A Commissioning of 3D RTP System for Photon Beams

  • Kang, Wee-Saing
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.119-120
    • /
    • 2002
  • The aim is to urge the need of elaborate commissioning of 3D RTP system from the firsthand experience. A 3D RTP system requires so much data such as beam data and patient data. Most data of radiation beam are directly transferred from a 3D dose scanning system, and some other data are input by editing. In the process inputting parameters and/or data, no error should occur. For RTP system using algorithm-bas ed-on beam-modeling, careless beam-data processing could also cause the treatment error. Beam data of 3 different qualities of photon from two linear accelerators, patient data and calculated results were commissioned. For PDD, the doses by Clarkson, convolution, superposition and fast superposition methods at 10 cm for 10${\times}$10 cm field, 100 cm SSD were compared with the measured. An error in the SCD for one quality was input by the service engineer. Whole SCD defined by a physicist is SAD plus d$\sub$max/, the value was just SAD. That resulted in increase of MU by 100${\times}$((1_d$\sub$max//SAD)$^2$-1)%. For 10${\times}$10 cm open field, 1 m SSD and at 10 cm depth in uniform medium of relative electron density (RED) 1, PDDs for 4 algorithms of dose calculation, Clarkson, convolution, superposition and fast-superposition, were compared with the measured. The calculated PDD were similar to the measured. For 10${\times}$10 cm open field, 1 m SSD and at 10 cm depth with 5 cm thick inhomogeneity of RED 0.2 under 2 cm thick RED 1 medium, PDDs for 4 algorithms were compared. PDDs ranged from 72.2% to 77.0% for 4 MV X-ray and from 90.9% to 95.6% for 6 MV X-ray. PDDs were of maximum for convolution and of minimum for superposition. For 15${\times}$15 cm symmetric wedged field, wedge factor was not constant for calculation mode, even though same geometry. The reason is that their wedge factor is considering beam hardness and ray path. Their definition requires their users to change the concept of wedge factor. RTP user should elaborately review beam data and calculation algorithm in commissioning.

  • PDF

10 MV 이상 고에너지 치료 시 발생되는 광중성자의 영향 (The Effect of Photoneutron Dose in High Energy Radiotherapy)

  • 박병석;안종호;권동열;서정민;송기원
    • 대한방사선치료학회지
    • /
    • 제25권1호
    • /
    • pp.9-14
    • /
    • 2013
  • 목 적: 10 MV 이상 고에너지 방사선 치료 시 광핵반응을 통해 광중성자가 발생된다. 광중성자는 방사선하중계수가 X선 보다 커 작은 선량에도 인체에 미치는 영향이 크므로 정확한 선량계산 및 고려가 필요하다. 이에 광자선 에너지 크기와 치료방법에 따른 광중성자의 선량변화를 공간적인 측면에서 비교 분석하였다. 대상 및 방법: 광자선의 에너지 크기에 따른 광중성자의 선량 변화를 측정하고자 동일한 치료부위의 환자를 대상으로 치료 계획을 10 MV와 15 MV conventional plan으로 각각 만들었다. 그리고 치료방법에 따른 차이에 대해 측정하고자 10 MV conventional plan과 10 MV IMRT plan을 각각 만들었다. 검출기의 위치는 광자선원으로부터 isocenter까지의 거리를 100 cm으로 정한 기준점을 $^3He$비례계수기의 중심점에 위치시키고 광중성자 선량을 측정하였다. 또한 중심점을 기준으로 couch의 longitudinal 방향으로 상방, 하방 50 cm 방향으로 각각 $^3He$비례계수기를 위치시켜 위치변화에 따른 선량변화를 측정하여 상용프로그램을 이용하여 분석하였다. 결 과: 에너지 크기에 따른 광중성자의 평균 누적선량은 10 MV, 15 MV conventional RT시 각각 $220.27{\mu}Sv$, $526.61{\mu}Sv$로 15 MV conventional RT가 평균 2.39배의 선량이 증가하였다. 동일한 에너지의 conventional RT와 IMRT의 광중성자의 평균 누적선량은 Conventional RT, IMRT 시 각각 $220.27{\mu}Sv$, $308.27{\mu}Sv$로 IMRT가 1.40배의 선량이 증가하였다. 측정위치에 따른 광중성자의 누적선량은 Conventional RT시 point 2가 3보다 10 MV에서는 약 7.1%, 15 MV에서는 3.0%로 유의하게 높게 측정되었다. 결 론: 고에너지 방사선 치료 시 광중성자에 의한 불필요한 선량을 줄이기 위해 에너지의 선택, 치료 방법의 결정 및 환자의 position을 고려해야 할 것이다. 또한 광중성자의 선량 데이터를 체계화하여 전산화계획 프로그램에 적용되는 방안을 모색하여야 할 것이다. 이는 환자에게 불필요한 선량을 최소화하고 방사선 치료로 인한 2차 암 발생확률과 부작용을 감소시킬 수 있을 것으로 사료된다.

  • PDF

세기조절방사선치료 시 치료 부위에 따른 치료계획 시스템 간 선량평가 (Dose Evaluation of TPS according to Treatment Sites in IMRT)

  • 김진만;김종식;홍채선;박주영;박수연;주상규
    • 대한방사선치료학회지
    • /
    • 제25권2호
    • /
    • pp.181-186
    • /
    • 2013
  • 목 적: 본 연구는 치료계획 시스템인 $Pinnacle^3$ (version 9.2, Philips Medical Systems, USA)과 Eclipse (version 10.0, Varian Medical Systems, USA)을 이용하여 전립선암과 폐암의 세기조절방사선 치료계획시 불균질 부위의 선량 계산 차이를 알고리즘별로 알아보고자 한다. 대상 및 방법: 각 5명의 전립선암 및 폐암 환자를 대상으로, 본원 Protocol에 따른 동일한 조건으로 최적화 계산을 진행하였다. 전립선암 환자의 치료계획은 10 MV, 7Beam을 사용하였으며 2.5 Gy씩 28 fx, 총 70 Gy를 동일 처방하였고, 폐암 환자의 치료계획은 6 MV, 6Beam을 사용하였으며 2 Gy씩 33 fx, 총 66 Gy를 동일 처방하였다. 두 치료계획시스템을 통해 CTV, PTV 및 종양주위의 OAR의 최대선량, 평균선량, 최소선량을 비교하였다. 결 과: 전립선암에서 두 치료계획시스템 모두 CTV와 PTV의 선량변화가 2%이내였으며 종양주변 정상 장기(방광, 대퇴골, 직장)도 선량제약조건을 충족하였다. 폐암에서도 CTV와 PTV는 2%이내의 선량변화를 보였고, 정상 장기(식도, 척수, 양측 폐)도 선량제약 조건을 충족하였다. 하지만, Eclipse 치료계획의 최소선량은 CTV에서 1.9%, PTV에서 3.5% 높았고 양측 폐의 경우 V5 Gy에서 3.0% 높은 차이를 보였다. 결 론: 치료부위에 따른 각각의 치료계획시스템은 본원의 선량제한 조건을 모두 만족하여 임상적 정확성을 확인할 수 있었다. 향후 다양한 부위의 치료계획 연구와 치료계획시스템의 적용은 보다 정확한 치료계획을 위한 방법을 제시할 것이라 사료된다.

  • PDF

HalcyonTM 선형가속기 6MV-FFF 에너지의 표재 선량에 대한 고찰: Phantom Study (A Study on Superficial Dose of 6MV-FFF in HalcyonTM LINAC: Phantom Study)

  • 최성훈;엄기천;유순미;박제완;송흥권;윤인하
    • 대한방사선치료학회지
    • /
    • 제32권
    • /
    • pp.31-39
    • /
    • 2020
  • 목 적: 본 연구는 HalcyonTM과 TrueBeamTM에서 사용하는 6MV-FFF(Flattening Filter Free) 에너지를 이용하여 전산화치료계획시스템(Treatment Planning System, TPS)에서 계산된 선량과 광자극형광선량계(Optically Stimulated Luminescence Dosimeter, OSLD)로 측정된 표재 선량(Superficial dose)을 비교하고자 한다. 재료 및 방법: 팬텀연구를 위해 인체모형 팬텀(Human Phantom)의 CT 영상을 이용하여 치료계획시스템에서 성문암(Glottic cancer)과 유사한 치료계획용적(Planning Target Volume, PTV)과 두경부위의 등 중심점(Iso-center) 위치에 측정을 위한 Point(M), Point(R), Point(L)의 구조물을 설정하고 체표윤곽(Body contour)에 5mm Bolus를 적용하였다. 그 후 전산화치료계획은 HalcyonTM과 TrueBeamTM의 6MV-FFF 에너지를 이용하여 정적(Static) 세기변조방사선치료(Intensity Modulated Radiation Therapy, IMRT)와 용적변조회전치료(Volumetric Modulated Arc Therapy, VMAT)계획을 각각 수립하였다. 전산화치료계획과 동일하게 재현하기 위해 OSLD를 등 중심점에 위치시키고 5mm Bolus를 적용하여 선량 전달 후 오차율을 비교하였다. 결 과: 인체모형 팬텀을 사용한 실험 결과 HalcyonTM의 전산화치료계획시스템에서의 점 선량과 OSLD를 이용한 선량 측정의 오차율의 절댓값의 평균은 VMAT, IMRT 각각 1.7±1.2%, 4.0±2.8%로 확인되었으며, TrueBeamTM의 오차율의 절댓값의 평균은 VMAT, IMRT 각각 2.4±0.4%, 8.6±1.8%로 확인되었다. 결 론: 실험결과 HalcyonTM을 기준으로 TrueBeamTM에서 VMAT과 IMRT 각각 2.4배, 3.6배 더 큰 오차가 발생하는 것을 확인할 수 있었다. 따라서 본 연구의 결과를 토대로 표재 선량에 대한 정확한 선량평가가 이루어져야 하는 경우, TrueBeamTM보다 HalcyonTM에서 정확한 선량 평가가 이루어질 수 있을 것으로 사료된다.

Verification of Extended Source-To-Imager Distance (SID) Correction for Portal Dosimetry

  • Son, Jaeman;Kim, Jung-in;Park, Jong Min;Choi, Chang Heon
    • 한국의학물리학회지:의학물리
    • /
    • 제29권4호
    • /
    • pp.137-142
    • /
    • 2018
  • This study aimed to evaluate and verify a process for correcting the extended source-to-imager distance (SID) in portal dosimetry (PD). In this study, eight treatment plans (four volumetric modulated arc therapy and four intensity-modulated radiation therapy plans) at different treatment sites and beam energies were selected for measurement. A Varian PD system with portal dose image prediction (PDIP) was used for the measurement and verification. To verify the integrity of the plan, independent measurements were performed with the MapCHECK device. The predicted and measured fluence were evaluated using the gamma passing rate. The output ratio was defined as the ratio of the absolute dose of the reference SID (100 cm) to that of each SID (120 cm or 140 cm). The measured fluence for each SID was absolutely and relatively compared. The average SID output ratios were 0.687 and 0.518 for 120 SID and 140 SID, respectively; the ratio showed less than 1% agreement with the calculation obtained by using the inverse square law. The resolution of the acquired EPIDs were 0.336, 0.280, and 0.240 for 100, 120, and 140 SID, respectively. The gamma passing rates with PD and MapCHECK exceeded 98% for all treatment plans and SIDs. When autoalignment was performed in PD, the X-offset showed no change, and the Y-offset decreased with increasing SID. The PD-generated PDIP can be used for extended SID without additional correction.

치료 계획용 전산화 단층촬영이 방사선 치료계획에 미치는 효과 (The Effect of Therapy Oriented CT in Radiation Therapy Planning)

  • 김성규;신세원;김명세
    • Radiation Oncology Journal
    • /
    • 제5권2호
    • /
    • pp.149-155
    • /
    • 1987
  • 전산화 단층촬영 (CT)은 진단 분야 뿐 아니라 방사선 치료 계획 및 치료효과의 추적 등 치료분야에 까지 광범위하게 사용되고 있다. 그러나 환자의 체위가 치료시와는 다름으로 얻어진 영상이 치료시의 영상과는 차이가 있으며, 삼차원적인 치료면적의 계산이 곤란할 뿐 아니라 조영제를 사용함으로 생길 수 있는 선량계산의 오라 및 정확한 조사야가 표현되지 많음으로 병소 및 중요 정상장기의 선량 측정이 정확하지 못한점 등의 단점이 없다. 저자들은 1986년 5월 1일부터 1987린 4월 30일까지 영남대학병원 치료방사선과에서 치료받은 총 365명의 환자 중 일반 CT의 단점을 보완한 치료용 CT와 종래의 simulation을 병행한 106명의 치료계획을 비교 분석하여 다음과 같은 결과를 얻었다. 치료용 CT후 두경부 암 환자의 $47\%$, 흉부암 환자의 $79\%$, 복부암 환자의 $63\%$에서 치료계획의 변경이 있어 치료용 CT가 두경부암, 흉부암, 복부암에서 거의 철수적임을 시사하였다. 그러나 직장암, 자궁경부암에서는 추가치료의 조사야의 측정 및 선량계산 이외의 전예에서 치료계획의 변경이 없었다. 선량분포의 비교측정에서는 윤곽만을 사용한 종래의 선량계산이 CT를 사용한 경우에 비해서 두경부암에서는 평균 $20\%$, 흉부암, 복부암에서는 약 $10\%$의 차이를 보여 전례에서 CT보다 과측정 되었음을 보여 종래의 윤곽만을 사용한 치료계획시의 저선량 조사에 대한 보정이 필요함을 시사하였다.

  • PDF

방사선치료 시 자세확인시스템이 처방선량에 미치는 영향 (The Effect of Patients Positioning System on the Prescription Dose in Radiation Therapy)

  • 김정호;배석환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제40권4호
    • /
    • pp.613-620
    • /
    • 2017
  • 방사선치료 시 치료계획 선량의 정확한 전달이 중요하다. 뿐만 아니라 정확한 자세 잡이도 필요하다. 하지만 정확한 자세 잡이를 위해서는 자세촬영을 실시하여야 하며 이에 따른 추가적인 방사선 피폭이 발생하게 된다. 이에 자세촬영 주기에 따른 선량분포의 변화를 분석하고자 한다. 팬텀 내 45개 지점에 대해 OSLD를 이용하여 6MV와 10MV 광자선, 그리고 온보드이미지촬영과 콘빔전산화단층촬영에 대한 선량을 측정하였다. 그리고 각 지점에 대한 자세확인촬영이 치료선량에 합산될 경우의 차이값을 비교하였다. 또한 차이값이 미국의학물리협회에서 권고하는 5%를 만족하는 촬영 주기를 제시하고자 하였다. 그 결과 6MV에서는 최소 45.27 cGy에서 최대 98.6 cGy, 10MV에서는 최소 53.34 cGy에서 최대 99.66 cGy, 온보드이미지촬영의 경우 최소 0.19 cGy에서 최대 2.64 cGy, 콘빔전산화단층촬영의 경우 최소 0.54 cGy에서 최대 17.18 cGy가 측정되었다. 치료선량에 대한 자세확인촬영 방사선량의 비율은 2차원 영상의 경우 치료 1회당 최대 3.49%, 3차원 영상의 경우 치료 1회당 최대 22.65%의 오차가 발생된다. 따라서 2차원 영상은 1일 1회, 3차원 영상은 1주 1회까지 허용된다. 향후 추가연구 시 실제 임상적용 시에는 환자자세촬영 종류의 병행에 대한 분리계산이 필요하리라 사료된다.

미소선원 적분법과 몬테칼로 방법을 이용한 AAPM TG-43 선량계산 인자 평가: microSelectron HDR Ir-192 선원에 대한 적용 (Evaluation of Factors Used in AAPM TG-43 Formalism Using Segmented Sources Integration Method and Monte Carlo Simulation: Implementation of microSelectron HDR Ir-192 Source)

  • 안우상;장원우;박성호;정상훈;조운갑;김영석;안승도
    • 한국의학물리학회지:의학물리
    • /
    • 제22권4호
    • /
    • pp.190-197
    • /
    • 2011
  • 고선량률 근접치료에 사용되는 상업용 선원과 치료계획 시스템들은 AAPM TG 43에서 권고하는 점 및 선 선원에 의해 선량분포를 계산한다. 하지만, 근접치료용 선원에 대한 인체 내의 정확한 선량계산을 위해서 3차원 부피의 선원을 고려하는 MC 기반의 선량계산 방법이 필요하다. 본 연구에서는 microSelectron HDR Ir-192 선원을 작은 부분으로 분할하여 계산하는 미소선원 적분법을 이용하여 기하학적 인수를 계산하였다. 또한, 범용 방사선 수송코드인 MCNPX를 사용하여 30 cm 직경의 구형 물 팬텀 내에서 선원의 선량률을 계산하여 비등방성함수와 반경선량함수를 구하였다. 그 결과를 MC 기반 광자 수송코드인 MCPT를 사용하여 계산한 Williamson의 결과와 비교 및 분석하였다. 미소선원 적분법과 선 선원 근사법에 따른 기하학적 인수는 $r{\geq}0.5cm$에서는 0.2% 이내에서 일치하였고 r=0.1 cm일 때 1.33%의 차이를 보였다. 본 연구에서 계산된 비등방성함수와 반경선량함수가 Williamson의 계산된 결과의 차이는 비등방성함수의 경우 r=0.25 cm에 서 2.33%의 가장 큰 R-RMSE를 보였고 $r{\geq}0.5cm$에서는 1% 미만의 R-RMSE를 보였다. 반경선량함수의 경우는 r=0.1~14.0 cm에서 0.46%의 R-RMSE를 보였다. 미소선원 적분법과 선 선원 근사법으로 계산한 기하학적 인수는 $r{\geq}0.1cm$에서 잘 일치하지만 3차원의 Ir-192 선원을 적용하여 계산한 미소선원 적분법이 실제 기하학적 인수를 잘 반영할 것으로 생각된다. r=0.25 cm에서 비등방성함수를 제외하고는 MCPT와 MCNPX의 몬테칼로 코드를 이용하여 얻어진 비등방성함수와 반경선량함수는 각각의 몬테칼로 코드에 대한 불확실성 이내에서 잘 일치함을 확인하였다. 따라서 MCNPX 전산모사 결과를 통해 TG-43의 선량 계산식에 사용된 인자를 Williamson 등의 결과와 비교 및 검증함으로써, 추후 다른 종류의 선원에 대해서도 Monte Carlo 기반의 연구가 가능할 것으로 기대된다.

자궁강내 근접방사선조사시 인체조직등가 팬톰을 이용한 방사선량 측정 (Measurement of Radiation Using Tissue Equivalent Phantom in ICR Treatment)

  • 장홍석;서태석;윤세철;유미령;박용휘;신경섭
    • Journal of Radiation Protection and Research
    • /
    • 제20권1호
    • /
    • pp.45-52
    • /
    • 1995
  • 자궁경부암환자에서 자궁강내 근접 방사선조사시 선원 배열에 따른 선량분포와 임상적으로 중요한 표식점인 A 및 B점 선량값에 대한 정확성을 평가하기 위하여 조직등가 팬톰을 제작하고 필름선량계측법을 적용하여 측정한 후, 이를 along-away에 의한 계산과 전산화치료계획장치에 의한 값과 비교 분석하였다. 대상 및 방법 : 자궁강내 근접 방사선조사시 치료상태를 그대로 묘사할 수 있게 아크릴과 물을 이용하여, 인체조직등가 팬톰을 제작한 후 자궁경부암의 자궁강내 근접 방사선조사를 시행하는 것과 똑같이 Fletcher-Suit-Delclos applicator 를 삽입하였다. Tandem 에 $15.7mg\;Ra-eq$의 방사능을 가진 $^{137}Cs$ tube를 2cm 간격으로 3개 주입한 후, A점에 해당되는 단면에 수직방향과 평행방향으로 각각 필름을 팬톰 간극에 삽입하였고, 또한 팬톰표면의 방사선량분포측정을 위하여 팬톰표면을 필름으로 감싸서, 1시간 조사하였다. 필름에 현상된 음영을 필름농도계를 이용하여 농도분포를 측정하여, A점에 대한 방사선량을 환산하였고, 전체적인 선량분포도를 얻었다. 이러한 측정값과 전산화치료계획장치를 이용하여 얻은 A점 값, along-away 표에 의한 A점 선량을 비교하였고, 필름에 의한 선량분포와 컴퓨터에 의한 선량분포를 서로 비교하였다. 결과 : A점에 대한 필름 측정치는 시간당 51.2cGy였고, 전산화치료계획장치에 의한 계산값은 시간당 46.7cGy, along-away 표에 의한 값은 시간당 47.9 cGy여서 약 10% 이내로 비교적 일치하였다. 필름을 계측하여 얻은 선량분포와 전산화치료계획장치의 계산에 의한 선량분포는 비슷한 모습을 보여 주었다. 결른 : 본 연구에서 아크릴과 물을 이용하여, 간단하고 경제적인 방법으로 인체조직등가팬톰을 제작할 수 있었고, 이러한 간단한 팬톰을 이용하여 비교적 효과적으로 자궁강내 근접 방사선조사시 사용하는 밀봉선원인 $^{137}Cs$ tube 의 선량에 대한 품질검사는 물론, 전산화치료계획장치를 이용한 값과 이론적인 식을 바탕으로 수작업으로 계산한 값, 그리고 실험으로부터 구한 실측값을 비교 검토함으로써 치료계획의 신뢰성을 확인할 수 있었다.

  • PDF

Survey of Radiation Shielding Design Goals and Workload Based on Radiation Safety Report: Tomotherapy Vault

  • Cho, Kwang Hwan;Jung, Jae Hong;Min, Chul Kee;Bae, Sun Hyun;Moon, Seong Kwon;Kim, Eun Seog;Cho, Sam Ju;Lee, Rena
    • 한국의학물리학회지:의학물리
    • /
    • 제29권1호
    • /
    • pp.42-46
    • /
    • 2018
  • The purpose of this study was to perform a survey of the radiation shielding design goals (P) and workload (W) based on the radiation safety reports concerned with structural shielding design for the IMRT treatment technique in Tomotherapy vaults. The values of the P and W factors as well as of a verified concrete thickness of the ceiling, bottom, sidewalls (sidewall-1 and sidewall-2), and door have been obtained from radiation safety reports for a total of 16 out of 20 vaults. The recommended and most widely used report for P values was the NCRP No. 151 report, which stated that the P factor in controlled and uncontrolled areas was 0.1 and 0.02 mSv/week, respectively. The range of the W factor was 600~14,720 Gy/week. The absorbed dose delivered per patient was 2~3 Gy. The maximum number of patients treated per day was 10~70. The quality assurance (QA) dose was 100~1,000 Gy/week. Fifteen values of the IMRT factor (F) were mostly used but a maximum of 20 values was also used. The concrete thickness for primary structures including the ceiling, bottom, sidewalls, and door was sufficient for radiation shielding. The P and W factors affect the calculation of the structural shielding design, and several parameters, such as the absorbed dose, patients, QA dose, days and F factor can be varied according to the type of shielding structure. To ensure the safety of the radiation shielding, it is necessary to use the NCRP No. 151 report for the standard recommendation values.