out of 256 local governments was made in October, 2007. The results were analyzed and compared in 6 classified policy areas. The results showed that local government had enough financial status to operate the facilities with proper services and had the opinion with positive management in finance with increasing rate of prospective views. Among the facilities operated by local governments, the satisfaction levels for landfill(46.2%) and incineration(40.0%) were relatively higher. However those for recycling and food waste resource facilities were not satisfied with showing lower rate of satisfaction. The priority of privatization in consideration among them were following in order of food waste resource plants(76.2%), incinerators(63.6%), and recycling facilities(53.9%) and the most considerable reason to privatize them was due to resolve financial problems(59.7%). They thought and expected that the privatization would provide cost reduction effects in local governments and also be easier to achieve the environmental goals. To enhance such privatization, expanding more incentives by central government would be essential as shown in the investigation of this survey.

A Study on the Regulatory Effect of the Special Water Preservation Area of Lake Paldang Watershed Based on Long-Term Variation of Pollutant Source and Water Quality (수질과 오염원의 장기적 변화를 통한 팔당호 상수원수질보전 특별대책지역 규제효과 분석)

  • Kim, Ho-Sub;Park, Yun-Hee;Kim, Yong-Sam;Kim, Sang-Yong
    • Journal of Korean Society on Water Environment
    • /
    • v.35 no.1
    • /
    • pp.43-54
    • /
    • 2019
  • The objective of this study was to assess the effect of policies on water quality management based on the changes in pollutants and water quality in Special Water Preservation Area (SWPA) of Lake Paldang watershed from 1990 to 2016. The population, total sewage and flow rate of wastewater in SWPA continuously increased from 1990 to 2016, while the location of new facilities for industrial and livestock facilities has been restricted. However, unlike the buffer zone in which industrial and livestock facilities were continuously reduced after implementing of TMDL, it was found that the effect of land-use regulations on industrial and livestock facilities in SWPA were mitigated by the increase in the size of large facilities. Since 1999 when the emission standard of public sewage treatment plants (STP) was changed, the water quality of Lake Paldang has increased despite the increase of pollutant source. Since emission standard of STP changed in 2012 (BOD 5 mg/L, TP 0.2 mg/L), BOD concentration in Lake Paldang has also improved to the level of water quality in the early 1990s where as TP concentration has remained at its lowest since 1990. BOD and TP average discharge concentration of 43 STP (${\geq}500m^3/day$) in 2016 have been maintained $1.7{\pm}0.7mg/L$ and $0.06{\pm}0.02mg/L$ respectively. While the discharged load of STP in SWPA was decreased by the concentration management, the contribution rate to the total discharged load of non-point pollutants increased to 70 % in 2015, and the contribution rate to the point discharged load of individual treatment facilities increased to 80 %.

A Study on the Service Area Planning of Elderly Care Facilities (노인요양시설 서비스 공간 계획에 관한 연구)

  • Choi, Jong-In;Lee, Nak-Woon
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.14 no.4
    • /
    • pp.11-20
    • /
    • 2008
  • The demand of the care facilities for the elderly will be increased, because of the social changes which desire well organized medical treatment service. However, they have been illogically administrating such as preparing service at living space because of lacking places which provide living service. So the side of administration, it is necessary to have a security and improvement in that kind of needed place. The studies of elderly care facilities have been placing too much emphasis on the living space of the residential facilities and their welfare facilities compare with the service providing place which is ignored just as a part of the living space. This study focus on a situation of elderly care facilities and analyze a service space using in facilities, so it can be applied to service place plan for the future.

  • PDF

Analysis of Water Quality Components and Antibiotics in the Final Effluent of Wastewater Treatment Facilities in the Nakdong River Basin (낙동강 유역에 위치한 폐수처리시설 최종방류수의 수질과 항생물질 분석)

  • Park, Kyeong-deok;Kang, Dong-hwan;Jo, Won Gi;Yu, Hun Sun;Yoon, Yeon Su;Kim, Byung-Woo
    • Journal of Environmental Science International
    • /
    • v.29 no.8
    • /
    • pp.857-870
    • /
    • 2020
  • In this study, the antibiotic components in the final effluent from the 12 wastewater treatment facilities located in the Nakdong River basin were investigated, and the correlation between organic matters, nutrients and antibiotics was analyzed. In the final effluent of the wastewater treatment facilities, three sulfonamides antibiotics (sulfamethazine, sulfathiazole, sulfachlorpyridazine) and tetracyclines antibiotics (oxytetracycline, doxycycline) were detected. Sulfamethazine were detected at all points and ranged from 10.398 to 278.784 ng/L. Sulfathiazole were detected at 6 points (Andong, Gumi, Hapcheon, Miryang, Uiryeong, Haman), and ranged from 23.773 to 144.468 ng/L. The correlation coefficients between sulfathiazole and TSS, COD, TOC, NH3-N, NO2-N, and T-N components were high in the range of 0.73 to 0.92. The correlation coefficient between sulfamethazine and T-N was 0.48, and the correlation with the rest of the water quality components was low. The correlation coefficient between sulfamethazine and sulfathiazole was 0.78. Through this study, it was confirmed that the concentration of sulfonamides antibiotics was higher than the concentration of tetracyclines antibiotics in the final effluent of 12 wastewater treatment facilities in the Nakdong River basin, and the concentration of sulfathiazole increased with organic matters and nutrients.

Identification of pollutant sources using water quality and stable isotope ratios of inflow tributaries in the lower reaches of the Han-River

  • Hong, Jung-Ki;Lee, Bo-Mi;Son, Ju Yeon;Park, Jin-Rak;Lee, Sung Hye;Kim, Kap-Soon;Yu, Soon-Ju;Noh, Hye-ran
    • Analytical Science and Technology
    • /
    • v.32 no.2
    • /
    • pp.65-76
    • /
    • 2019
  • Despite the expansion of sewage treatment facilities to reduce pollutants in the tributaries of the Han River, water pollution accidents such as fish deaths continue to frequently occur. The purpose of this study was to identify the pollutant sources using water quality and stable isotope ratio (${\delta}^{15}N$, ${\delta}^{13}C$, ${\delta}^{15}N-NH_4$, ${\delta}^{15}N-NO_3$) analysis results in the three inflow tributaries (Gulpocheon (GP), Anyangcheon (AY) and Sincheon (SC)) of the Han River. Water quality was analyzed in June and October from 2013 to 2017, and the results showed that the concentrations of nutrients, such as T-N, $NO_3-N$, and T-P, were increased at GP4, AY3, SC3, and SC4, which lie downstream of sewage treatment facilities. The results of ${\delta}^{15}N$ for June 2017 indicated that the source of nitrogen was sewage or livestock excreta at GP4 and SC4, and organic fertilizers at AY3 and SC3. ${\delta}^{15}N-NO_3$ results suggested that the source of nitrogen was related to organic sewage, livestock or manure at GP4, AY3 and SC4. Therefore, GP4 and SC4 were more influenced by effluent from sewage treatment facilities than by their tributaries, AY3 and SC3 were considered to be influenced more by their tributary than effluent from sewage treatment facilities. With the results of this study, the source of contamination (sewage treatment facility effluent) of river inflow downstream of Han River could be confirmed using water quality and stable isotope ratio.

Development of Benchmark Index of LoS for Asset Management of Water Treatment Facilities (정수시설 자산관리 LoS분석 벤치마크지수 개발)

  • Nam, Youngwook;Hyun, Inhwan;Lee, Chulsung;Chun, Mingyu;Kim, Mincheol;Kim, Dooil
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.29 no.6
    • /
    • pp.667-683
    • /
    • 2015
  • Since aged water treatment facilities could threaten the sustainable water supply, asset management system has been adopted for their systematic management. Level of Service(LoS) is one of critical components of asset management and could be quantified through benchmark index(BMI). Water supplier could estimate consumer's satisfaction and their performance through BMI to improve the LoS. We developed BMI for water treatment facilities from customer's satisfaction survey. BMI, represented with the Total Service Score(TSS), was assessed with water quality, water pressure, taste and odor, water rate, and service quality with weighing factors. BMI could, further, be used to assist the analysis of the life cycle cost to increase the unit of LoS.

A Study on the Types and Characteristics of Ancient Medical Facilities (고대 의료시설의 유형 및 특성에 관한 연구)

  • Lee, Haekyung;Chai, Choul Gyun
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.18 no.2
    • /
    • pp.77-84
    • /
    • 2012
  • This study is to understand the architectural types and characteristics of the medical facilities during ancient period. The study is based on the research of the medical and architectural history. The medical or healthcare facilities are influenced by their social, cultural and conceptual idea, especially how they think about 'disease', 'cure' and the 'medicine'. As the results of the examination of this study can be summarized as followings. Firstly, Ancient medical facilities are classified into four types according to the ideas of 'disease' and 'cure' ; 1) God oriented facility 2) health welfare facility 3) treatment oriented facility 4) practice & educational facility. Secondly, there are three typical types of the spatial characteristics what modern hospitals have ; 1) nursing ward 2) treatment ward 3) hostel or hospice. And they are all assembled around the courtyard in common. Thirdly, their architectures are not 'designed' but 'derived' plan by reasonable other building types, and transformed by medical function. Fourthly, a consideration of the surrounding circumstances is the most important point to make the medical health facilities during ancient period.

Substantial Improvement of Medical Care for Detainees in Republic of Korea (대한민국 수용자 의료처우의 실질적 개선)

  • Samin Hong
    • Health Policy and Management
    • /
    • v.33 no.3
    • /
    • pp.370-375
    • /
    • 2023
  • The responsibility to ensure the health rights of detainees, particularly their medical rights, fundamentally lies with the state in all nations. However, in the correctional facilities of the Republic of Korea, these rights are currently not adequately safeguarded. Numerous detainees express dissatisfaction with the medical services provided and show a preference for voluntary external treatment. However, barriers such as prolonged application processes for external treatment and the requirement for detainees to cover their medical expenses present significant challenges. Therefore, the National Human Rights Commission of Korea has advocated for an increased medical budget in correctional facilities and a bolstered professional medical workforce to improve the medical care of detainees. Recommendations for improvements include: (1) establishing dedicated correctional hospitals for detainees, (2) setting up specialized correctional wards, (3) collaborating with military hospitals, (4) launching mobile medical buses for diverse specialties, (5) enhancing collaboration with public and private medical institutions, (6) increasing compensation for partnering external medical institutions, (7) improving the working conditions of medical officers, (8) safeguarding the defense rights of medical staff, (9) improving the working conditions of public health doctors from the Ministry of Justice in correctional facilities, and (10) pre-assigning public health specialists and military doctors to correctional facilities. By implementing these measures, it is anticipated that the quality of medical services in the Republic of Korea's correctional facilities will improve, reducing the demand for external treatments among detainees and ensuring their health and medical rights are realistically upheld.

An Overview of Coal Mine Drainage Treatment (석탄광의 광산배수처리기술 현황 및 전망)

  • 정영욱
    • Economic and Environmental Geology
    • /
    • v.37 no.1
    • /
    • pp.107-111
    • /
    • 2004
  • This study was undertaken to summarize of the efficiencies of the passive treatment system and suggest future studies for the solution of mine drainage problem. Flow rates of mine drainage from the abandoned coal mines are about 80,000 ton/day. Contaminated mine drainages over about 50 ton/day of flow rate were treated by passive treatment facilities such as Successive Alkalinity Producing Systems(SAPS), oxidation pond and oxic wetland. Chemical analysis for 13 passive coal mine treatment facilities showed that SAPS was the core of treatment facilities because the variation of Fe removal rates was relatively smaller than any other processes and re-leaching of Fe was not measured. The performance and life of SAPS depended on decrease in permeability and retention time due to accumulation of sludge. It is inferred that upgrade of design of the passive treatment system and in-situ treatment using underground void will be necessary for the amelioration of the mine drainage with high metal loading rates.