• Title/Summary/Keyword: treatment facilities

Search Result 1,275, Processing Time 0.028 seconds

Ecotoxicity Assessment of Industrial Effluent in Gyeonggi-do (경기지역 산업시설 방류수 생태독성 영향 평가)

  • Cho, Won-Sil;Kim, Sang-Hoon;Yang, Hyoung-Jae
    • Journal of Environmental Health Sciences
    • /
    • v.37 no.2
    • /
    • pp.113-123
    • /
    • 2011
  • Objectives: Industrial development in Korea results in a rapid increase in the number of chemicals, some of which may be responsible for toxicity to aquatic ecosystems. In addition, the types of hazardous chemicals included in industrial effluents have gradually increased. Therefore, chemical analysis alone is not enough to assess ecological effects of toxic chemicals in wastewater. Methods: In response to new regulations as whole effluent toxicity (WET) tests for effluent discharge of 15 publicly owned treatment works (POTWs) and 25 industrial effluent treatment plants in Gyeonggi-do, which will be effective from 2011, a necessity of studies emerges that investigates toxicity levels. Results: In case of the public treatment plants, none of them had exceeded the criteria for ecotoxicity. As for individual wastewater discharge facilities, on the other hand, two types were found to exceed the criteria: pulp and paper manufacturing facilities and pharmaceutical manufacturing facilities. For the pulp and paper manufacturing facilities, monitoring results could not help determine the exact toxicant identification. However, Daphnia magna inhibition effect or death was found to leave white plums, suggesting that suspended solids treated and the polymer used in coagulant dose. In case of pharmaceutical manufacturing facilities, the general water quality parameters cannot affect Daphia magna. However, conductivity and salinity can have an effect to be 14,000 ${\mu}s/cm$, 8.1‰ by salts, respectively. Toxicity Identification Evaluation (TIE) and Toxicity Reduction Evaluation (TRE) procedures results appeared to be effective for identifying toxic compounds in $Cl^{-}$ and $SO_4^{2-}$. Conclusions: It is necessary to develop control measures for water treatment chemicals and salts used for processes such as coagulation in individual wastewater discharge facilities in order to achieve the goal to protect aquatic ecosystems in public waters.

Real-time measurement management system UI development linked the Water treatment facilities Broadband Convergence Network (수처리시설용 광대역 통합망 연계형 실시간 계측 관리 시스템 UI개발)

  • Yang, Seungyoun;Kim, Jintae;Oh, Hwanjin;Lee, Minwoo
    • Journal of Satellite, Information and Communications
    • /
    • v.10 no.4
    • /
    • pp.83-86
    • /
    • 2015
  • In this paper, we propose a real-tim measurement management system UI development linked the Water treatment facilities broadband Convergence Network. The sensor and the image data received by the server develop a program to interact with Web through water treatment facilities broadband convergence network. So, Separately develop UI capable of independently operating. Building a web server for remote monitoring of the transmission sensor and the image data. And Monitoring and control is possible the sensor data and image data through the Web-based UI. We can grasp the current state such as measurement time, concentration and depth of interface through the proposed real-time measurement management system UI development liked the water treatment facilities broadband convergence network. So, we can check in whether the normal operation of water treatment facilities and whether the casualties such as fire and security. As well as real time to see the information at a glance due to UI development can be raal-time monitoring of real-time measurement management system.

A Study on the Odor Removal Control System of Sewage Sludge

  • KIM, Su-Hye;LEE, So-Hee;YUN, Yeo-Jin;CHOI, Soo-Young;JUNG, Min-Jae;KWON, Woo-Taeg
    • Journal of Wellbeing Management and Applied Psychology
    • /
    • v.4 no.2
    • /
    • pp.19-25
    • /
    • 2021
  • Purpose: The purpose of this study is to reduce odor complaints by identifying problems with odor management at the site of the water regeneration center and researching odor management methods. Due to the high population density of Korea, sewage treatment facilities are adjacent to residential and industrial areas. According to previous studies, the main malodor-emitting facilities of sewage treatment facilities were preliminary treatment facilities (2,220 times), sedimentation basins (4,628 times), and sludge treatment facilities (9,616 times). Research design, data and methodology: Compound malodors and designated malodor-producing substances were collected from five site boundaries of the water regeneration center and analyzed according to the official methods to test malodor, and a total of two times (August and September 2020) were conducted. Results: As a result of the measurement, in the green area in front of the center office, compound malodors were detected at a maximum of 8 times and at least 3 times during the dawn time. As for the designated malodor-producing substances, 0.1ppm of ammonia was detected in the green area in front of the center office and the park golf course. This is within 15 times the maximum allowable emission level of compound malodors and within 1ppm of the maximum allowable emission level of ammonia. Conclusions: Even if the dilution rate of the compound malodors did not exceed the maximum allowable emission level, the odor could be recognized, and more research is needed in the future to establish effective reduction measures according to the subjective and individual and seasonal odor characteristics.

A Study on Odor Emission Characteristics of Domestic Sewage Treatment Facilities Using Composite Odor Concentration and Hydrogen Sulfide Concentration (복합악취 농도와 황화수소 농도를 이용한 국내 하수처리시설의 악취발생 특성에 대한 연구)

  • Ko, Byung-Churl;Lee, Jong-Kuk;Lee, Yoon-Su;Lee, Min-Gyu;Kam, Sang-Kyu
    • Journal of Environmental Science International
    • /
    • v.21 no.11
    • /
    • pp.1379-1388
    • /
    • 2012
  • Odor from sewage treatment plants have the potential to cause significant annoyance and to impact the amenity. In this study, odor emission characteristics at unit process of 48 sewage treatment facilities in 39 plants were evaluated using composite odor concentration and hydrogen sulfide ($H_2S$) concentration. The values of composite odor concentration (geometry mean) and $H_2S$ concentration (median) for sludge treatment processes are higher than those for the other treatment processes. The composite odor concentration and $H_2S$ concentration are distributed over a wide area in each process. Composite odor concentration (dilution ratio) was found to have the significant correlation with $H_2S$ concentration (p=0.000<0.05). The $H_2S$ concentration accounted for 67.1% of composite odor concentration.

Citizen's Attitude to Environmental Facilities (환경기초시설에 대한 시민 의식 조사)

  • Chung, Jae-Chun;Chung, Won-Tae;Tak, Seung-Je;Kang, Hun
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.3 no.2
    • /
    • pp.97-102
    • /
    • 1995
  • A questionare survey was performed to investigate the citizen's attitude concerning waste treatment facilities. Most people recognized the seriousness of the waste treatment problem and think that more composting facilities should be built. People dislike most the landfill facility, followed by the nightsoil treatment facility, the incineration facility and the composting facility. Most people answered that the disirable distance from their house to the treatment facility should be farther than 4km for the landfill facility, farther than 2km for incineration and composting facilities and farther than 1km for the wastewater treatment plant. Most people want moving cost+land price+inconvience suffering cost (amount equal to the land prize+building prize) for their retrieval. About 30% of people answered that they will not accept any waste treatment facility even though it is perfect.

  • PDF

The Case Study on Performance Measurement Weighting for Efficient Value Engineering Study of Sewage Treatment Facliity (하수처리시설의 효율적인 VE수행을 위한 다단계성능평가 분석)

  • Kim, Dongjin;Park, Jaeil;Lee, Jaehun;Lee, Minjae
    • Korean Journal of Construction Engineering and Management
    • /
    • v.17 no.1
    • /
    • pp.40-47
    • /
    • 2016
  • Recently, the demand of sewage treatment facilities have increased by growing the population growth of city and industrialization. However, most of public sewage treatment facilities lack the preparations of design criteria by increasing sewage water amount in the future. In order to respond to this situation, the government has consistently promoted the sewage treatment construction project. This study conducted a survey targeting residents and sewage treatment facilities, civil engineering a VE project professionals for effectively operating the sewage treatment facilities and improving its value to be built in the future. Based on this survey, this study will introduce the list of performance measurements which can not only save cost but also reflect opinion of users and residents. In addition, using Multi-Level Performance Measurement and AHP analyzed the weights of performance measurement which is more objective than existing things for applying efficient VE process

Improvement for Asset Management of Sewage Treatment Facilities (하수처리시설 대수선비 자산화 영향분석 및 제도개선 방안)

  • Park, Ha Jin;An, Man Sun;Cho, Nam Ho;Kim, Kyong Ju
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.2D
    • /
    • pp.285-293
    • /
    • 2011
  • Sewage treatment facilities are growing rapidly in quantitatively and qualitatively. However, privatization such as up-size and professionalism, etc. are insufficient, compared to global companies' cases. Infrastructure Asset management has not been applied widely despite of sewage treatment facilities are one of the most critical social infrastructure. Maintenance, repair, and rehabilitation (R&R) practices of sewage treatment facilities have been studied and infrastructures asset management techniques have been applied. Cost model which makes it possible to calculate managerial costs such as major cost, etc. needs to be developed only with project basic information when proceeding new sewage treatment facility construction and management and overseas sewage project. Effects to converse major repair cost into capital, application of sewage treatment facility's asset management, expected effects, etc. were analyzed and suggested an alternative on the improvements of legal system.

A SURVEY OF THE TREATMENT IN FREE MOBILE DENTAL CLINIC AT THE DISABLED RESIDENTIAL FACILITES (SURVEY OF FREE MOBILE DENTAL CLINIC: AT DISABLED RESIDENTIAL FACILITES) (장애인 거주시설을 방문하여 시행한 무료 이동식 치과 진료에 대한 2014년 통계 (시설거주장애인을 대상으로 한 이동치과진료에 대한 통계))

  • Lim, Hyun soo;Lee, Hyo-Seol;Choi, Sung Chul;Lee, Eun young;Kim, Kwang Chul
    • The Journal of Korea Assosiation for Disability and Oral Health
    • /
    • v.11 no.2
    • /
    • pp.58-61
    • /
    • 2015
  • The people with disabilities living in residential facilities have more difficulty in caring oral hygiene than those living at home. The purpose of this study is to evaluate the recent 2014 dental treatment records of free mobile dental clinic service for disabled people in Korea. 203 disabled living in residential facilities participated in mobile dental clinic. Patients classified according to types of disability. Mental retardation were 75.3%, mental disorder were 6.0%, crippled disorder were 7.4%, brain disorder were 6.5%, visual disorder were1.4%, auditory and speech disorder were 2.3% and autism disorder were 0.9%. Performed treatments were 99 scaling and curettage, 88 fluoride varnish and TBI, 4 extraction, 1 endodontic treatment, 16 caries control (resin filling, GI filling), 1 denture repair and 8 refuse the treatment. Free mobile dental clinic can not provide complex dental treatment. So, the organization should systemize advanced dental treatment and regular preventive programs. Furthermore, we need to have a more concerns about the people with disabilities living in residential facilities and constantly participate on a dental voluntary work.

Physicochemical Characteristics and Estimation of H2S Emission Rate from Municipal Solid Waste at the Environmental Facilities in Busan City (부산지역 환경기초시설에서 발생하는 폐기물의 물리, 화학적 특성 규명 및 황화수소 발생량 예측에 관한 연구)

  • Lee, Taeyoon;Kim, Doyong;Kim, Jaejin;Lee, Junki
    • Journal of the Korean GEO-environmental Society
    • /
    • v.10 no.2
    • /
    • pp.13-20
    • /
    • 2009
  • There have been increasing interests in the odor generation problems as concerns about the quality of life has been increased recently. Especially, approximately 67% of the odor complaints from environmental facilities are those from sewage treatment facilities and food waste treatment facilities. Moreover, sewage ocean dumping will be prohibited from 2012 by the international and domestic ocean laws, and thus, demand for alternative management plans is increasing. Therefore, it was first selected 5 sewage treatment facilities and 5 food waste treatment facilities where the amounts of waste are relatively immense in Busan, and collect their sludge samples. Then it was investigated the samples' physical and chemical characteristics through proximate analysis, elemental analysis, XRF analysis, and calorific value analysis. Finally, estimate the $H_2S$ emission rates were estimated in order to apply the results as the basic data for providing the fundamental solution for the oder complaints. As a result, the concentration of $H_2S$ in sewage sludge and in food waste treatment facility were 57.3 mg/kg and 19.7 mg/kg in average, respectively. Finally, the units of $H_2S$ in wastes stored in total 10 waste treatment facilities was estimated 16,017,910.0 mg/d.

  • PDF

Determination of Optimal Livestock Wastewater Treatment Process for Linked Treatment in Sewage Treatment Plant (하수처리장 연계처리를 위한 가축분뇨 최적 처리공정 선정에 관한 연구)

  • Kim, Choong Gon;Shin, Hyun Gon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.20 no.3
    • /
    • pp.52-59
    • /
    • 2012
  • As the result of reviewing the linked treatment of water quality for treating process at public livestock wastewater treatment facilities for fair selection of the proper linked process in case of linking sewage treatment plant for livestock wastewater, in case of wastewater processed by bio-reactor that is only biologically-treated, the load factor showed relatively high as 1.67%(base on design quality), 2.59%(base on operation quality) regarding COD and 3.69%(base on design quality), 7.67%(base on operation quality) regarding $COD_{Mn}$ but it is judged that there is nearly no influence on the operation of sewage treatment plan. And, in case of oxidized flotation-treated water & biofiltlation-treated water that are the advanced wastewater treatment, the load factor is approximately 1% and there is concern about the installation of excessive facilities in case of installing the advanced wastewater treatment. So, in case of considering the economic efficiency & stable operation of sewage treatment plant S, it is judged to be desirable to link with wastewater processed by bio-reactor that is biologically-treated.